Document 8R9rqXrZELYQVReqrk2zpNq4K
Valves
The Fulton Company
NEW YORK
Knoxville, Tennessee
CHICAGO
Hudson Terminal Bldg. 50 Church Street
PHILADELPHIA Drexel Bldg.
4th and Chestnut Streets
BRANCHES:
DETROIT Book Bldg. Washington Boulevard
Representatives in All Principal Cities
Wrigley Bldg. Michigan Boulevard
BOSTON Pope Bldg. 221 Columbus Avenue
Patentees and manufacturers of Sylphon products. Sylphon Temperature and
Pressure Regulators, Thermostats for regulating temperatures of homes by
warm air furnaces, steam or hot water boilers; Temperature Regulating Radi ator Covers; Automatic Air and Vent Valves; Packless and Leakless Valves and other Heating Specialties.
Advantages
. All Sylphon devices em body the seamless, one-piece bellows of drawn metal shown at right. There is not a bit of solder throughout its length --no chance for leaks or breaks. It is a feature found exclusively in Sylphon Prod ucts. Sylphon diaphragms or bellows are made in sizes
ranging from 1)4 to 12 in.
O. 5.
No. 304 Standard Pressure Packless Valve
A special alloy Sylphon bellows surrounds
the stem and turning parts,
forming an ever-tignt bar
rier to leakage of steam
around the stem, nopacking,
hence no need of repacking.
This valve is largely used
for hazardous liquids and is
approved by the Under
writers ' Laboratory (No.
M. H. 988.) '
...
Cut Open Vtew
No. 536 Sylphon Radiator Air Valve
An improved radi
ator air valve with
large thermostat and
float which renders it
extremely powerful
and positive in action.
It is pleasing in design,
rigid in construction
and durable.
The active principle
is the Sylphon
bellows which
for many years
has been used by this com pany in all of
Cut-Open View
Shows Sylphon bellows. It will not buckle or
its heating boiler special ties.
distort and will never lose its efficiency. Has
ample movements, thus insuring tight closing
of the valve. It is so
Ask for Bulletin RAV 3
durable that, practi cally speaking, it will never wear out.
No. 527 Quick Vent Valve
I|pr venting mains, long
runs of pipe, indirect stacks,
drop risers, and all low pres
sure steam jobs where a large
amount of air must be expelled quickly. Vents entire piping sys tem and thereby heating radiators quicker under less pressure. No adjustment. Does not close against water. Venting port -fa in. diameter. Valve connec tion % in. pipe thread.
Ask for Bulletin RAV-3
No. 22 Steam Damper Regulator
Used to control the. dampers on steam heating boilers. A simple, accurate regu lator which will control the draught so as to maintain a constantsteam
pressure up to 51b. Thisreg-- ulator is sensitive, positive in action and will last a life time, due to the Sylphon one-piece, seamless, solderless, flexible metal bellows which it contains.
Ask for Bulletin RD-3
No. 45-A Hot Water Damper Regulator Used to control the
dampers on hot . water heating boilers. Simple, accurate regulators which will control the draft so as to maintain a constant temperature of the water at any point between 120' deg. and 220 deg. fahr. They prevent the tem perature of the water from rising higher than necessary, insuring faucet water of even temperature every hour of the day. They prevent the generating of steam in the system, thus eliminating the disagree able sputtering and blowing off when the faucet is Open. Ask for Bulletin RD-3
436
The Fulton Company
Vahes
No. 930 and No. 931 Temperature Regulators
For nearly all requirements where liquids are heated by steam, and especially industrial uses. Regulators are regularly
furnished with a tempera ture range of 140 deg. to 180 deg. fahr. Special regulators can be fur nished with adjustment for 20 deg. above or below the operating point for temperatures not lower than 20 deg. nor higher than 320 deg. fahr.
No. 930 Regulator is the same as No. 931, ex cept that it has lever and weight method of adjust ment instead of spring type shown. The extreme sensitiveness, positive ac tion and simplicity of these regulators make them specially suitable for control of hot water service tanks, and hundreds of other uses. No. 931 Regulators are fur nished regularly in sizes from )4`to 2)4 in. inclusive, and the No. 930 Regulator in sizes from )4 to 8 in. inclusive. Upon application, a chart will be fur nished showing size of regulator for any given condition.
Ask for Chart and Bulletin TR-3
No. 980 and No. 981 Temperature Regulators
For automatic control of air tempera tures. Same as 930 and 931 except bulb, of our own patented design, which is "star shaped,'1 giving greatest area of exposed surface to cubical content and mass of any design known. Ask for Bulletin TR-3
No. 932 Temperature Regulator
Detachable Tube Type: This is the latest development in self-contained reg ulators. This regulator is composed of
power transmitting unit may readily be
replaced by looseningtwo lock nuts, and the
repair part slipped into place. Movement
is transmitted by liquid pressure acting
between two small Sylphon Bellows and is
frictionless. Liquid is non-freezing.
This regulator is specially applicable
when steam line is awkwardly located or
at considerable distance from point of
control.
Ask for Bulletin TR-3
Sylphon Regitherm
The most powerful room thermostat on
the market. Requires no electricity, com
pressed air or clockwork to operate. Re
sponds to slight changes in
temperature of air and is
used to control valves,
dampers and shutters.
Works smoothly, never'
by jerks and is noiseless
in operation. Requires no
attention. Standard range 60 deg. to 80
deg. fahr. It is largely used in offices and
industrial plant work rooms. Small and
neat in appearance, being 6 wide by 7)4 in.
long.
Ask for Bulletin RR-3
The Ja-Nar Radiator Cover
Made of fine furniture steel, lined with heat insulating material. Completely covers hot water and steam radiators. Can be installed in old homes as easily as in new. Furnished in light or dark oak, ma hogany, walnut and various tinted enamels, or to match any interior wood-work.
Furnished in three types: 1st, Auto matic Temperature Control; 2nd, Man ually Operated Temperature Control; 3rd, Uncontrolled Type.
The controlled type Ja-Nar Radiator cover is equipped with a thermostatic de vice which opens or closes the shutters to regulate the heat sent out into the room. This is absolutely automatic in operation and can be set to operate at any comfort able temperature desired.
bulb' tubing. Each unit may be sepa
rately installed, removed or replaced as
the case may be. If the flexible tubing
should become damaged or broken, the
Ask for Pamphlet on the Ja-Nar
"Specification Data"--Send for our Specifications of Value" which gives com-
plete engineering data in regard to the ab ve products.