Document 8R9rqXrZELYQVReqrk2zpNq4K

Valves The Fulton Company NEW YORK Knoxville, Tennessee CHICAGO Hudson Terminal Bldg. 50 Church Street PHILADELPHIA Drexel Bldg. 4th and Chestnut Streets BRANCHES: DETROIT Book Bldg. Washington Boulevard Representatives in All Principal Cities Wrigley Bldg. Michigan Boulevard BOSTON Pope Bldg. 221 Columbus Avenue Patentees and manufacturers of Sylphon products. Sylphon Temperature and Pressure Regulators, Thermostats for regulating temperatures of homes by warm air furnaces, steam or hot water boilers; Temperature Regulating Radi ator Covers; Automatic Air and Vent Valves; Packless and Leakless Valves and other Heating Specialties. Advantages . All Sylphon devices em body the seamless, one-piece bellows of drawn metal shown at right. There is not a bit of solder throughout its length --no chance for leaks or breaks. It is a feature found exclusively in Sylphon Prod ucts. Sylphon diaphragms or bellows are made in sizes ranging from 1)4 to 12 in. O. 5. No. 304 Standard Pressure Packless Valve A special alloy Sylphon bellows surrounds the stem and turning parts, forming an ever-tignt bar rier to leakage of steam around the stem, nopacking, hence no need of repacking. This valve is largely used for hazardous liquids and is approved by the Under writers ' Laboratory (No. M. H. 988.) ' ... Cut Open Vtew No. 536 Sylphon Radiator Air Valve An improved radi ator air valve with large thermostat and float which renders it extremely powerful and positive in action. It is pleasing in design, rigid in construction and durable. The active principle is the Sylphon bellows which for many years has been used by this com pany in all of Cut-Open View Shows Sylphon bellows. It will not buckle or its heating boiler special ties. distort and will never lose its efficiency. Has ample movements, thus insuring tight closing of the valve. It is so Ask for Bulletin RAV 3 durable that, practi cally speaking, it will never wear out. No. 527 Quick Vent Valve I|pr venting mains, long runs of pipe, indirect stacks, drop risers, and all low pres sure steam jobs where a large amount of air must be expelled quickly. Vents entire piping sys tem and thereby heating radiators quicker under less pressure. No adjustment. Does not close against water. Venting port -fa in. diameter. Valve connec tion % in. pipe thread. Ask for Bulletin RAV-3 No. 22 Steam Damper Regulator Used to control the. dampers on steam heating boilers. A simple, accurate regu lator which will control the draught so as to maintain a constantsteam pressure up to 51b. Thisreg-- ulator is sensitive, positive in action and will last a life time, due to the Sylphon one-piece, seamless, solderless, flexible metal bellows which it contains. Ask for Bulletin RD-3 No. 45-A Hot Water Damper Regulator Used to control the dampers on hot . water heating boilers. Simple, accurate regulators which will control the draft so as to maintain a constant temperature of the water at any point between 120' deg. and 220 deg. fahr. They prevent the tem perature of the water from rising higher than necessary, insuring faucet water of even temperature every hour of the day. They prevent the generating of steam in the system, thus eliminating the disagree able sputtering and blowing off when the faucet is Open. Ask for Bulletin RD-3 436 The Fulton Company Vahes No. 930 and No. 931 Temperature Regulators For nearly all requirements where liquids are heated by steam, and especially industrial uses. Regulators are regularly furnished with a tempera ture range of 140 deg. to 180 deg. fahr. Special regulators can be fur nished with adjustment for 20 deg. above or below the operating point for temperatures not lower than 20 deg. nor higher than 320 deg. fahr. No. 930 Regulator is the same as No. 931, ex cept that it has lever and weight method of adjust ment instead of spring type shown. The extreme sensitiveness, positive ac tion and simplicity of these regulators make them specially suitable for control of hot water service tanks, and hundreds of other uses. No. 931 Regulators are fur nished regularly in sizes from )4`to 2)4 in. inclusive, and the No. 930 Regulator in sizes from )4 to 8 in. inclusive. Upon application, a chart will be fur nished showing size of regulator for any given condition. Ask for Chart and Bulletin TR-3 No. 980 and No. 981 Temperature Regulators For automatic control of air tempera tures. Same as 930 and 931 except bulb, of our own patented design, which is "star shaped,'1 giving greatest area of exposed surface to cubical content and mass of any design known. Ask for Bulletin TR-3 No. 932 Temperature Regulator Detachable Tube Type: This is the latest development in self-contained reg ulators. This regulator is composed of power transmitting unit may readily be replaced by looseningtwo lock nuts, and the repair part slipped into place. Movement is transmitted by liquid pressure acting between two small Sylphon Bellows and is frictionless. Liquid is non-freezing. This regulator is specially applicable when steam line is awkwardly located or at considerable distance from point of control. Ask for Bulletin TR-3 Sylphon Regitherm The most powerful room thermostat on the market. Requires no electricity, com pressed air or clockwork to operate. Re sponds to slight changes in temperature of air and is used to control valves, dampers and shutters. Works smoothly, never' by jerks and is noiseless in operation. Requires no attention. Standard range 60 deg. to 80 deg. fahr. It is largely used in offices and industrial plant work rooms. Small and neat in appearance, being 6 wide by 7)4 in. long. Ask for Bulletin RR-3 The Ja-Nar Radiator Cover Made of fine furniture steel, lined with heat insulating material. Completely covers hot water and steam radiators. Can be installed in old homes as easily as in new. Furnished in light or dark oak, ma hogany, walnut and various tinted enamels, or to match any interior wood-work. Furnished in three types: 1st, Auto matic Temperature Control; 2nd, Man ually Operated Temperature Control; 3rd, Uncontrolled Type. The controlled type Ja-Nar Radiator cover is equipped with a thermostatic de vice which opens or closes the shutters to regulate the heat sent out into the room. This is absolutely automatic in operation and can be set to operate at any comfort able temperature desired. bulb' tubing. Each unit may be sepa rately installed, removed or replaced as the case may be. If the flexible tubing should become damaged or broken, the Ask for Pamphlet on the Ja-Nar "Specification Data"--Send for our Specifications of Value" which gives com- plete engineering data in regard to the ab ve products.