Document 8Oqmdy7v5oR6vr3nxX518nryk

Copy No. 6 PROCESS FOR', THE PRODUCTION OF AROCLORS,; PYRANOLS, ETC. . AT THE ANNISTON AND AjP THE WM. 0. KRUMMRICH PLANT _ April 1955 -----i*-------------------- "E. Mather Distribution List; 1. Mr. J. S. Brough, London 2-. Dr. N. B. Dyson, Newport j5. Mr. 0. V. Taylor, Newport 4. Mr. 0. V. Taylor, Newport 5. Mr. W. E. Hamer, Ruspon ^6. Mr. J. F. Stickley,:--------- Krummrich Plant 7. Mr. J. F. Stickley,--------- St. Louis Library 8. M. C. L. file at Stj Louis 9. Mr. D. B. Hosmer, Aijniston 10. Spare I VI. PROCESS IN DETAIL, contd. VI - 24 Process In Detail Packing The finished Aroclcrs are rv^n off Into drums., a piece of diaper cloth being tied on the pipe outlet for the lighter Aroclors, and a piece of fine gauze for the heavier Aroclors, which have to be handled hot. This, of course, is to arres.t stray bits of pipe scale etc., but the precaution is now omitted at the Krummrich plant when materials are being filled directly from the delivery of the filter. Newport arrangements for filling and weighing drums are discussed in London Engineering Pinal Report, September 1951* page 1D8 and 1^3-10, also, in the start-up reports, July 24, and September 27, 1951. The drums must be clean and dry, especial care being needed with electrical grades. Newport complaint UF/61, November 1951, of turbidity in 1248 was traced to the presence of water in the drums. Apparently, in presence of water, the Aroclor reacted on the galvanizing of the drum. Newport plant report, December 1951, mentions the installation of equipment for drying, the drums. Care is taken not to do any packing if there is HC1 fume in the air. The gaskets for the bungs of the drums have to be correctly chosen. A sample of the gaskets supplied by the Melrath Supply & Gasket Co. to the Krummrich plant was sjent to MCL, April 1947. See also the discussion of gaskets on page 2, Section XII, below. Mr. Pemberton, December 1950 collected samples of the labels used at ;the Krummrich plant; one a patent list label, and the other a warning label on toxicity. The effect of exposure of Aroclors to metal contact is discussed in Section VII, comments, page 17 below. Generally speaking, the distilled Aroclors are packed in galvanized drums, the undistilled ones in black steel drums. (Flaked or milled solids were packed in barrels or Leverpac containers, bulk solid or resinous Aroclors go out in friction type lid drums, (galvanized for the distilled grades). Storage and blending of the distilled Aroclors is done in steel vessels sprayed with tin or zinc, or aluminum lined. DSW 000799 VI. PROCESS IN DETAIL, contd. VI - 55 Process in Detail Packing, corn'd. Since the Aroclors are such effective solvents , they damage, and are damaged by, ordinary paints, lacquers, insulating varnishes, etc. This feature is important in connection with hydraulic fluids containing Aroclors. See, for example, MCL Research Progress reports 1151, DP 54/26/7 and DP 54/277/6 and 1152 DP 4/ifc/y and 8 July 1954, etc., also the Section III, Physical & Chemical data, above. Drums for electrical grades of Aroclors are not painted. . Newport Plant Technical Committee meeting, April 14, 1955, page 2, reported some promising tests with lacquered drums for electrical^ _ grades._ It was decided not to use lacquered drums for resinous Aroclors on a returnable basis, because the lacquer suffered at the high temperatures likely to be used in melting the material from the drums. _ Aroclors also are dispatched in rail car3. At the Krummrlch plant the manhole of the car is protected by a tarpaulin tent during filling. Newport plant report for July 1954 mentions the Installation of tank-filllng^facilitles. The Krummrich plant operating instructions, August 10, 1954 mention that rail cars for Pyranols and Aroclors are insulated and have either a steam coil or a steam Jacket. They are lined with Aluminium or else sprayed with tin and zinc. Only dry air is used for unloading. MCC have a "Christmas Tree" fitting, a one piece fitting carrying air valve, dip pipe, release valve and pressure gauge, for use on. rail tanks. It is important to drain the coil or Jacket of the rail tank In cold weather. Galvanized or lacquered drums are used for Pyranols. ' DSW 000800 XI - 1 Hazards XI. HAZARDS. Toxicity There are many literature references*to harmful effects of the type of "chlor acne" resulting from exposure to chlorinated diphenyls, especially in cases where people working with small electrical com ponents have been exposed to the fumes of hot, highly chlorinated, Aroclors. Chlor acne is sometimes accompanied by gastric troubles, and there are literature references to liver troubles. There was some trouble of this kind among the production workers at =. Anniston in the early days of he development of the Aroclors. At that time highly chlorinated A;>oclors were being made from diphenyl which had come from low grade benzene. Since good benzene has been used, the same Aroclors have bo en made without trouble. In March 1955 it was reported that the Annis^on diphenyl and Aroclor plants had run 12 years without lost time-accident. - Prom the start of Aroclor manu acture at the Krummrich plant the operators have been supplied a clean change of clothes every day, and time has -been allowed at t !ie end of the shift for bathing. Operators are advised to wash ! Hands and face before eating. The Anniston operators do not have the same issue of clean clothes. Percy May, "Chemistry of Syjftthetic Drugs" , 5rd edition, page 19* The "Chemist Analyst", Sep tember 19^7/ Volume 56, No.2 page 55, and a report by Dr. M. C. L2 ster, Anniston plantTT 1957* give data on the toxicity of diphenyl MCC Bulletin P-ll5/4er$i edl|fc ons &?'to 1.0 mg. per cbm in air as the highest safe concentration of higher Aroclors, and 10 ng. lor more highly chlorinated Aro clors H. B. Edkins "Chemistry of Industrial Toxicology", page 1^9 gives 0.5 to 1,0 mg. as the allowable limit in working rooms. The MCC Bulletin "Physical Properties of Aroclors" mentions systemic effects arising from the oral injection of Aroclors. See the letters, E. Mather to P.J.C.Haywood, December 17, 1951, and Mather to Newman, January 6 , 1952, reviewing the literature on the toxicity of Aroclors. DSW 001105 See also correspondence relating to the article in Chem. & Eng. News -JMay 17/ 195^/ pages 2058 and the warnine labels mentioned on page VI-5^ above. XI. HAZARDS, contd. XI - 2 Hazards St. Louis, Main Office Mr. P. J. C. Haywood Newport (Airmail) cc: Mr. W. E. Hamer, Ruabon Mr. W. H. Ritchie, Ruabon Dr. H. R. Newman, Ruabon Mr. S. M. Kullfay, Krummrich Dr. D. S. Weddell, St. Louis Mr. F. T. Marshall, St. Louis Decerrber II, 1951 AROCLORS:{TOXICITY Since writing to you on December 3rd I have come across a letter of mine to Mr. W.f M. Cooper, London, June 24, 1948, (copies to W.D.S., W.H.G., and others), calling attention to an article in the J. T. Baker Company's "Chemist Analyst", Volume E6, No. 2, page 33, September 1947. ! I attach a copy of this arjticle, and I think you will agree that the warning relates only to really bad exposure. not such as should occur I 1 ordinary analytical work. On October 27, 19^7 Mr. Ba rbre of the Krummrich plant sent a copy of the Journal to Dr. Jenkins at Anniston for comment-i-- Dr. Jenkins did lot make~any comments . at the time but the following extract from Mr, Barbre's letter is inter- esting: "During the 11 years o production here only one man evidenced de atitis. He had also shown similar symptom] in several other departments. When ma, ng Aroclor #1270 which Is flaked, a noticeab e amount of fine fume solidifies in the airw If men are exposed to it during hot humid wfeather, the skin is irritated, but we hav not had any difficulty in curing cases of dermatitis from it".- OSW 001106 E. Mather XI - HAZARDS, contd. XI - 5 Hazards The Chemist Analys ,, Vol. 26, No. 2, page 25, J. T. Baker Chemlc ill Co., Phillipsburg, N. J. S ptember 19^7 ON THE TOXICITY OP THE "AROCHLORS" (sic) Robert M, Brown, Chief Industrial Hygiene Section, Division of Health Dept, of Public We fare. City of St.Louis, Mo. A recently published article (Miglio, M. Martin, ChemiBt Analyst, y^_ 9.4.:(19^6) ), has recommended the substitution of one of the "Arochlors" as the melting-point bath liquid in preference to the customary sulphuric acid. As stated in that article "Arochlors" are a group of- chlorinated diphpnyls produced by the Monsanto Chemical Company. There is need therefore to give warning. For the toxicity of these compounds has been repeat sdly demonstrated, both from the~ standpoints of their absorption from the Inspired air, as well as from their effects in produt -ing a serious and disfiguring dermatitis when allowed to remaL n in contact with the skin, Since these effects have been r jpeatedly observed, industrial hygienists have taken care to s se that the proper controls have been established wherever these products are used. For example, the maximum allowable concentrafb ion of chlorinated diphenyl for an 8-hour working day is 1 milljlLgrain per cubic meter of air. It is probable that nothing like an uncontrolled industrial expo sure will occur in the laboratory. However, whether an individual is subjected to a possible acut^ exposure to chlorinated diphenyl, and its serious consequences, will depend upon the size of the melting-point bath, the caution with which it is used, and the temperature to which it may be peated. Likewise, with careless handling of the material and the resulting contamination of the skin, clothing, laboratory towels, work table surfaces, etc. the -way is left open for the producing of dermatitis. Scrupulous cleanliness must be insisted uppn wherever this material is handled. The foregoing remarks have been, prompted by the belief that in re commending the use of a materia|L with which is associated a potential hazard from the health standpoint, it is very important that the possible consequences be presented together with recommendations for correct handling. DSW 001107 XI. HAZARDS, contd, XI - 4 Hazards Mr. A. C. W. Pennington of Newport, reporting on his American tour, December 29 > 1950# page p, writes: \ . "HEALTH AND SAFETY": i "At Anniston, no special protective clothing is provided for the Diphenyl and Aroclors operators. A daily change of clothing waB provided in the past but this practice ceased before the war. . Gauntlet leather gloves and fa|ce shields are, of course, available as required on the plant. i _ .. " Tins of cold cream olritment, theatrical quality, are to hand in the building, but the application of the cream is left to the operators decision of the job an question. The men are expected to take a bath, in their own time, at the epd of the shift. A good quality soap, and alcohol for trubbing down purposes, are provided. The operators are sufficiently trained in the need for personal cleanliness that a record of fcjiath taking is not warranted. "Emergency showers are provided on each floor of the Diphenyl building and safety notices are widely used. "At St. Louis, Plant B, Jthe Aroclors^building is rated a toxic department. Each operator is provided with a complete set of clothing comprising hat, coat, trousers, combination under clothes, socks and rubber shoes. A clean change of clothing, except shoes. Is placed in the operator's locker in time for the following shift. Men working extra shifts are given a clean set of clothing. Canvas gloves arid goggles are provided and 'Ply' hand barrier cream is available for use when necessary. ! "Twenty minutes' paid time Is allotted for bathing at the end of the shift but, again, no record 1b kept that baths are actually taken. Theoretlcallyl, food is not allowed to be eaten within the Aroclors building. Instructions are issued that hands and face should be washed well before eating. "Employees in toxic depa.trtments are given an annual medical examination and a lung X-ray e Yery three years." OSW 001108 XI - 5 Hazards XI. HAZARDS, contd. Toxicity, contd. . j t | A good deal of work has been dcjne on determination of^the vapour pressure of the Aroclors, and on the determination of/concentration of Aroclors in air. See pages 9-, Section III, above, for a summary of this work. In 1950 (letter April 20, N. F Rapps to E. Mather) the Admiralty expressed interest in the dete jjhnination of micro-quantities of Aroclors. MCC have a method fo;r the determination of traces in air by means of the "Halidometa Mr. Ellenburg, March 15, 1951*, mentions work done by H. B. Richards Jr., of MCC, June 17, 1953, on the determination of the concentration of Aroclors in air., Mr. Ellenljiurg also states: 11------------ work on the safe limits of Aroclor vapour concentration in air 1b being c.nrried on by the Medical Department at the Kettering Laborato:opies in Cincinnati. This work on animals 'is well under-way and will help us to know a little better just what is the s.ife limit of Aroclor Vapours that one might work in." A question has been asked about the possible harm to plants if Aroclor containing paints are used in greenhouses. The reply is that most paints are somewhat harmful, and there Is no evidence that Aroclors make them worse. Aroclors have been used as rabbit repellants, with out doing any harm to vegetation. Care is needed in laboratories etc. where Aroclors are used in heating baths; there should be very positive ventilation. The vapours of hot Aroclors arh distinctly irritating to eyes and nose above a concentration of about J> mg per cbm in air. Newport plant report for December 1951 records burns by hot Aroclor -- a case of a splash into a man's aye -- without serious damage. Packages of Aroclors leaving the Krummrich plant bear a label calling attention to possible toxic effects. DSW 0011Q9 Xi I........H. .AZi.Ai 1 RDS, ' .. contd. Fire Hazards ' i j j i: i XI - 6 Hazards Diphenyl, of course, will burn, and reasonable care is needed in handling it. Precautions with tjioluene are mentioned also on pages VI-29, and under '`Special Risks below. . The Aroclors are handled as if non-inflammable. Drums of material are melted in the middle of the operating building, by open gas flames, and open gas flames are freely used to heat pipe lines. An instruction, dated April 28, 19^8, calls for a daily inspection of safety showers, fire extingu" shers and gas masks, a check list being provided. Flanged joints on Aroclor heating system can be a source of fume. See the notes on gaskets, page a. Section XII, below. Phosgene may be generated in electrical flashes and fires in trans formers containing Aroclors, bu^ this is not thought to be a major risk. j Safety Equipment Each ^operator in the Krummrich Aroclor plant is supplied with goggles, rubber covered gloves, canvas gloves, rubber shoes and fume respirator See also page XI-1. A spare su: *t of clothes is kept in a case in the department. The department has the usual first aid cabinet, gas masks (chlorine), fire extinguisher, ^toluene, diphenyl), stretcher, safety showers, drinking fountain, eye bath. Special Risks i The usual care is necessary in dealing with chlorine, in lighting the gas furnaces, and in handling hot materials, steam lines etc. Diphenyl might start to burn in chlorine gas if conditions in the chlorinator were badly out of l}ne. A Davis "Vapotester", model M-li Type A, (Division of Davis Emergency Equipment Co., Inc., Newark, N.,`.) is held in the department for use in testing the air of the working building after toluene has been used, and for testing vessels before men are permitted to enter, and before "flame certificates" are given. The instrument contains a DSW 001110 XI - 7 Hazards XI. HAZARDS, contd. Special Risks, contd. j i | catalytic cell electrically hea;ed to a fixed temperature, and the air to be tested is aspirated through it by means of a "squeeze ball". If combustible vapours are present, the temperature of the cell rises, and the indicating thermocouple registers on a cali brated scale. ; The instrument has a zero adjustment, and It is checked twice a month by the Instrument department. Flame certificates must give the number of the Vapotester used, also the data of its last cali bration by the instrument department. The Instrument has been use ful in detecting gas escapes, aid in tracing spills of gasoline, etc.,- from a neighbouring oil refinery into a public sewer which runs under Monsanto territory. ; i Mr. Benignus, of St. Louis, September 1953* dlsoussed the dangers of using Aroclors in,indoor paints. He discounted the possible dangers from phosgene formed by~~flash dischargee in transformers charged with Aroclbrs. See the references to safe handling of glycidyl phenyl ether on pages IX-161 etc. f I osw 001111