Document 8OVQj4moRn0Bn5GzNrzg8L6wa

468 CHAPTER 33 1959 Guide Table i____typical ultimate Analyses for Coals 6fu per Lb CucsMueiti, tenant Moist, Mineralmatter- free* Moot, Received Oxygen Hydrogen Carbon Nitrogen Sutfar Anthracite...................................... 14,600 12,910 5.0 2.9 80.0 0.9 0.7 Semi-Anthracite............................ 16,200 13,770 5.0 3.9 80.4 1.1 1.1 Low-Volatile Bituminous............ 15,350 14,340 5.0 4.7 81.7 1.4 1.2 Medium-Volatile Bituminous-- 15,200 13,840 5.0 5.0 79.0 1.4 1.5 High-Volatile Bituminous A . ... 14,500 13,090 9.2 5.3 73.2 1.5 2.0 High-Volatile Bituminous B.... 13,500 12,130: 13.8 5.5 68.0 1.4 2.1 High-Volatile Bituminous C....... 12,000 10,750 21.0 5.8 60.6 1.1 2.1 Sub Bituminous B........................ 10,250 9,150 29.5 6.2 52.5 1.0 1.0 Sub Bituminous C........................ 9,000 8,940 35.8 6.5 46.7 0.8 0.6 lignite............................................. 7,500 6,900 44.0 6.9 40.1 0.7 1.0 {Btu u roeeirod) X100 + (100 - 1.1 Axh) Alfa o,+ H, + C 10.6 8.5 6.0 8.1 8.8 9.2 9.4 9.S 9.6 7.3 87.9 89.3 91.4 89.0 87.7 87.3 87.4 88.2 89.0 91.0 legend: F.C Fixed Carbon. Qan Table 2 .. .. Classification of Coals by Rank* VJA. - Volatile Matter. Btu = British thermal unite. Group barfs of fusmd Carbon or Bto MfaercrfMatter-Free Baas Regulate Ffayxkaf Properties I. Anthracite............... 1 III. Sub-bituminous-- 1. Meta-anthracite....... Dry F.C., 98 percent or more (Dry V.M., 2 percent or less) Dry F.C., 92 percent or more and less than 98 percent (Dry V.M:, 8 percent Non-agglomerating or less and more than 2 percent) 3. Semi-anthracite....... Dry F.C., 86 percent or more and less than 92 percent (Dry V.M., 14 percent or less and more than 8 percent) I. Low volatile bitu- Dry F.C., 78 percent or more and less than 86 percent (Dry V.M., 22 per cent or less and more than 14 percent) 2. Medium volatile bi- Dry F.C., 69 percent or more and less than 78 percent (Dry V.M., 31 percent or less and more than 22 percent) Sther agglomerating6 or non- 3. High volatile A bi- Dry F.C., less than 69 percent (Dry weathering' V.M., more than 31 percent); and moist1 Btu, 14,000* or more 4. High volatile B bi- Moist* Btu, 13,000 or more and less than than 14,000* 5. High volatile C bi- Moist Btu, 11,000 or more and less than 13,000* 1. Sub-bituminous A Moist Btu, 11,000 or more and less than 13,000* 2. Sub-bituminous h Moist Btu, 9500 or more and less than Both weathering and non-agglom 11,000* erating6 3. Sub-bituminous C Moist Btu, 8300 or more and less than IV. Iagmtic.................... Moist Btu less than 8300 Unconsolidated Adapted tram ASTM Standard*. 1SS7, BuppUmml, p. US, American Society far Testing Meierimle. * tku does oat m*inA lew nnh which hare osoanal phyakal end chemical properties aad which come within the limits of fixed carbon or Btu of tK. hif*^.mw*h,*nm'hH*fT*h*mK mnJ nh-hitiiTninmM raafa. All td tV-m or-ala either contain Iaa than 43 percept dry, mineral-matter-free fixed carbon, or have more than 15,600 incest, mineral-matter-free Btu. h u agglotnerstxas. damjfy in low-volatile peep of the bituminous class. * Moist Btu r-f,Ti to *vl containing its natural bed moisture but not including visible water on the surface of the coat. 4 It b recognised that there may be oon^ahing varieties in each group of the bituminaze dasa. * fWh having N pfrut or more fixed carboo on the dry, mineral-matter-free basis shall be classified according to fixed carbon, regardlas of Btu. * There are three varietba of coal in the high-volatile C bituminous cal group, namely. Variety 1, agglomerating and non-weathering; Variety t, agglomerating and weathering; Variety I, non-aggbuwiating and non-weathering. Fuels and Combustion 469 labie 3 .... Standard Anthracite Specifications* T*ut Med Round Size of Cod Through to. Ovat k Orara'n Max % _Broken.- 4H. 3H to 3 Egg........ 3K to 3 2H Stove.... 2Ha m Nut....... 1% 'He 5- 7H 7H Pea........ lHe Ha 10 Buck- wheat... >u Rice. ... Ha He 10 Ha 10 Barley... Ha Ha 10 No. 4. . . Ha H* 20 No. 5... Ha 30 IMmia % Max Mb 15 7M 15 7H 15 7H 15- 7M 15 7H 15 7H 17 7H 20 10 30 10 No unit Maximum (npantei % ~ i o. iM 2 1H 2 23 34 45 11 11 11 11 12 13 13 15 15 16 * Approved andadopted, effective July 28,1M7, by the Anthracite Committee (Mosuaef tf Stetiduml lafermatie*, Anthracite Institute.) b When elate content is the sues from Broken to Nut inclusive b lees than shove standards, bone content may be ismeund by one and one-half times the desease in the date content under the allowable limits, but elate eootenl speci fied above shall mb be exceeded in any event. Ash dsterminations are on a dry basb and include bone and ash. A tolerance of 1 percent b allowed on the nmnn percentage of ondersise and the ntarimiija percentage of ashcontent. Themaximum percentage of uaderaise b applicable only to anthracite as it b produced at the preparation plant. Slate b as any material which has leas than 40 percent of fixed carbon. Bone b defined ea any materialwhich has 40 percent or more, but lean than 76 fngpuit of fiv--t eib<ii soot are possible, if improperly bred, especially at low rates of burning. V Sub-bituminous cools occur in the western states'!'- they are high in moisture when mined and tend to break up as they dry or when exposed to the weather; they are-liable to ignite spontaneously when piled or stored. They ignite easily and quickly, and have a medium length flame; are non-caking and free-burning; the lumps tend to break into- small pieces if poked; very little smoke and soot are formed. Lignite is of woody structure, very high in moisture as mined, and of low beating value; it is clean to handle. It has a greater tendency than the sub-bituminous' coals to disintegrate as it-dries, and it also is more liable to sponta neous ignition.- Freshly mined lignite, because of its high moisture, ignites slowly. It is non-caking. The char left after the moisture and volatile matter are driven off burns very easily, like charcoal. The lumps tend to break up in the fuel bed, and pieces of char falling into the ashpit continue to bum. Very little smoke or soot is formed. Gassrficarton of Cokes Coke is produced by the distillation of the volatile matter from coal. The type of coke depends on the coal or mixture of coals used, on the temperatures and time of distillation and, to some extent, on the type of retort or oven. Petroleum coke is produced as a residue from the destructive distiHat-inn of oil: COMBUSTION OF SOLID FUELS Firing Methods for Anthracite An anthracite fire should never be poked or disturbed, as this serves to bring ash to the surface of the fuel bed, where it may melt into clinker. Egg size is suitable for large fire-pots (grates 24 in. and over) if the fuel can be fired at least 16 in. deep. For best results this coal should be fired deeply. Stove is the proper size of anthracite for many boilers and furnaces. It burns well on grates at least 16 in. in diameter, on which it is fired about 12 in. deep. The fuel should be fired deeply and uniformly. Chestnut size coal is in demand for fire-pots up to 20 in. in diameter, and is usually fired to a depth of from 10 to IS in. Pea sue coal is often an economical fuel to burn. When fired carefully, pea coal can be burned on standard grates. Care should be taken to shake the grates only until the first bright coals begin to fall through the grates. The fuel bed, after a new fire has been built, should be increased in thickness by the addition of small charges until it is at least level with the sill of the fire-door. A satisfactory method of firing pea coal consists of drawing the red coals toward the front end, and piling fresh fuel toward the back of the firebox. Pea size coal requires a strong draft, and therefore the best results generally will be obtained by keeping the choke damper open, and regulating solely by means of the cold-air check and the air-inlet damper. Buckwheat size coal, for best results, requires more at'tention than pea size coal, and in addition the smaller size of the fuel makes it more difficult to bum on ordinary grates. Greater care must be taken in shaking the grates than with the pea coal to prevent fuel from falling through the grate. In house heating furnaces, the coal should be fired lightly and more frequently than pea coal. When banking a buckwheat coal fire, it is advisable after coaling to expose a small spot of hot fire by putting a straight poker down through the bed of fresh coal. This will serve to ignite the gas that will be distilled from the fresh coal and prevent delayed ignition which, in some cases, depending upon the thickness of the bed of fresh coal, is severe enough to blow open the doors and dampers of the furnace. Where frequent attention can be given and care is exercised in manipulation of the grates, this fuel can be burned satisfactorily without the aid of any special equipment, except small mesh grates. In general, it wifi be found more satisfactory with buck wheat coal to maintain a uniform heat output and, con sequently, to keep the system warm all the time, rather than to allow the system to cool off at times and then to attempt to burn the fuel at a high rate while wanning up. A uni form low fire will minimize the clinker formation and keep any clinker formed in an easily broken up condition so that it readily can be shaken through the grate. Forced draft and small mesh grates or, for greater convenience, domestic stokers are frequently used. Buckwheat anthracite No. 2, or rice size, is used princi pally in stokers of the domestic, commercial and industrial type. No. 3 buckwheat anthracite, or barley, has no ap plication in domestic beating. Firing Methods for Bituminous Coal A commonly recommended procedure for firing domestic heating units, called the side-bank method, requires the movement of live coals to one side or the back of the grate, and placing the fresh fuel charge on the opposite side. The results are a more uniform release of volatile gases, and the subjection of these gases to the high temperature of the red coals. If the fresh charge is covered with a layer of fine coal, still better results may be obtained because of slower release of volatile matter. Bituminous coal should never be fired over the entire