Document 8O7n01JkzkdOxgpgwY64bbV5y

Heaters, Water The Patterson-Kelley Co. 101 Park Avenue New York City Preheaters, Heat Exchangers, Headers for Chemicals, Gases, Oils. Coolers for Brine, Chemicals, Gases, Oil and Water. Hot Water Heaters for all purposes. Pool Heaters and Converters. The Patterson Com bined Hot Water Service and Storage Heater, Type B, is for any service where requirements for hot water are not con stant, or where a large volume must be stored for sudden heavy demands. REUCF VALVE THERMOMETER MOT WATER OUTLET General Specifications Constructed like a high grade boiler--of heavy steel plate. Steam inlet and outlet chamber is a heavy, grey iron casting. Tube head is a heavy, steel forging into which both ends of each tube are expanded. Tubes are of pure, cold drawn seamless copper and `lY shaped to provide against contraction and expansion strains. Heater is for any service and in any required size per tables below. Write us for engineering advice. STORAGE CAPACITIES No. Dimensions in Inches Capacity Approx. in Gals. - Wl in Lbs. No. Dimensions in Inches Capacity in Gals. Approx. Wt. in Lbs. 1S 2S 3S 4S 5S 6S 7S 8S 9S I0S 11 S 12 S 13 S 14 S 13 S 16 S 17 S 18S 19 S 20 S No. 24* 48 24* 60 24* 72 24* 84 30* 60 30* 72 30* 84 30* % 30* 120 36* 72 36* 84 36* 96 . 36* 108 36* 120 36* 144 42* 72 42* 84 42* % 42 x 108 42* 120 94 118 141 164 180 215 255 285 360 310 365 413 475 500 640 430 500 575 650 720 650 750 850 950 875 1000 1150 1300 1500 1250 1400 1550 1700 1850 2100 1500 1650 1800 1950 2200 21 S 22 S 23 S 24 S 25 S ` 26 S 27 S 28 S 29 S 30 S 31 S 32 S 33 S 34 S 35 5 36 S 37 S 38 S 39 S 40 S 42* 144 42* 168 42* 192 48* 96 48* 120 48* 144 48* 168 48* 192 54* 120 54* 144 54* 168 54'* 192 60* 120 60 x 144 60* 168 60 * 192. 72 * 174 84* 168 96* 168 96* 192 860 1000 1155 750 940 IIV5 1300 1500 1190 1425 1665 1900 1400 1700 2000 2240 3000 4000 5200 6000 2450 2600 3100 2600 2925 3350 3840 4200 3500 3900 4300 4700 4300 4950 5600 6200 7000 8700 10000 11000 HEATING CAPACITIES--40 F. to 180 F.--Steam at Atmospheric Pressure. Gallons per Hour Approx. Wt. in Lbs. | No. Gallons per Hour Approx. Wt. in Lbs. 1H 2H 3H 4H 5H 6H 7H 8H 9H 10 H 11 H 12 H 13 H 14 H 100 150 200 250 300 400 500 600 700 800 1000 1250 1500 1750 200 15 H 2000 700 215 16 H 2500 800 235 17 H 3000 900 255 18 H 3500 1050 285 19 H 4000 1200 315 20 H 4500 1350 350 21 H 5000 1500 370 22 H 6000 1750 400 23 H 7500 2000 425 24 H 10000 3200 450 25 H 12500 3800 500 26 H 15000 4500 550 27 H 20000 5100 600 28 H 25000 5600 NOTE--To specify Type B. Heaters, combine the numbers of the required storage and heating capa cities. For example. "One Patterson Type B. Heater with No. 22 S. and No. 17.H." has 1000 gallons storage with 3000 gallons hourly heating capacity. 264 Heaters, Water Ross Heater & Mfg. Co., Inc. Buffalo, N. Y. Represented in all Principal Cities Heaters, Condensers, Coolers, Water Strainers, Heat Exchangers, Evaporators, Vacuum Pumps and Expansion Joints for all Services. Ross Radiol Flow Instantaneous Heater Instantaneous Heaters cover a very wide fields in fact a large per cent of services can be taken care of with this type even though no attempt is made to carry a supply of the heated liquid in reserve or storage. A few of the services are: Hot water service supply for hotels, factories, hospitals, schools, apartment buildings, etc. Water for hot water heating systems for either forced or gravity circulation. Oil for pipe lines, storage stations, fuel oil burning apparatus, etc. Boiler feed water for high or low pressure. Water for swimming pools. Sugar juice in cane or beet sugar houses. Chemical com pounds of all kinds, etc. Straight tubes are used and they are accessible at both ends. Ross Storage Type Heater The Ross Storage Heater meets a condition where it is desirable to store up and have in reserve a supply of hot water. This heater is made in various combinations of storage tanks and heating elements so as to meet any condition of service. The heating element is located on the bottom and extends practically the full length of the tank. The entire heating element can be removed for cleaning or repairs. The tubes are straight and expanded into both tube sheets, one of which is of the floating type. 265