Document 8O7n01JkzkdOxgpgwY64bbV5y
Heaters, Water
The Patterson-Kelley Co.
101 Park Avenue
New York City
Preheaters, Heat Exchangers, Headers for Chemicals, Gases, Oils. Coolers for Brine, Chemicals, Gases, Oil and Water. Hot Water Heaters for all purposes. Pool Heaters and Converters.
The Patterson Com bined Hot Water Service and Storage Heater, Type B, is for any service where requirements for hot water are not con stant, or where a large volume must be stored for sudden heavy demands.
REUCF VALVE
THERMOMETER MOT WATER OUTLET
General Specifications
Constructed like a high grade boiler--of heavy steel plate. Steam inlet and outlet chamber is a heavy, grey iron casting. Tube head is a heavy, steel forging into which both ends of each tube are expanded. Tubes are of pure, cold drawn seamless copper and `lY shaped to provide against contraction and expansion strains. Heater is for any service and in any required size per tables below. Write us for engineering advice.
STORAGE CAPACITIES
No.
Dimensions in Inches
Capacity
Approx.
in Gals. - Wl in Lbs.
No.
Dimensions in Inches
Capacity in Gals.
Approx. Wt. in Lbs.
1S 2S 3S 4S 5S 6S 7S 8S 9S I0S 11 S 12 S 13 S 14 S 13 S 16 S 17 S 18S 19 S 20 S
No.
24* 48
24* 60 24* 72 24* 84
30* 60 30* 72
30* 84 30* % 30* 120 36* 72
36* 84 36* 96
. 36* 108 36* 120 36* 144
42* 72 42* 84
42* % 42 x 108 42* 120
94
118 141
164 180 215
255 285 360 310
365 413 475 500 640 430 500
575 650
720
650
750 850 950 875 1000 1150 1300
1500 1250
1400 1550 1700 1850
2100 1500 1650 1800 1950 2200
21 S 22 S 23 S 24 S 25 S ` 26 S
27 S 28 S
29 S 30 S
31 S 32 S 33 S 34 S 35 5 36 S 37 S
38 S 39 S
40 S
42* 144
42* 168 42* 192 48* 96 48* 120 48* 144
48* 168 48* 192
54* 120 54* 144
54* 168 54'* 192
60* 120 60 x 144
60* 168 60 * 192. 72 * 174 84* 168 96* 168
96* 192
860
1000 1155 750 940 IIV5 1300 1500
1190 1425
1665 1900 1400 1700
2000 2240 3000 4000 5200
6000
2450 2600 3100 2600 2925 3350
3840 4200
3500 3900
4300 4700 4300 4950 5600 6200 7000
8700 10000
11000
HEATING CAPACITIES--40 F. to 180 F.--Steam at Atmospheric Pressure.
Gallons per Hour
Approx. Wt. in Lbs.
|
No.
Gallons per Hour
Approx. Wt. in Lbs.
1H 2H 3H
4H 5H 6H 7H
8H 9H 10 H 11 H
12 H
13 H 14 H
100 150
200 250 300
400 500
600 700 800
1000 1250 1500 1750
200 15 H 2000 700
215 16 H 2500 800
235 17 H 3000 900
255
18 H
3500
1050
285
19 H
4000
1200
315
20 H
4500
1350
350 21 H 5000 1500
370 22 H 6000 1750
400 23 H 7500 2000
425
24 H
10000
3200
450
25 H
12500
3800
500
26 H
15000
4500
550
27 H
20000
5100
600
28 H
25000
5600
NOTE--To specify Type B. Heaters, combine the numbers of the required storage and heating capa cities. For example. "One Patterson Type B. Heater with No. 22 S. and No. 17.H." has 1000 gallons storage with 3000 gallons hourly heating capacity.
264
Heaters, Water
Ross Heater & Mfg. Co., Inc.
Buffalo, N. Y.
Represented in all Principal Cities
Heaters, Condensers, Coolers, Water Strainers, Heat Exchangers, Evaporators, Vacuum Pumps and Expansion Joints for all Services.
Ross Radiol Flow Instantaneous Heater
Instantaneous Heaters cover a very wide fields in fact a large per cent of services can be taken care of with this type even though no attempt is made to carry a supply of the heated liquid in reserve or storage. A few of the services are: Hot water service supply for hotels, factories, hospitals, schools, apartment buildings, etc. Water for hot water heating systems for either forced or gravity circulation. Oil for pipe lines, storage stations, fuel oil burning apparatus, etc. Boiler feed water for high or low pressure. Water for swimming pools. Sugar juice in cane or beet sugar houses. Chemical com pounds of all kinds, etc. Straight tubes are used and they are accessible at both ends.
Ross Storage Type Heater
The Ross Storage Heater meets a condition where it is desirable to store up and have in reserve a supply of hot water. This heater is made in various combinations of storage tanks and heating elements so as to meet any condition of service. The heating element is located on the bottom and extends practically the full length of the tank. The entire heating element can be removed for cleaning or repairs. The tubes are straight and expanded into both tube sheets, one of which is of the floating type.
265