DD. istribution: \ lant Copy ile Copy J. C. Landwehr TSD/Lab COMPANY CONFIDENTIAL MONSANTO COMPANY ANNISTON ALABAMA December 1971 Ag Division * ' Winterization for Methyl production during cold weather was completed except for the final items requiring plant shutdown. These will be completed during the late Januaryearly February turnaround. Design completed for conversion of P2S5 Therminol 66. system to Preliminary design completed for addition of three Dorrclones for removal of waste treatment plant solids. Decision to move was based on the excellent performance of the existing Dorr-clone in solids concentration. Vendors were contacted and quotes requested on equipment for recycle of Niran sniff chlorine vapor to tank cars as un loading pad. Detail estimates were made for PNP expansion by 2.0M lbs. Project will be prepared in early January. Polyphenyls The Santowax storage tank arrived. CED drawings received and being modified to permit installation of only tank and pump. Some materials (E/I) on hand and transferred from CED construction to. storeroom. Other items being ordered and expedited. The location of the tank was changed due to potential blocking of a fire lane (alternate route will be blocked more than originally thought). Complete project package will be transmitted by 15 Jan. '72. HB-40 Issued progress report No. 3, 105-1161 on 17 Dec. '71 on Hydrogen Purification Unit Revamp. Design capability upgrade from 65% to 70% recovery. TSD is investigating the cost of a 500 psi hydrogen compressor to allow shorter WCM autoclave cycles and higher recovery of available hydrogen. 0S\N 55A553 STLCOPCB4089970 2. Solid Aroclor Scheduled shutdown and abandonment of these products by mid-1972 has caused a wave of uncertainty concerning the future of the Polyphenyl business! Standby Propane System Ignition system for remote lighting of flare installed and operating. Through Dec. 31, 1971 the unit has operated for 207 hours during curtailment periods. Some minor work still remains before project completion. Fire Alarm System Alarm system was modified and successfully tested. The alarm is now "locked in" when the code is dialed, i.e. the phone is "free" to make other calls as soon as the alarm starts. HB-30 Crystals Study Twenty samples of HB-30 were prepared to evaluate the effect of hydrogenation level, quaterphenyl level, and blending on the formation of crystals in the freezethaw test. Results showed that all samples made within the present hydrogenation level specification limit passed the freeze-thaw test. However, samples made by blending material with a hydrogenation level lower than specified with material with a higher hydrogenation level did not pass the test. It is, therefore, critical that each batch be hydrogenated within spec limits. /dp DSW 551554 STLCOPCB4089971 PLANT LABORATORIES 3. ANALYTICAL AND QUALITY CONTROL - S. O. Kemp Complaint Report Quality Number ATL 24-P Material S-140 & S-981 Customer Reason Pandel Chemicals S-140 off color but material was accepted; S-981 - temperature 110F too high YTD Complaints/100 Shipments 0.27 Target - 0.20 1970 Manpower/sample 1971 YTD Manpower/sample 0.63 0.39 1970 $/manhour 1971 $/manhour 13.18 8.80 sw 551555 STLCOPCB4089972 1971 DISTRIBUTION OF TIME BY TECHNICAL SERVICE \ f c rti b A d) ft S*J id a uft >1 (0 c 3 < a O iH b O' ft 3 (U <w P > Uo Oz o d) Q EXISTING PRODUCT 70 TECHNOLOGY IMPROVEMENT NEW PRODUCT EVALUATIONS 60 MAJOR PROJECT SUPPORT 50 PROCESS CONTROL IMPROVEMENT 40 PROJECT DESIGN TECHNOLOGY AND TECHNICAL SUPPORT TECHNICAL MANPOWER PLANT IMPROVEMENT PROGRAM REAL ESTATE MANAGEMENT 10 0 A <D b ft id S P ft id <a r-1 bb O' ft . 3 (U < Pi +> > u O 0 (1) OzQ DSW 551556 STLCOPCB4089973 CONFIDENTIAL THIS POLLUTION CONTROL SECTION IS FOR IMMEDIATE INFORMATION PURPOSES ONLY. NOT TO BE FILED. Pollution Control Summary for December 1971 - E. G. Wright, M. D. Turner (J. T. Bell) Environmental Control Log Book Information Nothing during December. Air Pollution 1. Three air pollution complaints were received from plant neighbors during December. All were investigated and attributed to SO2. Weather conditions during the month hampered the dispersion of SOj. 2. Monsanto Research Corporation was contacted in December for a quote on using their math model for predicting SC>2 seasonal concentration isopleths. This data will be used to determine the optimum location for an SC>2 monitoring station. This station will be necessary for satisfying O.S.H.A. and Alabama Air Pollution Commission rules governing SO2 ambient.air concentrations. 3. Considerable efforts in December were expended in preparing a statement of Monsanto's position on the proposed rules and regulations by the Alabama Air Pollution Commission. This statement will be submitted at the Commission's public hearings in January if deemed appropriate. Waste Pollution 1. Drs. Gunning and Suttkus (Biological Consultants) collected the December set of fishes from Choccolocco Creek on Dec. 6, 7, 8, and 9. This is the first quarterly trip of the second year in the P.C.B. residue studies. 2. During December 132 samples were analyzed for trace P.C.B.'s. Fifty-three of these were water samples which included 18 final lots of HC1 for shipment. Seventy-nine samples were analyzed for the Nitro Plant in a continuing effort to define their P.C.B. problems. DSW 551557 STLCOPCB4089974 MID-MONTH REPORT PR&D LABORATORY ANNISTON PLANT PROJECT TITLE: Methyl PCT Analytical Methodology PERIOD ENDING: December 15, 1971 CHEMIST: Jerry L. Brown Objective: To determine differences between Anniston and St. Louis GLC methodology for PCT assay and isomer analysis. Results and Discussion: A sample of Methyl PCT produced from the improved PCT process described in Ag Research Progress Report 2104 was analyzed by Anniston and St. Louis. The results of these analyses, as previously reported, are as follows: Anniston Method 044 St. Louis Method % Me PCT 91.9 94.5 % "C" Isomer 2.47 2.04 % "G" Isomer 4.02 0.3 This sample was then reanalyzed during the above time St. Louis method . The results were as fol1ows: % Me PCT 91.62 % "C" Isomer 2.46 % "G" Isomer 2.28 The GLC was then converted to conditions, including columns, employed by the Anniston procedure. The sample was again analyzed in duplicate resulting in the following: % Me PCT 94.4 % "C" Isomer 1.41 , % "G" Isomer 0.71 A close examination of the St. Louis instrument revealed that the major difference from the Anniston instrument was injection port design. Sample injected into the former instrument had to ' . r " '' j DSW 551558 STLCOPCB4089975 Metl._ . PCT Analytical Methodology - J. L. Brown 2 travel a much longer path through a metal port than the latter, which utilized on-the-column injection. It was decided to try a third instrument which was equipped with glass columns and on-theco'lumn injection. Results from this test are: % Me PCT 91.66 % "C" Isomer 2.95 % "G" Isomer 2.65 It was decided that this procedure utilized the most thermallystable conditions possible and should, therefore, yield the best results. In addition to the above, a sample of Methyl PCT prepared by the recycle process was analyzed on this GLC resulting in the follow ing: % Me PCT 96.25 % "C" Isomer 0.83 % "G" Isomer 1.93 Cone!us i ons: _ 1. It was concluded that two phenomena can occur in the GLC that can cause the discrepancies that have been noted. These are (a) isomerization of PCT by S2C12 to result in an ab normally high content of "G" isomer and (b) thermal degradatio'n of "G" isomer to result in an abnormally low amount of "G" isomer. It would be possible for either phenomena to occur separately or at the same time at some GLC conditions. Therefore, to minimize these discrepancies, it was decided that a GLC procedure be adopted which utilized glass columns, on-the-column injection, and the lowest operating temperature possible. 2. GLC is at best a poor tool for analyzing these thermally unstable compounds. The most`satisfactory analytical tool known is phosphorus NMR which is a non-destructive method. /dp DSW 551559 STLCOPCB4089976 MID-MONTH REPORT PR&D LABORATORY ANNISTON PLANT PROJECT TITLE: Differential Thermal Analysis (DTA) Study of Improved Methyl PCT Process Described in AG Research Progress Report 2104 (1) PERIOD ENDING: December 15, 1971 CHEMISTS: G. L. Arnett and I. Ransaw Written by I. Ransaw AG Research Report 2104 (1) by A. E. Lippman describes a process in which the yield of distilled Methyl PCT is increased 7-9% by increasing the chlorination level from 105 to 112%. This process involves the following basic steps: 1. Chlorination - A batch of 1500 grams of thio acid is chlorinated using 690 grams of chlorine @ 50 - 55C over 6 hours, with N? added to the chlorine at a rate of 240 ml./min. after 520 grams of chlorine is in. 2. Sulfur Removal - Part of the sulfur (liquid) is allowed to settle from the chlorination mass over a period of 2-3 hours at 45 - 50C while the remainder of the sulfur is removed after holding the mass for an approxi mate 12 hour period at room temperature. 3. Distillation - The chlorinated mass (without sulfur) is distilled at 10 mm to a pot temperature of 80C. To provide thermal stability data for this process, two Methyl PCT batches were prepared according to this process for DTA analysis. For comparison a batch was chlorinated to 105% (typical for plant). DTA results for the chlorinated batches (before distillation) were within the normal DTA limits: . @ 80C -- 50 cal./kg./min. . @ 100C -- 150 cal./kg./min. DTA's for the still residues of the two (proposed process) batches and comparison batch were as follows: - Process Run #1 @ 80C -- 72.7 cal./kg./min. @ 100C .-- 403.3 cal./kg./min. DSW 551560 STLCOPCB4089977 DTA tudy of Improved Methyl PCT Process - I. Ransaw 2. Process Run 2 \ 0 80C -@ 95C -- 72.7 cal./kg./min. 403.3 fcal./kg./min. 0 100C -- Off chart Comparison Batch 0 80C -- Nil @ 100C -- 63.5 cal./kg./min. These results indicate that the still residues for the proposed process were abnormally high (unstable) in comparison to typical pi ant still residues. In an effort to stabilize or find the cause for instability in the still residues, changes were made in the process following the chlorination step or sulfur removal step. The procedure and results of the changes are described in the following tests: Run 3 After chlorination the chlorinated mass (no sulfur removed) was allowed to set at room temperature overnight and then distilled at 10 mm to a pot temperature of 80C. The still residue was allowed to cool to 45 - 50C. Then a residue sample (containing approxi mately 1:1 ratio by volume of organic to the sulfur mass') was transferred immediately to a DTA cell. The DTA results are as fol1ows: @ 80C -- 87.8 cal./kg./min. 0 100C -- 313.7 cal./kg./min. Run #4 After the sulfur removal, 205.3 grams (wt. equiv. to sulfur re moved) of No. 2 diesel fuel was added to the chlorinated mass before distillation. The distillation was carried out under normal conditions. The still' residue had the following DTA: @ 80C -- 61.2 cal./kg./min. @ 100C -- Exotherming too badly to complete DTA Neither of the process changes resulted in a more stable residue. /dp DSW 551561 STLCOPCB4089978