Document 8G4Yv57paNENDepddg2B7N7a

3?/VT. ' ' 1 i i l Ji WRG u J. v> U UTAH STATE IHVMSH'N tiU I'.l'.Al.TIl Report of Occupational Health Srudv I toward Johnson Mol or l-odj'.c c/o Western States Insulation Company 118 West Souch Temple ,s PLAINTIFF'S SURVEY DATE: 13, 14 & 16 October 1972 REPORT DATE: 17 October 1972 PARTICIPANTS: F.M. Newson, Industrial Hygienist Utah State Division of Health eport i'tvpa rod Hv: / s ' > . . Ncwn'i: ndustrial livj> icnist Report of Occupational Health Study Howard Johnson Motor Lodge c/o Western States Insulation Company 118 West South Temple I I PURPOSE: As a supplement to an earlier survey, quantitative adbestos measurements of airborne and settled particulates were made on 13, 14 and 16 October, 1972, at the Salt Lake City Howard Johnson Motor Lodge construction site. II GENERAL OBSERVATIONS: "Zonolite Monokote" fireproofing, which contains asbestos, is manufactured by Vermiculite Intermountain Salt Lake City. It is batch mixed at ground level on the construction site. The operator tending the mixer wears a respirator while opening and dumping the bags. He removes his respirator at all other times Respirators had not been worn by the tender prior to an inspection by the Industrial Commission during the first week of October 1972. After mixing, the wet slurry is pumped to the appropriate floor and is sprayed on the structural steel. Two men handle the spray nozzle and both are subjected to exposure of the splash from spraying. The clothing of both of the spray gun operators is covered with dried insulation dust. There is an accumulation of overspray on the floors, planking, and scaffolding and the material is tracked over the entire work area by foot traffic of the workmen. The spray gun operators are exposed to inhalation of asbestos fibers from the airborne spray, and from the heavy dust present on their clothing. Other workers on the job are exposed to the dust from foot traffic. Asbestos exposure from inhalation of spray is likely to be considerably lower for ocher workmen than for the sprayers. Samples of breathable asbestos fibers were collected from worker's breathing zones and general work areas and were submitted to the laboratories of National Institute for Occupational Safety and Health, Salt Lake City, for asbestos fiber count. Samples of other sprayed materials used on the building were submitted to the same laboratories for determination of percentage of asbestos. Details of sampling procedures are shown in Section III. 111 SAMPLING AND ANALYTIC PROCEDURES: Breathable fibers were collected on a 37 nn diameter type AA filter using a portable battery powered air sampler pump. Mine Safety Appliance Company, Model 92814 or 456253. Count of fibers was made by National Institute for Occupational Safety and Healtli Salt Lake City personnel using 430x magnification phase contrast illumination and a I'orton Reticle. Determination of Clio pciceufa>:e of asbestos concent of bulk samples of the listed materials was performed by National Institute for Occupational Safety anc Health Salt Lake Citv laboratories using standard laboratory procedures for suen ana lysis. ' V". '. . ..........^ -------------------------- V. - - V *.`T.r** s^pse* * * \T results ok ANALYSIS: Filter # Location 1 Breathing Zone-spray gun operator #1-15 min. sample 2 Breathing Zone-spray gun operator #1-30 min. sample 3 Breathing Zone-spray gun operator #2 - 15 min. sample 5 Breathing Zone-spray gun operator #2 - 30 min. sample 4 Wet Spray Area, 6 ft. off floor 10-20 ft. from spray nozzle-30 min. sample 6 Near workers who were operating hand grinders on floor 30-40 ft. away from spraying. Sprayers had not yet worked this portion of building-60 min. sample 7 Breathing Zone of mixer tender30 min. sample 9 Breathing Zone of surveyor (2nd floor) during clean-up - 30 min. sample. Asbestos Fiber Court 4.7 fibers/cc 2.9 fibers/cc 2.7 fibers/cc 3.0 fibers/cc 0.1 fibers/cc 0.2 fibers/cc 0.9 fibers/cc 0.7 fibers/cc ASBESTOS CONTENT: Bulk Sample # 17 19 Location and Description Percent of Asbestos Soundproofing material (3rd floor) none Ceiling spray material (2nd floor) none comments ano nkcommenoations; Ni' asbestos fibers wore found in cither the soundproofing materials or finish tn.itcii.11 k used on sprayed ceilings. !l tan therefore be assumed that th-. l i rep root iny, material alone is die only source of significant amounts of asbestliber on this job. In order to prevent asbestosis and otherwise comply with good industrial h'.';' i i! :i practices, die following work practices should bo immediately set ur.: (I) Vpra-.irs should be provided wi: a and roou i red lo wear suitable respirators <>i a r>'pe approved by National institute for Occuna i i oua 1 Safe tv a:ui dial::, or Cite IMS. liureau of Mines for protection from pneumoconiosis producing agents C2> Spr.iv `.Min <>jn-ra t o i siiould weaar proteerive i>l 1: I v.- w; Ii :: ;;p<v '< nr