Document 867vLDxMg7LjXQ0oqgjp4dw5
Heaters, Unit
Young Radiator Company
Unit Heaters, Convection Heaters, Blast Heaters, Heat Transfer Surfaces, Unit Coolers
Representatives in all Principal Cities
PIUHome Office:
AHA*Racine, Wis.
Sectional view of plastered-in enclosure
Young Streamaire copper convectors are furnished with plasteredin type enclosures, metal front recess cabinets, wall-hung cabinets and free-standing cabinets. These present a pleasing appearance, are solidly built, extremely compact and highly efficient in opera tion. The patented construction of Young Streamaire convectors insures positive satisfaction when operating on vapor, vacuum, or one-pipe steam systems or on gravity or forced circulation hot water systems.
Recess Cabinets Free-Standing Cabinets
Unit Heaters
Type "SH" for Steam or Hot Water --to heat garages,
Are availabe in various sizes and capaci ties to fill every heating need. They offer a complete compact enclosure for the heating element.
stores, industrial, and
similar type build
ings. Made in 17 dif
ferent models, equip
ped with constant or
multi-speed motors.
Recirculating ducts,
wall boxes, and heat diffusing nozzles can
Unit Heater
be furnished with all models; also air filters
Free Standing Cabinet
Unit Coolers
when desired. DeLuxe models have chro mium plated housings.
Type "VH" Slow fan speed and low power cost as sures quietness and economy in this model. Blower type fans circulate a large volume of heated air. An ideal unit to operate in conjunction with air ducts.
Blast Heaters and Commercial Units
. Types "XC" and
"SC" --Made with
two types of coils,
one for use with ice
water or brine as the
cooling medium, and
` one for direct expan sion use in connec
Unit Cooler
tion with refrigerating machines using re
frigerants such as sulphur dioxide, methyl
chloride, F 12, ammonia, etc., where they
are to be used to maintain room tempera
tures above the freezing point.
Blast Heater
Made with heavy seam less copper tubes and cop per fins (extended heating surface). Ideal for use with forced air heating and ventilating systems. For use with high and low steam pressures or with hot water. Designed so that all internal strains due to expansion and con traction are eliminated. Write for catalogue giving sizes and capacities.
Evaporators and Condensers
Selected by prominent manu
facturers i
of refrig-
era ti ng
and air
condi
tion ing
equipment for
Evaporator-Condenser
special, heavy service and exceptional ap plications. A great variety of tool; die and assembly equipment is available to manu facture these units to meet almost any specification.
692
Heaters, Water
Bell & Gossett Company
3000 Wallace Street
Steam and Vapor
Chicago, 111.
B & G Indirect Water Heaters for Steam and Vapor Systems
Description
SINGLE COIL For residences of all sizes. Duplex apartments and small buildings.
DOUBLE COIL For larger apart ments, garages, medium sized fac tories and office buildings.
TRIPLE COIL For heavier re quirements.
DOUBLE TRIPLE COILS
No.
30 40 52 66 82 100 120 144
Max.
Capacity Gallons
Length Inches
30 11% 40 12V,
52 u>/
i%66
82
100 2oy. 120 22!/, 144 25'/,
Max. Width Inches
5* 5XS 7'/, 7'/. 7'/, 7'/a 7'/t 7'/
Shell . Coil Shipping Openings Openings Weights
Inches Inches Pounds
1 yi
1%
1%
V/2 1
18
1 1
-1
vA: 1
12 13 15 29 39 40 42 46
160 160 12
H'/z
2
iig192 192 I43/,
300 300 I9ji
2 2
400 400 23Ve ii 'A 2
I'/z 53 i . 59
78
V/l 86
600 800 1000
1200 1600 2000
600 800 1000
1200 1600 2000
2P/ 2sy, 29'/,
23>/, 271/z 3oy,
isy, isy, isy.
29 29 29
3 3 3
4 4 4
I'/l 230 2'/z 250 2'/z 290 3'/z 568 3'/z 642 3'/z 716
AIj'.'Vv ratings based on 100 degree rise in three hours with boiler water temperature of 180 degrees or more.
HOT WATER--B & G Triple Duty Systems for Hot Water Systems
These three units comprise the Triple Duty System
Recommended No. Tank Sizes
19 30 to 42 Gallons 20 42 to 52 Gallons 21 52 to 66 Gallons 22 66 to 120 Gallons 23 120 to 180 Gallons 24 180 to 300 Gallons
Recommended Number of Baths
1 2 3 4 5 6
Important--This system will furnish year round domestic hot water supply from any oil, gas. stoker or hand fired hot water heating
boiler.
BOOSTER- -Automatic Electrically Operated Circulator with Positive Centrifugal Pump Action
No. Type Flange Size
Capacity
Motor
Style
l'/z-30 industrial ll/2 Inches
l'/2-30 Residential l'/2 Inches 2-50 Industrial 2 Inches
2-50 Residential 2 Inches
3-100
3 Inches
30 Gallons per Min.
30 Gallons per Min. 50 Gallons per Min.
50 Gallons per Min. 100 Gallons per Min.
1/8 H.P. Repulsion Induction
1/8 H.P. Capacitor 1/6 H.P. Repulsion
Induction
1/6 H.P. Capacitor. 1/4 H.P. Capacitor
B & G THERMO-CHECK
Controls automatically the temperature of hot water storage tanks heated by indirect heaters. A simple device that-requires no attention and. also eliminates lime and sediment formation in the heater coils. Sizes
and 2".
B & G Motorized Valves--Sizes 2" to 6" in both Straightway and Angle Patterns
693
/