Document 867vLDxMg7LjXQ0oqgjp4dw5

Heaters, Unit Young Radiator Company Unit Heaters, Convection Heaters, Blast Heaters, Heat Transfer Surfaces, Unit Coolers Representatives in all Principal Cities PIUHome Office: AHA*Racine, Wis. Sectional view of plastered-in enclosure Young Streamaire copper convectors are furnished with plasteredin type enclosures, metal front recess cabinets, wall-hung cabinets and free-standing cabinets. These present a pleasing appearance, are solidly built, extremely compact and highly efficient in opera tion. The patented construction of Young Streamaire convectors insures positive satisfaction when operating on vapor, vacuum, or one-pipe steam systems or on gravity or forced circulation hot water systems. Recess Cabinets Free-Standing Cabinets Unit Heaters Type "SH" for Steam or Hot Water --to heat garages, Are availabe in various sizes and capaci ties to fill every heating need. They offer a complete compact enclosure for the heating element. stores, industrial, and similar type build ings. Made in 17 dif ferent models, equip ped with constant or multi-speed motors. Recirculating ducts, wall boxes, and heat diffusing nozzles can Unit Heater be furnished with all models; also air filters Free Standing Cabinet Unit Coolers when desired. DeLuxe models have chro mium plated housings. Type "VH" Slow fan speed and low power cost as sures quietness and economy in this model. Blower type fans circulate a large volume of heated air. An ideal unit to operate in conjunction with air ducts. Blast Heaters and Commercial Units . Types "XC" and "SC" --Made with two types of coils, one for use with ice water or brine as the cooling medium, and ` one for direct expan sion use in connec Unit Cooler tion with refrigerating machines using re frigerants such as sulphur dioxide, methyl chloride, F 12, ammonia, etc., where they are to be used to maintain room tempera tures above the freezing point. Blast Heater Made with heavy seam less copper tubes and cop per fins (extended heating surface). Ideal for use with forced air heating and ventilating systems. For use with high and low steam pressures or with hot water. Designed so that all internal strains due to expansion and con traction are eliminated. Write for catalogue giving sizes and capacities. Evaporators and Condensers Selected by prominent manu facturers i of refrig- era ti ng and air condi tion ing equipment for Evaporator-Condenser special, heavy service and exceptional ap plications. A great variety of tool; die and assembly equipment is available to manu facture these units to meet almost any specification. 692 Heaters, Water Bell & Gossett Company 3000 Wallace Street Steam and Vapor Chicago, 111. B & G Indirect Water Heaters for Steam and Vapor Systems Description SINGLE COIL For residences of all sizes. Duplex apartments and small buildings. DOUBLE COIL For larger apart ments, garages, medium sized fac tories and office buildings. TRIPLE COIL For heavier re quirements. DOUBLE TRIPLE COILS No. 30 40 52 66 82 100 120 144 Max. Capacity Gallons Length Inches 30 11% 40 12V, 52 u>/ i%66 82 100 2oy. 120 22!/, 144 25'/, Max. Width Inches 5* 5XS 7'/, 7'/. 7'/, 7'/a 7'/t 7'/ Shell . Coil Shipping Openings Openings Weights Inches Inches Pounds 1 yi 1% 1% V/2 1 18 1 1 -1 vA: 1 12 13 15 29 39 40 42 46 160 160 12 H'/z 2 iig192 192 I43/, 300 300 I9ji 2 2 400 400 23Ve ii 'A 2 I'/z 53 i . 59 78 V/l 86 600 800 1000 1200 1600 2000 600 800 1000 1200 1600 2000 2P/ 2sy, 29'/, 23>/, 271/z 3oy, isy, isy, isy. 29 29 29 3 3 3 4 4 4 I'/l 230 2'/z 250 2'/z 290 3'/z 568 3'/z 642 3'/z 716 AIj'.'Vv ratings based on 100 degree rise in three hours with boiler water temperature of 180 degrees or more. HOT WATER--B & G Triple Duty Systems for Hot Water Systems These three units comprise the Triple Duty System Recommended No. Tank Sizes 19 30 to 42 Gallons 20 42 to 52 Gallons 21 52 to 66 Gallons 22 66 to 120 Gallons 23 120 to 180 Gallons 24 180 to 300 Gallons Recommended Number of Baths 1 2 3 4 5 6 Important--This system will furnish year round domestic hot water supply from any oil, gas. stoker or hand fired hot water heating boiler. BOOSTER- -Automatic Electrically Operated Circulator with Positive Centrifugal Pump Action No. Type Flange Size Capacity Motor Style l'/z-30 industrial ll/2 Inches l'/2-30 Residential l'/2 Inches 2-50 Industrial 2 Inches 2-50 Residential 2 Inches 3-100 3 Inches 30 Gallons per Min. 30 Gallons per Min. 50 Gallons per Min. 50 Gallons per Min. 100 Gallons per Min. 1/8 H.P. Repulsion Induction 1/8 H.P. Capacitor 1/6 H.P. Repulsion Induction 1/6 H.P. Capacitor. 1/4 H.P. Capacitor B & G THERMO-CHECK Controls automatically the temperature of hot water storage tanks heated by indirect heaters. A simple device that-requires no attention and. also eliminates lime and sediment formation in the heater coils. Sizes and 2". B & G Motorized Valves--Sizes 2" to 6" in both Straightway and Angle Patterns 693 /