Document 85YzQNYnOGOwpom9QZadXa12a
December 3, 1992
Dow U.S.A
The Dow Chemical Company P 0 Box 150
PlaQuemme Louisiana 70765-0150
Daniel Cortez Petrin Building 4106
cc: Wayne Russell
Cellulose
Building 4501
Asbestos Monitoring
Enclosed are sample results for potential exposure to asbestos.
The OSHA 8-hour permissible exposure limit for asbestos is 0.2 f/cc >5 microns and the 30-minute short term exposure limit is 1 f/cc >5 microns.
The results displayed are based on sampling duration.
The data sheet shows the results of exposure using two methods, the Limit of Detection (LOD) and the Limit of Quantitation (LOQ). Included on the data sheet is an explanation of the method Limit of Quantitation.
Darlene S. Creel Industrial Hygiene Ext. 6181 Building 3502-W
Attachment dsc
-------------------- t*"\SE
DO A 11.F065 CONFIDENTIAL
CT . 4
i
LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD
PLANT/DEPT. MONITORING FOR: W-g-AvT?:
>-*
DATE
^
OTHER CHEMICALS PRESENT:
SAMPLE N2 15 452
TEMP. 7^
DEGREE F
SAMPLE COLLECTION MEDIA:
BADGE NO._____
CHARCOAL TUBE 0^FILTER CASSETTE
SILICA TUBE DRAGERTUBE OTHER _______
SIZE. SIZE, SIZE _ TYPE
HUMIDITY T'-S" 32? TYPE
SHIFT: DlO HR.
12JJR. 0^HR.
0"'pPEEIRSONNEL SAMPLE FULL SHIFT TWA STEl/TASK
AREA SAMPLE /tT-2Q WIND DIRECTION
EMPLOYEE NAME.
EMPLOYEE I.D.#_
JOB CLASSIFICATION
IiHn JJOVDB CV.O01D2EC #tf __________________________ y* r -
.
CONTRACTOR COMPANY
LcT1--------
RESPIRATOR USED? STYES NO
RESPIRATOR MODEL / CANISTER TYPE _
MOUTH-BIT
DUST
77^ '"half-face
FULL-FACE
AIR-LINE SCBA
DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING.
/6 +
7^
PUMP SERIAL NO. CALIBRATION DEVICE:
&6UBBLEMETER OTHER
ROTAMETER
PUMP FLOW RATE CALIBRATION: BEGIN. 1. 2
BEGINNING FLOW RATE AVG>^Z J O^CC/MIN L/MIN
ENDING:"!. XUttU
<2-434
ENDING FLOW RATE AVG. X2 Ift/f) gKcCTMIN L/MIN
SAMPLE AVERAGE FLOW RATE
ZjLJlL-JlT
TIME STARTED
P^3Z>
TIME STOPPED
Zf 'riD
TOT. RUNNING TIME(MIN)
-- `7/2
>
SAMPLE VOLUME (AVG FLOW X RUN TIME) '7,7#
ANALYTICAL RESULTS:
* RESTRICTED FOR USE WITHIN DOW ONLY * r
VP-124
FORM FILLEEDD IN BY:
C
DO 11DO ho COi-'IF T DFN F f 01
ASBESTOS MONITORING DATA RESULTS: CELLULOSE 1992
DATE SAMPLE# PERSONNEL DESCRIPTION
11/11/92
15452
*433-23-2653 INSULATOR: Removing 16# of broken transits WET METHOD USED
**LOD ***LOQ
EXPOSURE GUIDELINES 8-HR. TWA LIMIT - 0.20 FIB/CC 30-MINUTE LIMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2
DUR/M1N1 VOLfL)
** LOD FIB/CC
***LOQ FIB/CC
30
72
0.02
<0.53
* The proper protective clothing was worn during the job. North 7700 Half-face Respirator with HEPA filters were worn during the job.
Note: The Limit of Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loading criteria specified. In the NIOSH analytical method 7400, the stated range of the method is 100 to 1300 Fibers/MM2 filter area. Although samples below this range can be analyzed, the method has not been validated below 100 Fibers/MM2. However, the NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Fibers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this information, we will establish 100 Fibcrs/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 filter area as our Limit of Detection (which is more representative of the actual fibers present) for asbestos monitoring. We will report both limit of Quantitation and Limit of Detection.
If only Limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 8-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute.
DO A 110007 CONFIDE7NTT Al.