Document 85RyyJ8b7LD2kowKDNMNraM4d

ABERDEEN CHEMICAL PLANT ROUTINE CHEMICAL DOSIMETRY SUMMARY A MONTH OF: August, 1981 DATE OF REPORT: September 10, 1981 c: CLM, CRM, PEM, JRM, RDJ, TBD, SJV, RAF, RAM,(^H/ T. G. Grumbles - Houston, 0. D. Steffey - Portea-D i t y ALL SAMPLE RESULTS: Chemical VCM Lead Antimony Total Particulates OVEREXPOSURES: PEL No. % 74 90 15 94 16 100 6 86 PEL OVEREXPOSURES No. % 8 1 0 1 Job Class Exposure Source General Mechanic 2.3 ppm VCM Specific cause not identified General Mechanic *2.7 ppm VCM Employee blanked out D-500 reactor Vinyl Operations Engineer 2.7 ppm VCM VCM leak through sewer valve @D-500 Vinyl Shift Supervisor 3.6 ppm VCM Specific cause not identified Vinyl Lead Operator 7.8 ppm VCM Specific cause not identified General Mechanic *9,. 4 ppm VCM Employee helped change VCM recovery compressor, V-ll Vinyl Chief Operator General Mechanic 10.1 ppm VCM *19.1 ppm VCM Compounder Dry Blend Utility *49.6 Micrograms Lead/M *20.1 Milligrams total Dust/M^ * Respiratory pjnptection worn Blown seal on recovered VCM charge pump. a Changed safety discs>north south seal water separators, new vinyl unit Specific cause not identified Employee charged Master Batch G cleaned area. Upta VAB.0001073490 %< PEL 100 VCM 0 100 Lead 0 ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS VAB.0001073491