Document 85Qe1L3ZZ32oZ4vJQqkE1XnRe

TO: C. R. Lowe/Zono-Atlanta ,, R. L. Asher/Zono-Boca Raton R. E. Dunham/Zono-Minneapolis Office W. G. Gray/Zono-Dearborn W. K. Rogers/ C. H. Wendel/Zono-Los Angeles Office E. D. Bossier/Zono-New Orleans L. A. White/Zono-Nashville } R. G. Hartman/Zono-New Castle V. G. Monroe/Zono-Wilders T. E. Dietrick/Zono-Atlanta . L. F. Kollis/Zonc-Kigh Point \j. Cintani/Zono-Trenton T. Burns/Zono-Beltsville A R. McLeod/Zono-Minneapolis Office JJ N. McDougall/Zono-Onaha W. J. Sinacore/Zono-Chicago Plant A. W. Dambros/Zono-Los Angeles Office T. W. Pickthall/Zono-Newark W. V. Culver/Zono-Auburn J. V. McKague W. F. Hunter/F. Hyde (Ontario) Ltd. S. K. Vallieres/F. Hyde and Co., Ltd. R. B. Moran/Texas Vermiculite Co. J. H. Greer/Vermiculite Products Co. J. Lyall/Southwest Vermiculite Co. L. K. Irvine/Vermiculite-Intermountain, Inc. F. E. Gebert/Robinson Insulation Co. N. F. Bushell/Grant Industries A. D. Webster/F. Hyde and Co., Ltd. R. W. Sterrett T. P. Feit R. M. Vining K. Harrison B. R. Williams J. N. Beveridge J. C. Ottinger R. 0. deBastian/Zono-St. Louis W. J. Bourke/Zono-Chicago Plant ZCNC'JTE DIVISION ST. LOU'S. MO. 631'' 25053645 ZONOLITE cos'stiuxtion rnonvcTs division TO: See Distribution List FROM: T. F. Egan DATE: March 24, 1971 Gentlemen: Most of you are aware by now that we are being included in the term "Spray Fireproofing" which is getting a bad name from recent fires in high-rise office buildings. An article in Engineering News Record, March 11, 1971, noted comments by W. R. Powers of New York Fire Underwriters and recent opinions of the New York Fire Rating Organization (See Attached). I and others are attempting to refute these charges which include Mono-Kote in the indictment against sprayed fibers. A previous article in Engineering News Record, November 26, 1970, from which we made data sheets (see attached) noted what Powers stated in his official report. It's important that you make clear to everyone that the fires in New York and the charges against failure of spray material is SPRAYED FIBERS. Further, I urge that you contact the local rating bureaus noted on the attached list and state your case for Mono-Kote. It would be wise to talk in terms of types, e.g., Cementitious (plaster) vs sprayed fibers and not use brand names. Petition that the rating officials make judgments on known facts which are that the sloppy application procedures permitted in New York along with the poor physical properties of sprayed fibers combined to make the situation in New York criminal. I'm attaching copies of some letters to insurance officials that may be of help in stating our case. I am writing a similar letter to each of these bureaus and will send a copy to you. Would you please help by making contact and reporting the results. Also, if you have contacts in insurance circles, let them know the facts and advise if and how I can help. To achieve success, the job must be done by everyone at all levels and at the same time. Don't delay and don't be afraid of talking straight to the facts. Thanks and I'll be waiting to hear from you. Yours truly 250536*6 ZONOLITE CONSTRUCTION PRODUCTS DIVISION atirf. March 23, 1971 Mr. Hobart E. Fountain New York Fire Insurance Rating Organization 130 William Street New York, New York 10038 Dear Mr. Fountain: I recently received a list of rating offices from Mr. Bechtolt of the Fire Insurance Research and Actuarial Association, and he asked what our company was doing about the sprayed fireproofing situation. My reply is attached. I'm sending it along to you, Mr. Fountain, because I'm disturbed at our cementitious material being indicted by the charges being leveled. As I mentioned when I met with you, that what you are seeing when you look around New York is sprayed fibers on 90% of the work. Further, this material is being applied today as poorly as ever, in spite of our concern, because no one is doing enough to make sprayed fiber applications meet standards. Recent articles, particularly the one in Engineering News Record of March 11 in which your organization is mentioned, include cementitious in the term spray-applied material. I would hope that some statement could be made to note a difference between cementitious and sprayed fiber. They are not alike; and if you're comparing, you might want to note that the recent fire in the Bank of America Building in San Francisco, protected with Mono-Kote, had none of the'damage.in curred in the two New York fires where sprayed fibers were used. I'm sure Mr. H. Spaeth of the Pacific Fire Rating Bureau could relate to these facts. It should not be unusual to note differences in type of protective materials, particularly when one is able to see the differences in properties, application and performance. 25053b*7 [iaRAo'cj ZONOLITE CONSTRUCTION PRODt?CT8 DIVISION Mr. Hobart E. Fountain -2- V:Q. March 23, 1971 As I noted earlier, I'm anxious to meet with you and others at any time to further clarify our position or be of service and assistance in this matter. TFE/jac Attachment 25053b*8 ZONOLITE CONSTRUCTION PRODUCTS DIVISION March 23, 1971 Mr. P. R. Bechtolt Fire Insurance Research And Actuarial Association 160 Water Street New York, New York 10038 Dear Mr. Bechtolt: In your letter of February 8, you asked what Zonolite has done or is contemplating doing to insure that our product will be properly applied. As a means of answering that, I will first explain that our product Mono-Kote is a Cementitious (Plaster) sprayed fireproofing. This is very much different from the sprayed mineral fiber types which have caused so much controversy not only in the area of improper application but in pollution. Mono-Kote, being cementitious and having gypsum plaster as a binder, is wet mixed, pumped and sprayed. The binder takes a chemical set, locking all the ingredients in a hardened mass and always providing an in-place density in accordance with those shown in the particular fire test assembly. This is not the same with sprayed fibers since they are mixed dry, blown to the nozzle and wetted as sprayed. The control of water and feed rate at the nozzle directly affects the in-place density. This has been of concern to us, of course, but for a long time others have made note of this condition but little heed has been taken. As an example, I quote from Document No. 3 of the Construction Specifications Institute titled "Specifying Sprayed Fireproofing", Installation Methods Section G, paragraph Gl, "With fibrous materials accurate water measurement is highly important. A common way to cheat on the application is to reduce the water flow at the nozzle, thus decreasing density and increasing coverage per pound of fiber." 25053649 ZONOLITE CONSTRUCTION PRODUCTS DIVISION Mr. P. R. Bechtolt -2- 1 ' 1 * o I li March 23, 1971 For years, the almost total concern for getting lower in-place costs overcame any regard for proper application. There were and are few guidelines by legislation or code. Also, these few regulations were seldom, if ever, enforced. Therefore, the rules of conduct were how fast and how cheap. Like many things that go on long enough, they become accepted by those who never see how or what others in different areas are doing or are required to do. The two basics of applications are: (1) Thickness and (2) Density. Since the density is assured with cementitious material, then rela tively simple tests for thickness can be regularly performed by government, insurance, or owner/architect inspection. For sprayed fibers the additional requirement for density should be enforced. As stated earlier, Zonolite, as part of Construction Products Division of W. R. Grace & Co., has been striving for years to enlist others in control measures on application of sprayed materials, particularly with fibers. Some areas, particularly the Pacific Coast area, have been following stricter regulations on approval and in-place inspection. It's interesting to note that the overwhelming majority work in these areas is cementitious. Noting further that the Uniform Building Code requires time-temperature on beams and cities like San Francisco require pre approval testing for damageability, make the criteria of performance strict. It has been our feeling and we have urged that inspection of thickness and/or density be handled by an independent laboratory. Attached you will note our data sheet where in our specifications we make clear in red a recommendation for density tests. We are increasing our efforts to call attention to the need of proper fire-protection with all responsible segments. Now that the insurance people are looking directly at the application and damageability question, we are anxious to cooperate. Also attached is an "Inspection Guide" that we have prepared for code and other inspectors. It is hoped that these will be of assistance in bringing some clarity to a very confusing matter. 25053650 ZONOLITE CONSTRUCTION PRODUCTS DIVISION Mr. P. R. Bechtolt -3- March 23, 1971 It would be easy to say "You got what we have told you you'd get by allowing sprayed fibers to be installed with no control." We will say it but offer our talent and effort in cooperation with you and others so together we can provide proper protection in accord with codes and insurance ratings. Also, that the unfair advantage gained by inferior fireproofing will be stopped. In summation, I contend that "sprayed fireproofing" should not be taking the brunt of indictments, but that sprayed fiber application practices should be noted and distinction be made by the insurance rating agencies and officials whether spray protection is provided by (a) cementitious or (b) sprayed fiber types. Realizing that some or most of this may be confusing, I am asking that you allow me to speak in person to you and any other interested parties at your convenience. If this is satisfactory, please advise, and I'm sure that with some open question and answer, all the facts can be examined. TFE/jac Attachment 25053651 \\ ; '-- -'a \-- . t- _1 - Unprotected steel Dearn oefiectea and sheared connection Doits Fire hits three floors of SO-story Deluding Construction industry seeks answers to problem of fire in tall buildings The construction industry quite sud denly is wrestling a problem manv con sidered almost nonexistent--fire in high-rise buildings. The problem ex isted, but it was hidden bv the descrip tion, "fire-resistive building." Owners, designers and builders equated building safety with life safety. To some extent the two do overlap, so the industry overlooked the significance of events. Two events in the earlv !960s were as dramatic as thev were significant. On Thanksgiving eve in 1961. a fire raged in the third basement of the 24-storv Times Tower in New York Cats s Times Square. The blaze was held to that basement, but two firemen died--on the 22nd floor .Smoke got them Also killed was a building service cmplosec. He was trapped in an elevator sturk be- tw ecu t he hisi nd second lit M Smoke go: him Two l.itei foul c a v - after Chi i-tn la* lire k die 1-i ! f m Hu- tel Row 11, J.H kv <n\ i lie FI Fire- men co n!; 11111* d tin bl :\y v m lie lobbs ss lieu i;; M.i icd . bill J. SO! K f iied. all on floo I''* M\ t hio u ' h Id Mlh ike got them Hot!. build in U - ( .1 Freer c's i'll t steel <n:;i if 1 Cl( : ' 1; > l! IK i1 >n. \\ < ! t <tected in the early 1900s so the fatalities per haps were attributed to design features long since abandoned and to use of older combustible materials. The Times Tower, for example, had open stairways that distributed dense smoke throughout the building. But last year fire hit three hich-rise buildings. All are new. all use the most modern materials and all employ the latest design techniques. One fire involved San Francisco's Bank of America Building, a 52-storv office structure occupied earlv in 1969. The fire, of inccndiars origin, was con tained where it started, in a 35th floor lounge. Furniture and some interior finishes wrre destrosed in the fire area. There was some smoke damage on a feu upper floors, but no structural damage. The other two fires, in New York flits. killed five persons. One. in midtoun. Manhattan, occurred in a 47sum smicture knout) as the Carpet Center Building, and the oilier was in a :>U-stor\ building at One New York Pia/a in luuer Manhattan's financial district. Tenant finishing work was still under was on some floois in both buildings Three building wot kers died in the Carpet Center fire, two in the hall on the fifth floor, the fire floor, and one in an elevator stuck at the fire floor. The fire at One.New York Plaza killed tsvo building employees, both in an elevator stuck at the 33rd floor, lowest of the three fire floors. Lowering the boom. The New York Board of Fire Underwriters and its su perintendent, W. Robert Powers, a li censed professional engineer, soon after issued reports that jarred the construc tion industry , the steel industry, and the elevator industry. Among other things. Powers urged installation of automatic fire sprinklers throughout high-rise office buildings, use of fireproofing material other than the spray-applied mixes on steel frames, and use of elevator call buttons of a tvpe that would not call a car to a flooi because of heat, smoke and flames. The insurance industry responded rapidly. The New York l ire Insurance Rating Organization, a service organi zation in New York State for about 250 insurance companies, issued an advi sors opinion eUcciivc 1 eb I. that steel flame stiuciuies be considered for in suring purposes as unprotected steel if spias -applied m.ileiia! w used fin fire proofing It is believed that the change If '`091.37$ I In another tower, smoxe -ose 10 toe inside could double premium charges for fire insurance policies on buildings. Expensive alternates. Alternates to spray-applied fireproofing are ex pensive. Concrete encasement costs over 10 times more than sprav-applied fire proofing, according to Ira Hooper, of Seelye. Stevenson. Value & Knecht. New York Citv consulting engineers. As an example. Hooper sa\s encasement of a W 16 X 36 beam would cost about S8 per lin ft as against 73 cents per lin ft for spray-applied fireproofing. Troweled plaster on lath would cost seven times more than spraving. and in- tumescent mastic would cost eight times more. The steel industr\ fears that if builders'are forced to go to concrete-en cased steel iljev might move all the wav to reinforced concrete. Hooper has of fered the steel producers a wav out of the potential competitive problem. He sugu'C't' that the steel industrv develop prefabricated fire-rated assemblies for enclosin'.' steel membos m buildings. Steel companies might, however, find that the Fire Rating Organization is willing k. com pm mi-" on the use of sprav-appii: d firenn g materia!1 Since i: ii ci r- art-.;; a . opinion, u has ciretdater' po-.p-'.:; fnr steel maker- anc. b . iciei- that would main: the sp-a-. ;.i!j a. crpiahie Ihi-could F: .'Ccomnli-'Meci prm-Kl::! a suirrr of msiv-rtion1 and ic-ung was f s:. i: a 11 s}, c.; Oi" c-uid;: 1C:'-, would r.- tiu'r'- da 5' .i:';vc't-t . \ -u- i-spr.iv i:;g Sprinkler protection. The recommen dation that automatic sprinklers be in stalled throughout high-rise office buildings ir supported bv fire depart ments and insurance companies. In ad dition to serving as a prime protector of life, sprinklers also rank as a top prop erty-protection svstem. Reaction of the builders appears mixed. Owners contend that the cost of sprinkler installation is high. Some also claim that activation of a system causes heavy water damages. Sprinkler system designers, manufac turers and installers scoff at both claims. They say the sharplv lower fire insurance premiums that usuallv pre vail for fully sprinklcrcd buildings can amortize the cost of a svstem in less than 10 years, usuallv five or less. They say that water damage is slight compared to the damage done bv a fire and fire-fightinc requirements. Thev note that one sprinklci operating at 75 psi deliver1 about 50 gpm. while a 2Din. hose operating at the same pressure dclivers about -100 gpm. Also the number of heads activated bv an office fire probablv will be small. Data gathered over the last 1 0(1 vears of sprinkler historv show that 57.1" of all fire1 that activate a sprinkler arc con trolled bv one head. 73.-1'"- arc con trolled bv five or fewer sprinklers and B3r In Kinrfcwci sprinklers Other cost offsets also mas be avail able m diteei construction ouil.tvs in some geographic areas uiid' t some circuir-ian-cs Last vear the Southern Standard Building Code, a model code published by the Southern Building Code Congress (SBCC), and used in various communities of 22 southern and southeastern states was revised to reduce required fire ratings bv one hour on commercial buildings if a sprinkler svstem is installed throughout a build ing. A four-hour rating would drop to three hours, a three-hour rating to two and a two-hour rating to one. No mate rial rating would go below one hour. Sprinkler industry spokesmen say that such changes could reduce some build ing costs by up to 25T. Those who argue against reliance on a sprinkler system say that a smoky fire frequently will not produce enough heat to activate sprinklers. They say that this means the most deadly prod uct of a fire, smoke, will in some cases increase and spread uncontrolled. (Continued on p. 22) Office floor ; ro. .: 3. are l j l IT> <0 IT O ar> LIST OF FIRE RATING ORGANIZATIONS 1971 INSURANCE SERVICES OFFICE (formerly compiled by FIRE INSURANCE RESEARCH and ACTUARIAL ASSOCIATION) 160 Water Street, New York, N. Y. 10038 January, 1971 25053654 Alabur,a Inspection & Rating Bureau L. Vernon Cantey, Manager Washington Building, 125 Washington Street P. 0. Box 80 Montgomery, Alabama 36101 Phone: (205 ) 264-7331 Alaska Pacific Fire Rating Bureau H. S. Morr, General Manager 465 California Street San Francisco, California 94104 Phone: (415) SU 1-8828 Arizona Fire Rating Bureau (Division of Pacific Fire Rating Bureau) Arvie Korstad, Manager 3500 North Central Avenue Phoenix, Arizona 85012 Phone: (602) 264-7021 Arkansas Inspection & Rating Bureau W. M. Harman, Manager 600 Tower Building, P. O. Box 2661 Little Rock. Arkansas 72203 Phone: (501) FR 6-1381 California Pacific Fire Rating Bureau H. S. Morr, General Manager 465 California Street San Francisco, California 94104 Phone: (415) SU 1-8828 Colorado Mountain States Inspection Bureau R. H. Harmon, Manager 910 15th Street P. O. Box 1740 Denver, Colorado 80201 Phone: (303) TA 5-6191 Connecticut New England Insurance Rating Association Robert H. Stocker, Jr., Executive Manager Three Center Plaza P. O. Box 2057 Boston, Massachusetts 02106 Phone: (617) 742-9560 Delaware Middle Department Association of Fire Underwriters Richard M. Kennedy, Executive Manager Public Ledger Building Philadelphia, Pennsylvania 19106 Phone: (215) MA 7-6800 (2) ?< 3 *3S0 District of Columbia Insurance Rating Bureau of The District of Columbia Kenneth R. Underwood, Manager 840 Woodward Building Washington, District of Columbia 20005 Phone: (202) NA 8-1230 Florida Inspection & Rating Bureau Arthur B. Jones, Manager 35 South Hogan Street P. O. Box 539 Jacksonville, Florida 32201 Phone: (904) 356-4201 Georgia Inspection & Rating Bureau Grayson H. Parker, Manager 1577 Northeast Freeway, N.E. P. O. Box 29851 Atlanta, Georgia 30329 Phone: (404) 633-4171 Hawaii Insurance Rating Bureau Frank H. Kuhn, Secretary Fire 700 Bishop Street 5th Floor, P. O. Box 4500 Honolulu, Hawaii 96S13 Phone: 531-2771 Idaho Surveying & Rating Bureau, Inc. W. S. Hayes , Manager 1007 West Jefferson Street P. O. Box 1069 Boise, Idaho 83701 Phone: (208) 343-54S3 Illinois Inspection and Rating Bureau F. R. Marcon, Manager 175 West Jackson Boulevard Chicago, Illinois 60604 Phone: (312) WA 2-4281 Indiana Rating Bureau Ernest S. Pavy, Manager 320 North Meridian Street Indianapolis, Indiana 46209 Phone: (317) ME 4-5305 Iowa Inspection Bureau Glenn VV. Bondesson, Manager 414 Insurance Exchange Building Des Moines, Iowa 50308 Phone: (515) AT 8-0203 Kansas Inspection Bureau M. E. Stubbs, Manager 625 Polk Street Topeka, Kansas 66603 Phone: (913) CE 4-3405 (3) v. r 25053655 Kentucky Inspection Bureau Joe D. Smith, Manager 940 Starks Building Louisville. Kentucky 40202 Phone: (502) 587-1343 Louisiana Rating & Fire Prevention Bureau Edwin T. Mitchell, Manager P. O. Box 60730 1300 Pere Marquette Building New Orleans, Louisiana 70160 Phone: (504) JA 5-2391 Maine New England Insurance Rating Association Robert H. Stocker, Jr., Executive Manager Three Center Plaza P. O. Box 2057 Boston, Massachusetts 02106 Phone: (617) 742-9560 Maryland Fire Underwriters Rating Bureau Arthur C. Muhiy, Executive Manager First National Bank Building Light & Redwood Streets Baltimore, Maryland 21202 Phone: (301) LE S-3554 Massachusetts New England Insurance Rating Association Robert H. Stocker, Jr., Executive Manager Three Center Plaza P. O. Box 2057 Boston, Massachusetts 02106 Phone: (617) 742-9560 Michigan Inspection Bureau P. H. Kesselring, Manager 4000 Cadillac Tower (Zone 26) Box 2719 Detroit, Michigan 48231 Phone: (313) WO 5-1300 Minnesota Fire Underwriters Inspection Bureau \V. C. Freitag, Manager 12 South Sixth Street Minneapolis, Minnesota 55402 Phone: (612) FE 2-7401 Mississippi State Rating Bureau C. Burnell Egger, Manager 900 Bankers Trust Plaza Building P. O. Bex 1790 Jackson, Mississippi 39205 Phone: (601) 948-7030 (4) Missouri Audit Bureau W. M. Brown, Superintendent 1301 Pierce Building St. Louis, Missouri 63102 Phone: (314) MA 1-3715 709*3$ Missouri Inspection Bureau T. E. Scott, Manager 1400 Pierce Building St. Louis, Missouri 63)02 Phone: (314) MA 1-0380 Montana Fire Rating Bureau (Division of Pacinc Fire Rating Bureau) J. J. O'Leary, Manager 308 Strain Building Great Falls, Montana 59401 Phone: (406) 453-2428 Nebraska Inspection Bureau Emil C. Wagner, Manager 3016 Harney Street Omaha, Nebraska 65131 Phone: (402) 346-8633 Nevada Pacinc Fire Rating Bureau H. S. Morr, General Manager 465 California Street San Francisco, California 94104 Phone: (415) SU 1-8828 New England Insurance Rating Association Robert H. Stocker, Jr., Executive Manager Three Center Plaza P. O. Box 2057 Boston, Massachusetts 02106 Phone: (617) 742-9560 New Hampshire Board of Underwriters Carl B. Smith, Jr., Secretary & Treasurer 105 Loudon Road Concord, New Hampshire 03301 Phone: (603) CA 5-2703 New Jersey Fire Insurance Rating Organization of New Jersey T. M. Boyd, General Manager 744 Broad Street Newark, New Jersey 07102 Phone: (201) MI 3-3600 New Mexico Mountain States Inspection Bureau R. H. Harmon, Manager 910 15th Street P. O. Box 1740 Denver, Colorado 80201 Phone: (303) TA 5-6191 (5) 25053656 New York Fire Insurance Bating Organization K. O. Smith, General Manager-Secretary 110 William Street New York. New York 10038 Phone: (212) WO 4-7060 North Carolina Fire Insurance Hating Bureau C. . Hibbard, Manager 226 South Dawson Street P. O. Box 2021 Raleigh, North Carolina 27602 Phone: (919) TE 4-4313 North Dakota Fire Underwriters Inspection Bureau W. C. Freitag, Manager 12 South Sixth Street Minneapolis, Minnesota 55402 Phone: (612) FE 2-7404 Ohio Inspection Bureau P. E. Seidelmann, Manager 431 East Broad Street, P. O. Box 1290 Columbus, Ohio 43216 Phone: (614) CA 6-5441 Oklahoma Inspection Bureau M. B. Rook, Manager 2000 Classen Bldg. P. O. Box 559 Oklahoma City, Oklahoma 73101 Phone: (405) JA 8-3421 Oregon Insurance Rating Bureau (Division of Pacific Fire Rating Bureau) H. E. Marqueling, Manager 721 SW Oak Street Portland, Oregon 97205 Phone: (503) CA 6-2651 Pennsylvania Middle Department Association of Fire Underwriters Richard M. Kennedy, Executive Manager Public Ledger Building Philadelphia, Pennsylvania 19106 Phone: (215) MA 7-6800 Puerto Rico Inspection & Rating Bureau Fernando Garcia Sharp, Manager P. O. Box 1333 San Juan, Puerto Rico 00902 Phone: 723-1830 Rhode Island New England Insurance Rating Association Robert H. Stocker, Jr., Executive Manager Three Center Plaza P. O. Box 2057 Boston, Massachusetts 02106 Phone: (617) 742-9560 (6) South Carolina Inspection & Rating Bureau Charles E. Koon, Manager 1332 Sumter Street P. O. Box 202 Columbia, South Carolina 29202 TftO. Phone: (803) 252-8661 South Dakota Fire Underwriters Inspection Bureau W. C. Freitag. Manager 12 South Sixth Street Minneapolis, Minnesota 55402 Phone: (612) FE 2-7401 South-Eastern Underwriters Association (Operates Bureaus in Ala., Fla., Ga. and S. C.) Robert P. Harris, Manager 1577 Northeast Freeway, N.E. P. O. Box 29972 Atlanta, Georgia 30329 Phone: (404) 633-4171 Tennessee Inspection Bureau C. N. Mullican, Jr., Manager 4304 Harding Road, P. O. Eox 127 Nashville, Tennessee 37202 Phone: (615) 298-3333 Texas State Board of Insurance Ned Price , Chairman Durwood Manford Charles D. Mathews Phone: (512) GR 5-3949 Commissioner of Insurance Clay Cotten 1110 San Jacinto Austin, Texas 7S701 Phone: (512) GR 5-2273 Utah Fire Rating Bureau (Division of Pacific Fire Rating Bureau) A. H. Bywater, Manager 1106 Boston Building Salt Lake City, Utah 84111 Phone: (801) DA 2-5567 Vermont New England Insurance Rating Association Robert H. Stocker, Jr., Executive Manager Three Center Plaza P. O. Box 2057 Boston, Massachusetts 02106 Phone: (617) 742-9560 (7) Virginia Insurance Rating Bureau E. D. Sommers, Manager 700 E. Mam Building P. O. Box 1193 Richmond, Virginia 23209 Phone: (703) MI 3-7471 Washington Insurance Examining Bureau. Inc. William S. Cunningham, Jr., Manager Alaska Building P. O. Box 3967 Seattle, Washington 98124 Phone: (206) MU 2-5111 Washington Surveying & Rating Bureau George W. Clarke, General Manager 1100 Alaska Building P. O. Box 1168 Seattle, Washington 98111 Phone: (206) MA 2-8353 Washington, D. C. (See District of Columbia) West Virginia Rating Bureau John K. Roberts, Manager 1120 Kanawha Boulevard East P. O. Box 626 Charleston, West Virginia 25322 Phone: (304) DI 2-0116 Wisconsin Fire Insurance Rating Bureau Roger C. Krafft, Manager 615 E. Michigan Street Milwaukee, Wisconsin 53202 Phone: (414) BR 6-3462 Wyoming Mountain States Inspection Bureau R. H. Harmon, Manager 910 15th Street P. O. Box 1740 Denver, Colorado 80201 Phone: (303) TA 5-6191 TO 2 (8) A i \ 25053656