i -2z : s8 O Q= =C/3 ' i! Ogu ; *<3 <>-*o> OZOLkhUoha 00 = o l oo -J 2 Oah-: <hO- OOC oi oo a=Ui<. Po <h-- <O 0>0< oo LQU o 276 MOTOR and WIRE RATING DATA Resistors -- Service Classifications and Recommendations SERVICE CLASSIFICATION OF RESISTORS A. Resistors shall be designated by class numbers in accordance with Tables 1, 2,3 and 4. B. Starting- and intermittent-duty resistors are primarily designed for use with motors which require an initial torque corresponding to the stated per cent of full-load current on the first point and which require an average accelerating current (rms value) of 125 per cent of full-load current. With a secondary-resistor alternating-current controller, the figures given in the tables for the per cent of full-load current on the first point, starting from rest, apply to rotor (secondary) current and to torque. The primary current will, in general, be a higher percentage of the full-load current. C. Starting- and intermittent-duty primary resistors which are designed for use with squirrel-cage motors and which meet the test described in 1C 1-13.42 (tem perature test) are included in the tables. D. Continuous-duty resistors shall be capable of carrying continuously the cur rent for which they are designed. E. An adjustable-speed motor having a given horsepower rating, when started with full field, generally requires a resistor having a larger ohmic value than does a constant-speed motor of the same horsepower rating. For this reason, the current on the first point and the capacity of the complete resistor of the same NEMA classification for an adjustable-speed motor may be different from that for a constant-speed motor of the same horsepower. Note--A continuous-duty resistor shall be so designed that the controller may be operated continuously on any point when the load follows its normal speedtorque curve, except that it must not be operated continuously below the mini mum speed specified. TABLE 1 --Class Numbers of Resistors for Non-Reversing Service and Reversing Non-Plugging Service Without Armature Shunt or Dynamic Braking Class Numbers Approximate ------------------------------------------------- Per Cent of Duty Cycles run-Luau cur rent on First 5 Sec. 10 Sec. 15 Sec. 15 Sec. 15 Sec. 15 Sec. Point Starting On On On On On On from Rest 75 Sec. 70 Sec. 75 Sec. 45 Sec. 30 Sec. 15 Sec. Off Off Off Off Off Off `Con tinu ous Duty 25 111 131 141 . 151 161 171 91 50 112 132 142 152 162 172 92 70 113 133 143 153 163 173 93 100 114 134 144 154 164 174 94 150 115 135 145 155 165 175 95 200 or over 116 136 146 156 166 176 96 For speed-regulating duty, see Table 4. When an armature shunt resistor is added, the class number shall include the suffix "AS". Example--Class 155-AS is a resistor which includes an armature shunt and which will allow an initial inrush of 150 per cent with the armature shunt open. When a dynamic braking resistor is added, the class number shall include the suffix "DB". Example--Class 155-DB. TABLE 2 --Class Numbers of Resistors for Reversing Plugging Service Without Armature Shunt or Dynamic Braking Approximate Per Cent of Full-Load Current on First Point Starting from Rest with All Resistance in Circuit Class Numbers Duty Cycles 15 Seconds On 45 Seconds Off 15 Seconds On 30 Seconds Off 15 Seconds On 15 Seconds Off Continuous Duty 25 151P 161P 171P 91P 50 152P 162P 172P 92P 70 153P 163P 173P 93P 100 154P 164P 174P 94P Note--The class numbers apply to the complete resistor, but the duty cycles apply to the accelerating resistor only. When an armature shunt resistor is added, the class number shall include the suffix "AS". Example--Class 153P-AS is a plugging resistor which includes an armature shunt and which will allow an initial inrush of 70 per cent with the armature shunt open. When a dynamic braking resistor is added, the class number shall include the suffix "DB". Example--Class 153P-DB. TABLE 3 --Class Numbers of Resistors for Dynamic Lowering Crane and Hoist Controllers Approximate Per Cent of Full-Load Cur- Class Numbers Duty Cycles Point Hoisting Starting from Rest without Armature Shunt 50 70 15 Seconds On 45 Seconds Off 152DL 153DL 15 Seconds On 30 Seconds Off 162DL 163DL 15 Seconds On 15 Seconds Off 172DL 173DL Continuous . Duty 92DL 93DL TABLE 4 --Class Numbers of Resistors for Continuous-Duty SpeedRegulating Services with Direct-Current Shunt Motors and Alternating- Current Wound Rotor Motors Per Cent Speed Class Numbers Per Cent of Rated Motor Torque at Reduced Speed 40 50 60 70 80 90 100 5 405 505 605 705 805 905 1005 10 410 510 610 710 810 910 1010 15 415 515 615 715 815 915 1015 20 420 520 620 720 820 920 1020 25 425 525 625 725 825 925 1025 30 430 530 630 730 830 930 1030 35 435 535 635 735 835 935 1035 40 440 540 640 740 840 940 1040 45 445 545 645 745 845 945 1045 50 450 550 650 750 850 950 1050 Note I--See 1C 1-2.04. NEMA standards for Industrial Control. Note II--The stability of the motor speed obtained by simple rheostatic control is dependent upon the stability of the load on the motor. The degree of Instability is directly proportional to the amount of speed reduction. Variations in load have a greater proportional effect on the speed when the load is light. For these reasons, Table 4 has not been carried beyond a speed reduction of 50 per cent and a load torque of 40 per cent. Note III--With a direct-current shunt motor, the per cent of rated motor current which is obtained at the reduced speed is assumed to be the same as the per cent of rated torque. With a wound-rotor motor and resistor in the motor circuit, the per cent of rated rotor (secondary) current which is obtained at the reduced speed is assumed to be the same as the per cent of rated torque. Note IV--A speed-regulating resistor is so designed that it may be operated continuously at any point in the speed-regulating range when the load follows its normal speed-torque curve. When additional resistance is required to obtain the starting current specified, the additional portion of the resistor shall be de signed for a duty cycle selected from Table 1. The resulting resistor may be completely specified by a compound number. For example, 154/850 designates a resistor which is designed for starting and speed-regulating duty. The starting section is designed to allow 100 per cent of full-load current on the first point, starting from rest, and a duty cycle of 15 sec onds on and 45 seconds off. The regulating section is designed to give 50 per cent speed reduction at 80 per cent of rated torque and for continuous duty when the load follows its normal speed-torque curve. Note V--If the speed-regulating resistor alone is used, the approximate per cent of rated current which will be obtained on the first point of the controller, start ing from rest, may be determined from the equation: Per cent torque at reduced speed Per Cent Current -------------------------------------------------- x 100 Per cent speed reduction CUTLER'HAMMER 276