Document 85LjY2LgJgXzYNqgEmrav1RMo
JQodlsctS- %emtca$-
ESCAMQIA PLANT INTEROFFICE MEMORANDUM
To: Mr. R. E. Davis
From:
A. K. McMillan
Re:
Dote:
Copies:
August Z, 1971
G. B. H. Speed R. W. Beech
In the past George Speed has represented Escambia at the Vinyl Chloride Safety Association meetings. When possible, Ron Beech or I have also attended these meetings. In the future Ron Beech will represent the Escambia plant. WiU you get with George Speed and do whatever is necessary to accomplish this.
fcKMjfls
A. *K. McMillan
AP00036038
<rc:
Tirestone Plastics Company
C^
DIVISION OF T H { FIRE ST ONE TIRE t- RUBIER COMPANY HARVEY * IIR.ESTOMC - FOUNDER
ttCNEAAL OFYieCR
r. o. aox
ROTTSTOWN. RCNN.YLVANIA 1.4*4
June 28, 1971
POTTSTOWN. PENNSYLVANIA
A^t
Hr. George B. H. Speed Sr. Froject Engineer Escambia Chemical Co, Box 467 Pensacola, Florida
Dear George:
Just talked with Glenn of General who says
meeting is set at Rochester, N. Y. Nov. 10-11-12,
1971. Luciaol will demonstrate for us - not sure
what but having to do with catalysis, VC and fire
or explosion.
Sincerely,
WWM/rc
W. w. Madden, Coordinator Special Projects
r
AP00036039
/
A
\ \
A&ng*u $e&s4ba& INC. ESCAMBIA PLANT
INTEROFFICE MEMORANDUM
To:
From:
Mr. T. L. Carey
A, K, McMillan
Dote:
Copies:
Mr. H. L. Watson's Memo to Mr. T. L. Carey July 12, 1971 on Vinyl Chloride Safety Association
August 2, 197 1 H. L. Watson
I am in agreement that someone from both the Calvert City and Escambia plants should attend the Vinyl Chloride Safety Association meetings. Both plants 1 believe can contribute to the purpose of the meetings and a representative from each location is needed to obtain a full understanding of the safety information available and to apply it to their plant location. Mr. Beech will represent the Escambia plant.
A. K. McMillan
AP00036040
i "f^crrix 7?-:xu3&
PUT IT IN WRITING
Date
July 12 f 19 71
ToT. L. CareySubject Vinvl Chloride Safety Association
From (
'(
H. L. Watson _______________________
) Take Action
{ ) For Your Approval
) For Your Comments ( ) As Requested
_.
( ) ForYourlnfo { ) File
{ ) Discuss With Me ( ) Note & Return
As you know and as we have discussed previously, we are maintain ing two memberships in the Vinyl Chloride Safety Association, one under Air Products (John Barr) and the other under Escambia.
The notice is out for the third meeting. I have discussed this with John and we both feel he should attend. We also feel that conditions permitting we should continue to have a representa tive from the Calvert location and the Pensacola location.
When the original Association was being set up, everyone felt
that the only limit should be on the total number of people
attending which was set at 50, and, therefore, no limit on
numbers from individual companies was set. They felt this
?
would suffice so long as companies did not start sending five
or six each. While we both feel it is advantageous both for
the purpose of the Association and .the good of Air Products to
have a representative from both our locations, we do feel obli
gated to advise the Committee of the fact that we are now one
Company and should not have two voting memberships. Any sugges
tions or advise to the Association I trust would emanate from
your office. X am merely listing here our feelings.
D
AP00036041
ESCAMBIA CHEMICAL CORPORATION
INTEROFFICE MEMORANDUM
To: Mr. R. W. Beech
From:
D. V. Lowe
Re: External Condensation of VCL Vapors from Reactor
Dote:
February 25, 1971
Copies:
Mr. J. D. Kramer Mr. W. J. Kerler Mr. A. K. McMillan Mr. G. B. H. Speed
A single tube one-pass heat exchanger was constructed from a 2" pipe of 304 S. S. and a 3M pipe of carbon steel for refrigerated cooling water. The vapor condenser thus constructed was placed in a reflux position over # 4 reactor. VCL vapors were ... allowed to rise through a 3" vessel nozzLe and isolation valve and up through a 3M - 304 S. S. riser to the inlet of the vapor condenser by natural convection. T^e* vapors were condensed* Liquid VCL
flowed from the lower end of the condenser and returned to the vessel over a liquid seal leg and through a 3" vessel nozzle. Dial thermometers were placed in the refrigerated cooling water inlet and outlet lines as well as a water flow meter in the inlet line.
The small condenser easiLy condensed all the vapors traveling up the 3" riser and the cooling water exiting the condenser jacket remained 64 F under the vapor condensation temperature. Heat removed under these condition amounted to 3, 486 BTU'fi per hour, or a temperature rise of 21 F for 166 lbs. per hour of cooling water. This equates to roughly 23 lbs. per hour of Liquid VCL condensed and returned to the reaction vessel by the vapor condenser. The calculated overall U was 12.15 BTXJ/hour - We had predicted an overalL U of 10 BTU/hour - ft^ - F from^mpirical equations.
"'It is apparent from this that a S. S. vapor condenser in the range of at least 300 square feet would be required over each reactor before plant capacity would be very significantly affected. However, the following disadvantages come to mind:
(a) Ail heat exchange equipment and repiping'would necessarily be 304 S. S. construction. Equipment aLso would be of speciaL design and fabrication. Costs .might be prohibitive.
AP00036042
Mr, R. W. Beech
2- -
February 25, 1971
"(b)
There are no nozzle# .on our existing reactors large enough to carry enough vapors whereby removal of heat of vaporization wo uld be of any significance.
(c) Our limited experience has shown that non condensables continuously buildup at the vapor condenser high point, regardless of how welL we pulled vacuum. This dramatically reduces the free flow of condensable YCL vapors and reduces heat removal. A continuous vent system and low-temperature vent condensing system; would be necessary to alleviate this problem, once again adding to the cost.
(d) Tube fouling via polymer buildup could be deleterious to heat removal after perhaps only 2 or 3 batches. Frequent chemical cleaning might be necessary, costing time and productive yield.
(e) If any of the condenser tubes ever plugged solid, it would be very difficult to get them re-opened since chemical cleaning is effective only when the buildup is exposed to free-flowing hot solvent.
(f) Even if the above disadvantages were not so serious, the fact that we might charge greater batches of VCL. does not mean that we have any more available
agitator power to drive bigger batches. We could only hope to charge more catalyst to batches of present sizes. This means shorter reaction cyde times, but in most cases we would be limited by drying and/or stripping times.
/ ms
D. V. Liowe
AP00036043
ESCAMBIA CHEMICAL CORPORATION
INTEROFFICE MEMORANDUM
To: Mr. T. L, Carey
From: G. B. H. Speed Re: Membership in Vinyl Chloride
Safety Association
Date: November 23, 1970
Copies: J. D* Kramer , A *--K. McMillan E. M. Spurlock
The By-laws of the Vinyl Chloride Safety Association require a request by an officer of the company for membership. In ihe request the company agrees to abide by the By-laws and names a permanent representative. A draft of a request is attached.
Mr. J. F. Healy sees no objections from a legal standpoint to Escambia becoming a member. My correspondence with Mr. Healy is also attached for your information. Please return the correspondence*
GBHS/as Attach.
G. B. H. Speed
AP00036044
E5CRMBIR
CHEMIEZRL- CDRPQRRT1DN
. A 11/11
Of
7Hm&31 m/ ChtTitm/*
P.O. Box 467. Pnaacol, Florida 32502
November 23, 1970
Mr. W. W. Madden, Secretary Vinyl Chloride Safety Association c/o Firestone Plastics Company P. O. Box 699 Fottstown, Pa. 19464
Dear Mr. Madden:
Escambia Chemical, a wholly owned subsidiary of Air Px'oducts and Chemicals, Inc. wishes to become a member of the Vinyl Chloride Safety Association and agrees to abide by the By laws of the Association.
- The permanent representative will be:
Name:
Title:
Escambia Chemical Corporation
P. O. Box 467
Pensacola, Florida 32502
Very truly yours,
T. E. Carey President
AP00036045