Document 85LgNd6EwGDY3Ln3J5a3Kyr8e
rzD * 21 REV. 4/43
PROGRESS REPORT
drdanjc Chemicals division
RESEARCH OEST. RT. LOUIS, MO.
RESORTED RV
*W. E. Koerner *V. W. Saeger *C. E. Vogler
*L. Fowler #W. N. Trump
-
re*
DETAILS
October DECEMBER. '62
YES
JOB NOB.
2-02-760.01-4282
EPOBT NO.
4
PROJECT
UNCL-12
lirformctlM herein li CONFIDENTIAL and It Hi* property ol MONSANTO CHEMICAL COMPANY, Only thot* portloni relevent to duly authorised person's need to know may be excerpted tor Mm. This document mutt not be sent outside the Company without written approval end tb* authorised recipient is accountebl* tor Its safekeeping, oscerpHnf or otherwise disclosing Its contents end for Its proper disposal. The document remains the property of MONSANTO CHEMICAL COM PANY and unleu otherwise specifically authorised shall be returned within two months to H* source.
DISTRIBUTION
with oetails
STANDARDI
*H. L. Hubbard - Res-1
J. E. Franz - Res-3 R. H. Mills - Res-3
J . F. Quinn - Res-1
J. H. Van Ness - Res-3
M. A. Terpstra - Res-1 *E. T. Reavllle - Res. Cntr.
*K. L. McHugh - Res-2
J. R. Durland - B-2-S
_____ R. Darby - Res-3______ H. A. Hashbarser - B-2-S
PROJECT TITLE
*R. S. Wobus - B-2-S *D. B. Hosmer - B-2-N *MCL(2)-J.F.Stlckley*MCAL(2) B-3-N *R. W. Wise - Nltro
PHYSICAL CHEMICAL STUDIES
PROJECT OBJECTIVE
To provide physical properties data, thermal stability Information, and fundamental physical chemical studies needed for the support of Research Department projects.
SUMMARY
1. Thermal Conductivity of Fusible Organic Solids
Minor modifications involving improvements in the methods of thermocouple and line source attachment in the non-steady state line source thermal conductivity apparatus have been completed. Measurements are now under way on a series of organic solids. Various factors such as variation between thermocouples, reproducibility of a single thermocouple, variation with power input, and effect of occluded air in the solid will be investigated more completely during this series.
2. Rapid Hlgh-Sensltlvlty Differential Thermal Analysis (DTA)
A series of sealed cell experiments at a rapid heating rate (8C. per minute) Involving comparison of stable materials of different specific heats and thermal conductivities has demonstrated the importance of a close matching of thermal
properties of sample and reference in high speed analysis.
Comparative experiments on Aroclor samples also indicated that convection is an extremely important mode of heat
transfer for liquid samples where large cells are used to achieve high sensitivity, thus necessitating a close matching
not only of thermal properties but of viscosity in high
speed analysis. These results indicate the necessity for compromise between sensitivity and heating rate. Further
work to define this area will be carried out.
0547807
HARTOLDMON0005042
2-02-760.01-4282(4) Page 2
'$. Thermlnol Fluid Vapor Pressure and Thermal Stability Instrument Equipment modifications were made to provide more accurate recording of sample vapor pressure and temperature. Calibration drifts in the instrument which resulted from voltage changes in the mercury batteries in the logarithmic compressor units wereeliminated by replacing the original mercury batteries with ones having superior voltage stability. Reproducible plots of pressure vs. temperature for the Thermlnol fluids and dodecane which agree well with published vapor pressure data have been obtained. Sample decomposition is discernible from the vapor pressure plots at heating rates of 5C./min. Slower heating rates magnify the effect. The presence of low boilers in the Thermlnols is also discernible from the vapor pressure plots but their identification, if necessary, would require some other means of analysis. Work is under way to develop stability data with this instrument upon which specifications for the Thermlnols can be based.
V. W. Saeger W. N. Trump C. E. Vogler
dm
054 7808
HARTOLDMON0005043
2-02-760.01-4282(4) Page 3
DETAILS
5. Thermlnol Fluid Vapor Pressure and Thermal Stability Instrument
In the course of testing the vapor pressure apparatus, several deficiencies of design were noted and were corrected. These concerned (1) the sample cell and furnace, and (2) certain components of the electronic recording and control assembly. The changes made to provide more accurate recording of the pressure-temperature curve of the sample are described below.
(1) Cell and Furnace Modifications
Tests of the original cell with thermocouples connected to an external recorder had shown that there were excessive temperature gradients both radially and vertically through the cell. Presence of a radial temperature gradient during the heating cycle was ascribed to the relatively great thickness of the cell walls and of the layer of sample within the cell; existence of a vertical temperature gradient was assumed to be caused by stratification of the air within the furnace. A new cell was made of annular cylindrical construction so that the liquid layer would be thin and with the least wall thickness consistent with a pressure test of 2500 psi at room temperature. In addition, a small motor-driven fan blade was placed in the bottom of the furnace compartment to provide continuous circulation of air in the furnace and hence convective rather than radiative heating. With these changes, temperature differences between different parts of the cell were reduced to about 2 at constant temperature, 5 at a heating rate of 5/min., and 8 at a rate of 20/min. Further improvements in minimizing temperature gradients and also in reducing the amplitude of the cycling of furnace temperature were made by placing an aluminum shield between the furnace and the cell. This was made at the suggestion of Dr. R. H. Munch to prevent radiative heating of the sensing thermocouple during the "on" portions of the furnace control cycle.
(2) Electronics Modifications
The temperature and pressure recording systems of the Instrument were tested Independently of each other and of sample by using a motor-driven variac to program heat to the sensing thermocouple and by bleeding nitrogen into the system through a needle valve to simulate vapor pressure increase with temperature. 0547809 During these tests the outputs of the amplifiers were recorded separately. The deviations of the recorded vapor pressure curves from a smooth curve with respect to both temperature and pressure were cyclic with a period of about 2 minutes. These
HARTOLDMON0005044
2-02-760.01-4282(4) Page 4
variations were found to originate in the logarithmic compressor units and to be synchronous with changes of temperature in these units. The logarithmic compressors had been placed in a thermally-insulated box provided with electrical heating under thermo static control. The thermostat used apparently did not respond rapidly enough to give close control of the box temperature. As a temporary measure, a small heater was attached to the thermostat shell to produce anticipation of temperature changes. This change reduced the cycling of the logarithmic compressor output to an acceptable level. A type of thermostat better suited to this application was later obtained and may be installed as a permanent modification when the opportunity occurs.
Occasional slow changes of both pressure and temperature calibration also were observed, in addition to the cycling just mentioned. These slow changes also were traced to the logarithmic compressor units; specifically, to the batteries supplying current to the transistor amplifiers of these units. Changes of voltage here produced an apparent shift of zero of the temperature and pressure scales. Type TM-233 mercury batteries had been installed originally. Although each of these batteries is composed of RM-3 cells, the voltage stability of the assembled batteries seems to be inferior to that of individual RM-3R cells. There fore, the TM-233 batteries were replaced by the equivalent stacks of RM-3R cells, with resulting elimination of the calibration drifts previously noted.
Some minor alterations were made in the temperature programming circuit in an attempt to reduce the amplitude of the cycling of furnace temperature. A small improvement was obtained with furnace temper ature cycles of about 5 amplitude. This much variation of furnace temperature produced a detectable variation of vapor pressure. Further improvement of the temperature control probably would be desirable.
With the new design cell described above, vapor pressure-temper ature plots in excellent agreement with known vapor pressures for dodecane were obtained. Thermlnol fluid samples which were thoroughly degassed and had the more volatile components removed gave a vapor pressure plot in good agreement with the lsotenlscope measurements by Dr. K. L. McHugh's group. However, these runs were made before the major portion of electronic modifications were made and some doubt is cast upon their validity because of difficulties with instrument stability which followed. These difficulties appear to have been resolved and confidence in the reproducibility of the instrument has now been achieved. Recent runs with Thermlnol FR-2 check well with
0S47S10
HARTOLDMON0005045
2-02-760.01-4282(4) Page 5
earlier runs made before the Interim that difficulties Kith Instrument stability were experienced. Attached to this report are the vapor pressure curves from several of the recent runs Kith Thermlnol FR-2. The traces betKeen vapor pressures of about 5 up to 50 psla shoK nearly the straight line relationship Khich Kould be expected of a single component sample or a mixture of compounds Kith very Bimllar boiling points and heats of vaporization. The lOKer portion of the curves appear to give some measure of the Iok boilers In the sample. In Run No. 44 some of the Iok boilers were removed during degassing and the resultant vapor pressures Kere dlscernlbly lOKer than for Run No. 45 in Khich care Kas taken to retain the Iok boilers In the sample. The reliability of the curve beIok 3 psla Is questionable because of high sensitivity In this region to upsets In the system and It Is yet to be determined Khether this portion of the curve Kill be useful in screening batches of Aroclor for designation as Thermlnols. If it becomes Important to Identify Iok boilers to determine if flammable components are present, analysis such as gas chromatography should also be utilized In screening the Thermlnol fluids.
The deviation of the upper part of the vapor pressure plots from an extension of the straight line portion is a measure of the decomposition and Is readily discernible at a heating rate of 5C./mln. (plots No. 44 and 45). The deviation Is greatly magnified at the sloKer heating rate of lC./mln. as shOKn In plot No. 46. Optimum heating rates for control use of the instrument at Anniston appear to fall In this range (l-5C./mln.).
Experiments Kith Thermlnols contaminated Kith Iok boiler, e.g., benzene and decomposable Impurities, e.g., alkyl chlorides are being made to help decide stability specifications for the Thermlnols based on this Instrument.
V. W. Saeger
W. N. Trump
C. E. Vogler
dm Atts. (3)
0547811
HARTOLDMON0005046
0--
--
m
- -*
--
PRESSUAE " ASIA
1T -4-
(
/l
* *
%
*
/ /
/ r
/
/ i /
/
/
L - i -i.
T
.-i -J-
7
L. "
*
.
f~ if
t j r
L j/
f 7 ,/
/ j /
Ob'. 7812
-I-1-J..I.-I 1 U 1
ivy 'r^p wv,
4WW
.
uu duu
' u^t^mc - *c
- />'/F/?-2- CAiB-^t)
fA^..;-..
. .*;
'
. . ; ' Hutu* M-se/>r^
......
. ',. . ' .
' ...... '
..: .* ' ,.' > ix-xi-ii-
HARTOLDMON0005047
PSIA-
PRESSURE
300 50 . 20
z
HARTOLDMON0005048
HARTOLDMON0005049