Document 855yvOEQyM42Rnm11Rr8Gm6gZ
capillary column chromatographic CONDITIONS;
Instrument: Perkin-Elmer Model 800
Type Detector: Flame Ionization
Column: 0.02" x 100' SE-52 Silicone Gum Rubber Support Coated Open Tubular (S.C.O.T.)
Column Temperature: 200 to 260C @ 2/Min.
Detector Block Temperature: 260C
Injection Port Temperature: 340C
Sample Volume Injected: 0.010 ml. Split 1 to 30
Solvent:. CS2
.
Sample Concentration: 20%
Flow Rates Nitrogen: 10 ml./min. Auxiliary Gas: 10 ml./min. Hydrogen: 30 ml./min. Air: 400 ml./min.
DSW 152813
STLCOPCB4040159
DSW 152814
STLCOPCB4040160
DSW 152815
<*g>>
STLCOPCB4040161
DSW 152816
01
ra.62
STLCOPCB4040162
GENERAL ANALYTICAL OUTLINE
CONCENTRATION
Kundrna-Danish Evap. Cone. Rotatory Evap. Cone.
Sample(s)
- Air - Water - Soil - Sediment - Fish, Fowl,
& Animals Tissues & Excrement - Misc.
Soxhelt Wahring Blender Virtis
Homogenizer Direct Solv.
Extraction
-Polar/Non Polar Solvent Partition
-Column Chromatography Alumina Silica
-Chemical Oxodation --
h2so4/hno3
cr2o;7/hoac
TLC GC
Saponification
Ale - KOH Glycol - KOH
^
CO CM
in
5
CO Q
- Two Column GC-EC -DMC -FID
- GC/Mass
- Reaction/GC
IR
S.C.O.T. Col. fingerprint (product ident.)
EC DMC FID IR
STLCOPCB4040163
SUPPLEMENT TO GENERAL ANALYTICAL OUTLINE
WATER
(Measure)
Extract and Hexane
Concentrate
Check with EC/GC
Concentrate
TLC or Chemical Separation
Check with EC/GC
S.C.O.T. Col/FID fingerprint
GC/Mass
.
SEDIMENT
Dry Grind Measure
Extract with acetonitrile
Concentrate
-
Check with EC/GC
Concentrate
TLC or Chemical Separation
Check with EC/GC
S.C.O.T. Col/FID fingerprint
GC/Mass
TISSUES
S
4
Measure
Extract and/or Homogenize with Hexane
Polar/Non-polar Solvent Part.
Concentrate
Alumina Column
Concentrate
Check with EC/GC
TLC or Chemical Separation
Check with EC/GC
S.C.O.T. Col/FID fingerprint
GC/Mass
.
4-18-69
DSW 152818
STLCOPCB4040164
DSW 152819
GENERAL ANALYTICAL OUTLINE
CONCENTRATION
Kundrna-Danish Evap. Cone. Rotatory Evap. Cone.
Sample(s)
- Air - Water - Soil - Sediment - Fish, Fowl,
& Animals Tissues & Excrement - Misc.
Soxhelt Wahring Blender
Virtis Homogenizer
Direct Solv. Extraction
-Polar/Non Polar Solvent Partition
-Column Chromatography Alumina Silica
-Chemical Oxodation -.........
h2so4/hno3
cr207/hoac
TLC GC
)
Saponification --------^
Ale - KOH Glycol - KOH
- Two Column GC-EC -DMC -FID
- GC/Mass
- Reaction/GC
IR
S.C.O.T. Col. fingerprint (product ident.)
EC DMC FID IR
)
STLCOPCB4040165
SUPPLEMENT TO GENERAL ANALYTICAL OUTLINE
WATER
(Measure) Extract and Hexane Concentrate Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass
SEDIMENT
Dry Grind Measure Extract with acetonitrile Concentrate Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass
TISSUES
4
Measure Extract and/or Homogenize with Hexane Polar/Non-polar Solvent Part. Concentrate Alumina Column Concentrate Check with EC/GC TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass
4-1B-69
DSW 152820
STLCOPCB4040166
RELATIVE RETENTION TIMES OF AROCLORS AND SOME PESTICIDES ON QF-1 FLUOROSILICONE COLUMN (p,p` DDE = 8.1 Min. = 100)
Instruments F&M Model 402 High Efficiency Gas Chromatograph
Type of Detectors
Electron Capture - high temperature Ni*>3 cell (pulsed voltage type) glass U shaped
Columns 6 MM (OD) X 6 M 6% QF-1 on 80/100 Mesh Chromosorb W Column Temperatures 190C Detector Temperatures 250C Injection Port Temperatures 225C Sample Volume: 1-5 jal
Flow Rates
Helium (carrier gas) 60 ml/min. Argon Methane (purge gas) 185 ml/min.
Aroclor 1242: 9, 13, 18, 20, 24, 28, 33, 38, 42, 45 , 54, 65, 71, 82, 95, 103, 123, 153.
Aroclor 1248: 24, 29, 33, 39, 43, 46, 55, 66, 72, 80, 83, 96, 104, 125, 154, 164, 206, 252, 314.
Aroclor 1254: 23, 28, 45, 54, 71, 77, 94, 103, 125, 132, 145, 154, 164, 206, 250, 314.
Aroclor 1260: 24, 29, 38, 46, 66, 77, 90, 109, 133, 145, 165, 202, 252, 311, 381, 476.
Aroclor 1262: 66, 78, 90, 100, 110, 133, 145, 166, 202, 253, 310, 381, 478, 531.
Aroclor 126 8: 73, 131, 165, 180, 228, 251, 300, 317 , 342, 474, 541.
1) Lindane - 41 2) Hep'tachler - 45 3) Aldrin - 51 4) pp' DDE - 100 5) pp' DDD - 120
4- 18-69
6) Op' DDT - 127 7) Dieldrin - 142 8,9) Endrin, pp' DDD - 170 10) Methoxychlor - 292
DSW 152821
STLCOPCB4040167
AROCLORS g X 10
1242 1248 1254 1260 1262 1268
5.18 5.11 5.11 5.35 5.03 5.00
PESTICIDES g X 10
e Endrin :2- Heptachlor / Lindane 7 o Methoxychlor
C o,p DDT f pp' DDE 5 9 pp' DDD 3 Aldrin
7 Dieldrin
5.13 5.22 5.50 5.17 5.46 5.18 5.63 5.08 5.04
4-18-69
DSW 152822
STLCOPCB4040168
STLCOPCB4040169
GENERAL ANALYTICAL OUTLINE
CONCENTRATION
Kundrna-Danish Evap. Cone. Rotatory Evap. Cone.
Sample(s) - Air - Water - Soil - Sediment - Fish, Fowl,
& Animals Tissues & Excrement - Misc.
04 00 CM
in
5(0 o
Soxhelt Wahring Blender Virtis
Homogenizer Direct Solv.
Extraction
-Polar/Non Polar Solvent Partition
-Column Chromatography Alumina Silica
TLC GC
Chemical Oxodation ----.......
h2so4/hno3
)
cr2o7/hoac
Saponification --------^
Ale - KOH Glycol - KOH
- Two Column GC-EC --DMC -FID
- GC/MaSS
- Reaction/GC ........
- IR
- S.C.O.T. Col. fingerprint (product ident.)
EC DMC FID IR
)
STLCOPCB4040170
SUPPLEMENT TO GENERAL ANALYTICAL OUTLINE
WATER
(Measure) Extract and Hexane Concentrate Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass
SEDIMENT
Dry Grind Measure
Extract with acetonitrile
Concentrate
.
Check with EC/GC
Concentrate
TLC or Chemical Separation
Check with EC/GC
..
S.C.O.T. Col/FID fingerprint
GC/Mass
TISSUES
\
4
Measure
Extract and/or Homogenize with Hexane
Polar/Non-polar Solvent Part.
Concentrate
Alumina Column
Concentrate
Check with EC/GC
TLC or Chemical Separation
Check with EC/GC
S.C.O.T. Col/FID fingerprint
GC/Mass
.
4-1B-69
ds\n ^52825
STLCOPCB4040171
RELATIVE RETENTION TIMES OF AROCLORS AND SOME PESTICIDES ON QF-1 FLUOROSILICONE COLUMN (p,p* DDE = 8.1 Min. = 100)
Instrument; F&M Model 402 High Efficiency Gas Chromatograph
Type of Detector;
Electron Capture - high temperature Ni^3 cell (pulsed voltage type)
glass U shaped
Column: 6 MM (OD) X 6 M 6% QF-1 on 80/100 Mesh Chromosorb W
Column Temperature: 190C
Detector Temperature: 250*0
..
Injection Port Temperature: 225C
Sample Volume: 1-5 pi
Flow Rates
Helium (carrier gas) 60 ml/min.
.
Argon Methane (purge gas) 185 ml/min.
Aroclor 1242: 9, 13, 18, 20, 24, 28, 33, 38, 42, 45, 54, 65, 71, 82 95, 103, 123, 153.
Aroclor 1248: 24, 29, 33, 39, 43, 46, 55, 66, 72, 80, 83, 96, 104, 125, 154, 164, 206, 252, 314.
Aroclor 1254: 23, 28, 45, 54, 71, 77, 94, 103, 125, 132, 145, 154, 164, 206, 250, 314.
Aroclor 1260: 24, 29, 38, 46, 66, 77, 90, 109, 133, 145, 165, 202, 252, 311, 381, 476.
Aroclor 1262: 66, 78, 90, 100, 110, 133, 145, 166, 202, 253, 310, 381, 478, 531.
Aroclor 1268: 73, 131, 165, 180, 228, 251 , 300, 317, 342, 474, 541.
1) Lindane - 41 2) Heptachler - 45 3) Aldrin - 51 4) pp' DDE - 100 5) pp' DDD - 120
4-18-69
6) op* DDT - 127. 7) Dieldrin - 142 8,9) Endrin, pp' DDD - 170 10) Methoxychlor - 292
DSW 152826
STLCOPCB4040172
AROCLORS g X 10~8
1242 124$ 1254 1260 1262 1268
5.18 5.11 5.11 5.35 5.03 5.00
PESTICIDES g X 10
<3 Endrin Heptachlor
/ Lindane 7.0 Methoxychlor
C o,p DDT pp.' DDE
S49 pp' DDD 3 Aldrin (7 Dieldrin
5.13 5.22 5.50 5.17 5.46 5.18 5.63 5.08 5.04
18-69
DSW 152827
STLCOPCB4040173
DSW 152828
STLCOPCB4040174
DSW 152829
GENERAL ANALYTICAL OUTLINE
CONCENTRATION
Kundrna-Danish Evap. Cone. Rotatory Evap. Cone.
Sample(s)
- Air - Water - Soil - Sediment - Fish, Fowl,
a Animals Tissues a
Excrement - Misc.
Soxhelt Wahring Blender Virtis
Homogenizer
Direct Solv. Extraction
-Polar/Non Polar Solvent Partition
-Column Chromatography Alumina Silica
-Chemical Oxodation - .....
h2so4/hno3 .
cr2o?/hoac
TLC GC
)
Saponification --------^
Ale - KOH Glycol - KOH
- Two Column GC-EC --DMC -FID
- GC/Mass
- Reaction/GC -
- IR
-- S.C.O.T. Co1. fingerprint (product ident.)
EC DMC FID IR
)
STLCOPCB4040175
SUPPLEMENT TO GENERAL ANALYTICAL OUTLINE
WATER
(Measure)
Extract and Hexane
Concentrate
.
Check with EC/GC
Concentrate
TLC or Chemical Separation
Check with EC/GC
S.C.O.T. Col/FID fingerprint
GC/Mass
.
SEDIMENT
Dry Grind Measure
Extract with acetonitrile
Concentrate
Check with EC/GC
Concentrate .
TLC or Chemical Separation
Check with EC/GC
.-
S.C.O.T. Col/FID fingerprint
GC/Mass
TISSUES
N
*
Measure
Extract and/or Homogenize with Hexane
Polar/Non-polar Solvent Part.
Concentrate
Alumina Column
Concentrate
Check with EC/GC
TLC or Chemical Separation
Check with EC/GC
'
S.C.O.T. Col/FID fingerprint
GC/Mass
4-18-69
DsW 152830
STLCOPCB4040176
RELATIVE RETENTION TIMES OF AROCLORS AND SOME PESTICIDES ON QF-I FLUOROSILICONE COLUMN (p,p DDE = 8.1 Min. =100)
Instrument: F&M Model 402 High Efficiency Gas Chromatograph
Type of Detector:
Electron Capture - high temperature
Ni3 cell (pulsed voltage type)
glass U shaped
..
Column: 6 MM (OD) X 6 M 6% QF-1 on 80/100 Mesh Chromosorb W
Column Temperature: 190C
.
Detector Temperature: 250C
.
Injection Port Temperature: 225C
Sample Volume: 1-5 pi
..
Flow Rates
Helium (carrier gas) 60 ml/min. Argon Methane (purge gas) 185 ml/min.
'
Aroclor 1242: 9, 13, 18/ 20, 24, 28, 33, 38, 42, 45 , 54, 65, 71, 82, 95, 103, 123 , 153 .
Aroclor 1248: 24, 29, 33, 39, 43, 46, 55, 66, 72, 80, 83, 96, 104, 125, 154, 164, 206, 252 ,314.
Aroclor 1254: 23, 28, 45, 54, 71, 77, 94, 103, 125, 132, 145, 154, 164, 206, 250, 314.
Aroclor 1260: 24, 29, 38, 46, 66, 77, 90, 109, 133, 145, 165, 202, 252, 311, 381, 476.
Aroclor 1262: 66, 78, 90, 100, 110, 133, 145, 166, 202, 253, 310, 381, 478, 531.
Aroclor 1268: 73, 131, 165, 180, 228, 251 , 300, 317 , 342, 474, 541.
1) Lindane - 41 2) Heptachler - 45 3) Aldrin - 51 4) pp * DDE - 100 5) pp' DDD - 120
4- 18-69
6) op' DDT - 127. 7) Dieldrin - 142 8,9) Endrin, pp* DDD - 170 10) Methoxychlor - 292
0Siv
-1
STLCOPCB4040177
AROCLORS g X 10
1242 1248 1254 1260 1262 1268
5.18 5.11 5.11 5.35 5.03 5.00
PESTICIDES g X 10
<3 Endrin Keptachlor
/ Lindane 7.0 Methoxychlor
orp DDT pp * DDE pp' DDD
3 Aldrin
7 Dieldrin
5.13 5.22 5.50 5.17 5.46 5.18 5.63 5.08 5.04.
4-18-69
SW 152832
STLCOPCB4040178
CO CO CO
CinM </> D
STLCOPCB4040179