Document 855yvOEQyM42Rnm11Rr8Gm6gZ

capillary column chromatographic CONDITIONS; Instrument: Perkin-Elmer Model 800 Type Detector: Flame Ionization Column: 0.02" x 100' SE-52 Silicone Gum Rubber Support Coated Open Tubular (S.C.O.T.) Column Temperature: 200 to 260C @ 2/Min. Detector Block Temperature: 260C Injection Port Temperature: 340C Sample Volume Injected: 0.010 ml. Split 1 to 30 Solvent:. CS2 . Sample Concentration: 20% Flow Rates Nitrogen: 10 ml./min. Auxiliary Gas: 10 ml./min. Hydrogen: 30 ml./min. Air: 400 ml./min. DSW 152813 STLCOPCB4040159 DSW 152814 STLCOPCB4040160 DSW 152815 <*g>> STLCOPCB4040161 DSW 152816 01 ra.62 STLCOPCB4040162 GENERAL ANALYTICAL OUTLINE CONCENTRATION Kundrna-Danish Evap. Cone. Rotatory Evap. Cone. Sample(s) - Air - Water - Soil - Sediment - Fish, Fowl, & Animals Tissues & Excrement - Misc. Soxhelt Wahring Blender Virtis Homogenizer Direct Solv. Extraction -Polar/Non Polar Solvent Partition -Column Chromatography Alumina Silica -Chemical Oxodation -- h2so4/hno3 cr2o;7/hoac TLC GC Saponification Ale - KOH Glycol - KOH ^ CO CM in 5 CO Q - Two Column GC-EC -DMC -FID - GC/Mass - Reaction/GC IR S.C.O.T. Col. fingerprint (product ident.) EC DMC FID IR STLCOPCB4040163 SUPPLEMENT TO GENERAL ANALYTICAL OUTLINE WATER (Measure) Extract and Hexane Concentrate Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass . SEDIMENT Dry Grind Measure Extract with acetonitrile Concentrate - Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass TISSUES S 4 Measure Extract and/or Homogenize with Hexane Polar/Non-polar Solvent Part. Concentrate Alumina Column Concentrate Check with EC/GC TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass . 4-18-69 DSW 152818 STLCOPCB4040164 DSW 152819 GENERAL ANALYTICAL OUTLINE CONCENTRATION Kundrna-Danish Evap. Cone. Rotatory Evap. Cone. Sample(s) - Air - Water - Soil - Sediment - Fish, Fowl, & Animals Tissues & Excrement - Misc. Soxhelt Wahring Blender Virtis Homogenizer Direct Solv. Extraction -Polar/Non Polar Solvent Partition -Column Chromatography Alumina Silica -Chemical Oxodation -......... h2so4/hno3 cr207/hoac TLC GC ) Saponification --------^ Ale - KOH Glycol - KOH - Two Column GC-EC -DMC -FID - GC/Mass - Reaction/GC IR S.C.O.T. Col. fingerprint (product ident.) EC DMC FID IR ) STLCOPCB4040165 SUPPLEMENT TO GENERAL ANALYTICAL OUTLINE WATER (Measure) Extract and Hexane Concentrate Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass SEDIMENT Dry Grind Measure Extract with acetonitrile Concentrate Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass TISSUES 4 Measure Extract and/or Homogenize with Hexane Polar/Non-polar Solvent Part. Concentrate Alumina Column Concentrate Check with EC/GC TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass 4-1B-69 DSW 152820 STLCOPCB4040166 RELATIVE RETENTION TIMES OF AROCLORS AND SOME PESTICIDES ON QF-1 FLUOROSILICONE COLUMN (p,p` DDE = 8.1 Min. = 100) Instruments F&M Model 402 High Efficiency Gas Chromatograph Type of Detectors Electron Capture - high temperature Ni*>3 cell (pulsed voltage type) glass U shaped Columns 6 MM (OD) X 6 M 6% QF-1 on 80/100 Mesh Chromosorb W Column Temperatures 190C Detector Temperatures 250C Injection Port Temperatures 225C Sample Volume: 1-5 jal Flow Rates Helium (carrier gas) 60 ml/min. Argon Methane (purge gas) 185 ml/min. Aroclor 1242: 9, 13, 18, 20, 24, 28, 33, 38, 42, 45 , 54, 65, 71, 82, 95, 103, 123, 153. Aroclor 1248: 24, 29, 33, 39, 43, 46, 55, 66, 72, 80, 83, 96, 104, 125, 154, 164, 206, 252, 314. Aroclor 1254: 23, 28, 45, 54, 71, 77, 94, 103, 125, 132, 145, 154, 164, 206, 250, 314. Aroclor 1260: 24, 29, 38, 46, 66, 77, 90, 109, 133, 145, 165, 202, 252, 311, 381, 476. Aroclor 1262: 66, 78, 90, 100, 110, 133, 145, 166, 202, 253, 310, 381, 478, 531. Aroclor 126 8: 73, 131, 165, 180, 228, 251, 300, 317 , 342, 474, 541. 1) Lindane - 41 2) Hep'tachler - 45 3) Aldrin - 51 4) pp' DDE - 100 5) pp' DDD - 120 4- 18-69 6) Op' DDT - 127 7) Dieldrin - 142 8,9) Endrin, pp' DDD - 170 10) Methoxychlor - 292 DSW 152821 STLCOPCB4040167 AROCLORS g X 10 1242 1248 1254 1260 1262 1268 5.18 5.11 5.11 5.35 5.03 5.00 PESTICIDES g X 10 e Endrin :2- Heptachlor / Lindane 7 o Methoxychlor C o,p DDT f pp' DDE 5 9 pp' DDD 3 Aldrin 7 Dieldrin 5.13 5.22 5.50 5.17 5.46 5.18 5.63 5.08 5.04 4-18-69 DSW 152822 STLCOPCB4040168 STLCOPCB4040169 GENERAL ANALYTICAL OUTLINE CONCENTRATION Kundrna-Danish Evap. Cone. Rotatory Evap. Cone. Sample(s) - Air - Water - Soil - Sediment - Fish, Fowl, & Animals Tissues & Excrement - Misc. 04 00 CM in 5(0 o Soxhelt Wahring Blender Virtis Homogenizer Direct Solv. Extraction -Polar/Non Polar Solvent Partition -Column Chromatography Alumina Silica TLC GC Chemical Oxodation ----....... h2so4/hno3 ) cr2o7/hoac Saponification --------^ Ale - KOH Glycol - KOH - Two Column GC-EC --DMC -FID - GC/MaSS - Reaction/GC ........ - IR - S.C.O.T. Col. fingerprint (product ident.) EC DMC FID IR ) STLCOPCB4040170 SUPPLEMENT TO GENERAL ANALYTICAL OUTLINE WATER (Measure) Extract and Hexane Concentrate Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass SEDIMENT Dry Grind Measure Extract with acetonitrile Concentrate . Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC .. S.C.O.T. Col/FID fingerprint GC/Mass TISSUES \ 4 Measure Extract and/or Homogenize with Hexane Polar/Non-polar Solvent Part. Concentrate Alumina Column Concentrate Check with EC/GC TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass . 4-1B-69 ds\n ^52825 STLCOPCB4040171 RELATIVE RETENTION TIMES OF AROCLORS AND SOME PESTICIDES ON QF-1 FLUOROSILICONE COLUMN (p,p* DDE = 8.1 Min. = 100) Instrument; F&M Model 402 High Efficiency Gas Chromatograph Type of Detector; Electron Capture - high temperature Ni^3 cell (pulsed voltage type) glass U shaped Column: 6 MM (OD) X 6 M 6% QF-1 on 80/100 Mesh Chromosorb W Column Temperature: 190C Detector Temperature: 250*0 .. Injection Port Temperature: 225C Sample Volume: 1-5 pi Flow Rates Helium (carrier gas) 60 ml/min. . Argon Methane (purge gas) 185 ml/min. Aroclor 1242: 9, 13, 18, 20, 24, 28, 33, 38, 42, 45, 54, 65, 71, 82 95, 103, 123, 153. Aroclor 1248: 24, 29, 33, 39, 43, 46, 55, 66, 72, 80, 83, 96, 104, 125, 154, 164, 206, 252, 314. Aroclor 1254: 23, 28, 45, 54, 71, 77, 94, 103, 125, 132, 145, 154, 164, 206, 250, 314. Aroclor 1260: 24, 29, 38, 46, 66, 77, 90, 109, 133, 145, 165, 202, 252, 311, 381, 476. Aroclor 1262: 66, 78, 90, 100, 110, 133, 145, 166, 202, 253, 310, 381, 478, 531. Aroclor 1268: 73, 131, 165, 180, 228, 251 , 300, 317, 342, 474, 541. 1) Lindane - 41 2) Heptachler - 45 3) Aldrin - 51 4) pp' DDE - 100 5) pp' DDD - 120 4-18-69 6) op* DDT - 127. 7) Dieldrin - 142 8,9) Endrin, pp' DDD - 170 10) Methoxychlor - 292 DSW 152826 STLCOPCB4040172 AROCLORS g X 10~8 1242 124$ 1254 1260 1262 1268 5.18 5.11 5.11 5.35 5.03 5.00 PESTICIDES g X 10 <3 Endrin Heptachlor / Lindane 7.0 Methoxychlor C o,p DDT pp.' DDE S49 pp' DDD 3 Aldrin (7 Dieldrin 5.13 5.22 5.50 5.17 5.46 5.18 5.63 5.08 5.04 18-69 DSW 152827 STLCOPCB4040173 DSW 152828 STLCOPCB4040174 DSW 152829 GENERAL ANALYTICAL OUTLINE CONCENTRATION Kundrna-Danish Evap. Cone. Rotatory Evap. Cone. Sample(s) - Air - Water - Soil - Sediment - Fish, Fowl, a Animals Tissues a Excrement - Misc. Soxhelt Wahring Blender Virtis Homogenizer Direct Solv. Extraction -Polar/Non Polar Solvent Partition -Column Chromatography Alumina Silica -Chemical Oxodation - ..... h2so4/hno3 . cr2o?/hoac TLC GC ) Saponification --------^ Ale - KOH Glycol - KOH - Two Column GC-EC --DMC -FID - GC/Mass - Reaction/GC - - IR -- S.C.O.T. Co1. fingerprint (product ident.) EC DMC FID IR ) STLCOPCB4040175 SUPPLEMENT TO GENERAL ANALYTICAL OUTLINE WATER (Measure) Extract and Hexane Concentrate . Check with EC/GC Concentrate TLC or Chemical Separation Check with EC/GC S.C.O.T. Col/FID fingerprint GC/Mass . SEDIMENT Dry Grind Measure Extract with acetonitrile Concentrate Check with EC/GC Concentrate . TLC or Chemical Separation Check with EC/GC .- S.C.O.T. Col/FID fingerprint GC/Mass TISSUES N * Measure Extract and/or Homogenize with Hexane Polar/Non-polar Solvent Part. Concentrate Alumina Column Concentrate Check with EC/GC TLC or Chemical Separation Check with EC/GC ' S.C.O.T. Col/FID fingerprint GC/Mass 4-18-69 DsW 152830 STLCOPCB4040176 RELATIVE RETENTION TIMES OF AROCLORS AND SOME PESTICIDES ON QF-I FLUOROSILICONE COLUMN (p,p DDE = 8.1 Min. =100) Instrument: F&M Model 402 High Efficiency Gas Chromatograph Type of Detector: Electron Capture - high temperature Ni3 cell (pulsed voltage type) glass U shaped .. Column: 6 MM (OD) X 6 M 6% QF-1 on 80/100 Mesh Chromosorb W Column Temperature: 190C . Detector Temperature: 250C . Injection Port Temperature: 225C Sample Volume: 1-5 pi .. Flow Rates Helium (carrier gas) 60 ml/min. Argon Methane (purge gas) 185 ml/min. ' Aroclor 1242: 9, 13, 18/ 20, 24, 28, 33, 38, 42, 45 , 54, 65, 71, 82, 95, 103, 123 , 153 . Aroclor 1248: 24, 29, 33, 39, 43, 46, 55, 66, 72, 80, 83, 96, 104, 125, 154, 164, 206, 252 ,314. Aroclor 1254: 23, 28, 45, 54, 71, 77, 94, 103, 125, 132, 145, 154, 164, 206, 250, 314. Aroclor 1260: 24, 29, 38, 46, 66, 77, 90, 109, 133, 145, 165, 202, 252, 311, 381, 476. Aroclor 1262: 66, 78, 90, 100, 110, 133, 145, 166, 202, 253, 310, 381, 478, 531. Aroclor 1268: 73, 131, 165, 180, 228, 251 , 300, 317 , 342, 474, 541. 1) Lindane - 41 2) Heptachler - 45 3) Aldrin - 51 4) pp * DDE - 100 5) pp' DDD - 120 4- 18-69 6) op' DDT - 127. 7) Dieldrin - 142 8,9) Endrin, pp* DDD - 170 10) Methoxychlor - 292 0Siv -1 STLCOPCB4040177 AROCLORS g X 10 1242 1248 1254 1260 1262 1268 5.18 5.11 5.11 5.35 5.03 5.00 PESTICIDES g X 10 <3 Endrin Keptachlor / Lindane 7.0 Methoxychlor orp DDT pp * DDE pp' DDD 3 Aldrin 7 Dieldrin 5.13 5.22 5.50 5.17 5.46 5.18 5.63 5.08 5.04. 4-18-69 SW 152832 STLCOPCB4040178 CO CO CO CinM </> D STLCOPCB4040179