Document 8543NvmgnB9kQXQamQZvb17we
\
D. A. Olson - St. Louis
Hay 4, 1970 NONELECTRICAL AROCLOKS
J. Kaaon
B. S. Bergen - HBERG N. T. Johnson - NJOHH W. B. Papageorge - WPAPA Vs R. Richard - WRLCH
Functional Fluids markets approximately 1.6 alllion pounds of Aroclor for Blscellanoeus industrial uses. These are Aroclor 1242, 1248, 1254, and 1260. The major applications are extreme pressure additives, transmission seal swell additives, end competitive fire resistant hydraulic fluid manu facturers. There are also several minor applications.
With the exception of competitors, all customers will be notified by T ^
personal contact or letter by May=L5 that we will no longer sell non- v
electrical Aroclor after July-31, 1970. ... -
^ ia, / 7 o
'U'
This action will remove 1.16 million pounds of Aroclor from uses which are
difficult to contain. In many cases, we will be able to supply alternate
products. The major customers affected are]
Voltme ML
Product
Possible Alternate
__ "t-
Radiator Specialty Belray Cincinnati Hilling Standard Oil-Ohio Lubrlzol
360,000 100,000 300,000
72,000 66,000
1242 1248/1254 1254 1254 1254/4465
1232 Terphenyl/122! Terphenyl/1221 Terphenyl/1221 Terphenyl/1221
The remaining 400,000 pounds are sold to Hobil Oil, Cltleo Service, and others, for formulation into Pydraul-like fluids. We plan to take no immediate action with these until our own Pydraul timetable is determined. Cur approach will be to put them under restrictions and timing similar to our own program.
(In order to control future use of these industrial Aroclors, all order center personnel will be advised to accept no orders without permission from St. Louis.
D. A. Olson /ph
DSW 332936
STLCOPCB4079512
D. A. Olson - St. Louis May 4, 1970 THERMIBOL - PCB
H. S. Bergen - HBERG
J. a. Fallon/D. E. Roush
B.W. Papagcorgc - WPAPA W. a. Richard - WRICK
J. Mason
We ere currently implementing Therminol FR marketing programs to prevent environmental problems. These are divided into Food Applications and other (primarily industrial) uses.
Food Applications
We have 84 customers, with a minimum volisae of 25,000 gallons in present systems. Primary applications are for vegetable oil processing and fry ing units for fish, potatoes, and donuts.
Actions taken:
SJ 1. Effective immediately, no new food installations will be sold Therminol FR.
2. Present customers will be informed, by letter dated before MayHLS, that:
. We will not supply them FR after July 31 for their systems.
b. We recommend they convert their systems from PR as soon as possible.
3. We will work with present customers in an attempt to convert them to Therminol 66. Ue will also offer to take back their used FR fluid, with the customer paying freight and Monsanto providing disposal at no cost.
gon-Food Applications
1. We will have definitive instructions to our salesmen by May 15 which will give clear design guidance on requirements for FR systems. These will be arrived at ensuring systems are closed to the environment and will include directions on types of welds, design of expansion tanks, evaluation of user application, etc.
2. In order to prevent loss of r.pent fluid to the environment, we will impress upon customers the disposal aspects and will offer to take back fluid for disposal with the same policy in effect to the electrical industry.
/ph
D. A. Olson
STLCOPCB4079513