obvious A few measurements of "high" concentration, evaluated by an inadequately trained man may shut down an operation re sulting in considerable financial loss On the other hand, with insufficient attention to the limitations of these instruments, it is quite possible to get seemingly "safe" read ings and still have a real hazard leading to occupational disease and excessive work losses
Direct-reading vs lab analysis
There is no real qualitative distinction between direct-reading and laboratory ana lytical techniques, and in some cases they overlap For example, to measure die air borne concentration of hydrogen chlonde, the industrial hygienist could have the chem ist make up a solution containing known amounts of sodium hydroxide in a series of bubblers or impingers The contaminated air could be drawn through each bubbler at a measured rate for a fixed period of time and the samples returned to the laboratory There, the excess sodium hydroxide would be back-titrated by the chemist with hydro chloric acid and the air concentrations of hydrogen chloride calculated This is the laboratory analysis method
However, the industrial hygienist could have the chemist make up a smaller quantity of sodium hydroxide in each bubbler and place an indicator m the solution In the field, the industrial hygienist could bubble air through the solution at a known rate and measure the time it took to obtain a color change in the bubbler From the volume of air drawn through, he could determine the air concentration of hydrogen chlonde by a very simple calculation This is es sentially a direct-reading method
Both methods are adequate for measunng the. air concentration at the point of sampling In both methods, the reagents were pre pared by a trained chemist In one case the industnal hygienist took a sample for a fixed penod of time, and m the other he sam pled until he saw a color change Essentially, no difference in skills is required in the direct-reading method, he can now take his second sample with the bets about his first result already on hand
This is the crucial difference between the methods and here is where the user of the
direct-reading method must be wary He may be led on a trail of seeking higher or lower concentrations and away from his ob jective of measunng the man's exposure under truly representative conditions A certain impartiality, created by ignorance of the immediately preceding results, may help in obtaining a more representative sample On the other hand, a trained industnal hy gienist can utilize this progressively increas ing knowledge of results to sharpen the pre cision of sampling
Safety professionals have been using directreading instruments for many years for de tecting combustible and explosive gases and have saved many lives as a result In the case of explosive gases, peak concentrations, not related to a man's exposure, must be mea sured Explosive limits are physical con stants which can be modified only within narrow limits, in contrast to threshold limit values which must be interpreted broadly
With a full knowledge of the facts, the trained industnal hygienist is m a position to utilize the direct-reading instruments to considerable advantage He can take more samples, get closer to the breathing zone, screen out areas for more detailed study, search out specific sources of air contami nation, and adequately evaluate the workers' exposure
Evaluating the Hazard
Evaluation of environmental exposures re quires teamwork by several professional disciplines no single group can solve all the many problems presented by occupa tional disease For example, the engineer ordinarily collects atmospheric samples in the field for subsequent chemical analyses In many cases, however, the chemist must go into the field to assist with the collec tion of samples and to advise on the chem ical aspects of the particular problem under study
The evaluation of an industnal health hazard requires some knowledge of toxi cology and an understanding of the con cepts involved in the use of threshold limit values and maximal acceptable concentra tions
The following material in this section on