CLEAN AIR ACT INSPECTION REPORT CDE Truck and Repair, Joliet, Illinois
Marie St. Peter, Environmental Engineer AECAB (MN/OH)
Dakota Prentice, Acting Section Chief AECAB (MN/OH)
File
BASIC INFORMATION
Facility Name: CDE Truck and Repair
Facility Location: 2123 S. Chicago St., Joliet, Illinois
Date of Inspection: June 22, 2019
EPA lnspector(s): 1. Marie St. Peter, Environmental Engineer 2. Ethan Chatfield, Environmental Engineer
Other Attendees 1. David Vargas, Owner, CDE Truck and Repair
Contact Email Address: cdetruckandcarrepair@hotmail.com
Purpose of Inspection: Clean Air Act (CAA) Title II - Vehicle and Engine Tampering
Facility Type: Heavy-duty diesel-engine maintenance garage
Regulations Central to Inspection: CAA Section 203(a)(3)(a) and 203(a)(3)(b)- motor vehicle tampering and defeat device prohibitions
Arrival Time: 11 :50 AM Departure Time: 2: 16 PM
Inspection Type: IZI Unannounced Inspection
D Announced Inspection
OPENING CONFERENCE
IZI Credentials Presented IZI CBI warning to facility provided
The following information was obtained verbally from Mr. David Vargas unless otherwise noted.
Process Description: CDE Truck and Repair (CDE) is an automotive repair shop that provides multiple services, including exhaust system repairs and oil changes to heavy duty diesel vehicles.
Staff Interview: Mr. Chatfield and Ms. St. Peter talked to Mr. Vargas about the general operations at CDE. He said that they do general repairs and maintenance to semi-trucks. When asked about potential engine control monitor (ECM) work, Mr. Vargas stated that CDE does not alter the ECM's fuel injection timing or emission controls. Additionally, in certain cases, CDE has replaced the ECM in a vehicle. When asked about the source of a replacement ECM, Mr. Vargas stated CDE typically sources them from dealerships; yet, at the same time, the customer is allowed to acquire a cheaper ECM from a junkyard. Mr. Vargas also stated that CDE outsources its ECM programming to the dealer, and that some junk yards have reprogrammed the ECMs it receives from customers. Mr. Vargas stated that CDE has never removed any emission controls.
When asked about diesel exhaust fluid and diesel particulate filter (DPF) work, Mr. Vargas said CDE does the regeneration portion of the work and then sends the equipment out to be cleaned.
Additionally, after inspecting two heavy-duty diesel engines, Mr. Vargas discussed some of the recent work that had been done on those vehicles. The first, was a 2010 Freightliner semi-truck with a Detroit Diesel engine. He said that it has a major oil leak, but that no engine work had been nor was planned to be done on that vehicle.
The second was a 2008 Peterbilt semi-truck with a Cummins engine. He said that it has had its EGR replaced two or three times. The first time was two or three years prior to the time of EPA' s inspection. That replacement was covered under the manufacturer's warranty. Mr. Vargas also stated that it had a bad catalytic converter, received an oil change, and had some DPF problems. Regarding the DPF problems, CDE had sent the filter out to be cleaned but still needed to go through its regeneration codes.
TOUR INFORMATION
EPA toured the facility: Yes
Page 2 of 4
Data Collected and Observations: EPA performed on-board diagnostic (OBD) scans on two vehicles (Attachment 1) Vehicle inspection worksheets were completed on two vehicles (Attachment 2)
Photos and/or Videos: were taken during the inspection. Field Measurements: were taken during this inspection.
RECORDS REVIEW
No records were reviewed on site
CLOSING CONFERENCE
Requested documents: At the time of inspection, EPA did not request any additional documents.
SIGNATURES
Page 3 of 4
Facility Name: CDE Truck and Repair Facility Location: 2123 S. Chicago St., Joliet, Illinois Date of Inspection: June 22, 2019
APPENDICES AND ATTACHMENTS
1. Appendix A: Digital Image Log 3. Attachment 2: Physical/OED Inspection Worksheets
Page 4 of 4
Facility Name: CDE Truck and Repair Facility Location: 2123 S. Chicago St., Joliet, Illinois Date of Inspection: June 22, 2019
APPENDIX A: DIGITAL IMAGE LOG
1. Inspector Name: Marie St. Peter and Ethan Chatfield
3. Company/Facility Name: CDE Truck and Repair
5. Number of Images:
31
2. Date(s) of Inspection:
June 22, 2019
4. Street Address, City, State:
2123 S. Chicago St., Joliet, Illinois 6. Archival Record Location:
CD-R Labeled as "CDE Truck and Repair Inspection Photos and OBD Scans, June 22, 2019"
Image Number
1
File Name
P522000 l.JPG
Date and Time (incl. time zone and DST)
2019:05:22 12:14:04
2
P522000 2019:05:22 12:14:15
2.JPG
3
P522000 2019:05:22 12:15:49
3.JPG
4
P522000 2019:05:22 12:29:32
4.JPG
5
P522000 2019:05:22 12:42:09
5.JPG
6
P522000 2019:05:22 12:42:20
6.JPG
7
P522000 2019:05:22 12:43:14
7.JPG
8
P522000 2019:05:22 12:43:21
8.JPG
9
P522000 2019:05:22 12:48:36
9.JPG
10
P522001 2019:05:22 12:50:19
0.JPG
Latitude and Longitude 41.484558,
-88.083315 41.48442,
-88.083322 41.48433,
-88.083293 41.484353,
-88.08325 41.484317,
-88.083278 41.484317,
-88.083265 41.484323,
-88.083258 41.484323,
-88.083258 41.484318,
-88.083265 41.484167,
-88.083056
Description of Image
Truck #1 - Prime Line Transportation Operated Vehicle Truck #1 - Profile View of Hood Internals
Truck#l-VINNumber
Truck #1 - DelcoRemy Alternator
Truck #1 - Hood Internals Aerial View
Truck #1 - Hood Internals Aerial View Number 2
Truck #1 - illegible Engine Labels
Truck# 1 -Illegible Engine Labels (2)
Truck# 1 - Aerial After Treatment System
Truck# 1 -After Treatment System Pressure Sensor
Appendices Page 1 of 3
Facility Name: CDE Truck and Repair Facility Location: 2123 S. Chicago St., Joliet, Illinois Date of Inspection: June 22, 2019
11
P522001 2019:05:22 12:50:44
41.484367, Truck # 1 - Aerial View of
1.JPG
After Treatment Systen
-88.083378
12
P522001 2019:05:22 12:50:56
41.484365, Truck# 1 -After treatment
2.JPG
System
-88.083305
13
P522001 2019:05:22 12:51:03
41.484365, Truck # 1 - After treatment
3.JPG
System
-88.083305
14
P522001 2019:05:22 13:09:58
41.484115, Truck# 2 - 2008 Peterbilt
4.JPG
Dashboard
-88.082812
15
P522001 2019:05:22 13:10:11
41.484022, Truck# 2 - Manufacturer
5.JPG
info (including VIN
-88.08279
number)
16
P522001 2019:05:22 13:10:17
41.484022, Truck # 2 - Date of
6.JPG
Manufacture
-88.08279
17
P522001 2019:05:2213:11:32
41.484153, Truck# 2 - Aftertreatment
7.JPG
System w/ Pressure Sensor
-88.082883
18
P522001 2019:05:22 13:11:54
41.484233, Truck# 2 -Aftertreatment
8..TPG
System w/ Pressure Sensor
-88.08284
19
P522001 2019:05:22 13:13:37
41.484257, Truck# 2 - Aftertreatment
9.JPG
System w/ Pressure Sensor
-88.082823
20
P522002 2019:05:22 13:21:04
41.484167, Truck # 2 - Cummins
O.JPG
Engine Serial No.
-88.082778
21
P522002 2019:05:22 13:21:13
41.484263, Truck #2 - Cummins Engine
l.JPG
Serial No (2)
-88.082925
22
P522002 2019:05:22 13:22:02
41.484277, Truck # 2 - Cummins
2.JPG
Engine Information
-88.082917
23
P522002 2019:05:22 13:22:10
41.484277, Truck # 2 - Cummins
3.JPG
Engine Information (2)
-88.082917
24
P522002 2019:05:22 13:23:04
41.48428,
Truck# 2 - Cummins
4.JPG
Engine Logo (3)
-88.082905
25
P522002 2019:05:22 13:24:05
41.484167, Truck # 2 - Cummins EGR
5.JPG
-88.082778
Appendices Page 2 of3
Facility Name: CDE Truck and Repair Facility Location: 2123 S. Chicago St., Joliet, Illinois Date of Inspection: June 22, 2019
26
P522002 2019:05:22 13:24:15
41.484312,
6.JPG
-88.082867
27
P522002 2019:05:22 13:24:29
41.48432,
7.JPG
-88.082868
28
P522002 2019:05:22 13:25:07
41.484167,
8.JPG
-88.082778
29
P522002 2019:05:22 13:31 :20
41.484167,
9.JPG
-88.082778
30
P522003 2019:05:22 13:31:40
41.484167,
0.JPG
-88.082778
31
P522003 2019:05:22 13:33:15
41.484272,
l.JPG
-88.082747
Truck# 2 - Cummings Engine Profile View
Truck # 2 - Cummins Intake Manifold
Truck# 2 - Cummins Intake Manifold
Truck# 2 - OBD Photo of Fault Codes
Truck# 2 - 2008 Peterbilt Dashboard
Truck# 2 - Fault Codes/ Non matching VIN