Document 82kd1bKajEX3pDka0ke04RBDK
Boilers and Radiators
National Radiator Corporation
General Offices: Johnstown, Pa.
Branch Offices and Warehouses
Baltimore............................................2622 Frisby Street Boston................................................. 93-97 Oliver Street
Buffalo................... ............ 269-265 Delaware Avenue Chicago............................2445 North Keeler Avenue
Cincinnati........... Spring Grove and Elmira Avenue Cleveland.....................,,.935 East Sixty-third Street Indianapolis............................. .431 W. Georgia Street Johnstown........................... ............221 Central Avenue
Milwaukee............................124-130 Jefferson Street
New Vnag ...... ..............55 West Forty-second Street Omaha.......................,........_.108-112 S. Tenth Street Philadelphia........................-121 North Broad Street Pittsburgh........ ............................ 1509 Arrott Building Richmond.......................................... 3032 Norfolk Street
St. Louis.;.................... 1042 Central Industrial Street Washington, D.C2205 Fifth Street, N.E,
Manufacturers of
Aero Radiators, National Round Boilers, National Jacketed Boilers, SuperSmokeless Boilers, Imperial Sectional Boilers, Low Water Line Boilers, Contento Boilers and Gas Boilers.
1 I1 3
IHaS
Wall Radiator
Aero Radiation
StyleSteam or
Water
Distance
from Floor to Center
of Top Tapping
,,Height in Square Feet Section
3 TubeWidth of Section
5%'
4 Tube-- Width of Section
6-*'
5 TubeWidth of Section
8%'
6 TubeWidth of Section
9*
7 TubeWidth of Section
12*
33*4 27% 23% 17%
33% 27% 23% 17%
33% 27% 23% 2096 17%
35% 29'/, 23'/, 20V, 17%
33% 27% 23% 17% 14% n%
36 30 26 20
36 30 26 20
36 30 26 23 20
38 32 26 23 20
36 30 26 20' 16% 13%
3% 3
2* i%
4%
3% 2% 2%
5
4*
3% 3
Five-Tube Radiator
m
6 5 4
3% 3
6%
3% S? 3H 3% 2H
Floor to center bottom tapping--4H in. Excepting 13H in. and 16}$ in. 7 Tube which is 3 in.
Legless Radiator
National Aero Wall Radiation
Sections Number
5A 7A 9A 7B 9B
Height Inches
13*6 13*6 13*6 21%
29*
Length or Width
16% 21%
29*6
13* 13*
Center to
Sa. Ft. Per
Center lappings Section
10*6 10*6 10*6
18% 25%
5 7 9 7 9
Thickness of sections--2% in. 550
National Radiator Corporation
Boilers and Radiators
National
Super-Smokeless
Boilers
The patented baffle sec tion separates the primary and secondary combustion chambers. The volatile . gases from the coking coal in front are intimately mixed with secondary air and consumed' smoke lessly. The rotative fire travel scours the flue ways resulting in maximum heat transfer.
Boiler Steam Number Rating
Water Rating
' Crate Area
Sq. Ft.
Length of Length of Number Sections Sections and of Outlets
Only Smoke Box Sizes in In. In. In.
Chimney
Area In.
Height Fl
24 Salts--Height of Water Line, 4PA". Height Float Outlet, 54*. Width qf Sections--3PA*-
245
1600
2600
5.00
37%
48%
1-4* 12x12
246
2000
3250
6.25
45%
56%
2-4* 13x13
247
2400
3900
7.50
53%
63%
2-4*
13x13.
248
2800
4550
8.75
62
71%
2-4*
14x14
249
3200
5200
10.00
70%
79%
3-4'
14x14
33 Series-* /eight of Waler Lint, 53* . Height Flow Outlet, 64 A*. Width of Sections--<7'.
335
2900
4650
7.32
371/.
49%
1-5' 14x14
336
3600
5800
9.10
45%
57%
2-5* 15x15
337
4300
6950
10.87
53%
66
2-5'
16x16
338
5000
8100
12.65
62
72%
2-5*
16x16
339
5700
9250
14.42
70%
80%
5-5*
18x18
3310
6400
10400
16.20
78%
89
3-5'
18x18
40 Series--. Height of Water Line, J/J . Height F out Outlet, byK Width Sections--57%*.
405
4200
6700
9.68
37%
49%
1-5* 15x15
406
5200
6300
12.03
45%
57%
2-5*
16x16
407
6200
9900
14.38
53%
65%
2-5' 18x18
408
7200
11500
16.73
62
74
3-5' 18x16
409
8200
13100
19.08
70%
82%
3-5'
20x20
4010
9200
14700
21.43
78%
90%
3-5* 20x20
4011
10200
16300
23.77
86%
97
3-5* 21x21
4012
11200
17900
23.77
95
105%
4-5'
22x22
4013
12200
19500
23.77 103%
113%
4-5*
22x22
4014
13000
20800
23.77 m%
121%
4-5' 23x23
4015
13800
22100
23.77 119%
130
4-5' 23x23
4016
14600
23400
23.77 128
138%
* 4-5'
24x24
4017
15400
24700
23.77 136%
146%
4-5'
24x24
4018
16200
26000
23.77 144%
154%
4-5'
25x25
4019
17000
27300
23.77 152%
163
5-5' 25x25
4020
17600
28200
23.77 161
7I%
5-5' 25x25
4021
18200
29200
23.77 169%
179%
5-5' 25x25
. 4022 4023
18800 19400
30200 31200
23.77 23.77
177% 185%
187% 196
5-5' 5-5'
26x26 27x27
4024
20000
32200
23.77 194
204%
5-5' 27x27
40 40 45 50 55
40 40 40 50 50 55
50 50 50 55 55 60 60 65 70 75 75 80 80 80 85 90 100 100 100 100
Boiler Covering Sq. Fl Surface
34 42 50 58 64
42 . 51 60 69 78 87
46 50 66 76 86 96 106 116 126 136 146 156 166 176 186 1% 206 216 226 Z36
Square feet of exterior boiler surface. Approximate number of pounds of oovering per boiler section, 24 series, 50 lb.; 33 series, 60 lb.; 40 series, 67 lb.
National Duplex Super-Smokeless Boilers
827 828 829
8210 8211 8212 8213 8214 8215 8216 8217 8218
13200 15200 17200 19200 21200 23200
25200 26600 28400 30000
31600 33200
21100 24300 27500 30700 33900 37100 40300 42900 45500 46100 50700 53300
28.76 28.76 33.46 33.46 38.16
38.16 42.66
42.86 42.86 47.54 47.54 47.54
53% 62 77i0%
95 103% !8
128 136% . 144%
70% 79 87%
112 120%
145 153% 161%
1-8' 23x23 1-8' 24x24 1-8' 25x25 1-8' 26x26
1-8' 27x27
1-8' 28x28
1-8' 29x29 1-8' 29x29
1-8' 30x30
1-8' 31x31
1-8' 32.32
1-8' 32x32
60 90 65 104 65 . 118 70 132
70 146 75 160 80 174 65 168 85 202 90 216 90 230
90 244
Height of Water line, 57 in. Height to Center of Outlet, 81H in- Width of Boiler, U5N in. Regularly furnished with cast iron header, but can be furnished without header when so ordered. Square feet of exterior boiler surface. Approximate number of pounds of boiler oovering per section, 94 lb.
551