Document 82Lv1vZQB7mJyL86BVKyp6j7a
TECHNICAL SPECIFICATIONS
CertainTeed El
CertainTeed Corporation Pipe and Plastics Group
description:
SPECIFICATIONS CLASSIFICATION:
A/C Standard Product Specification
T.C.O. REF. NO.
47
SPECIFICATION NO:
2 Section A
PAGE NO..*
4-1
SUPERSEDES:
February 18, 1977
OATE OF issue:
MAR 51979
FLUID-TITE A/C Sewer Pipe, Couplings, and Accessories Classes 1500, 2400, 3300, 4000, 5000, 6000 and 7000 Sections A and B
SECTION A
CONFORMANCE
All pipe manufactured under "Section A" of this specification will meet the requirements of the following external specifications:
- Southern Building Code Congress - International Association of Plumbing and Mechanical Officials Code - ASTM C-644
PIPE LENGTHS
Standard Length - 13'0". Plants 258 and 259 may also supply 6'6" as standard lengths when ordered.
Random Lengths
- 7'0" to 12'6" in 6 inch increments Plants 258 and 259 may also supply 4'0" to 6'0" in 6" increments, when 6'6" standard lengths are ordered.
Short Lengths - 12", 24", 36" (M.E.0.) Note: A maximum of 10 percent of the total footage of any one size for any one order may be furnished as random lengths.
Tolerance "Tr
t i"
+.50"
STANDARD COUPLING
One Coupling suitable for the particular size and class of pipe with which it is to be used, shall be furnished with each standard, random, and short length. Couplings will be shipped in cartons or crates depending on the size of the order.
CTD015298
PREPARED BY:
APPROVED BY:
>v-^
02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
Page 4-2
PHYSICAL REQUIREMENTS
Crushing Strength
Each pipe, in accordance with these specifications, shall have sufficient strength, when subjected to a three (3) edge bearing crushing test, to support not less than the indicated load shown in the following table:
Nominal Pipe Size, Inches
Minimum Crushing Strength, Pounds Per Foot
Class 1500
Class 2400
Class 3300
4
1500
2400
3300
5
1500
2400
3300
6
1500
2400
3300
- Couplings must also be capable of meeting the crushing strength requirements, as specified for the appropriate size and class.
- The crushing strength test shall be conducted in accordance with Standard Method of Test ASTM C-500. The specimens shall be cut from one randomly selected pipe representing 500 lengths for 13' lengths, and one per 1000 for 6'6" lengths of the same size, class, and production lot.
- Plants .256 and 260 the specimen shall be randomly selected from each 300 lengths.
Flexural Proof Loads
Each 10' through 13' length of pipe shall be tested in flexure across a span of 9 or 12 feet. Each pipe so tested shall support without evidence of cracks or other stress induced defects, the applicable total load is shown in the following table:
Flexural Proof Loads
Total Applied Load, Lbs. (12 Ft. Span)
Nominal Pipe Size, Inches
Class 1500
Class 2400
Class 3300
4
415
415
415
5 715 715 715
6
1125
1125
1125
Note:
The above loads are 75 per cent of the loads required for testing on a span of 9 feet. Flexural strength tests are conducted in accordance with Standard Method of Test ASTM C-500 (latest issue).
Joint Test
The purchaser by designation with his order may require a proof demon stration test, on at least one size pipe on the order, to assure that assembled pipes and couplings pass the following performance tests without leaking.
CTD015299
TECHNICAL SPECIFICATIONS
CertairileedEI
SPECIFlCATIONS CLASSIFICATION:
A/C Standard Product Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PAOC no.:
CertainTeed Corporation Pipe and Plastics Group
49 2
supersedes:
March 5, 1979
Section A
4-3
DATE Or ISSUE:
SEP 2 3 1979
DESCRIPTION:
FLUID-TITE A/C Sewer Pipe, Couplings and Accessories Classes 1500, 2400, 3300, 4000, 5000, 6000 and 7000 Sections A & B
Straight Alignment - A hydrostatic pressure test shall be made on an assembly of two sections of pipe, properly connected with a coupling in accordance with the joint design. An equivalent alternative may be a single pipe with a coupling on each end. The assembly shall be subjected to an internal hydrostatic pressure of 10 psi for 10 minutes and any visible leakage shall be considered a failure of the test requirement.
Maximum Deflected Position - Upon completion of the test for pipe in straight alignment, the test sections shall be deflected 5 degrees (with one half of the deflection being between each pipe and coupling) and shall be subjected to an internal hydrostatic pressure of 10 psi for 10 minutes. Any visible leakage shall be considered a failure of the test requirement.
If the selected sample(s) fail, two additional samples shall be tested, failure of either of these assembled units to meet either test require ment shall be cause for rejection of the entire quantity of pipe repre sented by the samples.
Straightness
Each length pf pipe shall not vary in straightness by more than 1/16 inch/ft. of length when measured in accordance with C-500. In plants 256 and 260 each 13 ft. length of pipe may not exceed 5/8 inch.
MARKING
Standard, Random and Short Lengths
Standard Coupling
CTD015300
Unless otherwise directed, marking 4", 5", and 6" A/C Sewer Items
shall be in green ink.
PREPARED RY:
APPKWfcu ef:
R *O
MFO.
>P
m m
I.C.
OTHERS
m A j.e.A
SEP 2 8 1973
Page 4-4
Standard, Random and Short Lengths
At either end of the pipe, a "handling label" (see Sec. D of the General Standards Manual) shall be attached to the B.O.D. of all pipe 1/4-length and above.
Area A - At the exact center of the pipe, the following shall be stamped.
Example;
CERTAINTEED
SIZE-CLASS TYPE II
FLUID-TITE SEWER
.
CERTAINTEED 4"-1500 TYPE II FLUID-TITE SEWER
Refer to I.E. Pipe stamp Purchasing Spec. 557.
Area B - To the right of Area A, the following information shall be stenciled in black ink on all Standard Lengths.
1
Interpretation;
First Line - Month, Day, Year, Plant, Shift
Example: 0719788 A July 19, 1978 Plant 58 on A shift
Second Line - Pipe No.
139
Pipe No. 139
These markings must appear on all standard lengths of pipe. On short and random lengths, the date and plant number must appear.
Standard Coupling
* Area C - At the approximate center around the coupling, the following shall be stamped.
Example:
CERTAINTEED SIZE - CLASS FLUID-TITE SEWER
CERTAINTEED | 6" 3300
j FLUID-TITE SEWER
Refer to I.E. Pipe stamp , Purchasing
Spec. 557.
* Note :
Plants 56 and 60 (Santa Clara and Riverside) are to show the "In<emational Association of Plumbing and Mechanical Officals" logo on pipe and couplings, sizes 4", 5", 6", Classes 1500 and 2400. Refer to Industrial Engineering Pipe and Coupling stamps.
CTD015301
TECHNICAL SPECIFICATIONS
SFCCIFICATIONS classification:
Certairileedlil
A/C Standard Product Specification
T.C.O. REP. NO.
SPECIFICATION NO:
PAGE NO.:
CertainTedd Corporation Pipe and Plastics Group
pcacmmoN:
50
buperbcocb:
March 5,
2 Section A 1979
4-5
DATE OF ISSUE.'
MAY 28 1980
FLUID-TITE A/C Sewer Pipe, Couplings, and Accessories Classes 1500, 2400, 3300, 4000, 5000, 6000 and 7000 Sections A and B
Special
Some small diameter sewer fittings are designed to serve more than one purpose and require a pressure-sensitive label for identification. These fittings are:
1. Sleeve Adaptors - page 4-7 2. Increaser Adaptors (D.I. to A/C) - page 4-7 3. Adaptor Bell and Spigot - page 4-8 4. Duplex Adaptor Couplings - page 4-8
The label (see example below) shall be applied to each fitting on the un machined O.D. and the appropriate box, dependent on end usage, shall be checked.
These fittings are shipped in cartons per Section L of the General Standards
Manual - pages 1-2-4, 2-3-4 and 2-3-5.
_.
Label Example:
CTD015302
CERTAIN-TEED.
SMALL DIAMETER SEWER
CAT NO.
CONNECT TO:
RINGS TO Let.
87655
6" Cot Iron SW to 6" A/C
One 6" FLUID-TtTE* One .75 x 7.17
87663
6" Cast Iron XH to 6" A/C
On* 6" FLUID-TITE* One .66 x 7.17
87664
6" A/C to 6" A/C
One 6" FLUID-TITE* On# .375 x 6.97
[ COTAIIt-TEEO PRDDilICTS CORPORATION, Pipe end Plastics Group, Valley Forge, Pa 13402
PREPARCO by:
02-10-0023 (P927)
approved by:
R *O
M j.e.A
12/76 CONFIOCNTIAL DOCUMENT - NOT TO BE DISTRIBUTED TO UNAUTHORIZED PERSONNEL
ocecmntOH:
DATE OP IMUC:
MAY 2 8 1980
SPECIFICATION NO:
2 Section A
paoc no.:
4-6
FLUID-TITE A/C Sewer Pipe, Couplings and Accessories Classes 1500, 2400, 3300, 4000, 5000, 6000 and 7000 - Sections A & B
STANDARD PIPE
dl JED
Length of Pipe
Dimensions
Refer to page 4-1 of this specification.
Pipe Size Inches
-Class
nominal I D #f1
Uelle]^ +.02"
.02*
1500 2400 3300
4.00 4.00 4.00
4.62 4.62 4.62
4.78 4.78 4.78
1500 2400 3300
5.00 5.00 5.00
5.66 5.66 5.66
5.82 5.82 5.82
1500 2400 3300
6.00 6.00 6.00
6.66 6.66 6.66
6.82 6.82 6.82
STANDARD COUPLING
B.O.D." Min
4.81 4.87 5.01
5.91 5.98 6.20
6.91 7.04 7.22
t" P
.20 .20 .20
.22 .22 .22
.24 .24 .24
mm.
J=.35"+.03"-.00" R=.156" .010" 0C"=13 + 20
Pipe Size Inches
4
5
6
A" - .025"
5.24 6.28 7.28
B" ^.025"
B.O.D." +.25" -.00"
Class 1500
Class 2400 Class 3300
4.71 5.75 6.75
5.92
7.06
8.12
5.92 7.06
8.12
6.00
7.14
8.20
CTD015303
TECHNICAL SPECIFICATIONS
CertairileedlH
FECIF1 CATION# CLASSIFICATION:
A/C Standard Product Snecification
T.C.O. REF. NO.
SPECIFICATION NO:
FAOE NO.:
CertainTee'd Corporation Pipe and Plastics Group
50
SUPERSEDES:
March 5,
2 Section A
4-7
1979
DATE OF issue:
.MAY 2 6 1980
MscitIPTION:
FLUID-TITE A/C Sewer Pipe, Couplings and Accessories Classes 1500, 2400, 3300, 4000, 5000, 6000 and 7000 - Sections A & B
ttfgyg ADAPTOR
Dimensions
Pipe Site, Inches
I.D. M +.030"
4 5.45 5 6.50 6 7.50
8.O.D." Min
6.42 7.50 8.67
Meriting: - Special, refer to pege 4-5 of this Specification.
Pipe Site, Inchee
4
5
6
Rubber Rings, per Standard Purchasing Specification Ho. 512
A/C Rough Barrel
,575" Die. X 5.08" O.D. ,375" Ole. X 6.07" O.D. ,375" Die. X 6.97" O.D.
Service Wt. C.I.
.750" Die. X 5.39" O.D. .750" Die. X 6.27" O.D. .750" Die. X 7.17" O.D.
Extra Heavy Wt. C.I.
.665" Die. X 5.38" O.D. .665" Die. X 6.27" O.D. .665" Die. X 7.17" O.D.
Note: 1. Sleeve Adaptor for use vlch any combination of A/C rough barrel (Class 1500 - 2400) Service Weight or Extra Heavy Weight Cast Iron.
IKCREASER adaptor CAST IRON TO SLOWER
Pipe Site, Inchee C.I. to A/C
CTD015304
Dimensions
Koa. i.oM"
I.D.j" +.030"
B.O.D." Kin.
2x4 3x4 4x5 4x6
2.95 3.80 4.70 4.70
3.20 4.10 5.10 5.10
4.81 5.04 6.06 6.91
Rubber Rinse For Cast iron End
Marking - Special - Refer to page 4-5 of this Specification.
Pipe SUc
2x4 3x4 4x5 4x6
Service Weight
.665" Dia. x 3.39" O.D. .555" Dia, x 4.03" O.D. .555" Dia. x 4.97" O.D. .555" Dia. x 4.97" O.D.
Extra Heavy Weight
e .555" Die. x 3.13" O.D. .375" Dia. x 3.55" O.D. .425" Dia. x 4.90" O.D. .425" Dia. x 4.90" O.D.
Note: 1, Refer to standard pipe for O.D.} and bevel*
2. All cast Iron end rings par A/C Standard purchasing Specification No. 512.
PREPARED BY:
asLr
02-10-0023 4/*o
APPROVED BY:
ft * O
MFO.
SALES
I.E.
Q. C.
M U4A
CONFIDENTIAL DOCUMENT - NOT TO BE OtSTRIBUTEO TO UNAUTHORIZED PERSONNEL
OTHERS
dcscmiption:
D4TR OF IMUC
MAY 2 8 1980
iirccincATioM mo: 2 Section A
PAOS MO.: 4-8
FLUID-TITE A/C Sewer Pipe, Couplings and Accessories Classes 1500, 2400, 3300, 4000, 5000, 6000 and 7000 - Sections A & B
DUPLEX ADAPTOR CO..TLI NG CLAY SPICOI TO A/C M.E.
-- A.SO'*2 5-PO`
_4.SCH-.25-.00*
2* .125*- |~2`Ofc2'-*
CAULK
THENISO
bud.
IQ|
isr*fs
Pipe Sice
Inches
4
5 6
Dimensions
No.
+<10?,
4.00
5.00
6.00
6.25
7.25 e.so
0.D." +.25" -.00"
7.19 8.23 9.54
Note: 1. Refer to standard coupling for mechlned dimensions not shown.
2. for standard strength end oxers heavy strength clay.
Harking Example:
CERTAIN-TEED DUPl. ADPT. CPLG. CLAY SPIGOT - A.C.H.E. 4" SEWER 15/24/3300 *
DUPLEX ADAPTOR COUPLTNC CONCRETE TO F.T. SEWER
Pipe Rite, Inchee
Dimensions
Rom. I.D, i"
I.D.V .10*
B.Q.D."
+.25" -.00"
4.35 6.35
6.35 8.9U
7.29 10.02
Dotoi 1. Refer to tend.rd coupling for mechlnod dlocnelon. not shown.
Dorking Exempl.i
CERTA1X-TEED DUEL. ADPT. CPLC. CONCRETE - rr. SEVER t" REVER 13/21/1100
CTD015305
3oa
6 6
;
TECHNICAL SPECIFICATIONS
SPECIFICATIONS CLAS SIPICATION:
CertainleedlH
A/C Staniiard Product Specifics
T.C.O. REP. NO.
SPECIFICATION NO:
PAOE NO.:
CertainTeed Corporation Pipe and Plastics Group
50
2 Section A
_ 4-9
SUPERSEDES:
DATE OP ISSUE:
March 5, 1979
MAY 28 19bu
OtaCRIPTION:
FLUID-TITE A/C Sewer Pipe, Couplings and Accessories
Classes 1500, 2400, 3300, 4000, 5000, 6000 and 7000 - Sections A & B
DUPLEX ADAPTOR COUPLIMC CAST IRON to SEVER
Pipe Site, Inches
4 5 6
Dimensions
Horn.
+.030"
4.35 5.35 4,35
3.45 6.50 7.50
. .8 0 D."
+.25" -.00"
6.42 7.50 8.67
Rubber Pint's* per Standard Purchasing Specification Ho. 512
pip* SUt, Inches
A/C Roup.1i Harrel
4 .375" Dla. X 5.08" O.D. 3 .375" Dla. X 6.07" O.D. 6 .375" Dla. X 6.97" O.D.
Service Ut. C.I.
.750" DU. X 5.39" O.D. ,750" Dla. X 6.27" O.D. .750" Dla. X 7.17" O.D.
Extra Heavy Ut. C.I.
.665" DU. X 5.36" O.D, ,665" Dla. X 6.27" O.D, .665" Dla. X 7,17" O.D,
Vote: Refer to standard coupling for nachlned dimensions not shown, Harking - Special - refer to page 4*5 of this specification.
CTD015306
IKCREASER ADAPTOR FLUID-TITE SEVER to fLUID-TITE SEVER
Harking Example:
CERTAIN-TEED
INCR. ADPT. F.T. SEWER - F.T. SEWER
4"S. x 5"S. 15/24/3300
Dimensions
Pipe Sire, Inches
klC to ktC
Kom. I.D.
B.O.D," +.25" -.00"
L" +.00" -3.0"
4 to 5 4 to 6 5 to 6
4.60 4.60 5.60
6.20 7.32 7.22
6.25 6.25 6.25
Vote: 1, Refer to Standard Pipe and Coupling pagea for machined dimensions not shown.
+.13" X" -,00"
2.25 2.25 2.25
2. Machining not required on 6.O.D. or I.D..
PRIPARKD BY:
10-0023 4/'0
APPROVED BY!
R ft D
MFG.
BALES
I.E.
OTHERS
M J.4.A-
CONFIDENTIAL DOCUMENT - NOT TO Be DISTRIBUTED TO UNAUTHORIZED PERSONNEL
description:
OATS OP IMOC:
MAY 2 8 1980
PCCIPICATION NOI
2 Section A
PADS NO.:
4-10
FLUID-TITE A/C Sewer Pipe, Couplings and Accessories
EHD CAP
Pipe Site, Inches
4 5 6
PlBfWltCM
Norn. I.D."
6.0.0." Min. .06" -.00"
4.00 5.00 6.00
5.92 7.06 8.12
L" +.25" -.00"
5.00 5.00 3.00
Ll" .06"
2.75 2.75 2.75
X" Min.
.25 .25 .25
Hi" ..W*
,oy*
1.65 1.6} 1.63
Site, inches
A/C Circular pise.
4 25" k4.6" 0.0. 5 .25" x 5.65" O.D. 6 .25" x 6.65" O.D.
Hot*: l. Refer to standard coupling for machined dimension* not eh am.
2. A/C Circular Discs per A/C Standard Purchasing Specification No. 553.
lurking Example:
CERTAIN-TEED END CAP
5" Sewer 15/26/5500
Pipe Site. Inches
4
6
SLEEVE ADAPTOR (A/C ROUGH BARREL TO CLAY)
Dimensions
I.D." .100"
R.O.O," Min.
6.00 6.50
7.00 9.50
Note: 1. For caulk connecting any combination of A/C Rough barrel (Claas 1500 and 2400) to Standard or Extra Heavy Clay.
Harking Example:
certain-teed SLEEVE ADPT. A.C. R.6. - CUT
ttVtR 15/24/3300
CTD015307
TECHNICAL SPECIFICATIONS
CertairileedEI
CertainTe^d Corporation Pipe and Plastics Group
DESCRIPTION:
SPECIFICATIONS CLASSIFICATION:
A/C Standard Product Specification
T.C.O. REF. NO.
SPECIFICATION NO:
PAGE NO.:
47 2 Section A
4-11
supersedes:
DATE OF ISSUE:
February 18, 1977
MAR 5 1979
FLUID-TITE A/C Sewer Pipe, Couplings, and Accessories
Classes 1500. 2400. 3300. 4000. 5000, 6000 and 7000 Sections A and R
z.orr
8BWEK TEE HIPPIE FOR FIELD COT MAINS
Harking ErapUi
BOD.
Dln*nlon
T -VSXD62
-.0*0 R.
Ntppl* Sic* Inchec
4 5 6
Now. T.D .*
4.00 5.00 6.00
B.O.D." Min.
5.50 6.50 7.50
0.0.!*
+.02*
4.62 5.66 6.66
CEXTAXH-TEED SEVER TEE NIPPLE *" SEVER x 12*
O.D.j* 4.02*
4.92 5.92 6.92
- Ltt-
CUXf
f .52402'
ADHESIVE BOND
Claaa 1500, 2400. 3300
6 8 10 12 14 15 16 18 20 %\ 24
Z Rot roqnlrod
Branch Sic* 4" 5" 6"
8.00 *.00 10.00 11.00 12.00
12.50 13.00 14.00 15.00 15.50 17.00
8.00 9.00 10.00 11.00 12.00 12.50 13.00 14.00 15.00 15.30 17.00
X 9.00 10.00
11.00 12.00 12.50 13.00 14.00
15.00 15.50 17.00
!( No. of Central
Engineering Dug. No. *641
(for contour cut)
Branch Sir*
4* 5"
6*
22 29 29 51 51 52 52
S3 S3 12 12 14 14 44 44 19 19 20 20 23 23
z 29 51 52
53 12 14 44 19 20
23
Retftt 1 Liability ( for material only* Rot responsible for vorkzuuhlp of
. drilling or epoicylng.
2 Adhealv* (epaxy) to be eupplled by Selea Department. 3. To be field cut by * pilot A/C Role Cutter or It* equivalent. Tor n
4" Nipple, use a 5" cutter shell, for a 5* Nipple use a 6" cutter
ahll, and for a 6* Nipple use a 7* cutter ahell. Addr*ac: Pilot Manufacturing Company
P.0. Box 3128
2043] Earl Street
Torrance, California *0503
CTDO^08
PREPARED BY:
0Q1
APPROVED BY:
R ft D
02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE C
:dvto unauthorized personnel
Page 4-12
CaTAIN-TEED *5 WYE
4"S.*4"S. 15/24/3300
t.ducln *" *2.00" + .0*2"
f ip* Sin, Hon. Inches 1.D.1"
5x4 5.60 6.60
6x5 6.60
Hot*. 1.0.7"
B.O.P.i"
0"
+.25M B.O.D.,* +.030"
-.Off*
Min. ..020"
4.00 4.00 5.00
7.06 8.12 8.12
4.87 4.87 5.96
4.89
4.69 6.00
P1bct1op
* h
7.63 8.50 8.50
T"
12.25 13.00 13.75
t.A." '
11.16 12.56 12.56
t" +.00"
-.50"
t.C." .06"
15.25 ' 17.00 17.00
11.25 11.30 12.40
L.B."
&22L
6.38 6.43 5.42
t.O." +.06"
4.18 5.05 4.27
11.08 11.95 12.73
K.n-8eductng
Up. Six.,
Hob.
Inchef i-r
4x4 3*5 4x6
4.60 5.6Q 6+60
Hon. t.Ol1*
4.00 5+00 6.00
B.O.D.i" +.25" -.00"
B.O.D.j" Min.
I!L
5.92 7.06 8.12
4.87 5.98 7.04
11.50 12.75 14.25
_ i
JX.
6..88 7 .63 8 .50
L,4,w
9.64 11.16 12.56
l"
+.00" -.50"
13.75 15.25 17.00
l.C." +.06"
9.80 10.70 11.88
L.8." +.06"
4.93 4.72 4.84
l.D."
.06"
3.43 3.40 3.51
t. 8." .06"
10.33 11.86 13.49
lattt 1. 8*fr to at.nd.rd eoupllng oachlntn* for aoto m+chlnln*. I, 8afr to at.ndrd pip* for aachtnlnc dta.oalon+ not ahoira.
CTD015309
TECHNICAL SPECIFICATIONS
CertairileedlH
CertainTeed Corporation Pipe and Plastics Group
description:
SPECIFICATIONS CLASSIFICATION:
A/c Standard Product Specification
T.C.O. REF. NO.
47
SUPERSEDES:
SPECIFICATION NO:
2 Section A
PAGE NO.:
4-13
DATE OF ISSUE:
February 18, 1977
MAR 5 1979
FLUID-TITE A/C Sewer Pipe, Couplings, and Accessories Classes 1500, 2400, 3300, 4000, 5000, 6000 and 7000 Sections A and B
45 Wve Fitting
Reducing
DimensIons
Marking Example:
CERTAINTEED 45 WYES
6"S. x 6"S. 15/24/3300
Pipe Size, Inches
Nom. I.D.l"
Nora. I.D.2"
6x4 6.00
4.00
B.O.D.j" Min.
7.04
B.O.D.," Min.
4.87
G" +.03" -.02"
4.89
-Lp"
9.65 12.80
JA!L 13.20
L"
+.00"
-.50"
36.00
+Lc" *.06" 11.00
Non-Reducing
Pipe Size, Inches
Nom. I.D.l"
6x6 6.00
Nom. I.D.?"
6.00
B.O.D.j" Min.
7.50
CTD015310
B.O.D.," Min.
7.04
G" +.0033"
.02"
Lp"
7.06 11.20
F" 13.89
La" 14.72
L" +.00" -.50"
36.00
Lc" t.06"
13.67
PREPARED BY:
Notes: 1. Refer to standard pipe machining for main and branch dimensions not shown.
APPROVED by:
R aD
02-10-0023 (P927) 12/76 CONFIDENTIAL DOCUMENT - NOT TO BE: DISTRIBUTED TO UU NAUTHORIZED PERSONNEL
Page 4-14
Karting EuMpla:
COtI*I-TEED *5 DELE. WYE 6,6g, 15/24/3300
Effacing
*" * 2.00" .062"
Pip* Slti, Inches
Non. I.P.l"
3x4 5.60 6x4 8.60 6x3 6.60
Hem. I.Da?"
4.00 4.00 3.00
B.O.D.," +.25"1 B.O.P. "
-.00"
Kin/
<r 030" -.020"
7.06 a.12 8.12
4.87 4.67 5.98
4.89 4.89 6.00
7.63 8.50 8.50
F"
12.25 13.00 13.75
Won-ftednctng
Pipe Six*, Kon, Inches- IJUT
B.O.D.-a"
Non.
+.25"1 B.O.D.j"
i.o.y < -.00"
Min. *
r*
s
4*4 3x1 6x6
6.60 5.60 6.60
4.00 5.00 6.00
5.92 7.06 8.12
4.87 5.98 7.04
11.50 12.75 14.25
6.88 7.63 8.50
9,84 11.16 12,56
Robu 1. Bafar to atandard coupling nachining for uln aachlolng. 1. tafar Co atandard. pipe for nachining dimenrIona not ahovn, 3. |M branch bach a Idea of Min.
4. Branches to bo 180 apart.
L.A."
11.16 12.56 12.56
l"
+.00" -.50"
13.75 15.25 17.00
t" +.00" -.50"
15.25 17.00 17.00
L.C." .06"
9.80 10.70 11.88
T..C." .06" 11.25 11.30 12.40
L.8." 06''
4.93 4.72 4.84
L.B." ,06"
6.38 6.43 5.42
L. D." a06" .06"
4.18 5.05 4.27
11.08 11.95 12.73
t.D." .06"
3.43 3.40 3.51
L.E." 06"
10.33 11.86 13.49
CTD015311
TECHNICAL SPECIFICATIONS
60 WIG FITTING
Pipe Size Inches
Nom. I.D.t"
Non. I.D.,,"
B.O.D.."
+.25" -.00"
61XI4 6x5 6x6
6.6 0 6.60 6.60
h.OO 5.oo 6.00
8.12 8.12 8.12
B.O.D.J," Min.
U.8? 5.98 7.0h
G"
+.03" -.02"
L" +.00" -.50"
F" +.06"
U.89 6.00 7.06
17.00 17.00 17.00
10.9h 10.75 9.37
11.U2 12.00 10. lU
11.88 12.75< 10.77
Lp"
8.60 9.08
9.5k
Note: Refer to Standard Pipe and Coupling for machining dimensions not shown.
CTD015313
TECHNICAL SPECIFICATIONS
CertainTeedEI
CertainTeed Corporation Pipe and Plastics Group
SPECIFICATIONS CLASSIFICATION:
A/C Standard Product Specification
T.C.O. REF. NO.
47
SPECIFICATION NO:
2 Section A
PAGE NO.:
4-17
SUPERSEDES:
February 18, 1977
DATE OF ISSUE:
MAR 5 ^979
DESCRIPTION:
FUJID-TITE A/C Sewer Pipe, Couplings, and Accessories Classes 1500, 2400, 3300, 4000, 5000, 6000 and 7000 Sections A and B
TEE FITTING
aOJ3.2------ I.D.jj--*
8.0X1 <
/> LBi
.. : >: : . i -. ..
l"` ~1
Marking Example:
CERTAIN-TEED TCE
4"S.x4"S. 15/24/3300
Reducing
K" - 2.00" + .062"
Pipe Sire, Inches
Nora. I.D.l"
Nom. I.D.2"
B.O.D.i" +.25" -.00"
5x4 5.60 6x4 6.60 6x5 6.60
4.00 4.00 5.00
7.06 8.12 8.12
Non-Reducing
Pipe Sire,
Inches
' Nom. I.D.i"
4x4 4.60 5x5 5.60 6x6 6.60
Nom. I.D.2"
4.00 5.00 6.00
B.O.D.," +.25" -.00"
5.92 7.06 8.12
B.O.D.," Min.
4.87 4.87 5.98
B.O.D.j" Min.
4.67 5.98 7.04
1" +.00" = -.50"
12.75 13.75 13.75
G" +.030" -.020"
4.89 4.89 6.00
P"
8.77 9.30 9.30
L.C." +.06"
5.97 6.00 6.00
La"
6.375 6.875 6.875
L" +.00" -.50"
11.50 12.75 13.75
F"
8.20 8.77 9.30
C" +.030" -.020"
4.89 6.00 7.06
L.C." .06"
5.90 5.97 6.00
La"
5.75 6.375 6.875
Motet 1. Refer to standard pipe for machining dimension* not sham. 2. Refer to standard coupling for nacblnlng dimensions not shown.
PREPARED BY:
APPROVED BY:
CTD015314
(P927)02-10-0023
12/76 CONFIDENTIAL DOCUMENT - NOT TO BE DlISTRIBUTED TO UUlNAUTHORIZED PERSONNEL
Tee Fitting
Page 4-18
Dimensions
Marking Example:
CERTAINTEED TEE
6"S. x 4"S. 15/24/3300
Pipe Size, Inches
6x4 6x6
Nom. I.D.]"
6.00 6.00
Nom. I.D.9"
4.00 6-. Off
B.O.d:!" Min.
7.04 7.50
B.O.D. " Min.
4.87 7.04
L" +.00" -.50"
36.00 36.00
G" +.03" -.02"
- F"
4.89 7.06
9.50 8.66
Lc" .06"
6.00 5.66
_JA
9.50 8.75
Notes: 1. Refer to standard pipe machining for main and branch dimensions not shown.