Document 82JpwJQN6oDa2LRpQQYwD40Gk
-
Vv
[ ee
7
7
Please replace pages 6 and 7 of your Instruction Manual titled ETHYLENE OXIDE
DECONTAMINATION IN PORTABLE BAG May 1977 Revision with the
attached
JNJTALC000543036
6.11 6.11 6.11
6.12
s
Open the inlet valve to the bag
Be certain that the pressure gauge is isolated by closing the nearest valve
6.13
to that gauge
Place the copper coils into a container of water already heated to 80 C -
10 C.
NOTE Check frequently to assure that the copper tube outlet from the
evaporator to the bag remains warm during transfer This eliminates the possibility of E.O. entering the bag in liquid form
6.14
Open the two valves at the cylinder and release 6kg of gas into the
teflon bag During this feed the pressure should not exceed 1.0 P.S.I.G.
The pressure should be checked frequently during filling since the burst
6.15
strength of the bag is 3.0 P.S.I.G. Record the time when 6 kg has been fed into the bag and then close all
valves and disconnect the pipe at the point nearest to the bag
6.15 6.15 6.15 6.15 6.17 6.17
6.176.17
Let the pressurized bag stand for a minimum of 10 hours
Vent bag into the open air by releasing the zipper
See
Safety
requirements and record the total cycle time
7.0
SAFETY REQUIREMENTS
7.
Ethylene Oxide is a highly toxic irritant which may cause immediate
damage to the eyes and skin upon contact with liquid ETO and to the
respiratory system if high concentration of the gas are inhaled Exposure
to the gas has also been associated with changes in the chromosomes of
human lymphocyte white blood cells Although no adverse term
health effect have been determined some may possibly exist Therefore
& has developed a guideline for occupational exposure to ETO limiting exposure to 1 ppm 8 hour time weighted average and 10 ppm peak which needs to be rigidly followed for all operations where exposures to ETO
occur This guidelicnaen be obtained from Corporate Health and Safety
in New Brunswick by contacting the Director of Industrial Hygiene
Corporate Health and Safety Affairs Tel 201-524-4982
ETC bag operations must be located outdoors and should preferably be
physically separated from the main building Regardless it should be
Located at least 50 feet from any building air intake or opening
JNJTALC000543037
7.3 Entry into the bag sterilizer area must be restricted to authorized
.
.
personnel only 7.4 A face gas mask equipped with ETC canister must be worn by the
operator while gassing the bag and following the sterilization cycle when
the bag is vented and unzipped The bag should then be laid open to allow
the ETO gas to dissipate from the product for 2-3 hours before the
product is handled manually or moved indoors
7.5 Respiratory protection must be used when disconnecting and changing
,
ETO cylinders
7.6 In case of severe exposure a doctor should be summoned To administer
first aid for eyes wash immediately with large quantities of water for at
least five minutes remove contaminated clothing immediately follow other safety precautions specified in the Corporate ETO guideline manual
74 Flammability
The standard E.O. mixtures with halocarbon or CO2 i.e. 88/12 are non-
|
flammable when mixed with any proportions of air However if the E.C.
concentration exceeds 12 by weight then the mixture become
flammable
It is very important therefore that these mixtures be
withdrawn from the cylinders as liquid and that they are then completely
vaporized before entering the E.C. Bag Hence by careful use and
monitoring of the vaporization equipment warm copper tube always
between evaporator and bag the concentration should never exceed the
flammability limit
7.5 Handling and Storage of Cylinders A. Cylinders should be stored upright in a dry ventilated place kept if possible below 20 C.
B. Cylinders must be kept well away from naked flames or red hot
surfaces No part of the cylinder should be subjected to a
temperature higher than 50 C. C. Care must be taken when handling cylinders
A. cylinder barrow or
trolley should be used to move them D. When returning an empty cylinder replace any valve outlet and
protective cap supplied with the cylinder Do not permit air to
enter the cylinder
JNJTALC000543038