The meeting convened at 3:00 p.m.
-
OLD BUSINESS The committee reviewed open items from the meeting of
August 31, 1984 with the following items having been completed or disposed of as indicated:
Item 8-2: Elevator Permit for 1984-85 has been received and posted.
Item 8-6:
Glasses inserts for Scott Air Pak masks are being evaluated for adequacy.
Item 8-19: An overall industrial hygiene evaluation of the DCU is to be made in October.
Item 8-20: This item under consideration and being evaluated.
Item 8-21: Personal H-S monitors are available and can be obtained by contacting foremen of Units or Zones.
Answers to the general questions that were asked by the
Union representatives in the August 31st meeting are as
follows:
.
1. First Aid Training has not started at this time and
will not be scheduled until 1985.
2. No target date has been set for completion of covering exposed asbestos within the plant and it
is an ongoing program. At the present time there are four employes working on this job.
3. Supervision and employes have been instructed not to use any plankings that are not correctly marked as concerns inspection.
4. The off-shift fire company consists of two shift , foremen, one acting as Fire Marshal, the other as
Captain, one Operator from the Boiler House, one
WA-TEX 001484
Joint Healtli^Psafety Committee Minutes
2
August 31, 1984 '
operator from each unit that is not effected and two to three personnel from RP&S, This would constitute a minimum crew of 7. Additional personnel could.come from any Maintenance personnel if in the plant or others working in the plant. There is no Industry standards or rules of thumb on this subject that is known.
5. MSDS Books are available for each unit in Control
Rooms and also foremen have copies and are available to all' employes,"' '
NEW BUSINESS
,,
' Safety Zone II'was inspected by the Union
Representatives with items noted being carried forward as open
items, ,
# A brief general discussion was held by the Committee,
* Meeting adjourned at 3:40 p.m.
WA-TEX 001485
Joint Health sUfafety Committee Minutes
3
August 31, 1984
MO.
LOCATION
DISPOSITION
5-5 (82)
ZONE I
NORTH UNITS
'`
investigate building' -'sum-"to FCCU Hot
Charge Drum to prevent splash back on
south end of drum.
EHE--BM I&T
8-1 FCCU-lnvestigate need for installing
DFB-Invest.
extension straps to extend the ladder
& Recommend
cages on platforms above, ..grade, to prevent
people from falling if they were to lean
back on lower section of ladder where
cage ends.
.
8-3 FCCU-lnvestigate the road base along the
east side of the unit between the FCCU and the Poly. This area appears to be eroding and the pavement sinking.
dfb-Invest. & Recommend
8-4 FCCU-lnvestigate hole in the side of 3B-17 DFB-Invest*
spraying hot condensate across the pad.
& Recommend
9- 1. FCCU-lnvestigate removal or repair of 12
' foot stepladder that was found in bad repair.
DFB-Invest. & Recommend
8-5 Alky-Poly-SRU-Investigate need for
DFB-Invest.
respiratory protection when blowing down & Recommend
instruments. In particular, 16FR-129 on
off shifts. Reported that day shift uses
protection and off-shifts do not.
8-7 Alky No. 1-lnvestigate pile of cement on DFB-lnvest. pad south of acid pumps that is a tripping s Recommend
hazard*
8-8 Alky No. 1-Investigate replacement of
DFB-lnvest.
concrete in slab south of 8E-G7. Tripping & Recommend
hazard.
8-9 Poly Unit-Investigate need for use of gas DFB-lnvest.
mask when swinging a blind on the
& Recommend
depressuring line on the Poly Reactors.
There is only one block valve between the
line and the flare system.
8-10 .
Poly Unit-Investigate a hot condensate
leak in the overhead pipeway north of 5J-GM5A.
DFB-lnvest. & Recommend
WA-TEX 001486
Joint Health^?* Safety Committee Minutes
4
August 31, 1984
NO.
LOCATION
DISPOSITION
ZONE I
8-11
8-12 8-13 8-14 8-15 8-16
*
NORTH UNITS
SRU-investigate if Sulfur TrucJc Drivers are in need of additional training as to safety requirements when loading sulfur. Some drivers not aware of what H2S alarm
indicates.
SRU-investigate a warning system such as lights along road around the SRU to warn
people not to drive around unit in ease H2S alarm sounds.
Poly-Amine Unit-Investigate installation of additional H2S sensors in Amine Units to monitor different wind directions,
Flare Pit-Investigate draining standing water on walkway leading to east stair way into the flare pit.
SOUTH UNITS
DCU-investigate insulation of exposed
steam tracing line on the seal oil
reservoir of K-l C-l for personnel
protection.
'
DCU-Investigate permanent installation of insulation on overhead line of quench overhead accumulator 15-C105. Present insulation loose and falling apart.
DFB-invest. & Recommend
DFB-lnvest. & Recommend
DFB-lnvest. & Recommend
DFB-lnvest. & Recommend
CES-Invest. & Recommend
CES-Invest, & Recommend
8-17 `
8-18
9-2
DCU-lnvestigate replacing bottom straps used for closing doors on elevator. Also noted no state inspection posted in elevator.
CES-Invest, & Recommend
DCU-lnvestigate use of insulation diapers on !8W wedge plugs at third deck of coke drum structure. This type of installation proved to be fire hazard on VPS.
CES-Invest. & Recommend
HTU #2-Investigate size and location of pipe support at LP2.07, Size and location hampers work being done on pump.
CES-Invest. & Recommend
| WA-TEX 001487
j
l
Joint Health s^afety Committee Minutes
5
August 31, 1984
NO.
6-5
9-3 9-4
9-5 9-6
9-7 9-8 9-9 9-10
LOCATION
DISPOSITION
ZONE IX
#2 COOLING TOWER
Investigate chemical building floor drain; drains chemicals, leaks to ground.
'
JLC-Work begins 10/1 under PSP 998. Est.
completion date 11/15.
Investigate restocking supplies in safety GMB-Invest,
box at Cooling Tower.
& Recommend
Investigate altering water station, hose GMB-Invest. storage rack and safety shower arrangement. & Recommend Hose from water station blocks safety shower.
#1 COOLING TOWER
Investigate restocking of supplies in safety box at Cooling Tower.
GMB-Invest. & Recommend
Investigkate deteriorating sealant on electric junction box located south side under stairway.
LQV-Invest, S -Recommend
:
EFFLOENT PLANT
Investigate listing precautionary measures GMB-Invest.
for sulfuric acid on acid tank.
& Recommend
Investigate need for possible replacement GMB-Invest. of grill work at north and south end of the & Recommend
API.
Investigate placement of Scott Air Pak in Lab for emergency use in case of chlorine leak.
GMB-Invest. & Recommend
Investigate restocking supplies in Safety
Equipment Box in chemical mix area of main building.
GMB-Invest. & Recommend
| WA-TEX 001488
Joint Healtn^PSafefcy Committee Minutes
August 31, 1984 *
NO.
LOCATION
DISPOSITION
I&E SHOP
9-11 Investigate eliminating sour gas from coming into shop from DCU tankage.
GMF-Invest. & Recommend
PIPE SHOP
9-12
Investigate replacement of safety latches on chain hoist hooks.
DLB-Invest. & Recommend
STOREHOUSE
9-13
Investigate adequacy of hoist used in
changing Cascade Air Bottles at bottle rack. Difficult to control hoist when lowering bottles.
WHH-Invest. & Recommend
1-2 '
' ZONE III TANK FARM . investigate installing racks for nitrogen, bottles used for purging at sphere area.
GJF-Being worked.