Document 8271k5gr5qBjBw4m1a6yok8GB

No plaster--decorated rigid or build ing board interior finish ( H In.) Plaster (% in.) on metal lath-- stud space faced one side with bright aluminum foil Plaster {% in .) on metal lath* on studding--rock wool fill (3JH) in.*) between studding" Plaster (^4 in .) on metal lath* on studding--flexible insulation ( H >n-) between studding and in contact with sheathing American Society of Heating and Ventilating Engineers Guide, 1937 Table 5. Coefficients of Transmission (U) of Various Types of Frame Construction These coefficients are expressed in Btu Per hour per square foot per degree Fahrenheit difference in temperature between the air on the two sides, and are based on a wind velocity of 15 mph. TYPICAL CONSTRUCTION EXTERIOR FINISH TYPE OF SHEATHING /Tt'P/ j'HEvnuuG.* j`rtfp/v woqp 1 in. Wood4* Wood Siding or Clapboard H in. Rigid Insulation y$ in. Plaster Board Wood Shingles 1 in. Wood4* ^ in. Rigid Insulation* y in. Plaster Board* Chapter 5--Heat Transmission Coefficients and Tables INTERIOR FINISH No Insulation Between Studding 5 e< a 1 I 5 oa J3 1a * e te 3 3 s* c- AB 0.25 . 0.26 -o <3 2 s Ja. ao aC di 3 ^w ao C 0.25 J0c 1 1 .3 = xS wo d 50 D 0.19 a .2 ji .1 1 sf 5| x! 30 5 E 0.15 d 5 ja 8 g d Sj iso- FG 0.11 0.19 Insulation Between Studding H 0.20 I 0.072 J 0.17 0.23 0.24 0.23 0.18 0.14 0.11 0.18 0.19 0:070 0.17 0.31 0.33 0.31 0.22 0.17 0.13 0.23 0.24 0.076 0.20 0.25 0.26 0.25 0.19 0.15 0.11 0.19 0.20 0.072 0.19 0.20 0.19 0.15 0.12 0.10 0.16 0.16 0.066 0.24 0.25 0.24 0.19 0.15 0.11 0.19 0.19 0.071 0.17 0.14 0.17 Stucco 1 in. Wood41 H in- Rigid Insulation H in. Plaster Board 0.30 0.31 0.30 0.22 0.16 0.12 0.22 0.23 0.076 0.27 0.29 0.27 0.20 0.16 0.12 0.21 0.22 0.074 0.40 0.43 0.40 0.26 0.19 0.14 0.28 0.29 0.081 0.20 0.19 0.24 1 in. Wood4 Brick/ Veneer y$ in. Rigid Insulation fftlkininG* yi in. Plaster Board 76 "Computed from factors marked by * in Table 2. These coefficients may also be used with sufficient accuracy for plaster on wood lath or plaster plaster board. "Based on the actual width of 2 by 4-in. studding, namely, 3% in. 118 0.27 0.28 0.27 0.20 0.15 0.12 0.21 0.21 0.074 0.18 0.25 0.26 0.25 0.19 0.15 0.11 0.19 0.20 0.072 0.18 0.35 0.37 0.35 0.24 0.18 0.13 0.25 0.26 0.079 0.22 `Furring strips between wood shingles and sheathing. " /Small air space and mortar between building paper and brick veneer neglected. membrane should be provided between the outer material and the insulation fill to .possible wetting by absorption and a subsequent lowering of efficiency. 119