Document 7qkngLpgobaeB7Kyw53L6QOB

Specialties, Heating Albany, N. Y. Altoona, Pa. AB08LST, N. Y. Atlanta, Ga. Baltimore, Md. Birmingham, Ala. Boston, Mass. Brooklyn. N. Y. Buffalo, N. Y. Canton, Ohio Chicago, 111. Cincinnati, Ohio Clarksburg, W. Va. The Trane Company La Crosse, Wisconsin Cleveland, Ohio Columbus, Ohio Dallas, Texas Davenport, Iowa Dblanco, N. J. Des Moines, Iowa Detroit, Mich. Findlay, Ohio Flint, Mich. Gainesville. Fla. Greensboro, N. C. Harrisburg, Pa. Houbton, Texas Trane Branch Offices Indianapolis, Ind. Jackson, Miss. Juneau, Alaska Kalamazoo, Mich. Kansas City, Mo. La Crosse, Wis. Little Rock, Ark. Los Angeles, Calif. Louisville, Ky. McKeesport, Pa. Memphis, Tenn. Milwaukee, Wis. Missoula, Mont. Newark,'N. J. New Haven, Conn. New Orleans, La. New York, N. Y. Oklahoma City, Okla. Omaha, Nebr. Oshkosh, Wis. Peoria, III. Philadelphia, Pa. Phoenix, Ariz. . Pittsburgh. Pa. Portland, Oregon Portsmouth, Ohio Richmond, Va. Rochester, N. Y. Salt Lake City, Utah San Francisco, Calip. Seattle, Wash. Shreveport, La. St. Paul, Minn. St. Louis. Mo. Syracuse, N. Y. Washington, D. C. Wilkes-Barre, Pa. Mexico, D. F. Trane Bulletins give complete data on Trane Products and will gladly be sent on request TRANE HEATING EQUIPMENT EXTENDED SURFACE HEATING--Bulletin No. 152. Construction. Typical examples. Performance tables. Installation diagrams. . Capacities. COPPER CONVECTORS--Bulletin No. 110 and Data. Complete explanation of instant control and convected heat. Installation details. Roughing-in dimensions. Heating capacities in equivalent direct radiation and Btu. UNIT VENTILATORS--Bulletin No. 65 and Data. Air-O-Lizer for classroom-- Air-O-Vent for large spaces. Explanation of Trane System of Schoolroom Air Con ditioning. Air-O-Lizer and Air-O-Vent control cycles. Auxiliary units. Complete capacities and roughing-in dimensions. UNIT HEATERS--Propeller Models--Cradle Coil and De Luxe Units. Bulletin No. 85. Blower Models--Heat Blowers and Torridor. Bulletin No. 75. Explanation of Floor Line Spread and Cradle Coil. Installation suggestions. Performance data. Capacities (hot water and steam). Roughing-in dimensions. HEATING SPECIALTIES--Complete information on Heating Specialties for every steam or hot water system. Construction. Operation. Capacities. Dimensions. TEMPERATURE CONTROL VALVE--Bulletin. Applications. Operation. Construction. Dimensions. HUMIDIFIER--Bulletin No. 125. Complete capacities for heating and humidi fication. Roughing-in dimensions. PUMPS--Bulletin No. 33. Circulating and Booster Pumps. Condensation Pumps. Capacities. Installation instructions. Dimensions. Construction. TRANE AIR CONDITIONING EQUIPMENT EXTENDED SURFACE COOLING COILS--Direct Expansion Coils Bulletin No. 172 Water Cooling Coils Bulletin No. 182. Types E & C. Typical examples. Per- fnrmati/v nafa xinan panonifioe COMMERCIAL AIR CONDITIONERS--Bulletin and Data. De Luxe Models Large Capacity Models. Office Models. Applications. Capacities. Structural features. Roughing-in dimensions. Selection of units. RESIDENTIAL AIR CONDITIONERS--Five Complete Systems for Heating and Air Conditioning in the Home--Bulletin. Climate Changer for steam or hot water-- Bulletin No. 230. Airite for direct fired oil heating--Bulletin No. 227. Operation. Construction. Capacities. Roughing-in dimensions. PRODUCT COOLERS--Bulletin No. 25. Applications. Capacities. Dimensions. .CONDENSERS--EV Condenser Bulletin No. 42. Construction. Operation. Dimensions. Capacities. EVR Condenser for railroads. Bulletin and Supplementary Manual No. 307R. Operation. Construction. A Complete Line of Heating, Ventilating and Air Conditioning Equipment Extended Surface Heating and Cooling Coils. De Luxe Air Conditioners. Commercial Air Conditioners. Propeller Type Coolers. Evaporative Condensers. Airite. Climate Changer. Copper Convectors. Humidifiers. Propeller Unit Heaters. Blower Unit Heaters. Thermostatic Bellows Traps. Packless Valves. Vent Traps. Boiler Specialties. Float Traps. Temperature Control Valves. 1094 Specialties, Healing WARREN WEBSTER & COMPANY Pioneers of the Vacuum System of Steam Heating it-since1888^ pAjgpP Main Office and Factory: Camden, N. J. Systems of Steam Heating Branches in Over 60 Cities Consult Your Local Phone Directory PRODUCTS AND SERVICES Improved Webster Systems of Steam Heating including Vacuum and Type "R" (vapor). Webster Central Control Systems including HYLO and MODERATOR. Modernization of Obsolete and Faulty Heating Systems. Webster System Equipment in cluding Light-Weight Concealed Ra diation (Gravity Convection Heaters), Radiator Supply Valves, Metering Orifices, Thermostatic Traps, Drip Traps, Heavy Duty Traps, Dirt Strain ers, Dirt Pockets, Boiler Return Traps, Vent Traps, Damper Regulators, Boiler Protectors, Lift Fittings, Ex pansion Joints, Separating Tanks, Steam and Oil Separators, Steam Vacuum Pump Governors, Air Sepa rating and Receiving Tanks, Gages, Water Accumulators. 1 Webster Series "78" and Series "79" Traps for use at process pressures (10 to 125 lb. per sq. in.) an automatic Outdoor Thermostat sup plemented by a manual Variator. The latter is used for quick heating-up, night load, and unusual weather or oc cupancy conditions. Use of Webster Central Control Systems results in (1) increased comfort because over-heating and underheating are minimized and (2) lower fuel or steam costs. IMPROVED WEBSTER SYSTEMS The Improved Webster Systems are low pressure, two-pipe systems of steam circu lation with the addition of accurately-sized metering orifices at radiator supply con nections and, when required, intermediate metering* orifices at points in branch mains. Metering orifices effect even dis tribution of steam to all parts of the heating system and permit the successful application of a centralized control. Im proved Webster Systems are available for vacuum, open return or "vapor" opera tion. The Type " R" System corresponds to the so-called Vapor type. Fig. 1 illustrates a typical arrangement of Boiler Return Trap, Vent Trap, etc., when low pressure boiler is the source of steam. WEBSTER SYSTEM RADIATION Concealed, non-ferrous type for use exclusively with Improved Webster Sys tems. Is unique in that it combines in a single unit, a light-weight heating element of high efficiency with an orificed radiator supply valve, a radiator trap and supply CENTRAL CONTROL SYSTEMS These are patented systems for varying the amount of steam to all radiators ac cording to outside temperature. They provide continuous heat delivery with effec tive fractional filling of radiators. The Hylo Systems may be provided for manual control, or if desired, may be semi-automatic by incorporation of inside thermostat or thermostat and schedule clock. The Moderator Systems employ Fig t. W'ehtier System Hndintion . 1095