Document 7Rwy5XxK86RwQpddjdqjj5LVg

Recommended Procedures for Sampling and Counting Asbestos Fibers Procedures for Hie Evaluation of Occupational Exposures to Airborne Asbestos Joint AIHA-ACGIH Aerosol Hazards. Evaluation Committee Fibrous asbestos has been IDENTIFIED as the causative agent of asbestosis and has been associated with an increased cancer incidence. The American Conference of Governmental Industrial Hy gienists (ACGIH) has established (1974) a Threshold Limit Value (TLV) for asbestos of 5 fibers greater than S micrometers in length per milliliter of air. A TLV footnote specifies the determination shall be made by the membrane filter method at 400 X to 450 X magnification and with phase contrast illumination. These procedures define a standard of sampling and of processing the collected samples in order to evaluate occu pational exposure to asbestos fibers. Sampling Airborne samples of asbestos must be collected on membrane filters which retain at the surface essentially all of the particles in excess of 0.5 /rm in diameter. The filter must be rendered transparent by the mount ing medium. The filter should be packed in a sealed holder which is capable of being readily opened for sampling purposes and of being reseated after the sample has been collected. The filter must be fully exposed during sampling. (Recommended filters and filter holders are listed under Supplies). The filter must be practically dust-free with an average background count of less than 25 Reprint! of (hit article are available for purchase from either the American Industrial Hygiene Association, 66 South Miller Road. Akron. Ohio 44313 or the American Conference of Governmental Industrial Hygienists. P.O. Bos 1937, Cincinnati. Ohio 45201. The com is $1.00 per copy. fibers per square centimeter. At least 2% to 4% of the filters intended for collecting samples should be set aside to determine the background count (See Counting and Cal culations sections). In addition, the filter resistance should not exceed 3 mm of mer cury when filtering air at the rate of 0.3 liters per minute (1pm) per square centimeter of filter. When collecting the sample, care must be taken to prevent dust from falling or from being projected onto the open filter. This may be accomplished by pointing the filter head downward. A guard or shroud should be attached to the filter holder to further protect the open filter from contamination as well as optimize uniform deposition on the filter. Its diameter should be about the same as the holder so that it can be attached tightly to it and it should project at least 114 times the filter diameter in front of it. A protective device is particularly important if the filter head is to rest on contaminated clothing. (See Figure 1.) The filter holder may be stored for a limit of six months once it is resealed. The sample should not be too dense, since samples in which particles overlap must be rejected as uncountable. Similarly, a large enough volume of air should be sampled so that there are sufficient numbers of fibers in each field. Experience indicates that more than 150 particles per field, including non- flbrous background, may interfere with counting the sample. It is desirable that ' there be no more than 10 fibers per field. Two or three samples should be collected at each sampling location. The results should S3 FMSI--0185 FMSI 03123 T 84 ter holder. The shroud may be constructed from a plastic battle by cutting off the neck and drilling a hole in the bottom. To use, push the filter holder through the hole and reach in through the top to remove the holder cap. To remove the holder, re place the cap and push the filter holder forward through the hole. . bo averaged to obtain the fiber concentra tion. Breathing zone samples should reflect the worker's entire normal work day. They must be collected as close to the worker's nose and over as long a time period as possible. Calibrated battery powered per sonal pumps (see Appendix III, Pump Cali bration) are satisfactory air movers. They can be worn by the worker and supported at the belt by means of a clip. The sam pling head, which can be pinned to the col lar, is connected to the pump by flexible tubing. Such pumps can be operated continu ously for about eight hours and recharged overnight. If a 37-mm filter is used to collect the sample, the pump should be adjusted to sam ple between 1 and 2 liters per minute. The volume of air sampled should be adjusted so that an optimum density of dust is col lected on the filter. Since the dust concentra tion is not known before sampling, the op timal sampling period must be determined by trial and error. It is suggested that, unless experience indicates otherwise, the first sam ple should be collected from 20 liters of air, the second from 40 and the third from 80 February, 197S liters. If a filler other than 37-mm is used, the volume of air sampled should be altered in direct proportion to the open filter area. Samples collected during short periods of exposure should be collected at a high flow rate and if necessary, for the entire exposure period. In all cases the count should be adjusted with regard to time, so that the exposure is expressed as an 8-hour timeweighted average exposure. For compliance evaluations with short term exposures, 37mm filters samples should be collected for 15 minutes at a minimum of 2 1pm. i j I Sample Preparation A solution one-to-one by volume of di methyl phthalate and diethyl oxylate in which has been dissolved 50 milligrams of membrane filter material per milliliter of solution is the preferred counting medium. The chemicals used to prepare the medium should be examined microscopically to be certain that they are dust free. The fiber material to be dissolved should not be marked and should have a maximum back ground count of 25 fibers per square centi meter of filter. The counting medium may be stored in a wide-mouthed Wheaton Bal sam bottle and should be applied with a glass rod. The counting medium has a re fractive index of 1.461 at 25 C. The me dium should be made in small quantities I since it has a 6 month shelf life. Asbestos fibers are counted on wedge shaped sections cut from the filter. The wedge should be reasonably sized so that it can be mounted on a 25 x 75 mm (1x3 inch) glass microscope slide. The slide should be cleaned of dust before it is used. A drop or two of counting medium is placed on the slide and the filter wedge is placed dust side up on top of the medium. The wedge is covered by a No. 1 Vi coverslip. Care must be taken while lowering the cover- slip to avoid trapping air under it. Air bub bles may be forced out by exerting slight pressure on the cover slip with a pencil eraser. Extreme care must be taken to avoid FMSI 03124 American Industrial l/yyicnc Association Journal 85 i too much pressure, since this causes distor- trast substage condenser, a 4 mm "high dry" tion and stretching in the fdter. phase-contrast objective (40 X to 45 X) and The wedge is usually cleared within 15 a I0X eyepiece is used to count Ihc sample. minutes; however, a residual background It should hitvc either a prc-focuscd built-in granularity may be noted. This will disap illuminator supplied with an iris diaphragm pear within a day. Counts must be com or be lighted by a separate bright illuminator- pleted within two days since there is a rial mirror combination. If a separate illu tendency for fiber migration and crystal minator is used it should be equipped with a 1 growth. The prepared medium should be oondensing lens, iris diaphragm, and means j checked periodically for a background count. for adjusting both the illuminator level and (See Counting and Calculations sections.) the distance between the condensing lens An alternate medium may be used when and the bulb. Zoom microscopes may be the samples must be counted immediately, used for counting asbestos fibers, provided i It is prepared in the same manner as the that the total magnification is within the ! preferred viscous medium, except that the 400-450 X range. j added membrane filter is omitted. Since this The illuminator should be equipped with medium is much less viscous it should be an adjustable constant voltage transformer. stored in narrow-mouthed bottles. This mc- Both the microscope condenser and stage dium is applied with a glass dropper -after require close adjustment and both should be the filter wedge has been placed dust side up rack and pinion mounted. The stage must on the slide. However, a drop should be move along two perpendicular axes in a i placed on the slide adjacent to but not on horizontal plane, while the condenser must ' top of each corner of the wedge. This mc move up and down in a vertical plane. ; dium acts very rapidly and the No. lVi Lighting must be adjusted for optimum bal 1 coverglass should be lowered within a min- ance. The Kohler method of illumination is | ute. Slides made up with this "alternate recommended. (See Appendix I for pro medium" are ready for counting within five cedures required to establish Kohler illu i minutes and the count must be completed minator.) j within two hours after preparation, The counting field is defined by a reticle i Filters which have been used to collect mounted at the level of the field-limiting di j samples and which have been resealed in a aphragm in the 10 X eyepiece. The Porton | holder should be removed only in a clean reticle (Figure 2) is recommended. However, ' environment. They should not be held with any reticle which contains markings which, the fingers. They may be held with tweezers in addition to. outlining an area of about and cut with either a scalpel or scissors. 0.005 square millimeters, as determined by Bottles containing media must be tightly closed except during use. All bottles, tools used for handling and cutting filters, and oooU.J0HO O iff It If Ij containers used for storing tools must be thoroughly cleaned and dried. Tweezers, scissors, scalpels, etc. should be set aside for this purpose exclusively. Although slides and coverslips are purchased pre-clcancd, they should be wiped lightly with clean lens tisuc to remove traces of dust. Do not at tempt to reuse slides or coverslips. Microscope A microscope equipped with a phase con Figure 2. Porton reticle. * .T,, - -n T-.-i^yin- --* - -i-i. xnir.<iuui..:--..-T. ."i; , % FMSI 03125 r 86 the combination of eyepiece and objective, and which defines linear distances that may serve as measuring aids, is satisfactory. The reticle must be' calibrated prior to use and recalibrated each time it is removed from the microscope eyepiece or when the micro scope tube length or interpupillary distance is changed. Zoom microscopes must be re calibrated each time the zoom position is changed. (See Appendix II for recommended calibration procedures.) Counting A fiber is defined as a particle whose length is at least three times greater than its diameter. All fibers longer than 5 fan within the area delineated by the reticle, or which enter it from cither of two adjacent sides, arc counted. Fibers entering the area from either of the other two sides, /.<?., those not arbitrarily chosen as "counting" sides are not counted, nor fibers in excess of 5 /im in diameter. Touching fibers, i.e., one of whose ends touch another fiber regardless of the resulting angle, arc considered as one. Fibers that cross each other arc counted in dividually. Fibers that pass through the de lineated area arc counted provided that they cross at least one of the arbitrarily chosen "counting" sides. (See Figure 3.) Fiber length should be determined by measuring against standards such as a circle or a space defined by markings on the cali brated reticle. If the fiber is curved or wavy the total length should be estimated by meas uring along the curve. Once sufficient ex perience has been gained in judging length, only fibers whose length or diameter arc in question need be measured. A routine for choosing counting fields mast be selected so that fields arc not count ed more than once and that a representative fraction of the total filler area is viewed. A convenient procedure which may be used is to select a scries of microscope viewing fields along a radial line extending from the apex of the filter to the outer edge of the sample wedge. The viewing fields must be February, 1975 chosen without preference to a particular area and should be approximately equally spaced along the line. The first field should be located a Iktlc bit in from the point at which matter is deposited on the filter. If the required number of viewing fields can not be located on a single radial line, addi tional lines parallel to the first should be chosen. Preferably 100 fibers should be counted but all the fibers in 20 fields should be counted even if there are more than 100 fibers. The counting may be terminated after 100 fields have been searched even if 100 Fibers have not been counted. Calculations The concentration of asbestos fibers in air can be expressed as: Asbestos Cone. = Fibers x R Fields x Vol ' Figure 3. Illustration ot fiber counting with a Porton reticle. The top and left side of the large box have been chosen as "counting sides". Circle 6 is S /im in diameter. (A) Fiber A crosses the top of the box and is counted, therefore. One end of Fiber A, touches Fiber A and thus is considered as part of it and is not counted separately. (B) Fi ber B is a bundle containing many spikes. It passes through the box crossing bottom and top. It is counted as one fiber. (C) Fiber C passes through the box but it crosses the right side and bottom. It is not counted. (D) Fiber D is entirely within the box and crosses over Fiber A. It is not part of Fiber A. therefore it is counted as a separate fiber. (E) Fiber E is less than 5 pin in length. It is not count ed. FMSI 03126 American Industrial Hygiene Association Journal where: Fibers = total number of fibers counted Fields = total number of fields counted r= filtration area area of a counting field Vol = sampling rate (1pm) x time (min) x 10s = sample volume in ml of air Since both the filtration area on the mem brane filter and the area of the counting field are normally constant, the ratio of areas, R, is constant for the given conditions. To illustrate: Air is sampled at 1 liter/ minute for 50 minutes on a 3 7-mm mem brane filter (filtration area 855 mm2). A total of 60 fibers each longer than 5 ^m are counted in 100 fields each 0.003 mm2 in area: _ _ 855 mm2 3 x 10~3 ram2 2.8 x 105 and Asbestos Cone. = 2.8 x IQ5 x 60 Fibers______ 100 Fields x ^ X ^ m* x 50 min nun . Since the precision of this met^Hkis limited, the averaged results of the several samples should be reported to the nearest significant figure. Appendix I Recommended Procedure for Establishing Kohler Illumination The microscope is set on a level surface at a convenient height and in such position that sighting through the eyepieces is possible without undue strain or discomfort. The illuminator is placed directly in front of and aligned with the microscope. If the illuminator is equipped with a coil filament bulb, its iris should be ten inches from the mirror. If a ribbon filament bulb is used, the front of the filter holder should be at least seven inches from the mirror. Only the plane surface of the mirror should be used. All filters should be removed from 87 the system except that if desired, neutral density filters may be used to reduce the light intensity. If the microscope is equipped with a built-in illuminator, proper illuminator positioning has already been accomplished and need not be of further concern. Fix a mounted sample on the stage and recheck the alignment. Raise the substage condenser until it nearly touches the bottom of the slide. Turn on the illuminator and use the tilt controls to direct the light to the center of the mirror. Tilt the mirror, direct ing the beam upward into the stage con denser. Close the microscope substage iris and the illuminator iris. Use the illuminator focus control to focus the image of the fila ment on the 'bottom of the substage iris. The reflection of the iris may be viewed in the mirror by leaning over the microscope. After adjusting the illuminator condenser so that there is a sharp image of the filament on the substage iris, open it about halfway. Recheck proper position of the mirror and then put the objective in place and focus sharply on the sample. It may be necessary to open the substage iris during focusing. After the sample is in focus, fully close the iris. Readjust the condenser height so that the edge of the iris leaves are in sharp focus and there is a bright spot within the iris. Readjust the mirror to obtain maximum brightness. If the color around the iris is not uniform, recheck the illuminator tilt and focus. If the color is uniform and maximum brightness has been achieved, open the field iris until the blades just pass out of the field of view. The proper phase stop is inserted or ro tated into place in the substage condenser. The phase objective is rotated into place. The eyepiece i$ replaced with the phase ring centering telescope. The telescope is ad justed for sighting. The location of the phase ring is observed through the telescope. It may be adjusted by using the two rotating shafts provided with the phase condenser. When the ring is centered it appears as a bright annular ring mounted on top of a FMSI 03127 88 grey ring. The center is black. There should be no overlap of the bright ring into the center. When the phase stop is centered the telescope is removed and the eyepiece is re placed. The microscope is now ready for use. Appendix 11 Recommended Procedures for Calibrating Reticle The reticle must be slightly smaller in diameter than the eyepiece in which it is to be used. It fits into the tube and is held in place at the eyepiece focal point by spring pressure. The focal point is marked by an internal collar which prevents the reticle from passing further into the tube. Some manufacturers locate the focal point just below the collar while others prefer a point immediately above it. Thus it may be nec essary to insert the reticle between the lens and the collar on one microscope and below the collar on another. In either case the projected image of the reticle on the field must be clear and sharp. The reticle must project a constant count ing area as well as provide markings for sizing. Many types of reticles are satisfac tory. The Porton reticle illustrated in Figure 2 is recommended. .It outlines a large rec tangle that fits easily within the field of vision. The rectangle is divided into two equal squares. The left square is further divided into six rectangles. Each side of each square has a length equal to 100 L, then the large rectangle is 200 L units long and the small ones 50 L units long and 33VS L units high. To the left of the left square is a scale which divides the side into 20 equal increments of 5 L units each. The right square is divided horizontally in thirds corresponding to the small rectangles and vertically into a series of increasing spaces. The distance between each vertical line and the center of the large rectangle corresponds to the diameter of a circle. Circles of sizes 1 through 9 arc located above and below the large rectangle. The diameter of each circle February, 1975 is related in terms of L units of length in accordance with the formula: D = L yftF where D is the diameter of the circle or the width of the space and N is the number of the circle, or space. The unit L is determined by measurement. A stage micrometer is the primary ruler. Any one or more of the definitive linear di mensions may be measured. If the length of the large rectangle is measured then L equals I/200th of that value. If the stage micrometer is marked in hun dredths of millimeters the value of L is in hundredths of millimeters. If the left square is used as a counting area, its area is equal to . (100x0.01 L)2 mm* The filtering area of a 37-mm filter is 855 mm2 and thus If other areas arc used as counting fields or other sized filters are used, the value of R must be calculated for the individual con dition. It is wise to prepare a chart showing each linear dimension and area for ready reference while counting. Appendix III Pump Calibration Personal sampling pumps should be cali brated for flowrate frequently. They may be calibrated against a primary meter such as a spirometer or against a previously calibrat ed secondary standard such as a wet gas meter or dry gas meter. The train should be arranged so that the pump is operating against the same resistance it would normally operate against, and that the calibrating meter is at atmospheric pressure. Figure 4 illustrates the recommended arrangement. Air flow through the filter may be limited by both restricting the air flow to the pump as well as by admitting secondary air into FMSI03128 American Industrial Hygiene Association Journal nrr5R Figure 4. Diagram of set-up for calibration of pump. the puinp. Most personal pumps arc con structed with adjustment valves that permit both actions. Calibration should be repeated after each 24 to 36 hours of pump use. If the pump has not been used for a prolonged period of time it should be recalibrated. Temperature and attitude corrections should be made. Personal sampling pumps should not be used to such an extent that the batteries are allowed to run down below normal operating voltage. Since battery life varies, it is wise to occasionally check the life of the battery by allowing the pump to run down to the first indicated change in voltage under timed simulated conditions. Supplies Filters and Filter Holders Millipore Corp.* Field Monitor filter hold ers preloaded with 37-mm Type AA filters, either white plain {catalog #MAWP037A0) or gridded (#MAWG037A0) are recom mended. These are sold with a guaranteed average particle background and can be used without additional background checks. It is less expensive to purchase unloaded field monitors (#MABG037A0) to be loaded with plain or gridded filters pur chased separately in packages of 100 (# AAWP03700, and AAWG03700). The field monitor can then be reloaded after each use. However, it is necessary to care fully dean the empty monitor and to check ihc background count on filters in the re loaded monitor. 89 Type AA fillers can be used in any di ameter in any non-leaking open-type filler holder, as long as proper adjustment is made in the calculations for the change in filtering area, and periodic background checks arc made. Membrane filters of other types and man ufacturers cannot be recommended at this time, cither because they do not become optically clear in the mounting medium or because of excessive particle background. Personal Battery Powered Sampling Pumps (1) Casella1' MK II or MK 111 Personal Sampler (2) MSAr Monitaire Sampler, Model G. (3) Bendixd VM 22 or Micronair Per sonal Sampler or C-l 15. Microscopes: Phase Equipped . (a) microscope body with a fine focus accuracy of 0.006 mm; (b) 10 X eyepiece; (c) mechanical stage; (d) illuminator (preferably built in and having provisions for adjusting light intensity); (e) 40X to 45 X (0.65 N.A. at least) positive (bright field) phase-contrast objective; (f) annual ring condenser diaphragm (corresponding to the objective); and (g) phase ring centering telescope. (Note: Most manufacturers sell a basic body unit and built-in illumination system as a unit. Phase-contrast accessories can us ually be purchased as a kit consisting of 10 X, 40 X and 90 X phase objectives, a phase condenser containing appropriate an nular ring diaphragms, a phase ring center ing telescope, and a green filter. It is to the microscopist's advantage to purchase the kit.) A list of manufacturers of phase-contrast microscopes1' anil reticles1 is given below to aid in selecting a proper instrument. * MUlipore Corp., Bedford, Mau. 07130. * Willson Products Div,, P.O. Box 622, Reading, Pennn. 19603. C. F, Casella A Co. Ltd., Regent House, Britannia 90 Walk, London, N.l, England. e Mine Safety Appliance Co., 201 Braddock Avc., Pitta, burgh, Petma. I520K. 11 Bcndix--NEI. P.O. Box 590, Fall River, Mast. 02722. 9 Buusch und Lomb, Scientific Instrument Diviiion. 72624 Bauach Street, RocheIter. N.Y. 14602. Olympua Microscopei, Micro Optica Company, 28165 Greenfield, Southfield, Mich. 48075. American Optical Corporation, Reichert Products, Buf falo, N.Y. 14215. February, 1975 E. Leltz Inc., Rocklcigh, N.J. 07647. Nikon Inc., Inurnment Dlvlaltm, Garden City, N.Y. 11550. Uniiron Instrument Company, Microscope Sales Divi sion, 66 Needham Street, Newton Highland, Maas. 02161. Can Zeiss, 444 Fifth Avenue. New York. N.Y. 10018. 1 Edmund Scientific Co.. 701 Edaorp Building, Barring ton. NJ. 07007. BGI, Incorporated, SB Guinan St., Waltham, Mass. 02154. Joint AI11A-ACG1H Aerosol Hazards Evaluation Committee AIHA ACGIH Morton Lippmann, Ph.D., Chairman J. LeRoy Balzcr, Ph.D. Douglas K. Craig, Ph.D. Graham W. Gibbs, Ph.D. William C. Janes William H. Krebs, Ph.D. Carl A. Mangold ' Eric B. Sansone, Ph.D. Marvin Tillery Thomas F. Tomb Russell W, VanHouten Wesley R. VanPelt, Ph.D. Donald 1.. Webster Howard E. Ayer George Carson, Ph.D. Harry J. Eltinger Murray Jacobson Geoffrey Knight Jeremiah R. Lynch G. Major Owen Moss Milton Scheinbaum Glen W. Sutton Industrial Hygiene Training in Israel Medical and engineering students at Tel Aviv University will be ob ligated in the future to undertake training in occupational safety, hygiene and health to inspire them with an awareness of their obligations for the maintenance of the health of the worker and for the prevention of ill effects from work on man. . This has been made possible by the establishment in 1974 by the Faculties of Medicine and Engineering of the University, in collaboration with the Ministry of Labor, of the National Insurance Institute and the Workers Health Insurance (Kupat-Holim) of a Center for Occupational Safety, Hygiene and Health, with four major departments--Physiology of Work and Rehabilitation, Occupational Toxicology, Occupational Hygiene, and Safety Engineering. It comes to fill long-standing gaps in the promo tion of safety and health of the working population in Israel and the absence of training facilities for specialists in these fields. The new Center will immediately provide refresher courses for physicians and nurses, but curricula for the training of Occupational Toxicologists, Hygienists and Physiologists arc in preparation. Ultimately the Occupa tional Health Physician will also be trained at the Center. Due to lack of suitable personnel in the country the Center is seeking to recruit specialists from abroad. FMSI 03130