Document 7RrROLrjpkgbGo5VenVd7n6zE
O QG Laboratories'
I S4. ly
Analytical Report
PETER TYRRELL UNITED WATER CITY OF ORANGE CHESTNUT STREET PLANT AT 632 BEACH STREET ORANGE, NJ 07050
Account No: C00927, UNITED WATER CITY OF ORANGE
Project No: C00927,
*
Sample Number L25WS60^r *
Sample Description
CHESTNUT ST POE TREATED TP001001 Received Temp: 38 F Iced (Y/N): Y
Parameter PFOA
Method
Sample Number LW?
Sample Description
ORANGE PARK POE TREATED TP002008 Received Temp: 38 F Iced (Y/N): Y
Parameter PFOA
Method
Sample Description GIST PL POE TREATED TP003010
MCL MCL
Regarding:
PETER TYRRELL UNITED WATER CITY OF ORANGE CHESTNUT STREET PLANT AT 632 BEACH STREET ORANGE, NJ 07050
P.O. No: PWStad*EK."fr71r7e01%
Samp. Date/Time/Temp 01/15/08 11:45am NA F
Inv. No: 945295
Sampled by Customer Sampled
Result ATTACHED
Samp. Date/Time/Temp 01/15/08 08:30am NA F
RLs Test Date,Time
Sampled by Customer Sampled
Result ATTACHED
Samp. Date/Time/Temp 01/15/08 09:30am NA F
RLs Test Date,Time
Sampled by Customer Sampled
- A result of "ND" indicates the concentration of the analyte tested was either not detected or below the RLs. - Definitions: ND=not detected; NEG=negative; P0S=positive; COL=colonies; RLs=laboratory reporting limits; L/A=lab accident; TNTC=too numerous to count; NL=No Permit Limits.
- A result marked with "DRY" indicates that the result was calculated and reported on a dry weight basis. - All analysis, except field tests are conducted in Southampton, PA unless otherwise identified. - The test"pH lab"is analyzed upon receipt at the laboratory, the result will not be suitable for regulatory purposes. - Actual times of analysis for parameters reported <24 hours are available upon request. All testing is conducted within the required holding time unless otherwise noted.
- QC NELAP ID's-.PA 09 00131 ,NJ PA166.FL E87954.NY 11223,CT PH-0768,DE PA-018,KY 90228,MD 206,EPA PA00018.Bioassay:PA 09-03574,NJ PA034.FL E87953,KS E10373,SC 89020001.
- QC STATE ID's:Wind Gap.NJ PA001.PA 48-01334;E RUTHERFORD NJ02015;Vineland NJ06005; Reading PA 06-03543. - MCL= is the recommended EPA "Maximum Contaminant Level" for a parameter. PLs=customer specific permit limits. Regulatory authorities are assessing substantial fines for testing omissions. Please track your sample collections and results on a weekly, monthly, or quarterly basis to ensure compliance. QC's internet program 'LIVE ACCESS' will provide you with
real-time access to collection dates and results. Please contact Customer Service for further information on acquiring LIVE ACCESS.
Page 1 of 2
Serial Number: 931169
Thom as J. Hines, P re sid ent
1205 Industrial Blvd., P.O. Box 514, Southampton, PA 18966-0514 Phone: 215-355-3900 Fax: 215-355-7231 www.qclahoratories.com
DEP2-SDWB-000136
QC Laboratories
Analytical Report
Account No: C00927, UNITED WATER CITY OF ORANGE Project No: C00927, UNITED WATER CITY OF ORANGE
Received Temp: 38 F Iced (Y/N): Y
Parameter PFOA
Method
P.0. No: PWSID No: 0717001
W1A C C O ,,
4S&
o#02708/1
pm
Inv. No: 945295
MCL Result ATTACHED
RLs Test Date.Time
- A result of "ND" indicates the concentration of the analyte tested was either not detected or below the RLs. - Definitions: ND=not detected; NEG=negative; POS=positive; COL=colonies; RLs=laboratory reporting limits; L/A=lab accident; TNTC=too numerous to count; N U N o Permit Limits.
- A result marked with "DRY" indicates that the result was calculated and reported on a dry weight basis.
- All analysis, except field tests are conducted in Southampton, PA unless otherwise identified. - The tesr'pH lab"is analyzed upon receipt at the laboratory, the result will not be suitable for regulatory purposes.
- Actual times of analysis for parameters reported <24 hours are available upon request. All testing is conducted within the required holding time unless otherwise noted.
- QC NELAP ID's:PA 09-00131.NJ PAI66.FL E87954.NY 11223,CT PH-0768,DE PA-018.KY 90228,MD 206,EPA PA00018.Bioassay:PA 09-03574,NJ PA034,FL E87953.KS E10373.SC 89020001.
- QC STATE ID's:Wind Gap,NJ PA001.PA 48-01334;E RUTHERFORD NJ02015;Vineland NJ06005; Reading PA 06-03543. - MCL= is the recommended EPA "Maximum Contaminant Level" for a parameter. PLs=customer specific permit limits.
Regulatory authorities are assessing substantial fines for testing omissions. Please track your sample collections and results on a weekly, monthly, or quarterly basis to ensure compliance. QC's internet program 'LIVE ACCESS' will provide you with
real-time access to collection dates and results. Please contact Customer Service for further information on acquiring LIVE ACCESS.
Page 2 of 2
Serial Number: 931169
Th om as J. Hines, Presid e nt
DEP2-SDWB-000137
ANALYTICAL REPORT
PFOA/PFOS Analysis
Lot#: D8A170291
Nicki Smith QC Laboratories, Inc. 1205 Industrial Highway Southampton, PA 18966
TestAmerica Denver
Michelle A. Johnston Project Manager February 4, 2008
L 3 S Q S ( oD
4955 Yarrow Street Arvada, CO 80002 tel 303.736.0100 fax 303.431.7171 www.testamericainc.com
DEP2-SDWB-000138
Table Of Contents
Standard Deliverables
Report Contents
Standard Deliverables
The Coyer Letter and the Report Cover page are considered integral parts o f this Standard Deliverable package. This report is incomplete unless all pages indicated in this Table o f Contents are included.
T able of Contents Case Narrative Executive Summary - Detection Highlights Methods Summary Method/Analyst Summary Lot Sample Summary Analytical Results QC Data Association Summary QC Evaluation and/or Data Reports Chain-of-Cnstody
Total Number of Pages
TestAmerica
i
DEP2-SDWB-000139
Case Narrative
D8A170291
TestAmerica Denver utilizes USEPA approved methods in all analytical work. The samples presented in this report were analyzed for the parameters listed on the methods summary page in accordance with the methods indicated. Dilution factors and footnotes are provided on each datasheet to assist in the interpretation of the results.
The results relate only to the samples in this report and meet all requirements of NELAC. All data have been reviewed for compliance with the laboratory QA/QC plan and have found to be compliant with laboratory protocols with any exceptions noted below.
Please note that Non-Detect (ND) results have been evaluated down to the Method Detection Limit (MDL) and should be considered ND at the MDL. Unless otherwise noted, results for solids have been dry weight corrected.
This report shall not be reproduced except in full, without the written approval of the laboratory.
Sample Arrival and Receipt The following report contains the analytical results for three samples received 1/17/08, according to documented sample acceptance procedures. The samples were received in good condition at a temperature of 3.1C. No anomalies were encountered during sample receipt.
Standards Analytical standards were prepared using the acid form of the compound perfluorooctanoic acid (PFOA). PFOS is a commercial prepared and certified solution.
Perfluoro-n-[1,2,3,4-'3C4]octanoic acid was introduced at the extraction step and was used as an internal standard for quantitation of PFOA. Perfluoro-1-[1,2,3,4-13C4]octanatesulfonate was introduced at the extraction step and was used as an internal standard for quantitation of PFOS.
Sample Extraction and Analysis The sample presented in this report was analyzed for the target analyte by TestAmerica Denver's SOP DEN-LC-0012A.
For water samples a 250 mL aliquot of each sample is acidified with 1 mL of 6N HCI solution and it is extracted using solid phase extraction technique with methanol conditioned C18 cartridges. Each sample is spiked with the internal standard, prior to extraction. After the sample is passed through the cartridge, the analytes are eluted with 4 mL of methanol. The final volume is brought to 5 mL using methanol and the extract is analyzed by LC/MS/MS.
Method QC Samples The Method Blank is processed reagent water spiked with surrogate and prepared with each batch of 20 samples of the same matrix. The method blank was non-detect at the reporting limit.
Each batch is prepared with a Laboratory Control Sample (LCS). The recoveries of two concentration levels of Laboratory Control Samples were within control limits.
TestAmerica
2
DEP2-SDWB-000140
Analytical Comments The LCS percent recovery associated with QC batch 8017446 was outside the QC control limits, biased high, for PFOS. This is an indicator that data may be biased high.
The PFOS sample duplicate analysis for QC batch 8017446 showed an RPD result of 200. It can be noted that the RPD was calculated based on values below the reporting limit, and as such, could not be reliably calculated.
No other anomalies were observed.
TestAmerica
3
DEP2-SDWB-000141
EXECUTIVE SUMMARY - Detection Highlights
D8A170291
PARAMETER
1.2512560-1 01/15/08 11:45 001
PFOA PFOS
L2512560-2 01/15/08 08:30 002
PFOA PFOS
L2512560-3 01/15/08 09:30 003
PFOA PFOS
RESULT
REPORTING
LIMIT
UNITS
ANALYTICAL METHOD
0.037 0.013
0.010 0.010
ug/L ug/L
DEN -LC-0012 DEN -LC-0012
0.061 0.011
0.010 0.010
ug/L ug/L
0.065 0.018
0.010 0.010
ug/L ug/L
D E N ,,-LC-0012 DEN -LC-0012
DEN -LC-0012 DEN -LC-0012
I
TestAmerica
4
DEP2-SDWB-000142
METHODS SUMMARY
D8A170291
ANALYTICAL P A R A M E T E R ______________________________ _________________ M E T H O D _______
LC/MS/MS, PFOA
DEN -LC-0012
References:
DEN Severn Trent Laboratores, Denver, Facility Standard Operating Procedure.
PREPARATION METHOD
TestAmerica
DEP2-SDWB-000143
METHOD / ANALYST SUMMARY
D8A170291
ANALYTICAL METHOD
ANALYST
DEN -LC-0012
Jaqueline Bonnett
References:
DEN Severn Trent Laboratores, Denver, Facility Standard Operating Procedure.
ANALYST ID
003601
TestAmerica
DEP2-SDWB-000144
SAMPLE SUMMARY
D8A170291
wo # SAMPLE# CLIENT SAMPLE ID
KFPQV 001 L2512560-1 KFPQ3 002 L2512560-2 KFPQ4 003 L2 512560-3
NOTB(S) : _______ _____________________ _ _ ______________________________
- The analytical results of the samples listed above are presented on the following pages. - All calculations are performed before rounding to avoid ruund-off errors in calculated results. Results noted as "N D ' were not detected at or above (he stated limit. - This report must not be reproduced, except in full, without the written approval of the laboratory. - Results for the following parameters arc never reported on a dry weight basis: color, corrosivity, density, flashpoint, ignitability. layers, odor,
paint filter test. pH, porosity pressure, reactivity, redox potential, specific gravity, spot tests, solids, solubility, temperature, viscosity, and weight.
SAMPLED SAMP
DATE
TIME
01/15/08 11:45 01/15/08 08:30 01/15/08 09:30
TestAmeriea
DEP2-SDWB-000145
QC Laboratories
Client Sample ID: L2512560-1
HPLC
Lot-Sample # -Date Sampled__ Prep Date..... Prep Batch # __ Dilution Factor
D 8 A 1 7 0 2 9 1 - 0 0 1 Work Order # _..
01/15/08 11:45 Date Received..
01/17/08
Analysis Date..
8017446
Analysis Time..
1
Method........
KFPQV1AA 01/17/08 01/21/08 21:22
DEN -LC-0012
Matrix
PARAMETER PFOA
PFOS
R E S U L T ______ _ _ _ 0.037 0.013
REPORTING LIMIT 0.010 0.010
UNITS ug/L ug/L
SURROGATE 13C4 PFOA 13C4 PFOS
PERCENT R E C O V E R Y ________ 109 71
RECOVERY LIMITS (50 - 200) (50 - 200)
: WATER
TestAmerica
DEP2-SDWB-000146
QC Laboratories
Client Sample ID: L2512560-2
HPLC
Lot-Sanple #... Date Sampled... Prep Date..... Prep Batch #... Dilution Factor
D 8 A 1 7 0 2 9 1 - 0 0 2 Work Order #... : K F P Q 3 1 A A
01/15/08 08:30 Date Received..: 01/17/08
01/17/08
Analysis Date..: 01/21/08
8017446
Analysis Time.. : 21:39
1
Method........ : D E N -LC-0012
Matrix
PARAMETER PFOA PROS
RESDLT 0.061 0.011
REPORTING
_ LIMIT
UNITS
0.010
ug/L
0.010
ug/L
SURROGATE 13C 4 PFOA 13C4 PFOS
PERCENT R E C OV E R Y________ 106 65
RECOVERY LIMITS (50 - 200) (50 - 200)
: WATER
TestAmerica
DEP2-SDWB-000147
QC Laboratories
Client Sample ID: L2512560-3
HPLC
-r..
Lot-Sample # . . . : D 8 A 1 7 0 2 9 1 - 0 0 3 Work Order # .. .: K F P Q 4 1 A A
Date Sampled__ : 01/15/08 09:30. Date Received. .: 01/17/08
Prep Date..... : 01/17/08
Analysis Date. .: 01/21/08
Prep Batch # ...: 8017446
Analysis Time. .: 21:55
Dilution Factor: 1
Method....... .: D E N -LC-00
Matrix.
PARAMETER PFOA PROS
RESULT 0.065 0.018
REPORTING LIMIT 0.010
0.010
UNITS
ug/i<
ug/L
SURROGATE 13C4 PFOA 13C4 PFOS
PERCENT RECOVERY 102 65
RECOVERY LIMITS (50 - 200) (50 - 200)
WATER
TestAmerica
10 DEP2-SDWB-000148
QC DATA ASSOCIATION SUMMARY
D8A170291
SAMPLE# 001 002 003
Sample Preparation and Analysis Control Numbers
MATRIX WATER WATER WATER
ANALYTICAL METHOD
DEN -LC-0012
DEN -LC-0012
DEN -LC-0012
LEACH BATCH #
PREP BATCH #
8017446
8017446
8017446
MS RUN# 8017259 8017259 8017259
TestAmerica
11 DEP2-SDWB-000149
METHOD BLANK REPORT
HPLC
Client Lot #...: D8A170291 MB Lot-Sample #: R8A170000-446
Analysis Date..: 01/21/08 Dilution Factor: 1
Work Order #...: KFP5Q1AA
Prep Date......: 01/17/08 Prep Batch #...: 8017446
Matrix........ : WATER Analysis Time..: 19:30
PARAMETER
PFOA
PFOS
RESULT ND ND
REPORTING
LIMIT
UNITS
0.010
ug/L
0.010
ug/L
SURROGATE 13C4 PFOA 13C4 PFOS
PERCENT RECOVERY 96 68
RECOVERY LIMITS (50 - 200) (50 - 200)
NOTB(S) :_____________________________________
Calculations are performed before rounding to avoid round-off errors in calculated results.
METHOD DEN -LC-0012 DEN -LC-0012
TestAmerica
12 DEP2-SDWB-000150
LABORATORY CONTROL SAMPLE EVALUATION REPORT
HPLC
Client Lot
D8A170291
Work Order #...: KFP5Q1AC
LCS Lot-Sample#: R8A170000-446
Prep Date..... : 01/17/08
Analysis Date..: 01/21/08
Prep Batch
: 8017446
Analysis Time..: 19:46
Dilution Factor: 1
Matrix.
PARAMETER PFOA PFOS
PERCENT RECOVERY 91 91
RECOVERY LIMITS (70 - 130) (39 - 120)
METHOD DEN -LC-0012 DEN -LC-0012
SURROGATE 13C4 PFOA 13C4 PFOS
PERCENT RECOVERY 94 71
RECOVERY LIMITS (50 - 200) (50 - 200)
MOTB(S) :_____________________ _____ __________
Calculations are performed before rounding to avoid round-off errors in calculated results. Bold print denotes control parameters
WATER
TestAmerica
13
DEP2-SDWB-000151
LABORATORY CONTROL SAMPLE DATA REPORT
HPLC
Client Lot # -- D 8A 1702 91
Work Order #.
KFP5Q1AC
LCS Lot-Sample# R 8 A 1 7 0 0 0 0 4 4 6
Prep Date..... 0 1 / 1 7 / 0 8
Analysis Date..: 01/21/08
Prep Batch #... 8 0 1 7 4 4 6
Analysis Time..: 19:46
Dilution Factor: 1
Matrix.
WATER
PARAMETER PFQA PFOS
S P IK E AMOUNT 0.200 0.200
MEASURED AMOUNT 0.182 0.182
U N IT S ug/L ug/L
PERCENT RECOVERY 91 91
METHOD DEN -LC-0012 DEN -LC-0012
SURROGATE 13C4 PFOA 13C4 PFOS
PERCENT RECOVERY 94 71
NOTE(S): Calculations are performed before rounding to avoid round-off errors in calculated results.
Bold print denotes control parameters
RECOVERY LIM ITS (50 - 200) (50 - 200)
TestAmerica
14
DEP2-SDWB-000152
LABORATORY CONTROL SAMPLE EVALUATION REPORT
HPLC
Client Lot #- -.: D8A170291
Work Order
KFP5Q1AD
LCS Lot-Sample#: R8A170000-446
Prep Date..... : 01/17/08
Analysis Date..: 01/21/08
Prep Batch # -- : 8017446
Analysis Time..: 20:02
Dilution Factor: 1
Matrix
PARAMETER PFQA PFOS
PERCENT RECOVERY 117
128 a
RECOVERY LIMITS (70 - 130) (39 - 120)
METHOD DEN -LC-0012 DEN -LC-0012
SURROGATE 13C4 PFOA 13C4 PFOS
PERCENT RECOVERY 102 73
NOTE(S): ___________________________________
Calculations are performed before rounding to avoid round-off errors in calculated result1. Bold print denotes control parameters a Spiked analyte recovery is outside staled control limits.
RECOVERY LIMITS (50 - 200) (50 - 200)
WATER
TestAmerica
15
DEP2-SDWB-000153
LABORATORY CONTROL SAMPLE DATA REPORT
IIPLC
Client Lot # -- : D8A170291
Work Order #...
LCS Lot-Sample#: R8A170000-446
Prep Date..... : 01/17/08
Analysis Date..
Prep Batch #...: 8017446
Analysis Time..
Dilution Factor: 1
KFP5Q1AD
01/21/08
20:02
Matrix........ : WATER
PARAMETER PFOA PFOS
SPIKE AMOUNT 0.0200 0.0200
MEASURED AMOUNT 0.0234 0.0257 a
UNITS ug/L ug/L
PERCENT RECOVERY 117 128
METHOD______ DEN -LC-0012 DEN -LC-0012
SURROGATE 13C4 PFOA 13C4 PFOS
PERCENT RECOVERY 102 73
RECOVERY LIMITS (50 - 200) (50 - 200)
NOTB(S) :____________________ ________________
Calculations are performed before rounding to avoid round-off errors in calculated results. Bold print denotes control parameters a Spiked analyte recovery is outside stated control limits.
TestAmerica
16 DEP2-SDWB-000154
MATRIX SPIKE SAMPLE EVALUATION REPORT
HPLC
Lot-Sample # __ MS Lot-Sample # Date Sampled... Prep Date..... Prep Batch #... Dilation Factor
D8A170291
Work Order #...
D8A170279-001
0 1 / 16/08 07:05 Date Received..
01/17/08
Analysis Date..
8017446
1
KFPNT1AC
01/17/08 01/21/08
Matrix
PARAMETER PFOA PFOS
PERCENT RECOVERY 105
94
RECOVERY LIMITS (70 - 13D) (39 - 12D)
SURROGATE 13C4 PFOA 13C4 PFOS
PERCENT RECOVERY 103 69
NOTB(S): ______ ____________________________
Calculations are performed before rounding to avoid round-off errors in calculated results. Bold print denotes control parameters
METHOD________ DEN -LC-0012 DEN -LC-0012
RECOVERY LIMITS (50 - 200) (50 - 200)
: WATER
stAmerica
1'
DEP2-SDWB-000155
MATRIX SPIKE SAMPLE DATA REPORT
HPLC
Lot-Sample # __ : D 8 A 1 7 0 2 9 1
Work Order #.
MS Lot-Sample #: D 8 A 1 7 0 2 7 9 - 0 0 1
Date Sampled...: 0 1 / 1 6 / 0 8 0 7 : 0 5 Date Received
Prep D a t e ..... : 0 1 / 1 7 / 0 8
Analysis Date
Prep Batch #...: 8 0 1 7 4 4 6
Dilution Factor: 1
KFPNT1AC
0 1 /1 7 /0 8 0 1 /2 1 /0 8
Matrix........ : WATER
PARAMETER PFOA PROS
SAMPLE S P IK E MEASRD AMOUNT AMT AMOUNT 0.0060 0.200 0.215 HD 0.200 0.188
U N IT S ug/L
ug/L
SURROGATE 13C4 PFOA 13C4 PFOS
PERCENT RECOVERY 103 69
HOTB(S) :_____________________________________ Calculations are performed before rounding to avoid round-offerrors in calculated results. Bold print denotes control parameters
PERCENT RECOVERY 105 94
METHOD DEH -LC-0012 DEM -LC-0012
RECOVERY LIM ITS (50 - 200) (50 - 200)
TestA rtverica
18 DEP2-SDWB-000156
DEP2-SDWB-000157
STL
'f QC Laboratories'
1205 Industrial Blvd. Southampton, PA 18966-0514
Phone: 215-355-3900 Fax: 215-355-7231
CHAIN OF CUSTODY
Page l of '
Bill to/Rsport lo: (if different)
Client/Acot. No. Address
c 4 j U- yL-rv-L.
Sampling Site Address: (if different)
Lab LIMS No: 3JS
3 r L ^ !huqL
: .-v
wyT
City/State/ZIp Phone/Fax
P.O. No,
-------------------------- -------------------- ---------- --
I B PROJECT !,!*'?* F IE L D ID
M
- /L j L s ~ ! - S ~ C
ijL ^ t - tr i r b - s
-----------------
Collection
;G C
R 0 M atrix
Date
; Military Time
AM BP
Code
tfog / / v n | `Mo? f 3
`/rfo t 3 D
T)U
Number ol Containers
T o ta l
C C-
I
H
C
V s
H
N
N '1
03
:,
n A
H; C
Un0
Bi cT
_L
i
I J _ j i-- i _--_-I1
rt
_ Temp contro'
rt>
P f r l PU i
1
3/
M A TR IX C O D E S
DW: DRINKING WATER GW: GROUND WATER WW: WASTEWATER SO: SOIL SL: SLUDGE OIL: OIL SOL: NON SOIL SOLID Ml: MISCELLANEOUS
o
CM
riera pn, lemp u o r r j, DO, Cl2,
o
a. Li ce
rr i
'; I
_ j
qI
Verbal/fax data due: Hardcopy due:
/
:-----------------
n
V/
/ Standard + QC NJ Reduced Disk
Sig:
Please call tor pricing and availability on rush (<14-21 day) turnaround and on all but standard format.
SAMPLE CUSTODY EXCHANGES MUST BE DOCUMENTED BELOW. USE FULL LEGAL SIGNATURE, DATE AND MILITARY TIME (24 HOUR CLOCK, I.E. 8AM IS 0800, 4 PM IS 1600)
RELINQUISHED BYSAMPLER
DATE
TIME RECEIVED BY
DATE
TIME
DELIVERY METHOD: QCCOURIER CLIENT Custody Seal Number
J___^
f_____________
RajfellISHED BY/A
j j / DAT / .
RELINQUISHED BY
'itn"t-- ( M*9 r *r *i----- T # 3 b
0 DATE
TIME
1 RECEIVED BY /)
fi
R F Q o V n R Y .. ^
RELINQUISHED BY
DATE
TIME
received by
DATE
57pM
DATE
TIME
TIME 0 4 tl< TIME
UPS & FEDEX OTHER COMMENTS:
c2.
44
RELINQUISHED BY 5'
DATE
TIME RECEIVED SY 5
DATE
TIME Hazardous: yes / no
For example to aid completion, see reverse side.
to u R 0)
I
tUn <D