MEMORANDUM
TO:
Mr. C. R. Walbridge
May 13, 1971
LOUISIANA STATE AIR CONTROL COMMISSION QUESTIONNAIRE
The attached questionnaire has been filled out with the best knowledge that we presently have- Problem areas that are highlighted are:
1) Unsaturated hydrocarbons - 1,245 tons/year
2) Chlorinated hydrocarbons - 2,372 tons/year
3) Ammonia
- 445511 tons/year
The items under 6D, page 6, have been checked out with the production department and they feel that the jobs as listed will proceed.
In conversations with the Commission's people they are looking for improvement and want to be able to report such- However, the extensive data that we are providing them leaves us vulnerable for many demands and large capital expenditures to correct them. Except for the vent condensers at the vinyl plant, most of the other changes listed are normal maintenance items or apparatus to get rid of an irritating problem. There are many major dust and fume losses that are not directly associated with a stack that we have not listed except in a general manner on page 4.
The attached copy of the letter from Mr. John Trygg is selfexplanatory.
AJL:ew
Attach.
cc: Mr. P. N. Shellenberger Mr. R. E. Mumford Mr. 0. J. Parr
P. B. Cornell, Manager Baton Rouge North Works
C-639 (6-631 (?). PTO, IN U.S-A.
ASI-PR 0004212
ANDREW HEDMEG, M.D., M.P.H., Chawmam fM. T. HACKETT, vie* I RLES J. PASQUA W .M. GARRETT, M.D.
LOUISIANA AIR CONTROL COMMISSION
Louisiana State Office Building P.O. Box 60630
NEW ORLEANS 70160
DAVE L. PEARCE EVERETT JACOB JOHN E. TRYGG, tcchwcal sicait
C k, t i V E o BACON ROUGE
WORKS
API? 29 71
Dear Sir:
It Is requested that you complete the enclose return It to our office at your earliest convenience. We would like to reel eve a reply within thirty days of your receipt of this letter.
The Louisiana Air Control Commission, created by Act 259 of the 1964 Legislature, has been charged with maintaining the purity of the air of our State. The Commission has been given certain specific duties including the collection and dissemi nation of information on air control.
The Information collected will be held strictly confidential according to Commission policy. The Commission plans to continu this policy unless prevented from doing so by State or Federal legislation or legal action. In general, this information will be used developing the implementation plan for achieving and maintaining pure air for Louisiana.
I realize that some questions may be difficult to answer. Give us the best information you can and if a question is not applicable, mark N.A.
If there are questions, either call or write us. Your cooperation is appreciated.
Very truly yours
Enel sure
ASI"PR 0004213
LOUISIANA STATE AIR CONTROlA'MMI S$ ION LOUISIANA STATE OFFICE B^.JING
P. 0. Box 60630
EMISSION INVENTORY QUESTIONNAIRE
New Orleans, La. 70160
Page I of 6
To: Allied Chemical Corporation___ Industrial Chemicals Division
-2ZL
(P. 0. Box No.)
(Street Adaress)
Ba ton Rou^e (City or Town)
EBR La. 70821
(Parish)
(Zip)
PLEASE CORRECT IF NAME OR ADDRESS IS INCORRECT
AUTHORITY: In accordance wixn the provisions of R.S. 40:2201 e+. seq.. The Louisiana Air Control Commission has directed the Technical Secretary to make a survey of Air Pollution in Louisiana and to report the results to the Commission.
INSTRUCTION: (Please Read Carefully)
File a separate report for each of you establishments physically located in
. Louisiana.
2 Use accurate estimates when records ar not avaiIable.
3. Principal means the major portion of u half or more.
4a. Answer All Questions. If certain ques are not appI i < :ap|e to your activity, p indicate NONE or NOT APPLICABLE.
b. Attach descriptions in cases where qus is not applicable.
5. IF OTHER is marked, specify in a I cas use additional sheets if necessary.
.6 The policy of The Commission has been
keep all information received in this questionnaire CONFIDENTIAL. The Commi plans to continue this policy unless c vented to do so by State or Federal leaislation or leaal action.
I tern I
A. Days per week normally in operation (check all That apply):
f.ctivities
l.{x]Monday 2.0Tuesdav 3.0 Wednesday 4. fiTlthursday
5.|X[Friday
6.(xjsaturday 7. X Sunday
B. Days per year normally in operation:
C. Peak production season:
J5_ --, Days
I .0Year round 2. [J Summer D. Shifts normally operated:
3.0Fall
l.[x]Evening (4pm-l2pm, 3pm-1 I pm,' etc.)
4.0Winter 5.0Spring
2.0 Day (8am-4pm, 7am-3pm, etc.) 3.^x1 Night (I2pm-8am, llpm-7am, e
E. Total number of employees at this establishment: (check range)
Less than 5
2. 5.-49
3. 50-99
4.100-249
250-449
6.0450-749 7.0750-999 8.0cver 1,000
F. Type of Operation (Include brief summary of operations under ITEM 7, REMARKS!
1*0Chemical
4.0Mtning , 7.0Manufacturing IO.0Lumber 4 allied proc
2.0Petroieum 5.0Foundry 8.0Disposal'
ll.0Metals 4 allied proc
3.0Food, etc.
6.0Machine 9.0Paper 4 allied l2.0Other (Name) products ASI-PR 0004214
EMISSION INVENTORY QUESTIONNAIRE
STATE OF LOUIS 1AN/W AIR CONTROL COMMISSlW
Page 2 of 6
Item I Cont'd)
G. Raw Materials Used (Chemical name if possible or apllicable)
Materials
Amount per year
Sodium Chloric le ("Variable Calcium Carbor iate Due to
Coke
Production)
Ammonia
Ethvlene
Units
Form (1 iquid, gas or solid)
Liquid Solid Solid Gas
G3 S
How stored
How trans: or shipoec
Tanks Storage Pile Storage Pile
Tank Cars
PiDeliir Belts Belts
Pipelin
None______________ Pinelin
H. Intermediate Products (Chemical name if possible or applicable)
Materials
Ethvlene Dichloride
Chlorine
Amount per year Uni ts
(Variable-due to oroduction)
Form (liquid, qas or solid) Liquid
How stored Tanks Tanks
How trans or shidds
PiDelin barges PiDelin
I. Principal Finished Products (Chemical names if possible or applicable)
Materials
Amount per year
1) Sodium Carbonate
(Variable-due to Sales)
2) Vinvl Choride 3) Sodium Hydrox ide
Units
Form (liquid, How stored
qas or solid)
Solid
Warehouse
Liquid Liquid
Tanks Tanks
How trans or shioDe
Belts, e le ~crew& Hr
Conveyo'
Pipes K ' Cars Pipes, c-Barges
J. Ownership: 1.0 Private 2. | | Municipal 3. Q State 4.0 FederaI
5. 0Corporation 6.0Partnership 7.[3<|other Ind. Development Board
Item 2
FUEL CONSUMP TION
A.
Report Quanti ties of fuels consumed last year
B.
COMPLETE THE FOLLOWING TARLE WITH LAST YCARTs imfqp^ATION
FUEL
OUANTITY
UNITS
Coal used for heat & power
Coal used for production Light Distillate fuel oil.
Nos. 1-4 (Heat & Power) Light distil late fuel oils.
Nos. 1-4 (Production)
None None
None None
Short tons Ga 1 lorls
CUA! % su 1 fur weight
% su1fu weight
ASI-PR 00 04215 l
EMISSION INVENTORY QUESTIONNAIRE
STATE OF LOUISIANA AIR CONTROL COMM I SSI Oil
L+em 2
FUEL
QUANTITY
ont'd)
Residual or Heavy oils
PLEASE
Nos. 5-6 (Heat & Power)
None
NOTE UNITS OF MEASURE
Residual or Heavy oils. Nos. 5-6 (Production)
None
TO BE USED
0. Gas-natural, manufactured or
mixed (Heat & Power)
15,867,000,000
Gas-natural, manufactured or
mixed (Production)
E. Others - Specify kind and use
.1.
2
3
UNITS Gal Ions
DUAL IT
% sulfur h weight
PPM Meta Is
0.5 opm & sulfur b'
Cubic Feet
weight
I tern 3
REFUSE COLLEC TION AND DISPOSAL
A. Amount of combustible refuse disposed of Der year: I.| j Mere 365 Tons or vo I u m e (No. 2 8 & capacity Average 3V yds of waste containers)
B. Form or type of refuse; (wood, rubber, paper, etc.) All types.
ii --- ........ ..
--i
1'
mii^
1
C. Principal methods of refuse collection: l.j__| Not Add Iicab Is
--
2.D City pickup 3.QRrivate pickup 4. Disposal on premises
5* Oother (Soecify) D. If private pickup, name of contractor and address:
E. Principal Methods of Refuse Disposal: I.QNot Applicable
2.0Sanitary Landfill
3.n Open Dump
4. 1 11ncineratfon
5. I 1 Compost! nq
6. QOpen Burning
7.Q Other____________
F. Method of Incineration:
I. Qn/A
2.Qsingle Chamber Incinerator 3.QGas Fired inciner
4.n^ultiple Chamber Incinerator 5.Q Boiler 6. Other ______________
G. Incinerator used:
.__. N/A
Manu facturer:_________________________________________________________________________
Model :________ ________________________ __
Years in operation:
Pollution Abatement Facilities_________
Incinerator Capacity! Pounds per hour
Hours of operation per week
ASI-PR 0004216
MISSION INVENTORY OUESTIONNAI RE
STATE OF LOUISIANA AIR CONTROL COMMISSION
Page 4 of 6
2m 4
A. Particulate Matter and
Approximate None
Aerosols (exclude products #/HR Tons/Yr
of combustion
EMISSIONS
1. Carbonaceous
Particle si ze
Distribution (mirrnn range)
Present but Unable to Estimate
2. Minera1 Solids
3. Organic Particles
4. Other
5. 6.
R. Organic Gases or Vapors (exclude products of combustion)
Ibs/hr
Approximate (on stream)
ft3/hr
Tons/br Yr
None
I. Hydrocarbons (specify' a) VCM Process Vent (See Table I attached) b)
I I
2. Halooenated (specify) a) VCM Process Vent b) c)
3. Oxygenated (specify). a) b) c)
4. Other (specify)
(See Table I attached) None
Inorganic Gases (include products of combustion (indicate if calculated from fuel)
Approximate /HR
I. Sulfur Dioxide (SO2)
0.15
2, Hydrogen Sulfide (HgS)
3. Halogens (specify) a) b)
c)
Tons/Yr
Present but None Unable to Estima'i
0.7 (Nat. Ga 5
4. Other (specify)
Hydrogen fold plant) (Also see Table II attache
'125
550 ASI-PR 0004217
, '
EMISSION INVENTORY QUESTIONNAIRE
STATE OF LOUISIANA AIR CONTROL COMMISSION
Page 5 Of 6
em T '
EMISSION
STACK
A. N A M E or
STACK
Description
INFOR-
of Sources
MAT ION
Lime Kilns
Kiln ;-Dust Collector N
USE ,,
Dust Collector C
ADDI- Dust Collector S
TIONAL
Lime Slaker(MLT)
SHEETS
Vaoors
IF NECES- .dime (MLT) Snails
SARY
Soda Column Vent
Identi
fication Cone. Rate Temp.
Number PPM
(cfs) F
A1 to A13 A14
A1S A16
rablell 25 No Dat 3 -
No Da t 1 No Dat 3 -
400 -
-
-
A17 to A21 Water 7apor A22 to A23 Wa ter 7anor
Exit Felocity Ft./Sec.
18 -
Diam. Feet
1.33 3.00" 1.33 1.67
2.50 1.00
Elev. Above Grade
98 98 98 98
Can b< Same 1e Yes C:
Ye?
7*
105 50
(LCL)
B24 to B27
Filter Vacuum
(LVFLR)
328 to B31
NHo Absorber(LAB) B32 to B33
L.A. Dryers
B34 to BS9
Bag Dust Coll. S.A .B60 to B63
Table [I 73 70
52
tf 65 80 rr 3 70 tr 725 860
47 16
5
(No vi sable em i s s: ons)
1.33
1.33 0.50 7-00 1.00
177
122 28
17 0 170
** 77 7'
f
Old Power House
C64 to C70 Tablel r 555 300
Gas Turbine House D71 to D74 ft 4850 400
7 .0.00 96 8.00
100 60
(Continued-Next page)
B. Stack Use: (indicate stack number from above) l*P)Not Applicable 2. All others Process Emissions 5`.34-59; 64-70;71-74 Fuel Combustion Product 4.
Combined
Item 6
A.
AIR
POLLUTION CONTROL INFOR MATION
Air Pollution Control Units in use:
1. P None
2.PSett Iing Chamber 3. | Baffles 4. PElectrostatic
Precipitator 5. I jMultiple Cyclones 6. [xjcioth Filters 7. 1 Udsorption
16.[ |Other
(indicate efficiency)
Vapor Recovery System Direct Fired Afterburner Other Powered Inertial
Separator 11. ^Catalytic Afterburner
12,1 iDemister 13.pjscrubber 14. QCyclone 15. | ]Type Emission Monitor or
Control System____
B. Do you have an established program of preventive or operational maintenance on your Air Pollution Control Equipment?
I.Qn/A
2.{3ys
3,Qno 4. If Yes, Describe on separate sheet.
It is part of the normal preventative maintenance program for the plant.
ASI-PR 0004218
EMISSION INVENTORY QUESTIONNAIRE
STATE OF LOUISIANA AIR CONTROL COMMISSION
Page 5 df 6 (Ct
^P"rem 5
EMISSION
A. N A M E or
Identi
Exit
STACK
Description
fication Cone. Rate Temp. Felocity
INFOR
of Sources
Number PPM
(cfs) F
Ft./Sec.
MATION
Raff Dust Coll-P&L E75 " D.A. F76 to F79
(Vo
vi: sable
emissi on) 'ff "
USE Dense Ash RGS
F8D
(Water vaoor
)
ADDI TIONAL
Ducon RGS
F81 ( "
S.Clp Sect.-HpVent: ; G82 to G90 9S^+
TT
0.37 110
) 7.5
SHEETS
"
IF NECES TT
" Salt Scrub. G9l
t* TT
IT
G92
CNo da ca (No da :a
) )
SARY
N.C12 Sect.-HpVent! ; H93 to [95 (Water vaoor
)
" " Mastic Pots f 19 6
"(Disco: itinue d use
" Tr Lead Furn. H97
(Combu: st.sas es-lit tie lead
" " Tinning Furi i H98
and smoke ) (Combu: 3t. ga ses-li ttle tin
" " Acid dio
H99
and HC1) (Combu 3t . '-IB ses-Str all amt.
VCM orocess Vinvl Furnaces
Ho a: id HC1 )
J100
Table [ 117 115
J1.01 to ,m > Table Cl 36 800
84 19
Di am. Feet 2.13 2,13 2.33 3 . no
1.50 1.33 3. no 1.07
2750"
0.83
1.50 1.33 1.67
STACK
El v. Can b< Above Samp 11 Grade Yes or
170 Yes
19 7
?
169 TT
21)5 ff
25 60 M 5 2 TT 40 TT 30 TT
30 TT
30 t* 30 TT 165 TT 50 TT
B. Stack Use: (in dlcate stack number from above)
I.ONot Appllc able
2. All others
Process Emissions
3`. J 101
Fuel Combustion Product 4. H97 to H98
Combliled
Item 6
A. Air Pollution Control Units In use: (Indicate efficiency)
AIR
POLLUTION CONTROL INFOR MATION
1. None 2. Settling Chamber 3. __Baffles 4. __Electrostatic
Prec I p I tator 5. [^Multiple Cyclones 6. Qcioth Filters 7. 1 [Adsorption
16. n Other
8. T_ Vapor Recovery System
^Direct Fired Afterburn r
JOther Powered Inertial Separator
11. IZ ZCatalytic Afterburner ^ r^Demister
j"Zscrubber 14,Q ^Cyclone
15. C^Type Emission Monitor or Control System
B. Do you have an established program of preventive or operational maintenance on your Air Pollution Control Equipment?
I< Qn/A
2. PI Yes
3.Qno 4. If Yes, Describe on separate sheet.
ASI-PR 0004219
. *
EMISSION INVENTORY QUESTIONNAIRE
STATE OF LOUISIANA W AtR CONTROL COMMISSION
Page 6 of 6
am 6
C. Approximately how much money have you soent on Air Pollution Control Equ inner.-
^Tcont'd)
and operation in the past 10 years or in the
Years the plant has been
1n operation?
ClNone
Equipment $
1,083,000
Operations
1,552,000
Combined S 2,635,000
0. On a separate sheet list air pollution abatement measures which are or otherwise incomplete. What is the projected reduction in emissions after completion (tons/year reduction)? (Include type and level of emissions for spec? fic years.)
Item 7 REMARKS
Please supply a simplified flow diagram or block diagram of plant or plants on a separate sheet. Type or print pertinent information. Include brief summary of process or operations.
Item 8
PER SONNEL
List plant personnel responsible for Air Control. (To be contacted for visits and communication)
A. Name: Frank P. Turk
Title Supervisor Exits & Effluents
Telephone Mo.
356-3341
B. Name: A. Y. T,aVine '
Title SuDerintendent-Ouality Control Telephone Mo. 356-3341
C, Marne: P. B. Cornell Title Plant Manager Telephone Mo. 356-3341
Name of responsible member of operation
Date
Paul B. Cornell
May 25, 1971
Title of responsible member listed above and address and telephone Mo.
Manager-Baton Rouge North Works
(Phone-356-3341)
Industrial Chemicals Division, Allied Chemical Corp.
P.0. Box 271 Baton Rouge,La
Print or Type name of person preparing report,
Frank P. Turk
Title of above person Supervisor-Exits & Effluents
Telephone No. 356-3341
Area Code 504
ASI-PR 0004220
TABLE I VCM Process Vent
Addenda-Page 1
1) n2 2) ch4
3) 2 4) C02 5) ^2^4 6) 1-2 C2H4C12 7) CO 8) 1-2 C-jH^Clp 9) h2o 10) chci3 11) c4h5ci
12) c2h5ci 13) C2H6 14) c2hci2
% bv Volume
82.1 7.9 4.6 3.3 1.0 0.4 0.2 0.2 0.1 0.1 0.04 0.-03 0.005 0.0009
100.0
Lbs per Hour
23,150 1,128 1,480 1,460 284 418 48 166 25 146 39 23 3.84 1.25
. 28,372
Cu.Ft. per Hour 347,000
33,600 19,400 13,900
4,260 1,770
715 704 580 519 184 153
21 4
422,807
Tons per Year 101,500
4,940 6, 480 6,390 1,245 1,830
210 727 110 639 171 101
16.8 5.5
124,365
Stack Diameter Stack Height Vent Gas Temperature
Vent Gas Flow Vent Exit Velocity
= 16" ** 1651 = 115 F = 117.4 Cu.Ft./Sec. = 84 Ft/Sec.
* 1) Nitrogen 2) Methane 3) Oxygen 4) Carbon Dioxide 5) Ethylene 6) 1,2 Ethylene Dichloride
7) Carbon Monoxide
8) 1,1 Ethylene Dichloride 9) Water 10) Chloroform 11) Chloroprene 12) Ethyl chloride 13) Ethane 14) Trichloroethylene
ASI-PR 0004221
TABLE II
Addenda-page 2
Inorganic Gases Including Products of Combustion
Identification
Tons per year
N2
co2 CO
02
Lime Kilns A1 to A13
Soda Column Vent (LCL) B24 to B27
Vacuum Filter (LVFLR) B28 to B31
Ammonia Absorber (LAB) B32 to B33
Soda Ash Dryers (SHT) B34 to B59
Old Power House C64 to C70
Gas Turbine Power House D71 to D74
Lead Melting Furnace H97
Tinning Furnace H98
Vinyl Furnaces J101 to J112
125,436 133,744
322,749
5,121
198,500
62,230
2,870
65
968,000 158,500
1,770,000 336,000
10,007,424 491,424
(No data --
uStd
147,500
28,950
1,273
485
3,750
9,940
59,850
885
64,100
50,600
2,041,080
2,330
nh3 H2 --
341 103 -
7- 129,600 - 275,000 - 409,968
---------------) _______ - 21,660
ASI-PR 0004222
Item 6D fPage 6~)
Addenda-Page 3
1) Design and install dust collecting systems on soda ash loadings into trucks and rail cars. The completion of these systems will probably be spread over the next five (5) years. The quantity of present dust loss is unknown.
2) Renovate and improve dust systems on kilns lime dischargers and conveyors. Action has been initiated and should be completed within a year. The present lime dust loss is unknown.
3) Plans call for purchase and installation of three improved bag dust collector systems to replace the ones in Nos. 1, 3 and 4 elevator towers. This is designed primarily to reduce present maintenance costs, but will also reduce dustiness. The replacement will be about one dust collector per year.
4) Four bag dust systems are to be replaced in the dense ash operating systems. Conditions will be similar to those in item 3 above.
5) Design and install a scrubber for lead and organic fumes from the cell construction furnaces at the chlorine caustic north section. Expect completion in 1972.
6) Provide chlorine recovery stripper on chlorine gas cooling tower condensate now going to sewer at chlorine-caustic north.
7) Provide vent condensers to reduce chlorinated hydrocarbons going to atmosphere.
ASI~PR 0004223
A / T5 A i3 dbiS' -Pago 2
Q, p % f 7f )
, /* r .{Mens'-1
A S I PR 0 0 0 4 2 2 5"
fK . r.-j >
C* i --> ///?, .,
7 a'y-, Abt&iit
98.99%,
//> 5
1
V-C.
ScAV/3%fL
CAXUUP
- ->
C/t 7-/>
~A cAa <-------
JH>]
<r^ e^/os 7~&
A'e''J7*'/7Lt7/>rj<yAS T'PWi'Ji^
_
<"/* 4" <1 /P/rV'Z' ^ /QUEp/e#
C- s-,' ' ot
*
o ;
,-L I
r/.
<CA/ OK/P/C M0A/O/.1 /X/^
9.9<Qo/D ICA/ECie/A/P 7~0
Area r/i/P'Z Ptfp s-ror^A C
ASI-PR 0004226
U_____
Fu rfffca
SR/rJC
STaFAf^S
3---
p%(ObUfJC7o\A/R
pvXC- S/'Ilt F''o/Vi
--UvtJFtLTR<?D TFtFtr
sroxfi&e
' '!' '
'. K/irtO*t
vfwATr>>1~r.
~7\
//% Ftforn C iflLS
r
(
7-0 paufS 7 S' PS/4- ^
//ypfaSiTAj
-->
Pel. AoP/Tfo/J -------------------------- >5 yC^ /V/ ^*'<*' 7~/20l_
---------------------- To i/cr*i
/<oo ps/4-
.V________
. cpaipkcsscr
&/NP4 FFSO To <r cT <FCTS
P/7 - PFFFotC. S' C
3z.S~G-pt-
V PfvjS f/FFO r> -'//y
j i i
i
pp/a/f ro CTS-F
V ypFrjF-FA/ F'P'&sr/ . F'FFl
ASI-PR 0004227
WtrtH Cunobn. i"cf 1 < f ` W V7')*
ASI-PR 0004228
Item 7 (page 6) Continued
Stacks G82 to H99
G82 to G90:
This is the old electrolytic caustic chlorine operation. It consists of 19 electrical half banks of cells. Each bank contains 52 cells and has one Hg vent stack common to each cell of the bank. Only 18 half banks are in operation at any particular time. The electrolytic products are chlorine gas which is liquified, Hj gas which is vented and NaOH in brine solution which is further processed.
G91 to G92:
The above NaOH in brine solution is evaporated to drop out the salt which is recovered as pure dry salt by drying in a direct fired rotary dryer. The G91 stack is on the scrubber of the exit gases from the dryer. The G92 stack is on the scrubber of the exit air
from the pneumatic conveying of the dryed salt.
H93 to H95:
These are hydrogen vent stacks on the new and larger electrolytic chlorine-caustic operation. The Hp gas from this operation is normally recovered as fuel to the Boiler house. The stacks are for emergency use.
H96 to H99:
The new cells requiie a bed of poured lead for electrical contact with the graphite anodes. A mastic is used to insulate this lead from electrical contact with the brine anolyte. After the anodes are depleted, the lead and mastic are recovered for reuse. Due to recent improvement, the mastic pots are now electrically heated, whereby practically no fumes go to stack G96. The recovered lead containing some mastic (also new lead) is direct fired for melting and reuse. The gases go to H97 which also picks up vent from a copper bar buffing station. All copper connecting bars are- buffed, dipped In acid and in flux (K99) and in a tinning vat (H98).
ASI-PR 0004229