Document 7RqEQ5dnm8NdKvaXz5vrJXgRB

I MEMORANDUM TO: Mr. C. R. Walbridge May 13, 1971 LOUISIANA STATE AIR CONTROL COMMISSION QUESTIONNAIRE The attached questionnaire has been filled out with the best knowledge that we presently have- Problem areas that are highlighted are: 1) Unsaturated hydrocarbons - 1,245 tons/year 2) Chlorinated hydrocarbons - 2,372 tons/year 3) Ammonia - 445511 tons/year The items under 6D, page 6, have been checked out with the production department and they feel that the jobs as listed will proceed. In conversations with the Commission's people they are looking for improvement and want to be able to report such- However, the extensive data that we are providing them leaves us vulnerable for many demands and large capital expenditures to correct them. Except for the vent condensers at the vinyl plant, most of the other changes listed are normal maintenance items or apparatus to get rid of an irritating problem. There are many major dust and fume losses that are not directly associated with a stack that we have not listed except in a general manner on page 4. The attached copy of the letter from Mr. John Trygg is selfexplanatory. AJL:ew Attach. cc: Mr. P. N. Shellenberger Mr. R. E. Mumford Mr. 0. J. Parr P. B. Cornell, Manager Baton Rouge North Works C-639 (6-631 (?). PTO, IN U.S-A. ASI-PR 0004212 ANDREW HEDMEG, M.D., M.P.H., Chawmam fM. T. HACKETT, vie* I RLES J. PASQUA W .M. GARRETT, M.D. LOUISIANA AIR CONTROL COMMISSION Louisiana State Office Building P.O. Box 60630 NEW ORLEANS 70160 DAVE L. PEARCE EVERETT JACOB JOHN E. TRYGG, tcchwcal sicait C k, t i V E o BACON ROUGE WORKS API? 29 71 Dear Sir: It Is requested that you complete the enclose return It to our office at your earliest convenience. We would like to reel eve a reply within thirty days of your receipt of this letter. The Louisiana Air Control Commission, created by Act 259 of the 1964 Legislature, has been charged with maintaining the purity of the air of our State. The Commission has been given certain specific duties including the collection and dissemi nation of information on air control. The Information collected will be held strictly confidential according to Commission policy. The Commission plans to continu this policy unless prevented from doing so by State or Federal legislation or legal action. In general, this information will be used developing the implementation plan for achieving and maintaining pure air for Louisiana. I realize that some questions may be difficult to answer. Give us the best information you can and if a question is not applicable, mark N.A. If there are questions, either call or write us. Your cooperation is appreciated. Very truly yours Enel sure ASI"PR 0004213 LOUISIANA STATE AIR CONTROlA'MMI S$ ION LOUISIANA STATE OFFICE B^.JING P. 0. Box 60630 EMISSION INVENTORY QUESTIONNAIRE New Orleans, La. 70160 Page I of 6 To: Allied Chemical Corporation___ Industrial Chemicals Division -2ZL (P. 0. Box No.) (Street Adaress) Ba ton Rou^e (City or Town) EBR La. 70821 (Parish) (Zip) PLEASE CORRECT IF NAME OR ADDRESS IS INCORRECT AUTHORITY: In accordance wixn the provisions of R.S. 40:2201 e+. seq.. The Louisiana Air Control Commission has directed the Technical Secretary to make a survey of Air Pollution in Louisiana and to report the results to the Commission. INSTRUCTION: (Please Read Carefully) File a separate report for each of you establishments physically located in . Louisiana. 2 Use accurate estimates when records ar not avaiIable. 3. Principal means the major portion of u half or more. 4a. Answer All Questions. If certain ques are not appI i < :ap|e to your activity, p indicate NONE or NOT APPLICABLE. b. Attach descriptions in cases where qus is not applicable. 5. IF OTHER is marked, specify in a I cas use additional sheets if necessary. .6 The policy of The Commission has been keep all information received in this questionnaire CONFIDENTIAL. The Commi plans to continue this policy unless c vented to do so by State or Federal leaislation or leaal action. I tern I A. Days per week normally in operation (check all That apply): f.ctivities l.{x]Monday 2.0Tuesdav 3.0 Wednesday 4. fiTlthursday 5.|X[Friday 6.(xjsaturday 7. X Sunday B. Days per year normally in operation: C. Peak production season: J5_ --, Days I .0Year round 2. [J Summer D. Shifts normally operated: 3.0Fall l.[x]Evening (4pm-l2pm, 3pm-1 I pm,' etc.) 4.0Winter 5.0Spring 2.0 Day (8am-4pm, 7am-3pm, etc.) 3.^x1 Night (I2pm-8am, llpm-7am, e E. Total number of employees at this establishment: (check range) Less than 5 2. 5.-49 3. 50-99 4.100-249 250-449 6.0450-749 7.0750-999 8.0cver 1,000 F. Type of Operation (Include brief summary of operations under ITEM 7, REMARKS! 1*0Chemical 4.0Mtning , 7.0Manufacturing IO.0Lumber 4 allied proc 2.0Petroieum 5.0Foundry 8.0Disposal' ll.0Metals 4 allied proc 3.0Food, etc. 6.0Machine 9.0Paper 4 allied l2.0Other (Name) products ASI-PR 0004214 EMISSION INVENTORY QUESTIONNAIRE STATE OF LOUIS 1AN/W AIR CONTROL COMMISSlW Page 2 of 6 Item I Cont'd) G. Raw Materials Used (Chemical name if possible or apllicable) Materials Amount per year Sodium Chloric le ("Variable Calcium Carbor iate Due to Coke Production) Ammonia Ethvlene Units Form (1 iquid, gas or solid) Liquid Solid Solid Gas G3 S How stored How trans: or shipoec Tanks Storage Pile Storage Pile Tank Cars PiDeliir Belts Belts Pipelin None______________ Pinelin H. Intermediate Products (Chemical name if possible or applicable) Materials Ethvlene Dichloride Chlorine Amount per year Uni ts (Variable-due to oroduction) Form (liquid, qas or solid) Liquid How stored Tanks Tanks How trans or shidds PiDelin barges PiDelin I. Principal Finished Products (Chemical names if possible or applicable) Materials Amount per year 1) Sodium Carbonate (Variable-due to Sales) 2) Vinvl Choride 3) Sodium Hydrox ide Units Form (liquid, How stored qas or solid) Solid Warehouse Liquid Liquid Tanks Tanks How trans or shioDe Belts, e le ~crew& Hr Conveyo' Pipes K ' Cars Pipes, c-Barges J. Ownership: 1.0 Private 2. | | Municipal 3. Q State 4.0 FederaI 5. 0Corporation 6.0Partnership 7.[3<|other Ind. Development Board Item 2 FUEL CONSUMP TION A. Report Quanti ties of fuels consumed last year B. COMPLETE THE FOLLOWING TARLE WITH LAST YCARTs imfqp^ATION FUEL OUANTITY UNITS Coal used for heat & power Coal used for production Light Distillate fuel oil. Nos. 1-4 (Heat & Power) Light distil late fuel oils. Nos. 1-4 (Production) None None None None Short tons Ga 1 lorls CUA! % su 1 fur weight % su1fu weight ASI-PR 00 04215 l EMISSION INVENTORY QUESTIONNAIRE STATE OF LOUISIANA AIR CONTROL COMM I SSI Oil L+em 2 FUEL QUANTITY ont'd) Residual or Heavy oils PLEASE Nos. 5-6 (Heat & Power) None NOTE UNITS OF MEASURE Residual or Heavy oils. Nos. 5-6 (Production) None TO BE USED 0. Gas-natural, manufactured or mixed (Heat & Power) 15,867,000,000 Gas-natural, manufactured or mixed (Production) E. Others - Specify kind and use .1. 2 3 UNITS Gal Ions DUAL IT % sulfur h weight PPM Meta Is 0.5 opm & sulfur b' Cubic Feet weight I tern 3 REFUSE COLLEC TION AND DISPOSAL A. Amount of combustible refuse disposed of Der year: I.| j Mere 365 Tons or vo I u m e (No. 2 8 & capacity Average 3V yds of waste containers) B. Form or type of refuse; (wood, rubber, paper, etc.) All types. ii --- ........ .. --i 1' mii^ 1 C. Principal methods of refuse collection: l.j__| Not Add Iicab Is -- 2.D City pickup 3.QRrivate pickup 4. Disposal on premises 5* Oother (Soecify) D. If private pickup, name of contractor and address: E. Principal Methods of Refuse Disposal: I.QNot Applicable 2.0Sanitary Landfill 3.n Open Dump 4. 1 11ncineratfon 5. I 1 Compost! nq 6. QOpen Burning 7.Q Other____________ F. Method of Incineration: I. Qn/A 2.Qsingle Chamber Incinerator 3.QGas Fired inciner 4.n^ultiple Chamber Incinerator 5.Q Boiler 6. Other ______________ G. Incinerator used: .__. N/A Manu facturer:_________________________________________________________________________ Model :________ ________________________ __ Years in operation: Pollution Abatement Facilities_________ Incinerator Capacity! Pounds per hour Hours of operation per week ASI-PR 0004216 MISSION INVENTORY OUESTIONNAI RE STATE OF LOUISIANA AIR CONTROL COMMISSION Page 4 of 6 2m 4 A. Particulate Matter and Approximate None Aerosols (exclude products #/HR Tons/Yr of combustion EMISSIONS 1. Carbonaceous Particle si ze Distribution (mirrnn range) Present but Unable to Estimate 2. Minera1 Solids 3. Organic Particles 4. Other 5. 6. R. Organic Gases or Vapors (exclude products of combustion) Ibs/hr Approximate (on stream) ft3/hr Tons/br Yr None I. Hydrocarbons (specify' a) VCM Process Vent (See Table I attached) b) I I 2. Halooenated (specify) a) VCM Process Vent b) c) 3. Oxygenated (specify). a) b) c) 4. Other (specify) (See Table I attached) None Inorganic Gases (include products of combustion (indicate if calculated from fuel) Approximate /HR I. Sulfur Dioxide (SO2) 0.15 2, Hydrogen Sulfide (HgS) 3. Halogens (specify) a) b) c) Tons/Yr Present but None Unable to Estima'i 0.7 (Nat. Ga 5 4. Other (specify) Hydrogen fold plant) (Also see Table II attache '125 550 ASI-PR 0004217 , ' EMISSION INVENTORY QUESTIONNAIRE STATE OF LOUISIANA AIR CONTROL COMMISSION Page 5 Of 6 em T ' EMISSION STACK A. N A M E or STACK Description INFOR- of Sources MAT ION Lime Kilns Kiln ;-Dust Collector N USE ,, Dust Collector C ADDI- Dust Collector S TIONAL Lime Slaker(MLT) SHEETS Vaoors IF NECES- .dime (MLT) Snails SARY Soda Column Vent Identi fication Cone. Rate Temp. Number PPM (cfs) F A1 to A13 A14 A1S A16 rablell 25 No Dat 3 - No Da t 1 No Dat 3 - 400 - - - A17 to A21 Water 7apor A22 to A23 Wa ter 7anor Exit Felocity Ft./Sec. 18 - Diam. Feet 1.33 3.00" 1.33 1.67 2.50 1.00 Elev. Above Grade 98 98 98 98 Can b< Same 1e Yes C: Ye? 7* 105 50 (LCL) B24 to B27 Filter Vacuum (LVFLR) 328 to B31 NHo Absorber(LAB) B32 to B33 L.A. Dryers B34 to BS9 Bag Dust Coll. S.A .B60 to B63 Table [I 73 70 52 tf 65 80 rr 3 70 tr 725 860 47 16 5 (No vi sable em i s s: ons) 1.33 1.33 0.50 7-00 1.00 177 122 28 17 0 170 ** 77 7' f Old Power House C64 to C70 Tablel r 555 300 Gas Turbine House D71 to D74 ft 4850 400 7 .0.00 96 8.00 100 60 (Continued-Next page) B. Stack Use: (indicate stack number from above) l*P)Not Applicable 2. All others Process Emissions 5`.34-59; 64-70;71-74 Fuel Combustion Product 4. Combined Item 6 A. AIR POLLUTION CONTROL INFOR MATION Air Pollution Control Units in use: 1. P None 2.PSett Iing Chamber 3. | Baffles 4. PElectrostatic Precipitator 5. I jMultiple Cyclones 6. [xjcioth Filters 7. 1 Udsorption 16.[ |Other (indicate efficiency) Vapor Recovery System Direct Fired Afterburner Other Powered Inertial Separator 11. ^Catalytic Afterburner 12,1 iDemister 13.pjscrubber 14. QCyclone 15. | ]Type Emission Monitor or Control System____ B. Do you have an established program of preventive or operational maintenance on your Air Pollution Control Equipment? I.Qn/A 2.{3ys 3,Qno 4. If Yes, Describe on separate sheet. It is part of the normal preventative maintenance program for the plant. ASI-PR 0004218 EMISSION INVENTORY QUESTIONNAIRE STATE OF LOUISIANA AIR CONTROL COMMISSION Page 5 df 6 (Ct ^P"rem 5 EMISSION A. N A M E or Identi Exit STACK Description fication Cone. Rate Temp. Felocity INFOR of Sources Number PPM (cfs) F Ft./Sec. MATION Raff Dust Coll-P&L E75 " D.A. F76 to F79 (Vo vi: sable emissi on) 'ff " USE Dense Ash RGS F8D (Water vaoor ) ADDI TIONAL Ducon RGS F81 ( " S.Clp Sect.-HpVent: ; G82 to G90 9S^+ TT 0.37 110 ) 7.5 SHEETS " IF NECES TT " Salt Scrub. G9l t* TT IT G92 CNo da ca (No da :a ) ) SARY N.C12 Sect.-HpVent! ; H93 to [95 (Water vaoor ) " " Mastic Pots f 19 6 "(Disco: itinue d use " Tr Lead Furn. H97 (Combu: st.sas es-lit tie lead " " Tinning Furi i H98 and smoke ) (Combu: 3t. ga ses-li ttle tin " " Acid dio H99 and HC1) (Combu 3t . '-IB ses-Str all amt. VCM orocess Vinvl Furnaces Ho a: id HC1 ) J100 Table [ 117 115 J1.01 to ,m > Table Cl 36 800 84 19 Di am. Feet 2.13 2,13 2.33 3 . no 1.50 1.33 3. no 1.07 2750" 0.83 1.50 1.33 1.67 STACK El v. Can b< Above Samp 11 Grade Yes or 170 Yes 19 7 ? 169 TT 21)5 ff 25 60 M 5 2 TT 40 TT 30 TT 30 TT 30 t* 30 TT 165 TT 50 TT B. Stack Use: (in dlcate stack number from above) I.ONot Appllc able 2. All others Process Emissions 3`. J 101 Fuel Combustion Product 4. H97 to H98 Combliled Item 6 A. Air Pollution Control Units In use: (Indicate efficiency) AIR POLLUTION CONTROL INFOR MATION 1. None 2. Settling Chamber 3. __Baffles 4. __Electrostatic Prec I p I tator 5. [^Multiple Cyclones 6. Qcioth Filters 7. 1 [Adsorption 16. n Other 8. T_ Vapor Recovery System ^Direct Fired Afterburn r JOther Powered Inertial Separator 11. IZ ZCatalytic Afterburner ^ r^Demister j"Zscrubber 14,Q ^Cyclone 15. C^Type Emission Monitor or Control System B. Do you have an established program of preventive or operational maintenance on your Air Pollution Control Equipment? I< Qn/A 2. PI Yes 3.Qno 4. If Yes, Describe on separate sheet. ASI-PR 0004219 . * EMISSION INVENTORY QUESTIONNAIRE STATE OF LOUISIANA W AtR CONTROL COMMISSION Page 6 of 6 am 6 C. Approximately how much money have you soent on Air Pollution Control Equ inner.- ^Tcont'd) and operation in the past 10 years or in the Years the plant has been 1n operation? ClNone Equipment $ 1,083,000 Operations 1,552,000 Combined S 2,635,000 0. On a separate sheet list air pollution abatement measures which are or otherwise incomplete. What is the projected reduction in emissions after completion (tons/year reduction)? (Include type and level of emissions for spec? fic years.) Item 7 REMARKS Please supply a simplified flow diagram or block diagram of plant or plants on a separate sheet. Type or print pertinent information. Include brief summary of process or operations. Item 8 PER SONNEL List plant personnel responsible for Air Control. (To be contacted for visits and communication) A. Name: Frank P. Turk Title Supervisor Exits & Effluents Telephone Mo. 356-3341 B. Name: A. Y. T,aVine ' Title SuDerintendent-Ouality Control Telephone Mo. 356-3341 C, Marne: P. B. Cornell Title Plant Manager Telephone Mo. 356-3341 Name of responsible member of operation Date Paul B. Cornell May 25, 1971 Title of responsible member listed above and address and telephone Mo. Manager-Baton Rouge North Works (Phone-356-3341) Industrial Chemicals Division, Allied Chemical Corp. P.0. Box 271 Baton Rouge,La Print or Type name of person preparing report, Frank P. Turk Title of above person Supervisor-Exits & Effluents Telephone No. 356-3341 Area Code 504 ASI-PR 0004220 TABLE I VCM Process Vent Addenda-Page 1 1) n2 2) ch4 3) 2 4) C02 5) ^2^4 6) 1-2 C2H4C12 7) CO 8) 1-2 C-jH^Clp 9) h2o 10) chci3 11) c4h5ci 12) c2h5ci 13) C2H6 14) c2hci2 % bv Volume 82.1 7.9 4.6 3.3 1.0 0.4 0.2 0.2 0.1 0.1 0.04 0.-03 0.005 0.0009 100.0 Lbs per Hour 23,150 1,128 1,480 1,460 284 418 48 166 25 146 39 23 3.84 1.25 . 28,372 Cu.Ft. per Hour 347,000 33,600 19,400 13,900 4,260 1,770 715 704 580 519 184 153 21 4 422,807 Tons per Year 101,500 4,940 6, 480 6,390 1,245 1,830 210 727 110 639 171 101 16.8 5.5 124,365 Stack Diameter Stack Height Vent Gas Temperature Vent Gas Flow Vent Exit Velocity = 16" ** 1651 = 115 F = 117.4 Cu.Ft./Sec. = 84 Ft/Sec. * 1) Nitrogen 2) Methane 3) Oxygen 4) Carbon Dioxide 5) Ethylene 6) 1,2 Ethylene Dichloride 7) Carbon Monoxide 8) 1,1 Ethylene Dichloride 9) Water 10) Chloroform 11) Chloroprene 12) Ethyl chloride 13) Ethane 14) Trichloroethylene ASI-PR 0004221 TABLE II Addenda-page 2 Inorganic Gases Including Products of Combustion Identification Tons per year N2 co2 CO 02 Lime Kilns A1 to A13 Soda Column Vent (LCL) B24 to B27 Vacuum Filter (LVFLR) B28 to B31 Ammonia Absorber (LAB) B32 to B33 Soda Ash Dryers (SHT) B34 to B59 Old Power House C64 to C70 Gas Turbine Power House D71 to D74 Lead Melting Furnace H97 Tinning Furnace H98 Vinyl Furnaces J101 to J112 125,436 133,744 322,749 5,121 198,500 62,230 2,870 65 968,000 158,500 1,770,000 336,000 10,007,424 491,424 (No data -- uStd 147,500 28,950 1,273 485 3,750 9,940 59,850 885 64,100 50,600 2,041,080 2,330 nh3 H2 -- 341 103 - 7- 129,600 - 275,000 - 409,968 ---------------) _______ - 21,660 ASI-PR 0004222 Item 6D fPage 6~) Addenda-Page 3 1) Design and install dust collecting systems on soda ash loadings into trucks and rail cars. The completion of these systems will probably be spread over the next five (5) years. The quantity of present dust loss is unknown. 2) Renovate and improve dust systems on kilns lime dischargers and conveyors. Action has been initiated and should be completed within a year. The present lime dust loss is unknown. 3) Plans call for purchase and installation of three improved bag dust collector systems to replace the ones in Nos. 1, 3 and 4 elevator towers. This is designed primarily to reduce present maintenance costs, but will also reduce dustiness. The replacement will be about one dust collector per year. 4) Four bag dust systems are to be replaced in the dense ash operating systems. Conditions will be similar to those in item 3 above. 5) Design and install a scrubber for lead and organic fumes from the cell construction furnaces at the chlorine caustic north section. Expect completion in 1972. 6) Provide chlorine recovery stripper on chlorine gas cooling tower condensate now going to sewer at chlorine-caustic north. 7) Provide vent condensers to reduce chlorinated hydrocarbons going to atmosphere. ASI~PR 0004223 A / T5 A i3 dbiS' -Pago 2 Q, p % f 7f ) , /* r .{Mens'-1 A S I PR 0 0 0 4 2 2 5" fK . r.-j > C* i --> ///?, ., 7 a'y-, Abt&iit 98.99%, //> 5 1 V-C. ScAV/3%fL CAXUUP - -> C/t 7-/> ~A cAa <------- JH>] <r^ e^/os 7~& A'e''J7*'/7Lt7/>rj<yAS T'PWi'Ji^ _ <"/* 4" <1 /P/rV'Z' ^ /QUEp/e# C- s-,' ' ot * o ; ,-L I r/. <CA/ OK/P/C M0A/O/.1 /X/^ 9.9<Qo/D ICA/ECie/A/P 7~0 Area r/i/P'Z Ptfp s-ror^A C ASI-PR 0004226 U_____ Fu rfffca SR/rJC STaFAf^S 3--- p%(ObUfJC7o\A/R pvXC- S/'Ilt F''o/Vi --UvtJFtLTR<?D TFtFtr sroxfi&e ' '!' ' '. K/irtO*t vfwATr>>1~r. ~7\ //% Ftforn C iflLS r ( 7-0 paufS 7 S' PS/4- ^ //ypfaSiTAj --> Pel. AoP/Tfo/J -------------------------- >5 yC^ /V/ ^*'<*' 7~/20l_ ---------------------- To i/cr*i /<oo ps/4- .V________ . cpaipkcsscr &/NP4 FFSO To <r cT <FCTS P/7 - PFFFotC. S' C 3z.S~G-pt- V PfvjS f/FFO r> -'//y j i i i pp/a/f ro CTS-F V ypFrjF-FA/ F'P'&sr/ . F'FFl ASI-PR 0004227 WtrtH Cunobn. i"cf 1 < f ` W V7')* ASI-PR 0004228 Item 7 (page 6) Continued Stacks G82 to H99 G82 to G90: This is the old electrolytic caustic chlorine operation. It consists of 19 electrical half banks of cells. Each bank contains 52 cells and has one Hg vent stack common to each cell of the bank. Only 18 half banks are in operation at any particular time. The electrolytic products are chlorine gas which is liquified, Hj gas which is vented and NaOH in brine solution which is further processed. G91 to G92: The above NaOH in brine solution is evaporated to drop out the salt which is recovered as pure dry salt by drying in a direct fired rotary dryer. The G91 stack is on the scrubber of the exit gases from the dryer. The G92 stack is on the scrubber of the exit air from the pneumatic conveying of the dryed salt. H93 to H95: These are hydrogen vent stacks on the new and larger electrolytic chlorine-caustic operation. The Hp gas from this operation is normally recovered as fuel to the Boiler house. The stacks are for emergency use. H96 to H99: The new cells requiie a bed of poured lead for electrical contact with the graphite anodes. A mastic is used to insulate this lead from electrical contact with the brine anolyte. After the anodes are depleted, the lead and mastic are recovered for reuse. Due to recent improvement, the mastic pots are now electrically heated, whereby practically no fumes go to stack G96. The recovered lead containing some mastic (also new lead) is direct fired for melting and reuse. The gases go to H97 which also picks up vent from a copper bar buffing station. All copper connecting bars are- buffed, dipped In acid and in flux (K99) and in a tinning vat (H98). ASI-PR 0004229