Document 7RnZndqEbg755J435qKqm8yN8
628
CHAPTER 37
1965 Guide And Data Book
Id view of the range of these variables, all available test data, application experience, and manufacturers' perform ance data should be considered.
TYPES AND APPLICATION
Table 1 .... Mechanical Collector Characteristics
Kind
Efficiency Parfide Siz* tango fa Micron*
>100 100-40 <10
CmsV tones (Pr*s~ ton Drop)
Dewripfion and ftnaatks
There are a number of principles involved in the opera
tion of industrial air and gas cleaners. They are illustrated.,
by the following types of cleaners:
``-i
1. Mechanical Collectors: Baffle Chambers, Centrifugal Col
lectors.
/!;
2. Wet Collectors: Air Washers,,Wet Filters or Packed;Towers; '`
Spray Towers, Centrifugal or Inertial Scrubbers, Venturi Scrub bers.
3.. Fabric Collectors.
4. Electrostatic Precipitators.
5. Adsorbers, Absorbers, and Combustion Devices. '''
Units employing these principles may apply them individ
ually or in combination. The important characteristics of any'
unit are: its collection efficiency, resistance to air or gas
flow (power requirements), ability to maintain specified
air or gas flow during its operating cycle, r>d mainf^nonm
requirements.
' * ' t-:
In relation to industrial air cleaners, efficiency of collec
tion is generally presented on a basis of weight "removal.
In many instances, collection efficiency is expressed in terms
of weight removal in specific particle sire ranges. Occasion
ally efficiencies are given in terms of' visibility or photo
metric evaluation. Under other circumstances
are stated by particle count. For most process recovery
problems and air' pollution control, the weight basis has
been adequate. When loss of visibility, is'the major problem,
light opacity measurements may be required.
From a hygienic viewpoint where air to be'recirculated,
only contaminant concentration in recirculated air'stream,
rather than collection efficiency, should be considered.
>
Correlation between the various-efficiencies is poor-due
to the wide variation in particle size, size -distribution, and
shape.
-
Resistance-or pressure drop through any given collector
is related to the operating principle, and varies as follows: low
resistance collectors, up to 2 in. water;-medium resistance
collectors, 2 to 8 in. water; high resistance collectors,'8 to 25 in. water.
In mechanical centrifugal collectors of the wet- or dry
type (power driven impellers or rotors) resistance.'alone
is not of significance since these devices are
air movers
and therefore the factor of paramount importance is'the
overall power consumption of the unit. -This is also true
of certain types of wet collectors which require-auxiliary pumping power.
The ability of any unii-to maintain- specified air or gas
flow (hiring its operating cycle is-also a function-of-its
operating principle. For example, inertial collectors of-the simple and centrifugal type are able to maintain constant
resistance regardless of concentration arid particle iize. How ever, adhesive materials may.collect at the entry, through out the unit, and at the exit, and thus cause a reduction'in
air flow and serious maintenance problems. With' the ex ception of packed towers and wet filters, wet collectors
operate at constant resistance throughout their operating
cycles. However, they, may also be' adversely' affected by
adhesive or corrosive materials.' Wet filters or packed towers
will eventually become clogged because of retention' of inert
dusts. Units employing fabric or. other,.'`filter media, .will
have resistance influenced by the concentration,., particle size, shape, and packing characteristics of the aerosoL Their
Settling Meand.
-'baffle cham bers
Low
Low
Low
A large chamber to re duce velocity to permit settling. Auxiliary baf fles are sometimes used to. improve perform ance.' ^
Requires large space.
large- High-' Me-
vdiame-
ter cy
to
clones
low
Low
Low'1
Considered as single body over 3 ft in diam eter.
Gases and material must be dry. Air-tight dust bins or continuous . re moval of material must be provided. Space' re quirements moderate. '
Refined, design cen- ' trifu-, gals
High
High
Me Me dium dium to . low
Available. as multiple small-diameter tubes', scroll-shaped bodiesj and multiple louvers. Gases and material must be dry. Air-tight dust bins or continuous re moval of material must be provided. Space re quirements moderate.'
Integral High 'rotor' type." ;
High' Me-"- See re Rotor acts as air mover
marks and separating element1.
to. Usually' limited to dry
low granular materials and
dry gases. Low space
requirements.
No external pressure
loss involved but power
requirements are higher
than
exhauster.
Slotted-- High scroll fan t '
Me--- bow'-'
to low
3eere- Separation takes place in rrmrlra in fan scroll.
No external loss involved but power requirements are- higher(than, usual exhauster.
overall resistance. during'the' operating cycle may increase gradually'over a' known or determined period. Auxiliary cleaning devices such as separate compartments, alternately shaken, reverse air flow,'or reverse jet air flow may main tain constant-or nearly constant resistance or insure only small' fluctuations in air or' gas flow. Electrostatic pre cipitators have .the outstanding characteristic of maintain ing' a constant' air flow with an accompanying low resist ance-' Adsorbers behave similarly to. packed towers in that they provide constant' resistance until the voids become seriously'plugged' with inert dusts. This generally requires a matter of several months on normal applications.
Industrial -Air and Gas Cleaners
629
-----
- Cod' r' -
Air washers
x-
...Table 2
Characteristics of.,Wet Collectors
Efficiency .
.Particle are rang# fa micron*.
>10
. 10-1
<1
Keatfoaco fa. Wafer
" Wafer Safe fa Gaffoa* . Matefeo-
Per 1000 aace Co H Cat
Dmcriptiaa and ftowela
High
Medium Low .
Low (less than 1)
MS.- Medium
Composed of one or more banks of low-pressure
sprays and flooded eliminator plates. Space
-'requirements-are .large.. Water is usually
recirculated.
r, -
Wet filters
High-. High
Medium Low (less - 3-8 ..than 1) n
. .Medium.
Composed of one or more banks of low-pressure sprays flooding packed cells of glass or other fibers. Space requirements are large. Limited to low loadings of solid particles.
Packed towers High High'
Medium High
5-10 High
Composed of granular or,,ceramic\ packing.
Space requirements large."Generally limited
' to gas absorption.
;
Spray towers
High Medium Low
Low
5-10" Low.'
Usually a vertical chamber equipped with low* pressure water sprays at the top or along
the walls. Baffle plates may be provided for ' contacting. Spaoe requirements medium. - Usually-applied for hot gases.
Centrifugal or' inertial
' scrubbers
High ` High'
Medium to high
Mediilml (see re marks)
See re-
'This classification includes most of the com-
!: mercial wet collectors. They may utilize
singly or in combination, low- or high-pres-
sure'sprays, wetted plates, rotating'mem
bers, liquid gas contact by induction or cen
trifugal action.
Some of these units (disintegrators) have high
'Overall power requirements for driving the
! rotor while others have high power con
sumption for raising water -pressures for
spray nozzles. -
*'
, Maintenance varies from low to high depend
ing on component parts.* Simple gas liquid
contact units would -be-classified as-low.
Units having rotating' members may vary
from medium to' high depending on the type
of service.
Venturi scrubber ' '
High High'
"High
.High' (12-25)
i -i-; v
5-10 ; Medium ? *!'
Consists of a simple venturi with low-pressure
sprays at throat foQowed by a cyclonic type
.separator.-Spaee requirements are low! Unit
* functions independent of grain loadings.1'
High-velocity at venturi throat may cause
i erosion problems.
`
: It-has been-ifound- that! inertial separators require /the least maintenance.'.Simple wet collectors-rank next rm-this respect. Complex wet collectors.and fabric:arrestors require maintenance on-a definitely scheduled basis.''Electrostatic precipitators require the usual -maintenance' connected with high-voltage equipment land, may vary widely. The main tenance of adsorber: type'-.unite .is. minimal and is based primarily on the amount"of inert material encountered;
MedianicaljCollectors- .
There are' many types'in^this'group: These' rahge'from simple'^tting'chambers utilizing' gravitational ' forces,' to
complex.centrifugal devices using abrupt directional changes or motor';driven rotors. They all have the desirable features of constant .'resistance during their operating cycle and do hot require any special construction for temperatures under 750 F.' Usually they require' less maintenance than other types of collectors.
On the bass of their important characteristics, mechanical collectors may be classified according to Table 1.
Wet Collectors
"rIn tiiese, collectors many methods are.used to,wet, toe contaminant arid remove it' from the_ air stream. A number