Document 7RnZndqEbg755J435qKqm8yN8

628 CHAPTER 37 1965 Guide And Data Book Id view of the range of these variables, all available test data, application experience, and manufacturers' perform ance data should be considered. TYPES AND APPLICATION Table 1 .... Mechanical Collector Characteristics Kind Efficiency Parfide Siz* tango fa Micron* >100 100-40 <10 CmsV tones (Pr*s~ ton Drop) Dewripfion and ftnaatks There are a number of principles involved in the opera tion of industrial air and gas cleaners. They are illustrated., by the following types of cleaners: ``-i 1. Mechanical Collectors: Baffle Chambers, Centrifugal Col lectors. /!; 2. Wet Collectors: Air Washers,,Wet Filters or Packed;Towers; '` Spray Towers, Centrifugal or Inertial Scrubbers, Venturi Scrub bers. 3.. Fabric Collectors. 4. Electrostatic Precipitators. 5. Adsorbers, Absorbers, and Combustion Devices. ''' Units employing these principles may apply them individ ually or in combination. The important characteristics of any' unit are: its collection efficiency, resistance to air or gas flow (power requirements), ability to maintain specified air or gas flow during its operating cycle, r>d mainf^nonm requirements. ' * ' t-: In relation to industrial air cleaners, efficiency of collec tion is generally presented on a basis of weight "removal. In many instances, collection efficiency is expressed in terms of weight removal in specific particle sire ranges. Occasion ally efficiencies are given in terms of' visibility or photo metric evaluation. Under other circumstances are stated by particle count. For most process recovery problems and air' pollution control, the weight basis has been adequate. When loss of visibility, is'the major problem, light opacity measurements may be required. From a hygienic viewpoint where air to be'recirculated, only contaminant concentration in recirculated air'stream, rather than collection efficiency, should be considered. > Correlation between the various-efficiencies is poor-due to the wide variation in particle size, size -distribution, and shape. - Resistance-or pressure drop through any given collector is related to the operating principle, and varies as follows: low resistance collectors, up to 2 in. water;-medium resistance collectors, 2 to 8 in. water; high resistance collectors,'8 to 25 in. water. In mechanical centrifugal collectors of the wet- or dry type (power driven impellers or rotors) resistance.'alone is not of significance since these devices are air movers and therefore the factor of paramount importance is'the overall power consumption of the unit. -This is also true of certain types of wet collectors which require-auxiliary pumping power. The ability of any unii-to maintain- specified air or gas flow (hiring its operating cycle is-also a function-of-its operating principle. For example, inertial collectors of-the simple and centrifugal type are able to maintain constant resistance regardless of concentration arid particle iize. How ever, adhesive materials may.collect at the entry, through out the unit, and at the exit, and thus cause a reduction'in air flow and serious maintenance problems. With' the ex ception of packed towers and wet filters, wet collectors operate at constant resistance throughout their operating cycles. However, they, may also be' adversely' affected by adhesive or corrosive materials.' Wet filters or packed towers will eventually become clogged because of retention' of inert dusts. Units employing fabric or. other,.'`filter media, .will have resistance influenced by the concentration,., particle size, shape, and packing characteristics of the aerosoL Their Settling Meand. -'baffle cham bers Low Low Low A large chamber to re duce velocity to permit settling. Auxiliary baf fles are sometimes used to. improve perform ance.' ^ Requires large space. large- High-' Me- vdiame- ter cy to clones low Low Low'1 Considered as single body over 3 ft in diam eter. Gases and material must be dry. Air-tight dust bins or continuous . re moval of material must be provided. Space' re quirements moderate. ' Refined, design cen- ' trifu-, gals High High Me Me dium dium to . low Available. as multiple small-diameter tubes', scroll-shaped bodiesj and multiple louvers. Gases and material must be dry. Air-tight dust bins or continuous re moval of material must be provided. Space re quirements moderate.' Integral High 'rotor' type." ; High' Me-"- See re Rotor acts as air mover marks and separating element1. to. Usually' limited to dry low granular materials and dry gases. Low space requirements. No external pressure loss involved but power requirements are higher than exhauster. Slotted-- High scroll fan t ' Me--- bow'-' to low 3eere- Separation takes place in rrmrlra in fan scroll. No external loss involved but power requirements are- higher(than, usual exhauster. overall resistance. during'the' operating cycle may increase gradually'over a' known or determined period. Auxiliary cleaning devices such as separate compartments, alternately shaken, reverse air flow,'or reverse jet air flow may main tain constant-or nearly constant resistance or insure only small' fluctuations in air or' gas flow. Electrostatic pre cipitators have .the outstanding characteristic of maintain ing' a constant' air flow with an accompanying low resist ance-' Adsorbers behave similarly to. packed towers in that they provide constant' resistance until the voids become seriously'plugged' with inert dusts. This generally requires a matter of several months on normal applications. Industrial -Air and Gas Cleaners 629 ----- - Cod' r' - Air washers x- ...Table 2 Characteristics of.,Wet Collectors Efficiency . .Particle are rang# fa micron*. >10 . 10-1 <1 Keatfoaco fa. Wafer " Wafer Safe fa Gaffoa* . Matefeo- Per 1000 aace Co H Cat Dmcriptiaa and ftowela High Medium Low . Low (less than 1) MS.- Medium Composed of one or more banks of low-pressure sprays and flooded eliminator plates. Space -'requirements-are .large.. Water is usually recirculated. r, - Wet filters High-. High Medium Low (less - 3-8 ..than 1) n . .Medium. Composed of one or more banks of low-pressure sprays flooding packed cells of glass or other fibers. Space requirements are large. Limited to low loadings of solid particles. Packed towers High High' Medium High 5-10 High Composed of granular or,,ceramic\ packing. Space requirements large."Generally limited ' to gas absorption. ; Spray towers High Medium Low Low 5-10" Low.' Usually a vertical chamber equipped with low* pressure water sprays at the top or along the walls. Baffle plates may be provided for ' contacting. Spaoe requirements medium. - Usually-applied for hot gases. Centrifugal or' inertial ' scrubbers High ` High' Medium to high Mediilml (see re marks) See re- 'This classification includes most of the com- !: mercial wet collectors. They may utilize singly or in combination, low- or high-pres- sure'sprays, wetted plates, rotating'mem bers, liquid gas contact by induction or cen trifugal action. Some of these units (disintegrators) have high 'Overall power requirements for driving the ! rotor while others have high power con sumption for raising water -pressures for spray nozzles. - *' , Maintenance varies from low to high depend ing on component parts.* Simple gas liquid contact units would -be-classified as-low. Units having rotating' members may vary from medium to' high depending on the type of service. Venturi scrubber ' ' High High' "High .High' (12-25) i -i-; v 5-10 ; Medium ? *!' Consists of a simple venturi with low-pressure sprays at throat foQowed by a cyclonic type .separator.-Spaee requirements are low! Unit * functions independent of grain loadings.1' High-velocity at venturi throat may cause i erosion problems. ` : It-has been-ifound- that! inertial separators require /the least maintenance.'.Simple wet collectors-rank next rm-this respect. Complex wet collectors.and fabric:arrestors require maintenance on-a definitely scheduled basis.''Electrostatic precipitators require the usual -maintenance' connected with high-voltage equipment land, may vary widely. The main tenance of adsorber: type'-.unite .is. minimal and is based primarily on the amount"of inert material encountered; MedianicaljCollectors- . There are' many types'in^this'group: These' rahge'from simple'^tting'chambers utilizing' gravitational ' forces,' to complex.centrifugal devices using abrupt directional changes or motor';driven rotors. They all have the desirable features of constant .'resistance during their operating cycle and do hot require any special construction for temperatures under 750 F.' Usually they require' less maintenance than other types of collectors. On the bass of their important characteristics, mechanical collectors may be classified according to Table 1. Wet Collectors "rIn tiiese, collectors many methods are.used to,wet, toe contaminant arid remove it' from the_ air stream. A number