628 CHAPTER 75 1962 Guide And Data-Boo^? sure rise, if the heating continues for any length of time, may result in rupturing of the tank. If the tank water is not confined, continued heating would, of course, cause no increase in pressure beyond ordinary line pressure. However, the temperature would continue -to in crease. If this should happen at elevated temperatures, the flashing of the water into steam might cause a serious tank explosion. In order to guard against the development of excessive pressure inride a hot water storage tank (owing to the ther mal expansion of the water), it is customary to install a spring-loaded pressure-relief valve which is set to open at a pressure about 20 psi higher than the normal line pressure. The amount of water discharged by any pressure-relief device is usually quite small, since it takes only a small quan tity of water to relieve any pressure rise due to the thermal expansion of the water. The rate of discharge should be such as to limit the pressure rise for any given heat input to' 10 percent of the pressure at which the valve is set to open. For any given installation, the discharging capacity should be in excess of the water to be discharged by the heater. The heater discharge Qm in gallons per minute may be computed by Equation 5: 0, - 0.000056 (5) where b is the heat mput of heater in Btu per minute. ; To prevent danger of overheating, temperature-relief de vices should be used. One type of such a device has a fusible plug of metal which melts at about 212 F. The hot water then runs from the opening until the device is serviced. A better type of relief device is one which incorporates a bellows or bimetallic disc, which opens at a temperature of 210 F and doses when the temperature drops to approximately 160 F. Another type of safety device is a fuel cut-off switch or valve in which a fusible plug is melted by excessive water temperature. The fuel supply is cut off until the fusible plug is replaced. Combination temperature and pressure relief valves also are available. The capacity of temperature-relief devices may be calcu lated by Equation 6: (?. - 0.00086 (6) where Q. and b denote the same quantities as in Equation 5. Pressure-relief valves should be installed in the cold water line near the tank, on the tank ride of any shut-off device, and out of contact with the hot water in order to prevent excessive corrosion and lime deposit on the valve seat. Temperaturerelief valves, in general, must be installed at the. point of maximum water temperature, usually in the tank, but if in stalled in the pipe, must be on the tank side of any shut-off device. SOLAR WATER HEATERS Solar heaters utilize the energy of the sun for heating wa ter. The successful operation of such heaters requires the availability of sunshine practically every day in the year, which has limited their use to Florida and-the southern por tions of California. When supplemented with some other means of gas, coal, or oil water hearing, solar heaters may be used in climates where sunshine may be more or less inter mittent. They have been used in summer homes as far north as Chicago. When properly installed and proportioned, solar water heaters render satisfactory service, especially in cli mates where the outdoor temperatures are high and extremely hot water is not necessarily desirable. Such installations con sist essentially of a storage tank, heating coil, and hot bo* ' The coil is installed in the hot box, and is arranged to circulate water to and from the storage tank. The advantage in the j use of this type of heater is the fact that it requires no fad The same materials should be used for the coil, circulation \ lines, and tank. A copper coil is more efficient in absorbing heat in the box, but galvanized iron or steel may be stituted, depending on the local water conditions, cost, and other considerations. The storage tank must be able to store sufficient heated water for the night period of about 16 hr when the coi] is not functioning, or is operating under such poor sun coodj. tions as to make its heating effect negligible. Due to the fact that the no sun period includes the night period when little or no hot water is used, an available storage of 50 percent of the average daily usage is considered .adequate. Since about 25 percent of stored hot water cannot be drawn out of * storage tank before the incoming cold water reduces the tem perature of all of the water in the tank to an unsatisfactory point for usage, the equation for calculating the storage ca pacity of the tank becomes: S Qd X 0.50 - 0.666Q4 0.75 (7). where 8 -- storage capacity of tank, gallons. Qd " average duly usage, gallons. Thus, for a family of four persons using an average of 40 gal of hot water per (person) (day), the size of the tank would be 4 persons x 40 gal x 0.666 or 106 gal, and the nearest standard size of tank would be used. The tank should be well insulated to prevent undue loss of heat during the 16-hour period when the coil is inoperative, and it should be located as high as possible in the building (under the peak of the roof if such exists) so as to secure a maarimum circulation bead from the coil. The hot water supply line to the house, as shown in Fig. 15, is connected to the top of the tank and serves to vent the air from the t-anlr through the hot water faucets as fast as it accumulates. The cofl should be of the return-bend type (square or slightly rectangular in form), and should have the pipes run ning east and west, with the coil on the south ride of the building where it <*An receive the full sun effect all day long without shadows from the building itself, or from the ad jacent obstructions such as trees or other structures. The coil should be placed as low as possible in relation to the storage 829 Oerign Me - Table 18.... Suggested Solar Heater Design Data* lated on Safe of 30 Gal per Day per Pmoo Bated oa Rate of 40 Gal par Day par Person /f.Voccupants " residence..................... 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SjTotiweter used at night, gal per person.. 15 15 15 15 15 15 15 15 20 20 20 20 20 20 20 20 ^Hot water used at night, gal total---------- 15 . 30 45 60 75 90 105 120 20 40 60 80 100 120 140 160 Stained in tank, 25 percent, gal.............. 4 8 11 15 19 23 27 30 5 10 15 20 25 30 35 40 'Tank'capacity required, gal........................ 20 40 59 75 94 113 130 150 25 50 75 100 125 150 175 200 ,t water used during day, gal................. 15 30 45 60 75 90 105 120 20 40 60 80 100 120 140 160 Tots) water to be heated: :VGal pw 8-hr period............................. ;... 35 7C 104 135 169 203 235 270 ^GaTper hour.................................................. 4.5 9 13 17 21 26 29 34 45 90 135 180 2251 27C 315 360 6 12 17 23 28 34 39 45 Copper coil required: ~'Surface area, sq ft....................................... 25 50 75 100 121 145 168 192 32 64 96 123 160 192 224 256 -^Equivalent'length 1-in. coil, ft............... .100 200 300 400 4S4 580 664 768 128 256 384 512 640 768 896 1024 Box size: '(Area/sq ft...................................................... ';:width, ft......................................................... .-^Length, ft............... ....................................... 25 4 6 5C 75 100 121 145 168 192 32 64 96 128 16C 192 224 256 f 78 9 10 10 11 4 e 8 9 10 11 .12 12 8 11 12.5 13.5 14.5 16.5 17.5 8 10 12 14 16 18 19 21 ,f8u Effect ud tbe Design of Bolir Heaters, by B. L. Alt (ASHVE Tunicnon, VoL 41,1935, p. 131). tank level, such as on a porch roof, the roof of a one-story extension or, if necessary, even on the ground. Both the coil and the circulation lines should be designed to facilitate the circulation flow as much as possible, "ring long-radius copper fittings or recessed galvanized-iron fittings to match .thematerials of the coil, circulation lines, and tank. The coil should be inclined, as shown in Pig. 16, so that the north end -is raised above the south end to secure an- angle with the horizontal of about 53 deg. This, will result in tbe inlet end of the coil being on the south ride (or bottom), and the outlet end being on the north side (or top). This will satisfy condi tions along the 30-deg N latitude, which includes the por tions of Florida and Southern California where these heaters are most frequently used. The hot box is usually constructed of wood on the four tides and bottom, and is insulated. Glass are placed over the top of tbe box which should be airtight. The interior sur faces should be painted white to reflect the heat, while the coil should be painted black to absorb the beat. Hie box need not be deeper than necessary to house the coil and to protect it from the weather. The addition, on the bottom of the box, of a light gage copper plate to which the pipe of the coil is soldered for good metallic contact, will add to the amount of heat received' by' the coil, due to the fact that this plate will receive all of the sun's rays which fail to directly strike the cofl. The heat from this source is transmitted to the cofl through ihe plate rather than from the heated air surrounding the coil. Other wise, only part of the heat enters the coil, the balance being transmitted through the glass. Design data given in Table 17 may be used with judgment in selecting the size of solar heater cofl and box for a particu lar application. These data are based on consumptions of 30 - and 40 gal of hot water per (day) (person). DOMESTIC HOT WATER BY HEAT PUMP Hot water may suitably be obtained by using a heat-pump installation. The hot water heater may be either a heat ex changer installed just ahead of the compressor of a heat- Fig. 17.... Heat Pump Arrangement for Hot Water Supply