Document 7RmqQZXJbLLVKgELZewnd56wg
90
CHAPTER 4
1949 Guide
this 'velocity to compute a corrected value of IViU and repeating' the process, a more nearly correct value of Qi is found. This cut-and-try method may be continued for several more cycles, but generally the first or second correction will be found sufficient.
Another method would be to use the value of K corresponding to' Nne = ". modifying this with a factor involving the rate of flow, deter mined from the temperature, and the differential and static pressures. This method is used by the American Gas Association3.
STEAM FLOW MEASUREMENT
While steam may be considered as a gas, its measurement differs from that of the usual gases because of a number of factors. Equation 52 serves as the starting point. Since it is usual to measure the differential
Fluid-Flow'1'
91
gravity of mercury; and the numerator is the difference in specific gravity between mercury and water. Hence, Equation 61 becomes
Qt = 345.65 KW
(63)
Steam is commonly measured in terms of weight, and since
tPh = pQf
where Wh = the rate of flow in pounds per hour.
,
(64)
Wh = 345.65 KDf VA.P . ...
(65)
The expansion factor Y, and the factor P, correcting for the expansion of the orifice plate with the temperature, must then be applied, so: that
u>h = 345.65 KYPDfy/hTp
(66)
which is the final form, of the equationifor the flow of steam through orifices. Values of K may be obtained from Figs. 7, 8, and 9, according to the
Fig. 12. Expansion Factob for Air and Other Diatomic Gases Applicable to Flange, Radius and Vena Contracta Taps
pressure in inches of water, it is necessary to convert hi, the head in feet
in terms of the flowing' fluid, to haw, the actual head in inches of water, using the equation:
. A.w Pw
(60)
where.
Pw 1 the density of water at'60 F (62.37 lb per cu ft). P the density of the flowing fluid.
Substituting Equation 60 in Equation 52 gives
Q, = 359.15 KDf - 'h*
(61)
In steam measurement, a- constant head of water is maintained overeach leg of the manometer by means of condensing chambers, in order to keep the heat of the steam away from the meter. As. the mercury level fluctuates, the difference in head as recorded on the chart, therefore, is not .that due -to mercury alone, but to mercury minus an equivalent head of water. To correct for this, the equation:
A,, = A, 13.557'
(62)
is applied to Equation 61. The denominator in Equation 62 is the specific
Fig. 13. Variation of Orifice Plate Expansion Factor, P, with Temperature and Material
pressure taps used. Y may be computed from. Equation. 59. Fig. 13 gives values of the correction factor P, according to the temperature, and the material of the orifice plate. Values of the density, p, may be. obtained from steam tables, such as Keenan and Keyes4, which are widely, used.
METERING LIQUIDS
Orifices are also used for metering liquids,^ and Equation 52 serves again as a starting point for developing the working formula. Again,-.it is necessary to convert ht to h,,, the actual head in inches of water, by sub stituting Equation 60. It is also necessary, to correct for the weight of the fluid above the manometer, and since this may be other than water, it is better to use an equation of more general form than Equation 62^
13.557 - --Pt
P
-- A,
13.557
(671