Document 7RQq7ge5wgQOQE8V9DJGN3NO8
T h e El e c t r ic St o r a g e Ba t t e r y Co m pa n y
ALLEGHENY AVE. and 19TH ST., PHILADELPHIA 32
Exie
BATTERIES
December 6, 1948
Robert A. Kehoe, M.D. Kettering LaboratoryUniversity of Cincinnati Cincinnati 19, Ohio
Dear Doctors
Under separate cover we have forwarded blood and urine speci mens on our employee,
No subjective symptoms were admitted by this employee. How ever a rise in his stipple count prompts this special review.
has been with the Company since June 24, 1948 and has worked in a lead department since. Our records show his stipple counts as follows:
7-28-48 - 0 stipples - Hgb. 93%
8-19-48 - 3
It
_ " 89%
9-17-48 - 2
!!
* " 83%
10-20-48- 3
N
-- m%
11-17-48- 32 ft
-- " 96
Recheck 11-24 - 26 stipples - Hgb. --
12-2-48 - 9 stipples - Hgb. 86^
Kindly favor us with your report in signed duplicate together with a single bill.
Very truly yours,
FBLsRB
.
F. B. L A M K M , M.D., MEDICAL DIRECTOR
' : \
H0004103
Name : Materials Submit teds
Requireds
A. Tomasetti
Urine and Blood
12-10-1^.8 b y Dr. L a n a h a n , E l e c t r i c S t o r a g e B a t t e r y
Company, Allegheny Ave and 19th Street, Philadelphia 52, Pa.
Lead Analyses
URINE
Analysis Number Volume Specifi c Gravi ty Mg. Pb/Liter
- I4.8A-IO826
- 66 ml.
- 1.020 - 0.10
BLOOD
Analysis Number
- I4.8A-IO827
Weight
- 21.3 Grams
Mg. Pb/lOO Grams
- 0 OI4.5 (Dithizone)
,L'ne, coneentx-abion or lead In ine blood is veil vithin-normal'
' limits Ciiiii J..I1 t he urine being near- the upper revel or norrnax
v a l u e s . : . .' -
1 hese x-esax Is are not .cotipa d o l e vxth the diagnosis oi ciumtism.
r -
Samples Collected:
.Signed : ________ . p _;_____ ... Samples R e c e i v e d :
.;O D BX`I >1 . hence , m .1. Samp l e s Rep o r t e d :
12-2-14.8 I2-IO-I4.8
12-16-14.8
l ^ g 0004 105