Document 7ROjK1m7Q2KryXNZrnqR9E1KB

FOR20t To: Fro*: Memorandum A. C. Varner UNIROYAL CHEMICAL Ol<riai*n ai UNIROYAL, Inc. April 19, 1974 CBW RLK CHK BRL ^FM-REC ACW JJT RJD URL 2 0 3 2 5 Pursuant to conversations vlth all parties concerned the following participation of the MARVINOL R&D - Process Development Croup In the VC monomer problem Is indicated. 1. Plant Monitoring Under the supervision and control of LFK (and REC) the pilot plant foreman and five operators will participate in plant monitoring and other activities as needed. 2. Pilot Plant Work Work on steam stripping, high per cent conversion and solvent cleaning projects in the pilot plant as priority projects taking precedence over our regular process development work. 3. Technical Service Visit Uniroyal and other customer plants, warehouses, shipping facilities, etc., to make appropriate measurements so we can, as a technical service to our customers, determine VC concentrations and make appropriate recosanenda 11 ons. 4. Industry Meetings Be available for, participate in, and provide technical backup at SPI, MCA, and other industry meetings on this subject. The normal rate of Factory Service charges will be maintained. The bal ance pf time will as usual be charged to R&D. ACW:dmb iMTFRrOMPANY CORRESPONDENCE I INSTRUMENTS ft LAB Recenf Developments m Vinyl Chloride Analyzers Detects vinyl chloride Very small concentrations of vinyl chloride in air mw he measured with portable, battery-operated indicator that weighs only 7 lb. It has full-scale low range of 0-300 ppm vinyl chloride, with 2 higher ranges available through use of a selector switch. (Model TLV Sniffer -- Bacharacb Instrument Co., division erf Ambac Industries, Inc., 625 Alpha Dr., Pittsburgh, PA 15238.) Orel* 179 opposite testpae*. Rent the machine that makes the toughest mixing routine R! thi- Rf '.J; n CONT'NU O'Jo PROCr Sf.on lc a f oni i`iii` rt ! :ir'd ijm1 In nm. b-fnd .2 O' pn! / '-H" r ip (w.'h hiM oti O' roo1 :rj) tbo r.f'r: ;,o'ri-, c b'qh v.Mrosry' you ro now h.no with a butch mix < VVhfi you've r.pop bow much r.ru: be lia.-ed--10 to 00 pci'ent-b ibe unit as it';, n.i/inq lcIt can do it in as little us two yf-.'irs1 Defouj yo.i tent you wisb to run tests m Our iubn'.j CO'y Fine Just c;;vu us .i ca'I Rtsirico Cortirunu'- Pitut's C.O's are made v.-ith se!` cl'sn mg agitaio'a I'tvi '? io 36 m. in diooieter Wnte today for COrrplele inJonrialion Monitors vinyl chloride from below 0.1 ppm Flame ionization gas chromatograph detects vinyl chloride from below 0.1 ppm to over $00 ppm in air. Instrument is designed for on-site analysis. Portable gas chromatograph is used along with a column and optional gas sampling valve to provide analysis, (Mode! 511 flame ionization gas chromatograph -- Analytical In strument Development, Inc., Route 41 & Newark Rd., Avondale, PA 10311.) C*rcte 18! opposite last peas. Measures vinyl chloride down to 1 ppm Vinyl chloride and other chlorinated organics such as methyl chloride can be monitored with an instrument that features fuB- cale sensitivity as low as 1 ppm, making detection limits down to 5 parts per billion (nib) practical. Complete systems which permit sampling of extremely adverse conditions multipoint sampling of many different plant loca tions are available. Multipoint reeosders are also offered to permit continuous recording of atmospheric conditions. (VCM monitor -- Areas, Inc., a division of Anacon, Inc., 6400 Westpark, Suite 300, Houston, TX 77027.) Ctrete 182 opposite test p*o. Vinyl chloride monitored in low ppm Detector system continuously monitors for presence of low ppm concentrations of vinyl chloride in ambient atmosphere of manu facturing, process, and storage areas. Typical range of measurement It 0 to 100 ppm vinyl chloride. Audible/visual alerts automatically whenever concentration level reaches 50 ppm. Alarm setpoint is field adjustable and can be set to values barer than 50 ppm. Unit can be equipped with indicating and/or recording readouts, multiple alarm setpoints, time-share sample programmer, automatic calibrator, or tone-weighed average concentration exposure printout for each 8-br work shift. (Series 9000 detector system -- Devco Engineering, Inc, 36 Pier Lane West, Fairfield, NJ 07006.) Clrete 183 opposite test page. > TELEDYNE 9C: SO'.t-' R'CtHi A'JO AVF NJf YORK. V: NNStlVANlA 1 ?^f (: 64P TIIFX ft- IK HIGH INTENSITY MIXERS DOUBLE ARM MIXERS DUAL LEVEL MIXERS Ciete 180 opposite test page. 82 JULY 1974 CHEMICAL MOCES8ING Craptete 0-14 pH rage oajtoredtyaalyzBT i Process analyzer monitors ; complete 0-14 pH range and ' in expanded scab mode, any ' two pH units can be displayed with a resolution of l/100th of a pH unit. Stability is to within 0.01 pH unit/week. Designed for stringent water monitoring applications, analyz er incorporates two electrodes -- a glass measuring electrode and a platinum reference type. Both are fitted into a non-clog ging, dual-chambered aensor block. Port windows in tbe block permit observation of the sample and condition of electrodes. Block Is rated for line pressures of 100 p and temps of 150*F. (Model TAl-pH analyzers -- Hach Chemical Co., PO Box 907, Ames, la 50010.) Oaete 184 opposite last pago. URL 2 0 3 2 6 i.2 SL m Z " O vyo m< M fXM Methane, Air Acetylene Ethylene Ethane Water Propylene Propane o l^lethyl Alcohol S f^lethyl Chloride Vinyl Chloride Isobutane 1,3 - Butadiene Butene -1 Isobutylene Trans Butene-2 n-Butane Ethyl Alcohol Cis Butene - 2 Ethyl Chloride Acetone Dichloromethane Vinylidene Chloride n-Pentane n-Hexane lzioz ian > > o'S o 2. Z % SL 44077 VINYL CHLORIDE ANALYSIS 3> *Z 13 I? T3 to rz r~ 01 a 3 H- X "n 3M ^O <0) 2 O 01 0) b- H H nh-> 0 HC CD X V) * CD 3 nO b- X ai h- nz URL 2 0 3 2 8 Vinyl Chloride Detectable from less than 0.1 ppm in air > OSHA & EPA Approved Method No Interference Rapid ON-SITE Analysis Completely Portable Self-Contained Compatable with Charcoal Sampling Tubes Analyze for Hydrocarbons and Industrial Solvents in air. The Model 511 Flame Ionization Portable Gas Chromatograph is used to perform the analysis of vinyl chloride in about 3V: minutes. The detector is linear in response over a concentration range from below 0.1 ppm to over 500 ppm with a minimum detectable level of at least .05 ppm. The design characteristics of the instrument result in a stability which previously was only attainable with laboratory instruments. Consequently, only daily calibration is required. AID can also supply all material for calibration. One of the basic concerns of the hygienist is the possible interferences of other compounds which would lead to erroneous determinations. To our knowledge, there is no chemical interference as indicated in the nomograph pre sented on the front cover. This graph also demonstrates the ease of obtaining additional chemical information from the work environment which may be important in the future. The accompanying chromatogram is of an industrial atmoshere. With proper notation, this graph can be held as a permanent record. Simpie calculations performed directly on the chromatogram allow rapid concentration determinations. Complete training on your instrument is available at our factory. AID application staff is available as a no-cost con sultant. This allows the customer to extend the capability of the instrument to other analytical areas using the basic flexability of the hardware. This instrument may also be used to analyze CSj extracts of charcoal tubes. This^pability, in conjunction with the portability, provides a complete system for environmental health impact studies. For more information on the Model 511 Portable Flame Ionization Gas Chromatograph, vinyl chloride analysis, and other AID Portable Chromatographic systems, please fill in and return the postage paid mailer below. I require this for: D Immediate Procurement Possible Future Procurement Hies Only Please have Field Engineer Call My Application is: _________________ _________________ NameTitle Company_____________________________________________ AddressZip _ Phone - Product Literature CC for Vinyl Chloride Analysis Additional information on Vinyl Chloride Detection Air Pollution Analyzer Model 514 ppm level CO, CH* & total Hydrocarbon O Tracer studies Model 510 (EC) Improved Orsat analysis Model 512 Ambient trace Sulfur Com pounds Model 513 (FPD) \ I NEWSProcess Design Vinyl chloride detective This flasher is an integral part of a new system developed by the Bendix Corp.'s Process Instruments Div., Roncevene, WV, for the detection of vinyl chloride--a widely used chemical sus pected of causing liver cancer in some industrial workers exposed to it over long periods of time. An electrical heater in the assembly provides the energy to flash the collected sample from the absorption tube into the gas chromotograph for analysis. With the system, vinyl chloride can be monitored in concentrations as low as SO ppb. which is well below the one ppm detection standard now being proposed by the government's Occupational Safety and Health Administration (OSHA). URL 2 0 3 2 9