Document 7RLp7VLoyDQL65Q4RjE4qpjaB

Du.il I`rnhl( in in hitlustrv 39 meet existing codes, Init a? dust-tietlit as Imniaii ingenuity ran design tliein. Alter the equipment is installed. it will lie the purchaser's responsibility to see that it is regularly inspected ami maintained to perform the service for which it was originally designed. And we refer again to the employee's responsibility. When he elects to work in a foundry, he should lie willing to cn-otteratc and wear the safety devices which arc provided by his employer, and it will he the purchaser's responsibility to see that the equipment is well cared for and properly maintained. Our industry is a basic one and we hope that it will long continue to he essential. For this reason we want to assure those who are sitting on the side lines that it is our determination and hope that, with the help of those in the medical profession who have given so generously of their time in scientific study, we can soon determine die actual extent of the hazard. --" In the meantime, while many diverse opinions are being brought into agreement, it is imperative that we give more than passive assent to suggested measures of precaution or improvement. The accomplishment of worth while results depends upon the diligent and active co-operation of everyone concerned and the utilization of ail known means of prevention and control. Only through united effort can we hope to accomplish an effective program which will give maximum of advantage to employers and employees alike, anti to such an etui we arc confident the foundry industry will continue to dedicate its earnest and conscientious efforts. How to Determine the Dust Content of the Atmosphere in Dusty Industries By DR. E. G. MEITER Director, Industrial -Hygiene Laboratory, Employers Mutual Liability Insurance Co., Milwaukee, Wis. The importance of atmospheric dust as an agent in the causation of respiratory disease lias long liccn known. However, it is only within the last few years that this subject has achieved medical and legal importance in dusty industries. I'.ecnttsc ..i the extension of compensation laws to include occupational diseases, and through an everincreasing number of legal suits against industrial concerns hv employees claiming disability tine to dust inhalation, there is need for a severe attack rat the pruhlcm of eliminating or otherwise coinlvuing the dust hazard. In order to intelligently control the dustiness of the air. the amotmt of dust present must lie determined. With a given dust, two factors are usually consult red: ft) the mmdier of dust particles in a given quantity of air, which is usually expressed in millions nf particles per cubic foot nf air; (2) particle-size, usually expressed in a size frequency distribution curve, that is tile percentage less than stated size is plotted against the size of particles. Instruments Used for Determining Atmospheric Dusts Many instrument* have liccn devised for determining the dust concentration in air and it may lie well to give a brief historical review of -tin's subject. The South African investigators iwgan using tlte sugar tulic method for the sampling of atmos pheric dust in 1011; the same method was used by the U. S. itorcan of Mines as early as 1014. Tty this method a measured volume of the dust air is. passed through 40 T-vcnty-sccnnd Congress--National Safety Council a lulic containing granulated sugar, which filters out the suspended dust. At the laboratory, the suear is dissolved in water amt tlic uuiulicr of dust particles arc deter mined lv counting those in a small volume of the sugar solution under a microscope. Tills method of dust sampling had certain disadvantages, the chief of which was the fact that the purest commercial sugar contained a certain quantity of dust, which introduced considerable errors, especially in those samples containing a lotv dust concentration. To overcome the limitations of the sugar tube method various other devices were developed, one of which was the Palmer apparatus. This apparatus consisted essentially of a pear-shaped glass bull), the lower end of which terminated in a U-tuhe or trap. .Suction was applied to the glass hull) by means of an electric exhaust fan and the volume of air measured by means of a Petot tube. Dust-free dis* tilled water was put into the U-tube. The air drawn through the water in the trap broke it up into a spray within the larger portion of the sampling hull), which washed out and retained the dust. The dust so obtained was analysed by the usual method*. The Painter apparatus also bad certain disadvantages, the chief of which was that its efficiency as a dust catcher was low. In the search for a more portable type of in strument, which at the same time would yield rapid results, the South African in vestigators introduced in 1916 a new instrument known as the Kotre konimctcr. Tlic konimeter samples dust by impinging a small volume of air against the surface of a vaseline-coated glass plate, the vaseline serving to catch the dust tiarticlcs. The dust retained on the glass plate was then counted under the microscope at a suitable magni fication. The chief disadvantages of the konimctcr are that in atmospheres containing a high concentration of dust, the spots are loo dense to allow counting the individual particles and the method can, therefore, dot lie used in such eases, also many samples bad to l>c taken to secure a correct average determination in places where the dust concentration was variable. As a result of the different methods of dust determination lieing used by the differ ent governmental bureaus and others, it was soon found that the various dust-sampling methods did not yield absolute results, consequently some confusion arose in inter preting the various dust studies. In order to arrive at some basis of comparison the U. S. P.ureau of Mines conducted a laboratory study of dust-sampling instruments. The results of this study were published in Public Health Hulletin No. 144 entitled "Comparative Tests of Instruments for Determining Atmospheric Dusts." During the course of this study two of the investigators. Dr. L. Greenhurg and G. \Y. Smith, devised a new apparatus called the impinger. In the comparative study the dust collecting efficiency of the impinger was found to lie high, and in addition the method-, offered several advantages over previous methods. After several modifica tions to meet special requirements, this instrument was adopted by the Federal Public Health Service and Rurcatt of Mines as the standard technique for the sampling of dust in air. The instrument lias been used in the study of a number of dust trades, and is the commonly accepted rpethod in use today. 1 . Size of Dust Particles Taken into the Lungs It lias Iicen observed from a study of silicotic lungs that most oi the dust particles that have penetrated into the air sacs arc less than 10 microns in longest dimension Cl micron is l/1000th of a millimeter, or l/2SDflih nf in mrhV It is generally agreed, therefore, that we need not bother with particles larger than 10 microns in measuring the concentration of a dangerous dust. So that you may visualize the size of these small particles consider a 280 ntcsli Dttsl Problem in Induxlrv 41 screen in which the screen openings arc 50 inicvmis. In the absence of a beam of light, an atmosphere containing these tiny particles will apia-ar clear to the naked eye, and therefore is extremely deceptive. Only a powerful microscope can make such particles directly visible. It is necessary, therefore, to make a microscopical examination of the atmosphere to learn how badly polluted it may be. Larger particles such as arc visible to the naked eye arc essentially harmless in the causation of silicosis, as these arc caught by the membranes provided by nature in the nasal and other respiratory passages and are eventually coughed up or eliminated before any damage is dune. When small dust particles are dispersed in air, they arc carried about like smoke and settle out very slowlrr How long such particles will remain suspended in quiet air can be roughly determined from Stake's law. Assuming a round particle to be one micron in diameter, it can he calculated by means of this law that such a particle -will fall only 20.j feet in 2-1 hours. It can lie seen, therefore, that any fine dust dis. persed into the air is not only a momentary hazard but remains in the air for an indefinite period. This fact is often overlooked by workmen, as it is usually assumed that as soon as the (Inst cloud is no longer visible all dust has settled ottt. The term "dusty working place" is only a relative one. Most air, both inside and outside of factories, contains some dust. It is, therefore, necessary to adopt a standard content for the dividing line between slightly dusty and dusty working places. The Wisconsin dust code prcscriltcs a "tentative figure of 15 million countable dust par* tides under 10 microns in longest dimension with free silica content of 55 pc* cent in a cubic foot of air as determined by Public Health Service technique. Variations in ^fearfilica.fontcnt will make proportional inverse changes in Ibis standard." In ac` cordance with this standard The permissible count for practically pure silica would lie 5.250,000 particles. . How Dust Samples are Collected As mentioned previously, the instrument used in collecting the dust samples is that known as the "Impingcr." With this instrument the air to lie sampled is drawn through a glass tttlic and impinged at a high velocity on a glass plate which is im mersed liencath a suitable liquid contained in the collecting flask. The impingcr, therefore, combines the principle oi collecting dust by impingement with a water-washing or bubbling method and so (iohscsscs the advantage; of both principles. The dust is thus trapped and remains in the collecting liquid. Suction is applied to the impingcr hy means of -i steam ejector operated by- compressed air. Where compressed air is not available, a small clcctrically-ojicratccl vacuum pump may he used. The rate of air flow is measured either by means oi a small vacuum gage or an orificc-tvpe flow meter. The entire apparatus is calibrated lieforc use against a standard gas meter, so that a known volume of air piay lie sampled. The rate of sampling is approximately one cubic foot of air |icr minute. The dust-collecting device is placed in close proximity to the breathing level of the workmen involved while performing their respective duties, so that air samples representing actual working conditions may lie obtained. After a sufficient volume of dust-laden air lias Iwen sampled, the collecting liquid is placed ill a suitable container and removed to the laboratory tor the necessary analysis. When the dust sample reaches the lalxiratory, the entire sample is fillcrctl into a clean graduated flask through a 2R0-mcsh screen so that only particles smaller than 50 microns are permitted to pass; particles larger than 50 microns arc not considered 42 Txvcnty-xccond Cont/rcss--National Stifciv Council injurious And Arc. therefore, removed from the sample.' After proper dilution, the contents of the graduated Itaslc arc thoroughly shaken so that a uniform stispension is obtained. and two portions of about one cubic centimeter Arc removed with a pipette to just fill two Scdgwick-Raftcr counting' cells. The cells are allowed to stand at least 20 minutes and the dust particles arc then counted by means of a microscope. . Tlie microscope with* ail Ab!>c condenser is provided with an eyepiece micrometer, a 16-millimeter objective and a 7.X eyepiece. The eyepiece micrometer has a Urge' square engraved on it. and this square :$ divided into HH) squares, one of which is fur ther divided into J5 smaller squares. The proper tulie length of the microscope is determined by calibration with a stage micrometer, so that a side of the large jtquare of the eyepiece covers l millimeter (1,000 microns ). The large square of the eyepiece micrometer, therefore, encloses the dust in an area of one square millimeter, and since the counting cell is one millimeter deep, all the dust suspended in one cubic millimeter of the sample is under the ruled field. All particles visually less than 10 microns in longest diameter in one quarter of the field arc counted at live points on tlie cell, namely, near the lour comers and the center. Two cells of eaclt dust sample are counted and the average of 10 counts is obtained. Control counts arc subtracted from the average sample counts, giving finally, average net counts of tlie ntimlicr of particles which are then calculated in terms of particles per cubic fot of air sampled. . Having determined tlie concentration of dust particles less than 10 microns in diam eter in a given atmosphere, it is also necessary to obtain information regarding the jftincjal co/Tn*osition of the dust before any evaluation of the health hazard can he made. ` In general it may be said that the harmfulness of a quartz containing dust is usually in direct proportion to its frcc-silica (SiOs) content. It is. therefore, neces sary to dhtingmsh !>etwccn "free silica**, that is the silica that occurs as quartz, ami "combined silica**, or the silica that is combined with other elements in the various silicate minerals. It should lie lmrne itt mind, therefore, that the total silica reported iit tin* customary chemical analysis is no measure of the amount of free silica. The quartz content of fine dusts is usually determined by a combination of petrographic and chemical methods. Each dust presents individual problems and no individual technique applies to all dusts regardless of their composition. Those interested in this problem should consult Reprint Xu. 1560 of the Public Health Re ports. Kchrttary 24. 1`kTl. entitled "The Quantitative Determination of Quartz (free silical in Dusts** by Adolph Knopf. Professor of Physical Geology, Yale Universitv, and Consultant. United States Public Health Service. . f Discussion of Dust Problems ''Ztic'/f By DR. LEONARD GREENBURG ^ Yale University, New Haven, Conn. Tlie sjicakcr said in part: On the technical side'at this problem von have liccn presented with twn excellent pa|>crs by Mr. Jones and Dr. Mciter. Then* is little that I should add from this point of view. Perhaps the most valuable contribution that I can make is to present to yon my own personal view oi the broader adminis trative as|iccts of tins problem pained as a result of many years of close contact. In order to do Ibis, let us analyze the problem in its simplest terms.