Document 7RL7GEJ92k66DJ279RkR7gD4j
;. : *
Hr.' C. C; Wilson, Cypsum Division
v
Ceor(l**?clflc - Portland, Oregon
Oypsum J^Lssociation
*01 North Well* Street, Chic**, nilaoU $0606
(312) 72$-$73
June U, 1973
TO THE BOARD OF DIRECTORS Gentlemen;
Re; Asbestos In Joint Treatment Compound
On Wednesday, May 30. 1973. representatives of the Gypsum Association
met with OSHA representatives at the Department of labor, Washington,
D. C. Present were;
.
.
Frank H. Zimmerman Joseph Volk H. B. Carlsen
National Gypsum Company . Nattonal Gypsum Company Gypsum Association
Representing OSHA were;
.
Fred 3lshoff C. R. McClure H. $. Gsbis
-Deputy Administrator -Chief Enforcement Administrator -Industrial Hygienist
The topic under discussion was Section 1910.93 of OSHA regulations (copy attached) pertaining to asbestos. Our concern was with the effect of the regulation on dry-mixing and sanding of joint treatment compound containing asbestos, Y/e raised various questions in regard
to responsibilities of the manufacturers of joint treatment compound * where labeling, monitoring, contractor responsibilit:es, compliance, etc., are affected.
In strict Interpretation of the text of the regulations, a number of questions arise. Although hazard levels for asbestos are stated, some preliminary Investigations indicate that asbestos released in sanding joint treatment may be below OSHA hazard levels. Cn the other hand, preliminary tests indicate mixing of dry joint compound may be above the hazard level.
It was proposed to OSHA that the Gypsum Association would consider sponsoring a monitoring program, conducted by an independent labora tory, to determine and report the dust conditions on job sites under Actual field conditions. The Association program needs to be developed In detail. It should include monitoring of all dust generated In a sanding operation including mica, silica, quartz, talc and total dust.*
Following the development of the program and approval by the Ooard of Directors another meeting should be arranged witn CSK* for their review and comments on Its acceptability.
-
The results of the program will provide the Gypsum Association with
the necessar/'data to develop uniform procedures and guidelines
for users of Joint treatment compounds,
..
The OSHA representatives encouraged the Association to pursue this
test program, and Implied that this might allow a contractor group
to possibly seek variances If they could show that Association pro*
cedures to mix and sand joint compound had been followed. It was
definitely stated that If the proposed program was finalized and
developed, It would certainly show good faith on the part of the
manufacturer and the contractors who adhered to It,
With the approval of the Board the Executive Vice President of the Association can appoint a three or four member Association Task Group
of Individuals knowledgeable In joint treatment compounds and monitor** Ing procedures to develop the program, evaluate Information available, and consider hazards as they relate to OSKA and NIOSH requirements.
This preliminary approach to the asbestos dust hazard In joint treat ment materials results from the Directors1 approval of an investigation of the problem last April, and the suggestion that member companies contribute any accumulated data useful in determining a proper test
program. The interest expressed by OSHA Is encouraging. Hay we have
your reaction to this report at your earliest convenience?
Yours very truly.
HBCjmj Enc, ' cc: Chair?.>en of all Committees
H. 8, Carlsen, Secretary Technical Committee