Document 7RKYN1Rvj8k3Mm91gk2j7ZnpR

October 8, 1962 Nr, John A. Janous Industrial Hygiene Engineer Jones k Laugh1in Steel Corporation 3 Oateway Center Pittsburgh 30, Pennsylvania Dear Nr, Janoust Z an sorry there has been a delay in my reply to your letter of September 26th in which you requested information concern ing our hydrochloric fluid APvdraul ISO. I have been out of town and have just returned to the offloe. I will attempt to answer the questions you raised in the order they appear in your letter. In addition, I am requesting that our fluid engineering experts send you additional data and consents since the flash point of fire resistant fluids is not the sole criteria for determining the laok of fire hasard in the use of these materials. 1. The flash point for Pydreul 150 la 425 7, Cleveland Open Cup. The fire point is 465 7., Cleveland Open Cup. It la my understanding that the flash and fire points at these temperatures are the results of break down of the fluid rather than being the flesh and fire points for the vapors of the fluid itself. Although we do not have oomplete analytical data as to the com position of breakdown products, X would expeot that a major constituent would be carbon swnoxide along with phenolies, aldehydes, COp and water, depending on the degree of breakdown. - fi. I do not believe that it is possible to develop a situa tion where explosion would be a hasard. , 3, AS mentioned in No. 1 above, complete analysis of break down products is not available. This is likewise true where there is more complete thermal decomposition which occurs under conditions such as referred to in your letter. Xn animal toxicity studies where fluids similar DSW 018573 ______ T, . STLCOPCB4005117 Mr. John A. Janous 2- October 8, 1962 to 150 ware decomposed at 1050 and 1250 F., animals aurvlvad axpoauraa which humans would not tolerata be cause of irritation to the eyes and respiratory tract. Analysis of the chamber Indicated the presence of the materials mentioned above. It is true that when the animals were exposed for two or more hours to the de composition products some failed to survive. The presence of none of the above materials was not sufficiently great to have caused fatalities in the animals had anyone of the products been the sole contaminant. To give some idea of the concentration of decomposition products to which the animals were exposed, it was pointed out that the "smoke" was so dense that vision through the chamber atmosphere was limited to about twelve inches. Animals at the rear of the chamber which was two feet in depth could not be seen. In a comparison experiment using petroleum base hydro chloric oils, the incidence of mortalities among the animals was nearly as great as with the Pydraul fluid. In the experiments with the petroleum products, the equipmsnt in the experiment had to be modified to prevent the flames from the decomposition from entering the animal ehamber. 4. Based on a review of the effects on the animals and re ports of humans suffering temporary effects in other instances such as the one you described, symtomatlc medical treatment is all that is recommended. Any medi cation or therapy to releive eye and respiratory tract irritation would be appropriate. 5, I would not expect that any fumes or vapors would develop from the use of Pydraul 150 in motorized equipment. If after reviewing the above comments and those which will be for warded by Mr. Bale Smith you have any questions, please do not hesitate to contact me. Slnoerely, EPWidnw Elmer P. Wheeler Assistant Plreotor Medical Department DSW 018574 STLCOPCB4005118