Document 7R6DdEb7Gaz3p1G9Jd7MZzk9o
TABLE I
SUMMARY OF VCM PERSONNEL DOSIMETRY RESULTS
MARCH 1, 1977 - AUGUST 31, 1977
n
Current Sampling Frequency
Workforce
4
Group
I. YEARLY
1. Maint. Elect. 2. Maint. Machinists 3. Maint. Painter/Carpenters 4. Maint. General Helpers 5. Laboratory Supervisors 6. Vinyl Dryer Lead Operators 7. Compound Supervisors 8. Compound, Dry Blend Workers
No. Samples
5 0 1 1 2 3 5 1
Mean (PPM,VCM)
0.14 -
0.05 0.06 0.18 0.11 0.27 -.13
STD Deviation (PPM,VCM)
'
0.08
-
0.13 0.03 0.32
II. QUARTERLY
1.* Transportation Warehouse Workers 2. Warehouse Workers 3. Maint. Instrument Technicians 4. Maint. Building Attendents S. Safety Personnel 6. Mechanical Engineers 7. Storekeepers ft Stores Supervisor 8. Reactor Lead Operators 9. Vinyl Dryer Supervisors 10. Vinyl Dryer Operators Utilities 11. Maint. Utility Technicians 12. Laboratory Technicians
5 2 2 1 3 4 5 5 7 7 2 6
0.09 0.15 0.11 0.03 0.16 0.12 0.26 0.14 0.26 0.36 0.13 0.20
0.07 0.21 0.04
-
0.06 0.09 0.85 0.11 0.16 0.37 0.08 0.14
III. MONTHLY
1. Yard Supervisor 2. Maint. Supervisors 3. Maint. "A" Mechanics 4. Maint. "B" Mechanics 5. Maint. Helpers 6.* Process Engineers 7. Yard Operators 8. Reactor Supervisors 9. Reactor "A" Operators
p
2 12 12
2 1
9 11 13 12
0.52 0.14 0.19 1.09 0.18
0.09 0.13 0.51 0.22
0.15 0.20 0.22 1.15
-
0.09 0.07 0.93 0.22
2-Sigma Upper Control Limit
(PPM,VCM)
0.29 -
0.44 0.17 0.91
*
0.24 0.56 0.18
-
0.27 0.29 1.95 0.36 0.57 1.11 0.28 0.47
0.81 0.53 0.62 3.38
-
0.27 0.26 2.38 0.66
9
VA^bOO1049911
TABLE I SUMMARY OF VCM DOSIMETRY RESULTS
MARCH 1, 1978 - MAY 31, 1978
Workforce Group
No. Samples
I. Annual Schedule
1. Compound Supervisors 2* Dry Blend Operators 3. Compound Operators 4. Trans. Warehouse Workers
6 5 4 3 18
II. Quarterly Schedule
l Storeroom Supervisor 2. Lab Lead Techs 3. Lab '"A" Techs 4. Warehouse Workers 5. Storekeepers
2 4 9 4 3
22
III. Monthly Schedule
1. Maint. Bldg. Attendants 2. Maint. Util. Techs 3. Maint. Instr. Techs 4. Maint. Painters
Machinist 5. Maint. Electricians 6. Maint. Supervisors 7. Maint. "A" Mechanics 8. Maint. "B" Mechanics 9. Maint. Helpers 10. Yard Operators 11. Yard Supervisor 12. Vinyl Shift Supervisors 13. Vinyl LR Lead Oper. 14. Vinyl LR Operators 15. Vinyl Dryer Lead Oper. 16. Vinyl Dryer Util., Oper.,
Helpers 17. Process Engineers 18. Safety 19. Mechanical Engineers 20. Plant Mgr, Supt. 21. Dev. Lab. Techs. 22. Lab Supervisors
2 11 13
9 10 24 54
8 7 13 4 16 12 23 8
38 15 11 22
6 5 10 321
Mean (PPM,VCM)
0.23 0.12 0.10 0.10
0.15 0.10 0.11 0.15 0.10
0.05 0.33 0.12
0.14 0.09 0.77 0.87 0.19 0.09 1.69 0.08 0.17 0.29 1.77 0.49
0.23 0.11 0.16 0.12 0.35 0.17 0.10
Std. Deviation (PPM,VCM)
2-Sigma Upper Control Unit
(PPM, VCM)
0.07 0.002 0.00 0.00
0.26 0.04 0.10 0.10
0.05 0.00 0.57 0.09 0.00
0.25 0.10 0.23 0.32 0.10
0.05 0.47 0.08
0.13 0.03 2.90 5.38 0.27 0.04 3.26 0.04 0.12 0.44 3.69 1.55
0.35 0.03 0.14 0.10 0.36 0.12 0.00
0.15 1.28 0.29
0.39 0.15 6.58 11.62 0.73 0.16 8.20 0.16 0.41 1.17 9.14 1.59
0.94 0.18 0.43 0.31 1.06 0.40 0.10
VAB.0001049912
f
TABLE I ANALYSIS OF 1979 VCM DOSIMETRY
JOB CLASSIFICATION 1. Vinyl Oper. Superintendent,
Supervisor, Relief Supervisor, Operations Engineer 2. Vinyl Shift Supervisor 3. Chief Leads 4. \fcinyl Lead Operators 5. Vinyl Utilities 6. Yard Supervisor, Operators
7. Vinyl Operators 8. Maintenance Supervisors 9. All Maint. Mechanics, Helpers,
Painters, Utility Techs. 10. Process Mechanical Engineers
11. Safety 12. E I Supervisor Workers 13. Compound Superintendent Supervisors
14. Storeroom Supervisor Workers 15. Lab Supervisors Workers
S X Cr K 19 .20 .21 11
r
20 .30 .21 10
20 1.40 3.09 10
45
.50 1.69
9
12 .23 .29
27 1.63 6.18
4
68 .73 1.21 7
25
.31 .50
4
45 .40 .89 10
0
1
20 4 8 7 19 8 6
7 .07 .12 3 .03 .06 11 .14 .11 7 .10 .22 14 7 .03 .05 15 .13 .24
S No. samples. NOTE: In most cases, for last 6 months of year - in others for entire year if needed to increase sample size.
X = Average (ppm) sample result. 0"= Standard deviation (ppm) K * No. of results greater than the "Action Level" (0.5 ppm) but less than or
equal to the permissable exposure limit (1.0 ppm) - per 100 samples of the
job classification(s). 0 = No. of results greater than 1.0 ppm - per 100 samples of the job classification
VAB.0001049913
*
*N
TABLE I
SUMMARY OF 1981 VCM DOSIMETRY RESULTS*
Job Categories
S
x Standard
Average Deviation
(ppm)
(PPm)
Reactor Operator General Mechanic Chief Operator
87 3.5 17.0
284 3.7
5.6
47 1.5
2.8
Vinyl Operations Engineer
9
Vinyl Shift Supervisor
54
Lead Operator
92
Yard Supervisor
8
Maintenance Helper
37
Instrument Tech.
6
Vinyl Operations Supervisor
2
Dryer Operator
88
Utility Technician
44
Painter-Carpenter-Insulator
11
Maintenance Supervisor
32
Safety Supervisor
1
Yard Operator
49
Lead Warehouse Worker
2
Dryer Utility
45
Lab Technician
12
Lab Lead Technician
3
Mechanical Superintendent
10
Process Engineer
12
Safety Director
1
Receiving Lead
1
Maintenance Superintendent(Mech .)11
Storekeeper
3
Contract Supervisor
1
Vinyl Operations Supt.
1
Lab Supervisor
6
0.4 0.4 0.2 0.4 0.4 0.4 0.6 0.2 0.2 0.3 0.2 0.6 0.2 0.2 0.2 0.1 0.2 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1
0.9 0.9 0.9 0.7 0.7 0.6 0.5 0.4 0.4 0.3
4-
0.2 0 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0 0 0.03 0 0 0 0
'
24 5
26 11
9 2 13 3 17 0 1 0 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .0
Upper Confidence
Limit (x + 2*S)
37.5 15.0
7.2 2.1 2.1 2.0 1.8 1.7 1.6 1.5 1.0 1.0 0.9 0.6 0.6 0.5 0.5 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1
p
0.1
A
m VAB.0001049914
1
A TABLE I (Continued)
Job Categories
No. Samples
S x Standard Average Deviation
*>
Electrician
Compound Operations Supervisor
Compound Operations Supt*
Plant Chemist
Dev. Technician
Maint. Supt. (I & E)
Plant Supt.
Mechanical Engineer
Draftsman
Plant Manager
Compound Shift Supervisor Safety Inspector
#
3 1 1 1 4 1 1 7 4 1 5 1
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0
Upper
Confidence
Limit
(x + 2*S)
i 1^1^
ii ! ii % T 11
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1
* Note: All dosimeters measure concentration without regard to the use of respirators.
VAB.0001049915
i
TABLE VI SUMMARY OF 1980 VCM DOSIMETRY RESULTS
Job Catesories
No. Samples
S
x Standard
Average Deviation
(PPM)
(PPM)
% 1 PPM
Vinyl Operator
131
Mechanical Helper
9
Vinyl Shift Supervisor
54
Vinyl Utility
50
Vinyl Chief Lead
47
Yard Operator
54
Maintenance Supervisor
34
Maintenance Superintendent (I&E) 3
"A" Mechanics
276
"B" Mechanics .
19
Yard Supervisor
10
Utility Tech.
28
Vinyl Operations Engineer
11
Vinyl Lead Operator
88
Casual Laborer
8
Process and Mechanical Engineer 2
Laboratory Lead Tech.
5
Painter/Insulator/Carpenter
9
Instrumentmen & Electricians
18
Maintenance Planner
4
Lab "A" Tech.
11
Storekeeper
3
Compound Shift Supervisor
3
Vinyl Operations Supervisor
6
Mechanical Supt.
6
Lab Shift Supervisor
4
Maintenance Supt. (Mech.)
13
Safety Director, Supv., Inspector 5
Vinyl Operations Supt.
2
Compound Operations Supv., Supt . 2
Receiving Lead
1
Stores Supv.
Quality Control Supv.
1
2.7 2.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0 0 0 0 0 0 0 0 0 0 0
3.6 6.4 1.0 0.9 0.7 1.1 0.7 0.5 2.0 0.4 0.3 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0 0.1 0.1 0.1 0.1 0.1 0.1 0 0
--
-
--
5 11
4 4 6 6 6 0 4 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Upper Confidence
Jiimit (x + 2 X S)
9.9 15.1
2.4 2.2 1.8 2.5 1.7 1.3 4.3 1.0 0.8 0.5 0.5 0.5 0.5 0.3 0.3 0.3 0.3 0.3 0.3 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0 0 0 0 0
VAB.0001049916
i. vat
Aa. Mnoonntthljy,_S--amtp-l-e--s- o-f Otnhee mfoolnlothwlyinsgamjopble gorfouepasc:h employee exposure in each
1. Vinyl Shift Supervisor 2. Chief Operator 3. Lead Operator 4. Reactor Operator 5. Dryer Operator 6. Dryer Utility 7. General Helper 8. Yard Operator 9. Yard Supervisor 10. Vinyl Operations Engineer 11. Vinyl Operations Supervisor 12. Vinyl Operations Superintendent 13. Mechanical Superintendent 14. Maintenance Superintendent CMech./ 15. Maintenance Supervisor (I&E) 16. Maintenance Area Supervisor 17. Utilities Supervisor 18. Maintenance Planner 19. General Mechanic 20. Electrician 21. Instrument Technician 22. Painter-Insulator-Carpenter
23. Utility Technician 24. Maintenance Helper
B. Yearly Samples - One yearly sample from each of the following job groups:
1. Lead Warehouse Worker 2. Lab Lead Technician v 3. Lab Technician 4. Receiving Lead 5. Storekeeper 6. Contract Supervisor 7. Safety Director 8. Safety Supervisor 9. Safety Inspector
10. Proces's Engineer . 11. Lab Shift Supervisor^ 12. Compound Shift Supervisor 13. Compound Operations Supervisor 14. Compound Operations Superintendent
15. Chief Plant Chemist 16. Development Technician
17. Plant Superintendent 18. Mechanical Engineer 19. Draftsman 20. Plant Manager 21. Manufacturing Chemist
4- jet
euMi*"*TM0
ioJi 1
VAB.0001049917