Document 7R3M1wXR71pY20D9xjpg3vkvV
Southwestern Oi Refinery
EXHIBIT- , ;
t* / ih^i f >t i*t KRC-483
Maintenance Project
February 1992
Prepared by:
SWRflAsbestos 3442
_y
SWRf/Asbestos 3443
SWRflAsbestos 3444
SOUTHWESTERN REFINING COMPANY. INC
February 12, 1992
Mr. Charles Spiekerman Texas Air Control Board 1231 Agnes Street, Suite 103 Corpus Christi, Texas 78401 Dear Mr. Spiekerman: Southwestern Refining Company, Inc. (SWRCo) will be removing asbestos containing materials from the Fluidizing Catalyst Cracking Unit I and Crude I during shutdown. SWRCo. made plans for renovation to FCCU I reactor, regenerator and stripper for the current shutdown. Also renovations are planned on pipes, valves and flanges in the FCCU I and Crude I units. In preparation for renovation which requires removal of insulation, it was determined that some material was asbestos. Attached is form ACB-99B "Notification of Demolition and Renovation." The removal project is estimated to take 25 days beginning February 15, 1992. Please contact me at 884-8863, ext. 375 if there are any questions. Sincerely,
Barbara J. Pope Industrial Hygienist BJP/msd BP-92006.LTR
SWRf/Asbestos 3445
UF. i iD'A'-":' OF KERRMr-GCE REFINING CORPORA IH)N
NOTIFICATION OF DEMOLITION AND RENOVATION (continued) ' DESCRIPTION "OF PLANNED DEMOLITION OR/RENOVATTON WORK, END METHODTs"' TO-BE
USED: Flu id i 7. in;.; catalyst, it.iik my Unit 1 I'cr.ova t j on to reactor, rotonorator stripper. Removal on pipes, valves, llangcs that require cutting, .rework, or openipi Crude 1-Removal on pipes, valves, flanges that require cutting rework or opening.
XI, DESCRIPTION OF WORK PRACTICES AND ENGINEERING CONTROLS TO BE USED TO PREVENT EMISSIONS OF ASBESTOS AT THE DEMOLITION AND RENOVATION SITE:
Wet method with complete enclosure and negative air. Also wet method using glov bag on piping.
XII. WASTE TRANSPORTER #1 Name:
Condor Waste Transportation
Address: P.0. Drawer C
City: Sinton
State: Texas
jZip:` 78387-0167
Contact: Johnnie Mae Bosworth WASTE TRANSPORTER #2
Name: N/A
Address:
! Tel: 512-364-4232
City:
State:
Zip:
Contact: XIII. WASTE DISPOSAL SITE
Name: Brown^ne _ perr^s industries
Tel:
Address: sinton Landfills FM 1945 S Country Road 39
city: Sinton
State: iexas
ziP: 78387-0167
Telephone: 512-364-4232
lTDH/TWC Permit No.: H0242 '
XIV. IF DEMOLITION ORDERED BY GOVERNMENT AGENCY, PLEASE IDENTIFY AGENCY BELOW:
Name: N/A
Title:
Authority:
Date of Order (MM/DD/YY):
Date Ordered to Begin (MM/DD/YY):
XV. FOR EMERGENCY RENOVATIONS Date and Hour of Emergency (HH/MM/DD/YY):
"Rib.
Description of the Sudden, Unexpected Event:
I i
Explanation of how the event caused unsafe conditions or would cause equipment 1 damage or an unreasonable financial burden:
XVI.
DESCRIPTION OF PROCEDURES TO BE FOLLOWED IN THE EVENT THAT UNEXPECTED ASBESTOS IS FOUND OR PREVIOUSLY NONFRIABLE ASBESTOS MATERIAL BECOMES CRUMBLED, PULVERIZED, OR REDUCED TO POWDER.
Same as Section XI.
, ,,,,,,,,
SWRf/Asbestos 3446
XVII.
I CERTIFY THAT AN INDIVIDUAL TRAINED IN THE PROVISIONS OF THIS REGULATION (40 CFR PART 61, SUBPART M) WILL BE ON-SITE DURING THE DEMOLITION OR RENOVATION AND EVIDENCE THAT THE REQUIRED TRAINING HAS BEEN ACCOMPLISHED |i BY THIS PERSON WILL BE AVAILABLE FOR INSPECTION DURING NORMAL BUSINESS HOURS. (Required 1 year after promulgation)
Uob Supervisor: TDH Lie. No.:
Robert Esparza
80-2317
`
(Signature of Owner/Operator)
(Date)
XVIII. I CERTIFY THAT THE ABOVE INFORMATION
CORRECTED
>' y\.i' I'lvwf
Sigrfature of/'Qwner/Operator
(Date)
Please Type or Print
ACB-99C (3/1/91)
Operator Project t
NOTIFICATION OF DEMOLITION AND RENOVATION
Postmark Date Received TDH Notified? ' Notification t
I. TYPE OF NOTIFICATION (0=0riginal R=Reviaed C=Canceiled): 0
II. FACILITY INFORMATION (Identify owner, removal contractor, and other
operator)
_______________________ _
OWNER NAME: Southwestern Refining Company, Inc.
Address: P.0. Box 9217
Corpus Christi,
State: Texas
Zip: '8469
Contact: Barbara Pope
Tel: 512-884-8363
REMOVAL CONTRACTOR: Gilman Contracting Company, Inc.
Address: 402 Westchester
TDH Lie. No: 80-2317
City: Corpus Christi
State: Texas
Zip: 78410
Contact: Mark Gottlich
Tel:
OTHER OPERATOR: Northwest Envirocon. Inc.
Address: 16811 El Camino Real. Suite 119. Houston, Texas___7,7.08.8
City: Houston
State:
..Texas
Zip:
.7,2(158
Contact: A1 Mavo
Tel:
713-488-3688
III. IV.
TYPE OF OPERATION (D=Demo 0=0rdered Demo P=Planned):
IS ASBESTOS PRESENT? (Yes/No) YES
R=Renovation
E=EmerRenovation R _______________________________________
V. FACILITY DESCRIPTION (Include building name, number and floor or room #)
Facilitv yomponent: fluidizing Catalyst
-n YQD&rm-{MS\F&AiiLr-/,Cracking Unit I and Crude I
TACB Account: NE-0120-14
Address: SAME
County:
NUECES
City: SAME
State: SAME
Zip:
SAME
Site Location: SAME
Site Tel: SAME
Building Size: N/A
# of Floors:
RLA_
Age in Years: N/A
Present Use: N/A
Prior Use: N/A
VI. PROCEDURE, INCLUDING ANALYTICAL METHOD, IF APPROPRIATE,
THE PRESENCE OF ASBESTOS MATERIAL:
Bulk: Polarized light microscopy
USED TO
DETECT
VII.
1. 2. 3.
Personal and Area Monitoring: Phase Contrast Microscopy
SWRf IAsbestos 3447
APPROXIMATE AMOUNT OF ASBESTOS, INCLUDING:
Nonfriable Asbestos
Material Not
Indicate Unit of
Regulated ACM to be Removed Category I ACM Not Removed
RACM To Be
To Be Removed Measurement Below
Cateaorv II ACM Not Removed Removed Cat I Cat II
UNIT
Pipes
,Jo <o< ' -800'-
LnFt: x
Ln m:
Surface Area
3 //7 -fW-
SaFt: x
Scr m:
Vo1 RACM Off Facilitv Component
CuFt:
Cu m:
2/lT/LAjojnpl ete: 3/10/92!
IX. SCHEDULED DATES DEMO/RENOVATION (MM/DD/YY) Start:
Complete:
Please Type or Print
ACB-99B (3/1/91)
NWE/PROJECT LOG
SWRf/Asbestos 3448
NORTHWEST ENVIROCON , INC SOUTHWESTERN REFINING CO.,INC.
DAILY WORK PRODUCTION WEEKLY REPORT
CAT NO.1 AND CRUDE NO.l
2-24-92 DAY SHIFT-FIXED DECON,AND CLEANED & ABATE ACM ON # 1P2 TURBIN PUMP. 2-24-92 NIGHT SHIFT-PREPWORK ON SKIRT,ABATE SAMPLE LINES # 7,8,9,& POLY TWO SMALL LINE. 2-25-92 DAY SHIFT-PREPWORK & ABATE ON SKIRT,CLEANED UP & FIXED UP ACM FROM 2 EXCHANGERS BY STRUCTURE,CLEANED UP & BAGED UP 18 TURBIN PUMPS COVERS,AND GLOVE BAG 20n LINE BEHIND STRUCTURE ON PIPERACK,ABATE ABOUT 3FT. 2-25-92 NIGHT SHIFT-ABATE SKIRT,& GLOVE BAG SAMPLE # 1 LINE. 2-26-92 DAY SHIFT-GLOVE BAG L POLYED SAMPLE # 19 & 4 6FT.ABATE & POLYED 12FT.AND ABATE SKIRT. 2-26-92 NIGHT SHIFT-ABATE SKIRT AND ABATE 3" LINE SAMPLE # 1. 2-27-92 DAY SHIFT-COMPLETED ABATEMENT & DEMO SKIRT, CLEAN UP Ik ABATE # 2P2P1 TURBIN PUMP LINE 2FT.,AND ABATE SAMPLE # 4 & 5 LINES 7FT.. 2-27-92 NIGHT SHIFT-CLEAN UP & POLY COLUMN BY 2-V-6 EXCHANGER, ABATE 2" LINE ON STRUCTURE ON THE 7TH DECK ABATE & FIX 5FT.AND ABATE SAMPLE # 1 LINE. 2-28-92 DAY SHIFT-ABATE # 2P2P1 PUMP LINE ABOUT 6FT.-COLUMN BY WASTE HEATER BOILER # V-17 CLEAN UP it POLY ABOUT 3FT. SERVICE CONDENSER UNIT-2"LINE ABATE ABOUT 12 FT. SOUTHSIDE UINT PIPE RACK ln LINE ABATE ABOUT 2 FT. PATCH LINES BY THE WASTE HEATER BOILER AND CONTINUE TO POLY SAMPLE # l-3nLINE. 2-28-92 NIGHT SHIFT-ABATE ON PIPE RACK SAMPLE # 1-3"LINE COMPLETED REMOVAL.# K-l BLOWER 4"L1NE ABATE ABOUT 6FT.SERVICE CONDENSDER UINT-2"LINE ABATE 4 ELLBOWS. 2 LINES BY THE POLY REACTORS ABATE ABOUT 6FT.AND SAMPLES # 13 & 14 LINES ABATE ABOUT 18FT,ALS0 PATCH 2 LINES ABOUT 3FT. 2-29-92 DAY SHIFT-ABATE TAG # 66 LINE ABOUT 8FT-CAT # 1. COLUMN BY STRIPERS ON TOP WEST SIDE CLEAN & POLY 3FT. ABATE fc WRAP TAGS # 411,43,& 42 LINES BY TURBIN PUMPS ABOUT 4FT. - ABATE TAG # 56 LINE BY 3-V-7 SOUTH ABOUT 2FT. ABATE SAMPLE # 20 LINE BY 3-V-10 TOWER ABOUT 12FT. ABATE 4" LINE BEHIND CAT # 1 STRUCTURE ON PIPE RACK ABOUT 3FT. - AND ALSO CRUDE UNIT CLEAN UP & POLY LINE BY T2DD ABOUT 3FT. 2-29-92 NIGHT SHIFT-CONTINUE TO ABATE SAMPLE # 1,3"LINE,CAT # 1. ABATE PIPES # 1P15,1P16,&1P17,ABOUT 12FT.,CAT # 1. ABATE PIPES # 1P10,1P5.&1P1,ABOUT 15FT.,CAT # l.ALSO LOADED PIPES INTO DUMPSTER .
SWRf/Asbestos 3449
( Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058*(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: Oov f / ire/-*_Pe f.* i^a hu. ^ xT /
Air Monitoring Tech: y a'' L" d0ue
f"toe/Py * <r, z.
Job No.: 8 0 6 V Date: 3 - IS~
Note: Fill in general comments on routine progress on this project on the above
date. Detail major problems and action taken, injuries, equipment
breakdown, unusual conditions or situations, inspections, hiring or firing
of personnel, and any other occurrence which may affect the project.
This log may be utilized as a legal document.
0)53/0 On
0hfo A /n /aJ / 4A JOCuniv.
Dio50 MecO Loiih Ernest ('z)dn?cJ^s-________________ ____________
0 Vao lAetf (.uHh jn&rbartL thae,, Luis
hi sfrindnl j' fa) b<Lrj-
- ii //nitfnlhiaOoA
( X'/n
m4fJ \Nen+ 4f) hhe. o&hc-kr nran-b4ian.
DMD (ior>Tp/e4pd igh Je-ft/ Onan-kuhc)/?.
c
DQfOO \Mfn-Z' fo
n /here. nrP, /)///<*& iO)H
bfL ct-f. and beA/n ho. /m/cacf Pquipmeni.
fbi-30Sharbdrn hfidind aO. ujhprfi 4-hQ
('.on4racers (yO)/l be, nchec-f/nq YJncf
a/ccr.(^s .-tha-b ..she.__fsJanbs u.s> -be Xe____
Orn Wlb Thai,_________ _______ _________________ ____________________
-/odo
. Maniples 4*-j)p*t and ho a
hnr ha.cn grog oh *}-a7rm/esmH- rab^/
5-DY2/r/Ajay. D________________________________________________________________
mo f.m'e.n /uai)pra./-ttr- -4tn aoitrr.f/*c> /A_n rethsh->t-r.Oo--ft-:...T TO.o/ }-hi?)uP.ri -rn (rtmiTup f)i-51Tt
\\5Q \Htiy -fo r-heci-h nn .^ampie^nneisef
C\ 11^-V op 0nn-Vrue -I'Dr mnrh5 ndmP.s ^
5.5. U
--Signature of^H^onitotiftg^Tech
/Page.
cl of
Hnv 6 9C * MAC >!'VOoVCIVfjrO; 'igiil liv n'l&lrf.vij' log fi.r n<jfi
SWRf/Asbestos 3450
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name:jdt//^,^-/^rrt /k-iOW/i-i Ctu<slnc.. Air Monitoring Tech:^7 rj,^.;c
Job No/:_jjQjLGLDate: <k - tT -
[Z2JD..C,r)n\\oa^ +o se-V ocp eXLtu.
\dT)
e>anr\ples a nri
QcfLpLOCir.K o ^ncinHxffi^p rq+.g
n
73&7D0f^rnmeze>s*t bbAaCc-.Ph oonn,P^'/4e. a >///) resf ot-
eqainnieo A n.,nhaq. wti(7^rne^rt o4--f/Si4^
L/J&rh
7
-4a no paper
iil.3fL iirG.h . -fdr La nc.F) /TOO WenU 4n n',oA n .^arhO/e^Pd,
&P4.
________________ t
__________________________________ ________________
/PPClCd/l4'inuc -Id rio /la.per uJdrhu And
7/cSO Inegin -//) GP.nPr /U/('.,
hOQ chpoh pn prMrPs^ n-f prefi-LOorK
PPH need% ,n
% more: Pd be
OOrru i/p 7fCi______:______________ ,
i *73$ P p4 _/jo/V/ JUas WrYlt/ irJCi S V\/fP.
4..iis(a jft4/dn -s/op, si.bn/L-b tine.
-PPQ PeP i^Ph PoherP^rAjha P PimP Pill
~r/iPV
Pir~)
7)^,/. /ip
'ffPn
r
/W P: ,0O. Crno
, / . / /, /< : ' / ' f` rtrea.
JP'3D
-A` o /4/1Q /[/'.S/S S'//PrlY
/PO p-(-r//rf-: ri. /'
/P/O / ;~f- 3v'/e
Signature/0f7Ir Monitoring Tech
6 90 MAC iirc*?c!$O'O1 mg"t iom* daily oo-aif non
Page
S^Rf/Asbestos 3451
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: JIw/^ sics* (?e mc, ) r*f Air Monitoring Tech: p c f 3<,. p Ro d.*,y ,^2.
Job No.: $OJ_ y Date: 2^- 1 ft ~ 73
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project. This log may be utilized as a legal document.
LbO 1 )r\ -s\-Ye^ o..hecV-i iv^
'-VV-
fo5fi ,/Ae.e-r i ov-\h Ln\s /YWrtdft. Lnsu Ir^'r.o Shop.
An
ioVVh ^hberVOj'inf^n forpm&n
h? C> ' Nf\-ec-Y i ca-\\> ba.rbA.ra 4n di~smss rxJooa-
T r>ver. Y-sc foe eY uTTh
pL
\Klol fpr Tn^idah/)/)
bhr>
'Qoc ^'e.-P ^ mp/es bo-bybo 3, Wfi resu/h
b/lb ~hj Kober-ppKlrfiapX.
fofo/lfofo fo/fo `hzM Marshal'/ A/. W..
/&!< TetMo. /jtJk. bapp/e<,.
'
IIso /'nrr.p/f kr? -MA/br Su/As- _____TT-n___ ///Olhb '&;/)erfaJin,(f Lphedy b/me ipil/-fh&
be reach/ . h-e ref __________ .
r/W We/ib -to ynotbe Vfipresr77b~riaer-tjmrk
HbO V\len-f -bn eAfir-A on ocfn-iborK should be. r?tfd\t nb-f-Pr- lunch. )?JO 'tiepn bn ~aeb damp/es ~rencKI Y/.r7' Qba-fp/ibp/if _______ ' _____' ____ _
IZ---b-b We-_e_-/_-__-_+_V_ pQiICC'hh r/t<D-.Dfx&ipimr,'n/es bbJ / liPb C-ir.4- wtm b<-'beri he replied loHhin nnp- hour
" tpoill he, re Ad\i tbr 'x/fcaa./ irspe.e-hr-n
>fig nature of^^onitotmg^fech.
_
Page, / of
'/
M.w. 6
WAC .voxels V0| 'r.:r:H linr;1,i \f loo'fl'f n.in
SWRf/Asbestos 3452
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name:Souikusti-f em /W^,Viy 0.,lnc, Job No.? bOP V
Air Monitoring Tech:^LLr rj 0lt; Rc c fr.'y ^ e ~z.
Date: --Li--z_Z^
IVorh?
fieAi/i 4f) Ho 'Cappr-ujonh.
1350 hemn -t-oo/n \Ji^ua/ in^p-ecJficn. -------
/4*> B&rin -+/) W-eA
D $ 1 Rh iO-
15DD QlfSprOitd \f\SLUol
1510 Oiamoie,
r> Te.su-> Khfcfci Sr.
l5toC.htcJh on pMer
__________
/CcOO (Loni>n LLt.^o a/o Paper- u)0r.hu---------------
IMP & eAa, 7..<?asripfe's> rea rJp
/'W; \Mtn^-h o/cJn cep ^a/n^.,zfFP/o and thw? oUfn/ /o_'r/O&-C-trVe(--s% h:Q?neQ sample. Q= A> TJc, /POO Mf',A .S rEgse-f Pi/ 0,11/0 /}/Y sa/rno/ef,
-fo nQfir A/\M/Su/a 4P fhP-J-y Mar^ha/I
fAO Con-fm u-e -in do paper-/QorK. lQ'2-c'(LheaA on orcorr<s_><~_c~______________________
iQoO 'P/eJo sjy?-Ofo/rip/es OlncJ Od/j-fra.C'/or tui:// ho oonnp/ePec/ of/o:ooix ypnndoi\l. ...........;.
Zpzppen//7 -/o secure, dr-ea.. onti S'fcO Sj/.tc
!er 'irirboroL hnoc^r /oAert:project -^iAnds.
:zjoooU^;^'.
v
Signature^jeff^Xir Monfterlng Tech.
Pev 6 90 MAC H-oco**Cts^'0; loms-CA'ij' o$-a; mon
Page
of SWRf/Asbestos 3453
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: ik-//^f.* i,>y tiT,, _ Job No.: BOC y
Air Monitoring Tech: ^ r .-7,,,.. R.> d.*, u <z z.
Date: - lcf ~
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project. This log may be utilized as a legal document.
D/od.\ th die, (ifrech in /oiih Aepan-if, n(dd> tednicapdmmp/e .na.m/7g, 'reads!__ PiOP Mtei udih liarhara 'pLnd'fliAPwSdPd Ohoud+hP AAlmp/e r-pAuJds d-rom \/S
mornt/itf
=------------:_____ ^--
... ^
Adm \NeM do tjoorK a.re.(x *pd+ir/. anddn
hpdk 4cd mmp/e.s 4/\ U
(Pit? P'f~
fi/iO Wp/d -bn oheph ori reouJido-t- didA--
domo/pp________
.-
________ ____
MO i dd iOt'-fh iMfdi, do herd (dd- pm.
klhCti nrhtp ptxper t onrh, J, nPdcj, and Set ttm/Je -p=dd.
QoC Chec-h on POomofe, pt-i???p^-ou=>d-p
CPP vUPn-i do r/rP,
iOZjO td)y_ /fVs n i e. A/?^ > Aho 7 d?./ . is
rrer.fnc ld/\vl jyf___v /-
` -_"____'._.._._.._._.._.._.._.................................
1030 hpjH dtp ClDG r/o \/'i5clCl/,_____________ __________
Visucc/ CLpornued andO/inuPr nuh: nicked
top .oo nodesPs, Pd. ZobeH- replied4m.t
-hfiPP /a j/ /7 k/iPdosp-c-ArcPe ctfL/e.r //xnc.h
d> A'
n p
Pl
-Signature of^H^fonitowflgTech.
Page / of z.
Ph.` 6 9C ^AC :! .V CuOill ,VQi rf^ jl.uiy Vx;'aw iron
SWRf/Asbestos 3454
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Namv.Souiku^ s e.m
Co,,Tnc.
Aai:r, uMo. nitoring_ -Tre-c_hi_-..p/T,--,. ;J;
7>J S' ~e
Job No.': f> 0 6 L/ Date: 2- /C?
UoD C.dn-iiru^ -fo c/o paper u)orH.__ ____ ____
/^Z<9 6W^. p'amp /e deen^/M:s Vb fabfLr-r,
-fior ~T(a eraa \l. a ieo Qnd !,oirh..AA -md.r__
hOp fanouj1-Jh~P nrr)^rpf=,s O.A dhe.JO/ih___
/?MO nr^in -tvn ae -l r/ear'o. nc.ee hO/nplee
read\/. ________ __ _____________ _
rLpQ.deA eonipMe dpq 3rd d,,
!3 PiD PiaJhea Up SCmiDIE
OnCi 3Cr
eM P/l. CJitch on'________________ _______________
!3dO MeM oJtamer-ce Phh ( CdA.
~
iMOO (``nn/i.nuc -Mr r/n < ______t*_i_n_ r~h -
I pro \Nen -fa c/he da nn' a /arc -fash* CrCco
-fa Kina ideed -/urn dfM hamoled.
iQ7D wend do pieh op oamo/e^edc,h, add
AM. hj\e; MZin.
______________________________ !
laod'/urn on ea mpiee>_______ ___ ,_ ,, .........
troO^ / err darhara lendik) Anar X OJQ.S
leaving nfh h/Aedto
'KqDO Q'jd s/tc , .
Maniple nncniph* ... Zl--Z
POP ifac h nn S/re,: rheeh on e/oi/e lone. I POP begin -+D do paper coord
HdO dr Op np dGnj/o/ee>- hid), Pd creiAj
he dine -ho r/m<
__ ....5..c..ire.
JB.30 P(i-f oO acrid nmen-f.
iQdd Pm-Mmdnr C'nmOfe:
} hmift.
Signature-efrt^ir Monit^rTng Tech.
Pev 6 90 MAC " ^*c**c:s .vOj n-.g-n <0 mi. Ca'if <oc a:r m-on
Page.
SWRf/Asbestos 3455
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: 5k-1/,,,,.? j -re^
* r,,., i~
Air Monitoring Tech:
jR"<, c/`'*',
Job No.: 8 0 6 V
Date:
7. 0 - a?
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment
breakdown, unusual conditions or situations, inspections, hiring or firing
of personnel, and any other occurrence which may affect the project.
This log may be utilized as a legal document.
________
OM') Ln
ctech in uj;//> ^eauriM
MOO Pieced up Teas begin 7o ^e-7
pum.np__ ready DPhI \iaPr/k1/A1 tce`nfl ^~P-hf/i '/Barbara., rave her resedis
on fajJh nnmole, s b ain samples .
D'h^O Wfnb-fr! mee-b cm-bh
____
Cbl'70 knofa a/ c/ZtLrf /inf,S u)rbh nop, (aeherb
d4____ Lllis .
r>9ro ne.cun -+n aeb snmo/endeacim_______
o Q3 o C () n Pro c bo>n on n b 3 bo r-4- H 6 c a un-o, r> -P
OhdmQr pMYjnp //lberS lO iRCdO `mO: ntede
-bn t)e f/xer/ he Per e bor-b/f p r A) 1/e VrS/S.
df/Vd d e rJbam. a /egs d// -A^a/V e ,ai e s.s age
-.I inbomoed Per n Poor.b bhed.Tosenbr/enb
nb /PeondcUb. -hhCcb oOOr-P Uoe cb/dnb
re.por-b -bo bLnb-e.ri
.................. ..... ..............
mnO Wen-/- 4o r-imeh /r aea//-' 6b//man
das -A'/xec/numm. bbohemb^reoP/nd
Z~~
h/.ni -bn rr //'mo (ajher) dhev CirOL
read............. .......................................... ........................................................................
/d/df
-An no Pape n cqq rJe,
1030 AAnhn (,op/t o T Ciin OCi/Onplo.
Signature of^Owonitotmgrech. hnv E 3C M AC i! .voters ITO. 'ro-l ItvmvC.'j If log a,r fnyn.
/Page
of 2.
SWRf/Asbestos 3456
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name \Souikuy s.i-f am /?.vO/..Vvi Co,..Inc... Air Monitoring TecW C',-r rj,,.,;- Ret L- .'y od ~z.
Job No.': > 0, & L/ Date: Z--___ zo ~ ?
H? o V\leni -h an/o r?.SiU4s -fo BP i
/O/O \M-tni -ho c/iecJO // &//71GS) eras rect dpf pjA///
m /Line/).._____________________
l?J5 (Lsnitnac -m c/c oaoen
___ :___ __ ___
t?MQ </VW bn oeb
/7/W P3, ybo, Pr
ison hid Oin\io hag chech Usk&ndr.Jcvith 6/oi/e.
bay rennnve,
_________ _
/33s' Ccn-/y/i,u<L bo c/o paper~coorb^_______ __
/bOO VVoi-f -to r.hfch on aJove hay -rash and__
OanyP/t, p/j/7 ms -:;______________ __ _________ .
JOIP Lnohea a~f /more, /j/oe^ -r/ia / n-eedsOo
ha. (JbCtiediviOP) b/)\J On barb.
/Sqd ({dD'ffnuP bn bn paper ujpt /s. _________ . 1520 bjenb bn rhp.cJn r?n ybt/& bap bopp,
15^)0 Piched yD' aauon/e.n ~/J3 Abb Pb caePp
pHcuj ma ncib' -Pr) r~ bmcLh heam bo a-e.-AOP/ibe
pLinipp ~re.ac/0
i
iPbO (Ovl-O/nue, 7-/> do Oaner uo orb / 0/10 gti
(a ir .pcinno/O o/p n/mea.
ikco Wen/ 4n pee, }4 C\ilm~rrr
KoiO bi IoiCln PfiOfOv CD \io\Kl
re mrA/ai.
MD Oe-f OT/O-
;(oPQ beb Ph ocse
h/O) Prbed (ajd 5T/0 Pert Pb O.hech on a/cne. hag r.v)prh fPretc -t-1c C. _____________________ _--_ /10/0 \Alen-b bn no ,oaoe.rf.norb . and Ouicur
OP an P/0 S / /-> bo 5 //ofe ^
O-fy \Nen-r -ho nheah an a/a/e baa -taob
00/mar? hop SyrGO ^/di/P naPP/ny find C//fi mC p_
Signature^e^Xir MonfterrThg' Tech.
Page
of 3
Hnv C <hC M AC 11 D'r,--C'% l>'0 rr<;'n; ic/n^sjOrt y OC'^.r r>;n
SWRf/Asbestos 3457
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name:Soutk.>f r.rn /W.Covina.
Air Monitoring Tech:
rj,/v^c/.-.V, ^-2.
Job No.': &Q 6 L/ Date: <L- T~o - C/J
-in dun iQ5dn: P/th tup Sfisnp/es. /gV5 do paper nJnh-----------
tQ&Ouecure, are,<x n fd rr'dr -
Signature^^eff^Tir Monitoring Tech.
Pev 6 90 W/vC H n'c. C5s f>'0;
ioni>- c<hy oc an rx>n
Page 3 of _3
SWRf/Asbestos 3458
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Daily Project Log - Air Monitoring
Project Name:
//^J J 7 C / * fief..
Air Monitoring Tech: C1 / U--
y___ 47* j 77 i
r> ^ e? -2-
Job No.: SoC W Date: 2.- 2. / - ?J
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project.
_______This log may be utilized as a legal document.
loO'O Un Oita P.he,cJh in uj\4h Decun-
'loo fieu\n Vr. ^.orDole-Vf. fir nuly StSmfi Gil des.
450 /(y)\\(6kCbh<(eL, Oaoopp\^ib^ nf r~et>u.|A-S.
~
445 \A/en4 4d Prune mj-V -4-q do qIom^ mj
eJ^e.cJ5 tb-4-. j a/ men needed 4o ^ho.\/e
jQ
i-Hoai fs'-Edr-
>v.-v i ' UU!': - J "_II i i
-----------------------
QOO Wn+ - -<9 cl n n a n a. r u) o r K ,
P45 M/1t - "G eheeih on, e me, Oi'cLseCl up
rnamp .0 4,
f0)Q.O J-de-E fbCirr\p(P^ iiao^Dr^ P4 ,
10.10 Pidmed (.i,o bn4h fvxmp <>.5 P~H j P-b
(Oilman uill Pen-finM-e -Vo Q\(nve h(ZG bt-^4er
T\ upi-Ih. b ee^/i.aIsfT. of-^IH,am ^ _7
57-
in
',AA ujxmfD'
-/ 7
7~7l4
DGs
/oT^ U7 p/ hnoco -/-ha4- (xilmrxnu>i//
C o n -/-// lu G -f-D D /n i/-e ham pAu /, y u rp, P/1Y7
4ha.-r.l- ujq3 eO-i//nG o
plctnL
Oic h> (au 1 nn // e n 0 0 /O -__
do nfi-PAi'fe.
'7QO rOoch. on SJntDO.
r? If) e
AZ2mz an dp.
--^Sig n; of^rtH^nitoriflgTech.
Page. / of 'Z.
6 96 MAC '.vc^cis'.vo; iron levrrioVJ.ii'/ lo^ rnon.
SWRf/Asbestos 3459
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name\Souiku^sCc^.lna.
Air Monitoring Tech: O,-
Red.' ,'cj ie ?-
Job No.: $0 6 V Date: '2-- Z/ -
r\n a rrwted pithed up Ah3 -/^h^Aad^
4ronn !unoh\ Se.4 Ahh,_________________ ___, IZ4D &tlmanJ hrxo.h -frftnn I a neb- Degtio
nro baMf, `oafc-Vv rnec-V\ocu
ZOO Coy zbCMP^d as sdme o4her lm^
--VHSvdr
-Vo VdO CLbaA^d
\ZiO Se-V Sanvple
zHC .Sf-i-V- srm^pizs^Z P-^0 .
^ P C1 oo
MarA-tn .AA .nii^e.re. ^io\ie hnn repoova
\A(Orh p mo c ez
J
IMZo Continue. 4-n do pa perTt^Q.cK
\5CP fearham m-ee.+ ^.o\-Vvt (PU \Malher,
\5ZO \N e n-V 4o -Va no n 4- za nh p I eb P- P 4
P4Q -for bre.a.K
5H0 'Jum ^Qn^olE O O/mP r>n oh&&h>on
0}Id\/Zs bM Pon/P
l(o4Q ('tn 4mid -to do na oer r,dor~K and Oi.v4 fioSfv-H-es in-fo slides.
hiO 'Pav P,P. LQorVs Prdor -ho Pinm-Voo f; i\ -
ro-v-t-ir- e.
VV?\J\ifn4- -h~i Chpr-K nn ft, A. -TQfP^
w /; Or .KpH n p Qr\ mplC-^F TP d
}K?D rrf.m
5f.coA.
,
beaio'ioq To o.m-rupt6ecu/-c.
J
7
PO-to VVen-f- +0 do paper cnnrh r*n Ci
f- nmolefee f. ; U. mg Pf r ftSbh >cO I oho
I Pop cp4-4 ztVz ,
Signature/0f;7Cir Monitoring Tech.
6-90 MAC it
"ig"*
og.aif non
Page _f=n of ^ SWRf/Asbestos 3460
Northwest Envirocon, Inc.
1681TEI Camino Real, Suite 119*Houston, TX 77058*(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: ik v/ ,,,<i j re/ n /tv f. i /9 a-. .27
Air Monitoring Tech: p
R u ds, fr 1/ e z.
Job No.: BOR V Date: 2- '2Z, - /A?
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing
of personnel, .and any other occurrence which may affect the project.
This log may be utilized as a legal document
'd DO iyn
cJoec-.b j n lo\-Va 7>eiuar\\\l- ~_
dhlf; AAi\l-WeerVt Looin-Vrh failnna.p> (Xd
`
-\t) Krv\i f. fYx -f e A\[ me.-eA- \ o o lqVfdp\j ^ Li a 1i ^_____
d.A\. AO141"fbf1 lsV~Tep-.WFtdi <I? rVT TFT 7ToTl~TPT" p7i_ A m(Vf)i%Ima<~_A9._(X' bC\\fFA-A' in 4o
tSQ \Ne rib -do se-V
f ho oJneBs lis4
f/O f
K
Approved ^,T "SaPTOleS
A-h/^ : PNA N\(iiCi'P5 and Noe P(o.
f?D f'} ri v Ae.r \i e .
d\i 9, ha a\, '4tqsK .
M7 Id aa- i n ~\t> g ad si5iis ^ I.Tdd Prann frirjov.
Q X'd C.reuj hfTXKeS "Yarn o-f PS
t2_
QUO P'Sn^-iniAe, -fo n nal\/7i^> adrjy
if)lO V\Irh-I" -4~o ~hu k n o n> jdG.nf^p/QS Pjo f P(o-
/0/^T (Vfw Con4-/nucs -/# r/n dhvt. haG Drasavc.
..... -- Wind -f# do GCkj~)f r~ /oor/s __________________
//Pro \Ajen4}r chac P on a/c\/ baa-iasp. // 7/P Mr A fa (ip . *?r? rrip/fb7d A 3 HP /W Pd.
P/r- (LlTftA) S/lrVi 1//1C GdXp dr r~ /(f J1 CA
lIPO Can-!'/hue - P r/Pt 'IdPLUPr- K< 1/O/^A , /7/W
5^f-npfe..tL..rpnjdjJ,
}77/b> \Ner-f- -k)` (A )nrN - n rPQ: -hr) r5 i- GCirnolTS.
s*
^Signature of
/ "7_~
nitow^Tech.
/Page
of / --S^.
i'l'W . 9' *>AC l.'.'OK'lir/O; J.vm: J05'a.r Hion
SWRf/Asbestos 3461
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name:^ouiki^<= i-f e.m f\&f. s\<j
Air Monitoring Tech: i/Lf rj
Rc t /P.'JW ivt.tj ~Z
Job No.: So 6 L/
Date: ^
tz.r>a .`fr-f Ua.4a8rQ fkh^i flAftlMo-e. P/0.
KdOh) aR aUv?. ha#s 4asfc.
70 Pic fed tip 'ihain A~fk t and e3 ft/\c<m
fokp Wnf -k) nnnk-p, edp/es n-f-oP cesidh,
Qor Edh^rr n h><jcr
_ nedd -to toe.-t
fiher q/oss dfXijn heca gsS h'/h FjhtrrocuO'f.
Hop hey/) -to nu4
C'r<sse-Mts inia Slides.
00 thheh on *\ir,\/e, hos -Rash,.
'10)00 'Tarn off Sample 6 # P.fDZ P-H.
IS?S I urn bac.h in P/0 3P/l'. Oru serve. gfow.
hag ~b(3R>h
ibuOf^oniinLLC fo do paper^orS-.
l(o30nJ\(the copies if- Paper i.onrS and
..ioC V\lp.n4- 4n che/pK nn C\\r\ie. haq.^-ClS,,b..
WsOpijhed Up samples
iMO G>o-V toHh'Uiwto hhiraocia obbui srnd.
qn4- rlen rn.no S vo\0 nperex^orS i/3\-Vh up
\ ooS VmS 'peft-tstyp i onxrr .
I PSO
d\ ri \1
nio
od
n f
)\ h1,
houJer
u O "`R lu
"rd(a mO nO
nrS, Oi Ioo~)hinjj
k) r 4 <s r, ^_________________
QnO (4 i Ima n o r> fnnlp.ie.rl on 4c4V/ no a nn
C iPO r> i A-p
1C1 7 0 .1\P.0,'t trP o -4-14 c n l4 Si4e
Signature/0frtir Monitcn-fhg Tech. Sh* 6-90* V- AC ii.ofO'Cii cj'O rcym.1-Ort'if rj^ non
Page
SWRf/Asbestas 3462
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119*Houston, TX 77058*(713) 488-8688
Daily Project Log - Air Monitoring
Project Name:
* j re,
Air Monitoring Tech:
7
i* c, 47. ^
,
Rdds, c. z.
Job No._: $Cy ^ Date: <- 27/ ~ /
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project.
_______This log may be utilized as a legal document.
hUSOi / h71 3/ -/(L- /rl-f lO/4/l
1-tCtU o\
/5 /n,/i
i,/aAu St'Sn -J-o rr?a.Ae^ Sp/^3 X)A r-Vf/lr/ Vi.VV'/o.
7' V?.S AiieA /<.///) Aa/'Afirti 77U/7 ntr Sa/rip/f r^.3uds
find ZfJ-/hbr.^ Ahftd- pfr.5f-Jinx / pay>//.)/<'C ftft
h//tijZadh.
O /4?5S
A /(:C-
//?6V-<r. 7? rvyt/?f
/5~ 77 X'fU, itlso
Ah fi/UrtL /L^ma.
Jr-t- Aer dn,i/u Aha
//>
d/di ad
uaan5- -j-. >77d t4- ~
Ay'i ,'oQ-r drtfLJ.n A/
c ] /ft3`.
/ nX/c/cid/'d/? Jic // / c~
// TV? <a/<U/f:
Mr',A.
tfiC'P fax in ~h/v* ~5'/)3.h>
J
CP'S Oc-'d/naC 7t 7/7?///7/7 p/yde3 /-/'dsn Ah/atr/cxi/
POOP Meed ioii/) difmdn
TP/j/VV SU 03 r\n3cr
PAroja P^Ate rrr?~r---i-nd P/A~a Mira/idai A,\/\i[c,
QCg.C \kkn4 4r ish nA me aA AwT-aj A A/SU<<a
Cxboui h)f)LU Ahc, aahcAe />ienA u\b mi!/ he c/dne. , '"PUS /ViCci mrbh he,: lion. AheA'merP xtrau. .d/CCLiaa_mAh xihaud Me. cC Ct 'fu7
K;( rC IW-cCm -irf-.td dx-A. Prr-m fAPnian ^ A-irdm
(huA/c 7 rci- Z TTVVv/ hull Xl/jfiiS Ail 3- {\y.fAx,r fxlxr<a\
x-h- OhfticaJ iicC needed -fa hcafc -//7s, C/a A u Ah Ap rho.i (i iaa7 <r>; AAj3>.S]/<t: repin'd AAs
--T
Signature of^jH^onitOHftg-Tech.
Page / of A-
nv" 6. 9C U1 AC .VO<AMs X;iyj itvji'i
loo a.' ron.
SWRf/Asbestos 3463
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Namam Rtf;*;An Co,<slnc..
Air Monitoring Tech:
rj,>L,;r f<\ <. L-.'y -z.
Job No.: PC:.4:,L/. ,,
Date:."7-- 7Z-V - C/J
n nrpdprt 4K\o hpfere, Mieyj ^(.ln 3-Uit
)0:v^ MooPmoArr o mhe,; uxo-l -Vo- \e.\ i
Miranda Kno o ,______________________ __________________________________ t
ADO (4eao -4o Ac, QaOv'r t^.p.rh r\nc\ (?.Emp\e4Q c\
O n\ i_2inM\
\ 2-oc 'MaKo p r,p ,ec\ c;4-
VTbC Q_hecK A-r. OT t.. \4
A 4^
ro on mFFEI
enV -Vo wvee.-V- loon KMraoda. Inn,
rVMP- /Wrc.t torVh MVi vnr\, arl iNir -Vr.-r rekCLSt"
m roOrQ npn.n
u xtr o! o>.>--0
14AO del o, pa U a.hr \xV n. l\(' kk dehie ,4-7
f-mm, 0,i ....... . A. #_'_/_g__g__'_ _______________ __ ___
RI/Y7 Weni -h ee.fmnr)no/ec:,Yh=Y-f\3 fj/hC 4 A/imvt/P-d,
/VM.cA 4/o/7 h/Lrhnra P/me._____________________
M?P IronM 4 lardra K
v^r -W lutfS
AW\i op-pA -\r he ---r-\--ti-X--T-+orl1,
Ml-A? CSfA Avi4h_(Ml
r (M i4i^.rre 7 <xbc;u4
AC1 Ml (mn>.
IP? A'
-Vr, rc\\n p i O OPA iAp onrnpMn
Rl) A ? A/M-/, Pp -OrP>A> mpon Yr, ncc.urp. Ooeft/
l pop- (A9 V lam VK fearbaru Pp.pe. 4-4x4
(!ar4
r\n AMmp hen he p ruAMM cl Ih-e. Ann . MhP. rep
~\0 lOOuA
AMo \~\- Polo pAooO,
Ulf- MWie4 Lius Miranda LneVienx.n r hcr-.t
rf sV r.P Or? vo VW\4 \ ;o/v\l bo inmb \oPpa 14 Yhc
\.o\U
----M----/nA-r--o- o----- f,-1J-f-t -O----t--r---- < Xo'.'oS f,0:4 A -I'hem
4c o'.*- ^ r ^0 pN^mrorr r-r Co. v t p1 Ki1 f-v Kc-L f L/| n
0(\U 'AVr. r-VV\o x ,
Hc4C (\( j i.O Wi iMrin m f
.no ^
Signature^etrAir Monitoring Tech.
Page ? of 4?
Pev. 6-90 MAC n O' G^C!5 jj'O ~i ionv Co'y oo 3if non
3464
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119*Houston, TX 77058*(713) 488-8688
Daily Project Log
Project Name: Project Manager: ELAJjG>('tM-
Job No.:,?0(b.1 ate: ^-2.4-9^
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project.
_______ This log may be utilized as a legal document.
/SCO--/<T
) Q/5 .
//
Yn
xr/i/o/of/sSJZ- sYa/
- Sd/h
,h AY/^S/Y . /?/< stf^Y Y<Dt^<D
CAZ&6SJ
ytJ-ipY sht/
Yh c/fst-V, /Ycxy /^/yf/y.
_________________Afu*> i__ ________________________________' J-9&& A//&J? C'-'f/J) YTqS
S6/'^C J Z7 Atier'
rjb
^ Q-/fY^f<</t/ Ls<s. //Ys cY> ^ -A sts/c/Y^ //s&jc/J'
6t/xT 4
Sfr/Y;.. ^'jkJt?? /&/C ^,/nn^YAy te^rf Ykn Jt/Ow/i/UZ yL<.eJ,
JjL&OO------ S& /vstS S J*)A /Yf?r CtjfJ? ^Y C^J Yo />a^^
------------------------^ e^/o(/GY*4C CaA .f// A/{A /-/7JOtU YH&JL&rf/CG Yusc)
________________ /^s///tsj>tS sSrtyf sY/t&tf sYiac/ /A
*+ 9^/j/ , </&)t
____________ a* J 9^1*1/4-s Y . y sfao
cT CJCGc^ Zft4-uG ctA Ycs*a A'S/tSdc/
,
Ad^/c rfht? Y/-c;c <^UGtstf lf/2/iy *4(/
__________________ is*c., Yke
Z-QZf)
c*a ?)/?,
//Yg
OUSl. cY<E s^i*c/ cm? & ,y/,, /-I4& C^c?
/hjtGS' As/Y& Q'-y YJ'CrUA
Signature of Project MMaannaa<ger flw. 9-90 MAC irvorojecuvoroi mgmt lofm3\daily pro\oa log
/Page,
of
SWRf/Asbestos 3465
Northwest Envirocon, Inc. Daily Project Log
Project Name:
vjj Crsi
Project Manager: EiA)[&Qz
Job No.:^Q (nlDate: 2--? (t-tj 7
____________ A&o A <* ^ TklS'U
if j u.S /
k/C ^c) /-V
Qt&v &Lt!A SoM cZ&<r/ Crf-AJo X) y^r/
7^^ rfjgrf
ok
AMGv* Ai C~s,,6/c <,ALjr/<S1. (&A Zoj?)__________
__________ /f~o/ sJ-mJgcI
2.Q30_________
__________ P' oz~ (AtelMUtfotiJ- V6b-6>9- 5fix' 203
_________ i4T- o3 /UofZ (t-itol* -VJ "~ (T- 7 9 3^ 'Zo'jQ~2/ac
____________ tMg t4*LC^ /j ct*l 1 rJ<h/fA*+ cm / //W
______________________ '/l / -
J rt- 2^o cd (9_________________________
____________________ f-z-.^tss m**z* - vro^tl-r^io
____________________ S?~3 - /LAfrm
</rs-1<-?</5"
>./JQ Cn /rt*A/ 4eL
*C 36
jfvtJcfi&A/A
___________ /Rrt'/b4-\ C^sa/O . 7^/ie tAsU/ /&/t&c4A
/^W'
___________ /?rt hhto/f .
^ dtot
____________A/______________________________________________________________________________
2>2)d U/ajU => /-**Z.l&Z
Z-OC,/C . /~jCK\/(^ ZZsiL lS.y
____________A^> / Oj}*/c/ ^tir/ //rtsc/Cte <& i^Sru/1<yf ^//<z.
?,?r> Ovt^/Z^r sr/c/t/jL /^Ak Z$ $01/
J-fc&y
Jitr
*<&/ **-gj/.________________________________
Z33& Luntsh--.^AuZ d-ZZ t^Z/i^uj /L
ZliE
J&c.*Cu&' t'Cidrjb&J^
/-aC.jL .
?
kZ^r/f/ /
/* aW-J. fa
/f
_____________ sCoTtS yty&rZ# . f'/f&lv-
*Zt)/Z ,57.1
A^c/o/i
A tO-'tXFTV //. j#i*J
^,/F^C'/y srtj/
tf/Od
Sf~ sf&n*xz/& y6 Cy^/1 &,//m*/ KS& AfcMF J-d ^
_, <*?/&0/ r^t/'p'g&Sd/is? /
chests/ -A) rJf/r^t-
/utu; As/Z. /-fts-y A?&j/Ga / r/yy
7%6~!
j4/t^ At. <^C/y) gP
Signature of Project Manager
Rev. 6-90 MAC lf\projecta^q mgrm formsVJajly p^ojea tog
Page,
of SWRflAsbestos 3466
Northwest Envirocon, Inc. Daily Project Log
Project Name:
_______________
Project Manager:
3s
Job No.: ?P CXj) Date:
oaso ft-: I
v^;\\
yA tofl.iiftk.fi VxwO\ CVWltl !r><teh
wV 03(30 TVi.e ^ is,
w^v^a) (D<2.6lO AiLc- ^t\ic,^ w. a-Uigiz. sttAs- o
AnA-p&
___V-V\m<^., \X)i \\ ^
^-v^'\?
^ AO 6CMtr
PxxAc -Wo ^Vt4-jl- w
jpu^p l74e<CqA &((m*gfl7
QtZfH/J (ZohffrtA- Vn/?k-V Wj o vWtiCJb \*a&{0 (^iqha Lug
.cfca___ shufj- /4^J pk Uigv^ -V^ cjletfsgkflCj .-fk'g (LMfc7
kg IqAOjO^-M^u^ t-S) Dvte 0^5- k-o^j UW U^g
'T%FJJZ l<> JHifly l-c-r. *vU?W
yA/CU jpo>V-^Ug
p -tu-S^tr rT^fg csS-Jh^***
(J t/&d (A/&A/ j' g/l J^dp Xo ^yJjiFoX- Juif/J PvfiC' I^Us? &(L&uJ o\/y ~l~<^ _________Jus-uc ^ a/~h&v' PU&y f/i // Af&d A/.//'M?
__________ csis&yj -Jo Qd . lA usj //< s &o&a/ x/ouj* //ouj
_____________ Jyi/tir& IS oAs/l/ As^o i^iiSA/ Cas, /'Hr*'-}
. 'XkfrCjt&U)
d&ny -HiF'rcj'cijpkrt^s nm
4 hmA U
U/ikh
\Mfc iA/ AfLov^A Hi If lA-6w1 ".-I- is kvhul W c-uAi ik
l/\)Hj U/'L^A8j AcdfZu) Q(Lc\*a I2i^Y U^pH LotfvzJHn.ij Am^uu/L
d tfistijGivUopb .
&S&D.--fiv4y Cl&*J t&fd-'r-
tsjo A? Jrt/O sJls&'J Ao /X///
________ $-oy us&5 cn /-hs- /.oo <a <j/- u }A&fV c, a /-
_________ /2oyjf^
// -prcau/ys7if*sV</ oa oc/^
________ S?^<J o^/c/.
dn^t^ffo/c/ Jl&/2~l% A/
____________feoy C'irf'/rf~
rfcl<s^ 2-&nSHi/} *f~t* cj ^
OS'JO
edcruof1 -U/7,,// /Z?5/o / drsfirV/?s?
M>addit*
'<rc/c^&rt// -Alj /'XtA A* jde
s4tl/#fys* 5 ^tyatC./'sfad
ft (JF/toicJ- .
Q&3^____^DiU ta.. C't%rf___ W/lr (doZ/t- jfrkcH>/ (,;jhr'r7 U~vS*v/-
A"(*Aj7_y*^ cj fash**-/ o^'/ //&? Qd>/ zj-,3 /Ai Jr^y________
Signature of Project Manage
Page
of _
Rev 6-90 MAC li\Dro!*c:s`.Droj nngmt forrr.s'-^ajiy proie^ og
SWRf/Asbestos 3467
Northwest Envirocon, Inc. Daily Project Leg
Project Name: 5^vVU . u^-ig-S(-
Project Manager:
fey/iyrrL&:>________
Job No.: Date: 2
Q7c?a UVAl
V." Cn\ 'WV/i-Af cArrC-OvA. V-> VWH? __c\.A-Aj
-Iftgy
ivnl Xk &fU?' OJPitii Vs^tsk Vo ihh
___4-=S ^
ipdf&frLyJCitJC.
^3Q 7A71 5//g~ r^a
(Sl/^^ cyA&bM
nS5 H-O
^
. ^bSizA iadlc rXi4-i/ jWrr-t'i^rt/ cm V-.
___________________ \&\p 5C1 Lt7 j-<j Mo v.u ki?vA wk^l b&CrJ&tl -Lx b<5- 3c/Ucr_
_____________ 'TTi&eG(Mi ififf few r.AfWs ?>//rtbKfvd
--------------------
nf)Q& (Cl/hirfJ4
sIumigJ
wU*./ yla frying goAffr
______ jja d\ A'lj b A-j&g \ 4-Vig #4 *4 iZc^Q- .TKs^h fa s'l&ri
_______________ /b*f OtvG hnAdifA/ 3 />M -Ao 4 ^ t-kF: if^V^/ /bi*(f 7 C-,/p t.-(r kO-iJ ,*t
(3$30 <f'fr(c/&c/ 4hc-
t+llhiz skt/tf-
______________________________A /0O -
&ff(3Q______________
_____________________________set ' /M/4rt/u&/ zU/Z# &?/- ?/- <Z//o
_________________________ 37c -/o 2-_________________________________________________
of00 /2<sisv\,*5 shf iffjG <s/ouOu> . /&>/h <r/2L ______ fl<*t'c+i yW<> 7V^->^ /^-c7 l/Lr** . 1] rf/zcJhtd'/ j </ g/ylZyte/J
j4^ /c.o<tJ#i q/p
/3- 2-<s> o 3fmfr^A
o?Od
3?' 2-0 / - dLorrt&S -
\r -J2. oZ-
0fjo fatoda#
j2oiri leof u /
fkidb bfi& ks/lviTiSel
_____<<p*& CM
f'/? &*'//ifr'**#' `Qc/yi cyt fho/f/eo/Z-__
_____'folk U & /W;
h rj A?/Jrt'Us' fi^o <// l/fisO Aj fa/fz.
___________ / Lo3< A`hh . (filrQ&rv' usi lj /ptsd j>
Cjtfu&fl-Z Jjf-fcAs /faw yy/LCr c/xm3/h -Afre
n/opt t(//?/u/- A /&/> A-j o& A^tg- /D/fOcsd^'^c-
(*. /o3b rffoi&o/o ^i4o___QO&TtB (-y----!--/--s---t-f-&----p---'--- *s
^7
fH(f~nsS\ (r-^ f~ I '-/-- '`(O O'f--x^t^P O-' ( it/O 3f$f*
-7hf^ip ^ioo rtf/ikjt.
efi^/o . 7/?i~t7, ^
^Ua,
B3L
Signature cf Project Manager
/Page.
5~ of
Rev &-90 MAC iroroiec:s'oro< ^gmt *orms'<5ai;y p'Ojec og
SI/VRf/Asbestos 3468
Northwest Envirocon, Inc. Daily Project Log
Project Name:.:
d I'U. uJfe4-
Project Manager: f' IUU i C ^av^^t/cS-
Job No.: &Q Date:,
<r/^~ .<"/}sns&eS 'A
_____________ rt /ftfrf/l/ LM/ // btFc/o/^p___<j &AsJ <570^
&//10
S'rfe G*o /z-g^r^----------------------
Z\^L^
Signature of Project Manager
Rev, 6-90 MAC iroroi*c:s`c>'0| mqmt Jorms'-oaiiy proi&ct pg
SWRf/Asbestos 3469
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058*(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: iS-//> 7cr * f.* i, y Air Monitoring Tech: p c- ' j<.... R
, 27-.Job No.: Date: Z-- z/5 - S?
Note: Fill in general comments on routine progress on this project on the above
date. Detail major problems and action taken, injuries, equipment
breakdown, unusual conditions or situations, inspections, hiring or firing
of personnel, and any other occurrence which may affect the project.
This log may be utilized as a legal document.
iP2X) ' /On 4/-1& Ph?cb> ho i-Oiih ,3ecun 4v -
/035 (SeP iv/Ph Brnp/oP k) discus's nohaB firms
is ihr Ccrrlratihr /s urnr/sina PPaj'.,
/ IDO MrnmB cirr/ir . feeft turPh Strain
(PuJ'irrms rOhoB nr o-f ofidcfirrs ojj/l /k.
be. having -A) go okrBn iud and bar /<.p
M bi(iA/( f{ A
/ and number fiAroDrkers.
nntnci Oreo imrlr.-
1/1AbCmJCpU -fLt, fAtaXn3 uJ/'be, --?h-!t-= P Nn(-. ftu 3 /7(!jUL~
pkKup and 6a* us) ciA a (U-Abrm P-fo
SOYO/pO
J'
IZDO fc/yf evftfth lb ft p.iS . e.r
robotrP MCIM rictm nfiA-rr
?. i<0 Mee+ i a ' ftw fta rham Pope -Yc r isrusS
Sb/Ovft 4b,0 . ncuDer t,oo ris. -H-ft 4 She n P eft s
Prom fe^.nh'an,, coeni ArPnocxAr, (Looks and
C\wir her a -4m*----------------------- 1
, J , _ ,D
_
iiooWM Vo Chechen Af1 MV. cJearux-K
-------- r
rswo Picked lx. o so,pa pie ft i ftWxft \r\ Wsr - ftW \l ooft\ o
ftfrs i n rOn y'OCl rearly -Oft
-Signature of^H^onitojwg^fech.
/Page,
of 2-
Rmv 6 9- ^ AC :',V0*.!i J.'Ui liyr?;: ,'J.riy OC rt.r niyn
SWRf/Asbestos 3470
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project
f\^.A .,-iy
Air Monitoring Tech: 6,rj,,../-
Job No.': b O LJ
Date: '2> -
- 71
ViSL^t on sh\A
13\5 Li Ls Lalkd L-^rnn - -o have. Po.meL me o ~Yn o\ea.n ix.p aoc o rn p fT M. on__
ii-jplOctSciue^ L%// sr.ai-fn/d &k\J
Pipe, Ndrher Sa i/ (0/npanp (iO / co/Ph
La/s dnd fit.<c-/Z? rf.nd Ocn/Occ, 1
Qe rsgn/?^/.
______ ;________ _____ __------------------------------------- T
NOD V le/N u p +o [/Quad /n^pecd/o/O dnd
yn Do NDSa/nipOs -7^NIP - Y 7N
mo
ro.dic.c__ Clo^.
/OOP
i/nu c tL r/n paaen LnorO
i53o Nerd Or e/ieah On Pcuipn/es, enolcmae-.
OlhoL
-//7^/SS.
i030 PicNerJ UlO Pnjpden, O P L p Sidre!
DOcun/e/ a..na OTP'.
7.
IdONeP Pr?/?-?aO m < Nsm LArda nr.
n/e\/, Oar.
iDnO PitKed iun ymiDje, jp. Aid. medur^
CrpuJ
TnZ>0 tui-ih Pore / ? ? an Or lu-0
lloW ON retmoO N/\ d.n p/dve. bar indn.
!OJ/fO 0 h enO n r ^ &. L1/6? -Oryh D____________________
1300 0 6 -/ iOj4h OOl/rianr Pore mon / / enr/nun.
C.rBuj /r
one Fi o3 >~>r: L
/7/.:')")?.-f 0010/1/t/f -QF O A(/Ol r/ lt/e
n/ni/e. ncto.h O/Kh.
lOoF m
PrO) \Neni Oo rff/CF ~H) -~r on Ainae Pc eir.
Signature^eff^T^ir Monitoring Tech
Hfev 6 90 M AC ! S'Ceds ;>'0\ "'C 'onii Cn y OC' an non.
Page
SWRf/Asbestos 3471
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name:Souik^,>i-f am Rtf;*;a> Co. lnc., Job No.':_<.
Air Monitoring Tech: (',; rj,Rc /V.-.T, ^ -z. cs y
Date: 'Z-- ^ - 2
/*750 \Neni 4n check r>n -enc/r^rZ and______
ln\/f bn
Od fVc-h^cl urn Simple Pbdn dn\- t.chdh /Wlxi^
Whed cMwr line,
-fani-Se, nnd 0,0-f
(fb.oll/'4mhcufioiulmoialdnhe.~/df<hColdema&^nup
a round dec on.
[ P-{Q P/e.Ked, txp ^ nopie WfOtb-W__________
1 feyfigJhgd la(6 8arnple,^ p-J4 /
...
iMo Wenf dn ded nikhf d/?'m~*ano/o/e,read/.
W,C!DO0 Wnkf/nni 4-f-nn dndnn-eoeeQd- tw6/trh C(Ad lri/mmaan nErcbbeerd
and me.d.
,,
IWO
-An Sed nOi/Tl ilfC3
Hid '3
7. PO Kfi/
a. bd\~6 d P/o /erannyp,
Signature/0f7\ir Monitoring Te ch.
of --3 SWRf/Asbestos 3472
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Daily Project Log - Air Monitoring
Project Name:
Mu-0-4-
Air Monitoring Tech: &JN\6 6tMTWsCizg^________
Job No.: ffiO (o^ Date: 2-^T-Pr-
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project.
______ This log may be utilized as a legal document.
sz/g~ tf-i-L/yb C'Qz-'tu?
b& gL&VKCj L--tri Vktcz C`A-1 AfL&A- '"^"Lts-y ^a<A
jd la Cr\<j
Its
firl'in dtd ^(\mG
uA L i
A-W?-A
Ob* b 6 . -W b& du
k*.</-/UK* k-f'___________________________________________________________________________ ____________
82-/3 d &/- CmJ-X
u Q,k&t.)c gyr AmA ~V> &
T- pu m p<,\ UJti/I h
4-q cV\&<sl<o/\
__________________________ 'jf kiSt^r .MSP <^&w\failed //
K 411 Al^f? <Ui*\r\Kf.ij G>\c , OA
________________ /lire
X ^&Q(p/g /A/
Cfl Ib-A cJau&i t hffnJ hli-ly s'&Ugj
, edit,^/u^S ds
ba^4:S__________________ DM lap u4-ku- sti'aj /'htSfitf 2 hM?#'
LHhQ.LtJiy'rt/^ tdc fta/A cm & ^)/ c jJ& <&U 8j0,cu-j- Q/UjuJ
tfiJ <.,,!& Jl<Atj/7 >Sl fUd
^
f U/mJ
* /rti<65
c]/zu&9 (Lukhfr/L
_____________ {j,n/\b 0 &- ( ,_______________________;______
22 2c*T> feyfolc. -La L wj-'b W
-l-S .
,T rJt 7,^
A& <i/fy A / JO h 5.6^-1 I wPvV c,rgw
V Wbe >4-
___________ >4vi,\ UmA\ ''fr'ka vA(tA. Vkig hp&lic:
2,2-SO CtJ&a/l' iLj rkrf^/7- civfst&ti-e ,j-a p-wp <>
<!c3QO (jrt /iVU4tV J-od fz
o i\_ $fj6
0^
U.aoK ^ 8tie.
~Z yi?Q
(T bjAC-tC
b QA
/ /'^ csMUJ c^ts/S c/s i/
Signature of Air Monitoring Tech.
Rev 6-9C MAC ll'.nroiAcis ^fo; mgni !o'ms'>ba:ly tog.a.r nx>n
Page___/_ cf SWRf/Asbestos 3473
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name: Air Monitoring Tech: 15&/A
Job No.:^(T4^ Date: Z.-2&-9 2.
(Si rt70() (Trf'rVWn LAs&rvP
r-^^Y
M(~ l-krt-)- J-he^ "f
\\ hr?
\
___ v4 to\AC 4-^>
sM, Ojirrrsfc
<
y//A-?> dhhsiL 7 Ai/r/
bi^
--AS iSQci/V--T&S &>\
f
3 20l>
flay__rtisdLn.J 14- tjil/Ks CMC ti/lg cJ(\,uAi (7, (C/i^u
/.II
i
(ju-/// A*4t/& -Act ^QUj/C ftAG*** c/ztAssV us//*> /9- j&cr/fIF
j4*J/.*y
qM**i
j? . <6-/tj&(///&/
f^/l <E( _____________ ____c~>//A A^ad /,:
ls*s&/c c*/o ts &C t4o
0^3<b &/&/1//tS/9c*/
-Ai <Jg
&17<Jg <
^.?^a ft A a 'A* J- ,j'dA ^hiC r'rffeiA/ /s
- fkzJr-rk LsJk
d*yd
/J>y2. sf/tou^J
<3tJfiQ /Lcib'SaJ' J-ru^ /V /YlAA> ?j,,f fh<' /-AJr-
J-H-BAC -
_______ .cat/A/
[1/i!tfilA-'j /'*/ frit AftA // // o-Ap/7c^//
_________
a3 5c?l)__ jO'jM&d
St? sfo/J
c f x3-iAJrf /)IiJ <. ^/*W~
/g/ yA ^
fifiQO (Q>,^ o^g/t
is'oeJZ.
Arid
c.fiMf? A A
________ Aa-A Aa* i/i-fif /i4 & 7Z' fhB-y Wo~i/iJ /yt .JfT A>
JMB- A<4<
L*JhcAJ +ir\ \j jQ,jj }-kC/r\ us-/l /Zov Uolj~<7 f'l'I'BM .A> fit* f -/Jh*tA
~Th&y/ &n.t7 USSrU Ost o -/ ik 'U
y^' <J A
/ A 6c'AS
f<C X-< ?- -ihC-fiA -/sfoj- -/<j ncjjy<'-/!^ /-yt
vy y?o 'M~ ~s)7d /Tahi-fc)' ')rf/J
4- yt- l( 4-l/ii- hA-js u/no.1 A n i-. L -/-i ] ts
'T'hlr'f A I'-c pjjr h.ilC-'ij' ^f/ix-si} -l-hf'f ric-cjt*
____^/r o-A
Uj\ ,SoV(J
C u -1
c
( Su Signature of Air Monitoring Tech.
Rev. 6-90 MAC ir<>fO<ecrcxoi mgrr* forrmsdaify 109/au mon.
Page.
2=
SWRf/Asbestos 3474
r Northwest Envirocon, Inc.
i l 16811 El Camino Real, Suite 119*Houston, TX 77058*(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: Sou //, j re ^,
Air Monitoring Tech \ ^ of
R o ds, <r (J g 2,
Job No.: $ G kV
Date:
- /O
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project. This log may be utilized as a legal document.
OdyXT /On fsh-hg-' (tKp.o>n ^ in uQvVW ScrJ.y,t.rrV\!
f)(c5D Xe:V i^)4Vi
\~D c\v?>C!
ujy.re.
o mv en X .3X0-0 Q S _________ .__________________
S 10 fte.o'in -4-0 do copper i/jcr'h njnd 033
, Tl
n
Xrp IOoP ooo d
Oh?jQ1 AAxfiX z.o/4-K ParhctOL Xo d 0-30X0 luK^ ft 1 1 no 0 n 3 do o(1 S. o ,0 O r0 \OV *___________________ _
CpXQ VVgo -P ~Vit oqp.aP uj>3'n /-Qi joym fSXdXoOXn
0&?jn Wood 4-e dp OaoPriL^rh i\odl nnrdmX 0 ppipn of reouU-Pd, KAfP.P lo'dh (n/o-fl
H. r~3 n J O.Ao L
0900 \APrX -to xhxcoh on to.3
xno \ OonX -4-n -Vit rr, of camo\e,,-4& PH P.rPuJ.
imo x oOcio on Onn OnnV3rnor-f -
1 nvr~ a.rnG/1 0,0 A0o,rn/Olxd=- PM * 0J5O aoX
i oiXh PWi'a.n uOhaf +ifre ; ',01 ii <0r6_u bc&ox -X~<~ ii .noJo h3 -rej^Nto < Xlo 000/XrX OX \U30
O..n0 'P.ndos'ire oofud n> 0 1 400 .
in *40 0 d' A-' X on naoor- t/onr-H ,
illO \/\lenf -o nixo ' * n -:/2.n^iGE PX
PO
P..CP: u drvC*K43 --On,--- ''jXX .
' -H- 0 ioO/O o
-0) C\ D --- -7 r-r-
p-> n
'-C^'rsfi -.O
-r. nm
------------------------- ..
. ... y* --....--------*--
-Signature of^y^fonilotwg-Tech.
Page. / of
v. 6-9-C MAC ifA,'0>ec!s-.O'Oj Tipm icyms'fla'ly iog'n.r non
SWRf/Asbestos 3475
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name\5ouiki^<>i-tr.rn f\ Air Monitoring Tech:rj,>,,;c RcA.-.'y^e,-
Job No.: SO L/ Date:
r?.oA-\!`_________ .________ ___________________ _____
lZco'\A/fei-n-f -re
^Qryio/es-y^ ih-Th= P-
P-h (I fZxO do\OQ f-vVA
.
Vipy- t ajO fadiOr^lt. hTk
fy-V P^'rA
ipon vVfin-l Pr H. p Oa nejri^n
1 yjzO \hnnh -Hr, p HeeJP nn
ranol .bap
mr,\ P
,0--)- i o\-Vh P_ Pp'ia n on iA)h er^ c P
nP\1 a-hA n b no P om nlp-l'infA a nbcf/Ana
\h\-7f) \ h! f\ h h C P h, hCjn H ,rP .f~ <A /Q / A A. /0 P ft /^ (/ ft
Pftftn -bosf:yS
lpft)9ft (pQi'lvt ;ip -4-n do ^no.pnn i.oorK .
I ('o0 O P i r- K ft ,4 u_Q pp m DhP' ^ P-ft <; /-/j b
Q:nei Ptrn^.d n V~P
on
-Pb O- ZT7
y c 7
('r^/{ j h-P Am n 4m An /Vvo A 'toho "/'P;'Rein
--i--*" '* 1----- "--=-:--:--- ;------------------------- . w ---- --.................. ------------------------f . ---------- "
'./' /
I 7 (9(0 fhfih ! k : l ~7"h To / //ftftn AAft-cf ftp r PC'TPp. / ft
A. n A A P ft A bv;________ ._________ _____________ ,
iStPG /Aft ftA To'Ah pArh hilrnan Aixh-phf
/ nlO -\-M- lnr ---hr, nnhti--^WnnOa---m----o7---h---n--- : M-r; n P' s-'A
P/n A /ft-ft
d/'srjxssed uJhRrh. Am \fq p, 5Vftt/&
/Aftr picjnpd JW) ^anidpn
/,P59 ,
t j / ? n?Qyy ')P/'?. -n- /~ y '
'I O > o;/Joi/"/1 /./"yooA t.. r
f<//o'&/^ OS hep-
hiO') T-/'>r ' O 00/-^n < -L ' V/y .O'
P/T/j
?.r PPP
in^ in k. ! /(.L Ah'
Ih'P'o'lh licn/xxnr n hC(nl Y -'CTi
Signature^eff^ir Mon^oflng Tech.
Tiftv 6 ^0 * MAC il t/'Gf'C'sO'Oi n-kg'n fcyms^o y og a;f rx>n
Page.
SWRf/Asbestos 3476
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name:Cc^Iac., Air Monitoring Tech:d,fiecL-Zy
Job No.': b 0 6 V Date: `7- 2/.a -
IQ.HO Jyt^in~rf) anaJ/5!\s -rrio^ai/^ 3fide
^iPcn DU'-7---(-Y--2--3-> .
rP-J-----6--->-r&ri)C' .'PJ,
T1')------ r ; ,-w -LL'~bzl
Signature/^fXir MontWfng Tech.'
6-90 * MAC H .VOwjC'S f/'O; ng'Ti I O' nil Oa^f og a if non
SWRf/Asbestos 3477
r
\
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: cSpoVkl Air Monitoring Tech:
____________
Job No PC&'
Date:L2r=2^^2.
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project. This log may be utilized as a legal document.,
loc
Tog
ylY)
_______ _____ 4h^j- yves-A 4xs hr? fL* e
.TIif
_
4rit- c^tvfcyi^-v-.
K'Aa s n/&rv
+h
4iJ'fso f'gy ^ (^\r)Uiy
ua Vla/c
To ISU< I L \-
2&&-&%?KT rkg
4<u Q\G I' i wcj /Zs-aJ y -L)
.----------------------------- f-J'lA-jZ'b istfcr* VHg skuAJr TKg C (?A7 K A1' r CM. -K-'O
K| UAt, >4^ct f#f(L RL OjCfrOV w'vU KiUo
*4- MieJ&S
+<J> Utg- L^yo /ifcft k4u(fr cm& H frpK Uwu
U/if/bG
( '/Mf/staS And c\ac ouds/^r
/fl'&rvt'i?e/ SoJ-h
__________________
^ 2coo 2j-/)/0~ & --
^07
yy^/z-
o lot6 t-'P" <9- A/Qtr{radix ,si
- aT- 79 ?<?
n/og'
2 OSD
UJ&L? /-hz
^ / //>
cy/o
dp/'A'Ct / "f A/2jJo nt Cf A~r'fai&AS
-/hgy o^/ // <6c? "7A/Z-Or //
dhlS Job
sTl dlAt/r Qy/f 'dft/Q
cyt //&M/ U&t r7t5T tftsr+y?
J k 'S cr^ $L0Q/Z~ <yf?* <3^dU/ ______________________ fl'40& ^y\ sf/7 Sd/fevf c/odhfdc, ryiyf .
v\fSignature of Air Monitoring Tech.
Page__ j_
of
Rev. 6-98 >7 AC `I C'o.ocis w'o; mg mi forms'da.l,' log air mon
SWRflAsbestos 3478
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name:. Air Monitoring Tech:
GJSfS-4-
______________
Job No.: Date: T> *~Q
--
_________ si'/- Jlc>3D rLojflJ w&tvc/j
^foo -L^P- V-
^r-
a2.<6a& ^4/?o g*t&u>4UAU&g- tySY-JS* 2*s*f~
c5T/^4tc^AJ
e*A" cjUuFrlo^ OUPuJ
IumI^ e7> 4^ Cia^d_____________________________ A-e. Aa^ /^ma ^s^L^ft
~2J2jc=rO
J a rvf-J-i-L
4-e i ciks^/c
_____________________ \p>Q^ L4wl s& Aui> fvhz,- fi^c y h*vt? <.(trt^^~ . u vcA o\(-r M L\o5fc- ol-
z.l/h-s
flg-pUc~ by i^/^y lAiBnib^rL^yo^ or-(- Cr\\/wi^/V^ T1nfiy
:______________________ ftL\\ f\]g&c{ lA- \iV-Vj6- LiintJc__ Iv^sccjs . TT^
u>nrlk. y^rvtof ^(Uik'V.
~2^Qb hoVlgxk vp\\
f Vr.VL LiA uW. LUf.ll c,n lA
~2^t/0C
l^i/pU Vj^ cL^ ti'AwfcQ-' LjJxzfLsiC- ,____________________________
/dt '/b&UJ
.7h&fat'/*&\ C/tJ
/uj!I /S^f // M*fsr y^> lA/Q/Zjfc- /<* falS-
tS'/^^
a/^/U/ 'i^c, M
, {fLcbBr-tJ- ,5m
W
/ W`/c
/-g^cA y^P <T/Jjg'/too* hsiooh
___________________ fx^r,/Jz h*4< h J?g
A -f~/ // oL->
/C*i, <ro-J
______________ /r>'/fPItl-tO Lss/fJ
C&><<; ,/^7G C/aug
/ h^y U'l //J>^
/S,*^ /*-*
<^r $jLe,,*.J .&-*<=/ Sr/z&v tsuj<* /2*ty/ / <M/
f^QKJCt ^ijr yh^/Lg.
o/a&
J-i A g4>
________ ^ jf/vrf/yst'iAflrJ7r-/Z'/- sf--ri r/
4^'/^
s/rdfe_______
^ A &//&/ u/e-/i5 6>-//***&/ <s s//// . TttE CtAtfFMx
A/Jdh
c//// yW
cCxA^^ff /A&/-
/AS Ai^s &<-/ /i/VJx/yArw
/plsj' /-Crf&/Z& f\ /t/0
Of
t: 0 fi^OC^yto?
9i\v uC^JyvcAv^---
Signature of Air Monitoring Tech.
Page,
of .__3^
Rev. S-90 MAC iroro^cts'oroj mgrnt formsNdajfy b^/air mon.
SWRf/Asbestos 3479
Northwest Envirocon, Inc. Daily Project Log
Project Name? Project Manager:^,
Job No Date:C> ---<2--
ycr i/Lrpi<J<ir
Q'h&ofc- // ert/74
^y
yty*/<P (AS&/Z&
Mad'
________ d? .'7fa&y t2a' Jts h-jliLJ-
*4-// Mit? usi+y AAoir^J /I&aJ J-btdt .
/AlfZ#/- ?4
Xs cfartC/h
<5/<^W Ui I , /f At-V/ -A
///*//
/w/Wi/
^U&U CSJ/s/f
/i& LicA /<W <-~t //*?&d /pa /j4
/&Ifo
y /VST/c/er________________
_________________ ______________________________________________
J^A // // O0-/2
USS/M? (rp/sf&f'
A H4s- cAlf&fa** -/'/4Cx tM&</ AOSO
G/thJ&/a-4 cw .J'tnsz/' /*'*!&'
Dr&&
d4f fhJ'yrtja/dr *s/ // HO /&
A*
_______ (2&/teJ lUfctts/ sh^s/wc? /^^
c^gyt^t c&f
____________ _______________________ _______________________________________
60d Cbd/ Cju/ //l /7&J6&/Z' CscsVjZ/C -/-/ifT
</V
____________/'/iG <'JLs(Z'/ ru4n/?' cn//- s2 /i'A^/d" /}tc//l J? O/ /'
________ /J *4/h/
/Jt***/ /^fZ/V/pA A.
</
__________ oy
A ltd A / Sefy'tf s/yc^tUsC
___________ A*$tS` /Mf//$&/
r^a/tj- Jx*JA&' jV/F/cJ-
_________________ g/ufe*________________________________________________________________ 1
(S rf/-/- d </Ar ca Ao'st*________________________________________
Signature of Project Manager
Sev 6-tO MAC ir^rojocts'^roj rngmt forms'-naiiy b'0i<*3 og
Page
SWRf/Asbestos 3480
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Daily Project Log - Air Monitoring
Project Name:
j -fe,-*
Air Monitoring Tech: J} 01 Ho,..
R*
0 <= a
,
Job No.: &C V
Date:
z*7 - 7D
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment
breakdown, unusual conditions or situations, inspections, hiring or firing
of personnel, and any other occurrence which may affect the project.
This log may be utilized as a legal document.
(o^O pn ,.^/7-e Q.hecheel in 7.0M 0epar/dy Io35 MptF 10/-//7 Frnrd/r errseed -7Jhere 4pro0 \, pp e? 4and. (h i (roan c^//dn4..........c....o.....m.--o7k--4r.
endnr,are, , a/sn mee.4 7,0M furs M/range, >
hon \hl?M -bo (pirnnn poo lor meed ujieh fdobtrf and Prtg/i, /<her/ had QUee-F/om GhooJ r?,ir namr/e Feed. 3 ahnuPn- op
*11'Z2J3D) r,hfeee.>.>nn 4-rn eS/A/~/4r (njpr) F~rOo rn /n/irdo ernnoo//rns~ne^
U)irh Edp-rias) (d/mone nrerhanr
7Af) i-\ec\in 4-r
.^nmo/f-r A/1 '6, (ih, )&
padll;S.Sr(?lli AO, .TnP.AiMAcc.,\____ _, ____________ .
i3Q\\l-en-t m-fo e no /orare, +n,ee-e, ednah
needs j-o he cJnn^ 4-0 e dmp/e 4e-tnIr&uTe-
(Cmie ;nn d ddrurnrd ).< )H4 AJlnrh 4m
Gti lepcgn 4 L u/s MUranr/a. ,, 3 Wp
lahp sb(U.oe.f- and a dr uoi-fh A/1rrd
mF~~\ AJhrk4"^./ib<-jiC
X?t nllscuSSPrf 4io
mP_ (Xto .i-V S-am ol i na.
nr mr r dr. poncr
Ci(f: AApe-T Loi-ffi iJhrhri rn ArUnsfrl ohfi'-f. h nC lfifiu re.--`viflrul'
her
ignature of AtHwonitotmg^Te'ch.
/Page
of
Rov &C `/AC i:r/Of*Oi. *vo: rrori lo'ms'ifimy loc-rur non
SWRf/Asbestos 3481
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project NamQ'.Souik^ m am ^-T.aIau
Job No.: b. O.f? V
Air Monitoring Tech: C,~.r
RRtcc.Lir-m y^ec?-z.
Date: 77 , - t~/L7h -~ /C/1
mn \KienO Oo nwn rfauiVs o samples
'-Vo Pni InnQn ICY?^ ~\t .irndci o 4^? <rSQ..mo\PS/Mo( P~0.
Or)h 5e-V mmoles hfte...K oo
dnd-, pg^r... 5>Tjs...'.b-7.
05 PicbZcf <-< p a~T p Keo h u/i-Vh fc .iV'ian
Qjpsu-V u 'Oo. -V V\o-vP toiH"Vh-.vj bZ COCL(\\J bf)C~
Vl SUa
Ipi^QPo Vior\ K6, *-g.olv/P/j C/JV^Ktrs Homing
za1 1 'V )
min
4n~ l )
oa.P rnss^-Hres<w''IA,. f !
I ^ <---*-3
iI zj -fV> o
^(v i/c--'jes1 ./
IZ ZD Cj a i Z ^ *-h)p3> b\/ ~hn I P.~h m -l (s n fl
(rulman iW meadO ~00r visaed. 3i.ud f\p and
pi.C& /,i.pi Oa/npMs
___________ ___ _
)/ "cz-j&scQs Hnemgmm -~kru) rrtioo vv /:it>sLutQa^i l // n/ /k~~o) /seunpO/ //oo' /n/ nt ) fn/ n3`3jv/;r~/(-
1030 /topraved VIOluxJ cvched up mar^off /h\5 _
Qind Of 4 /Qj) 9) , dOoo/in D.*V/l 4p O n OO-pOuJfk-'P-tL,
l3iO fy/ j/?Yi/l ' 0A/Ti n/-eA-erl ~P77 Ono^/,Ao -Oa/? Q/iO
Oen/n Aa , <?e.0 m.p .3a/??n/^ t4>/~ eJeg ^,i/?c:es.
/bb/b
OnryiP/c.0 /)/r> -30 0-0 3 0-/70- ^
! b-/)3 bti/iT'/ri/jO. b/) c/o \yx-/Dr' /Ajhrb and nci-F
oaose-i'fes inbo:3M-tdrr-
i7/I rf'fx.b -f~rjr~
/
i3QQ Went -//?
A /.m ,3rtsri/37i3
$C-/t?.
j-5/5 Ae^in -i-n.. nna A/</V ^o.mo/eS^7 37lb7(7-
1.730 (IpDrnMfl c/ardnC33 >003 /cc - jin-termed
(Oilman ' !7rbu -g 4 i /, /'^ -;
iUOQ 0.: 0 na n loic' -O P-// On Lj lPc C.. O .cld i. t.p (
Oime. hem lOj/j r,4 zD 3P7 nines. __________ / ((Of' fv 7 !(nih 0-,/, l 4 if a re 3- a hn ^ -/ o iron ;n a ~ A/ZZ
Cu n / / 0-4
Signature^j^Air Monfterflng Tech.
Pace ~2- of 3
Rev 6 90 MAC
mg-n icyms-oa'1/ og a mon
SWRf/Asbestos 3482
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name: Souikuj? Co. , Zac. , Job No.: ?PA.L/ Air Monitoring Tech: ifJy fc/g.2>,Date: 7^-- 7.7 - 77
///?55 PiChed iajd
-h- ah-ft,
I'lKO Mttrf
-bo ^hdfjJ h)m S'ktri..
hfiO P hen bed On a!mo. hna fe/i, Oihvc h&fj
h)5h 7s aomp/^-f-er/ uJnnHeno? ' Segin 4.0 da_
hfrt\ mn \/emeh-/.
hoc Con hnaC +n fla.-f CfiSSO-ih6 //l-Z-n S/jhfet
zo \N?M ~h/) O'dk u p
h- P-//, ha I/O
*)LA--/t-rreS
\/!^}aaJ infiOfr-//#/7/La#rsri
/flhfJ Spo/;7 h r< n a A/s/'i ro< -A&-Am/hes
Signature^tffaur Monitoring Tech
Pftv 6-90 MAC i pfc-r-C's o'O; m.-io'ms-CA',|' lug-au non.
Page . '? ~ o'f 3 SWRf/Asbestos 3483
r Northwest Envirocon, Inc. 16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Daily Project Log - Air Monitoring
Air Monitoring Tech
Job No.:
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project. This log may be utilized as a legal document.
&}9C>0
akd&f
W/^/Ta7 '-A cXur^f
d jjJrtcsl- -
(S
6\A ^ \ ^ K y. (j-f.//
^ XLs v? ,, ~fe ^ h-V
"Tonz/c/i/-
// o/to-J-bs /a/C #bouf- 2<3g<rA
_____
Az^ r
cSf/f hi&vf*- J4- Mi jL&a/-. -f/t&p
C-rtf/
^
^ A/ ,
2ob(D P-/-C&62 -A .5g/
ct
r
<
/sis*lucA rfiaf
ba
</A&
oij&'
. PdjbcZ/r, `Ma/dto/ife'
//6^
//P16/C&
s*y Q yp-PSfp Au/~
O
____________ 2-/A9- ?
________________________________
~2~#cts>2-~/?- y
- - <r
''
^xr- 2_rcr
-Jpsi.--Cjiv a-/ tti.Ji/fA 6A sZcf/'^d /-J s/vfxJ',
____________ si/ /till J-
2.-P-6 -^raA& tmZrrt- YbcP -ff/ - s~3 So
&f)6k C!&iM h*fO o-w /Ad -y.(s/4c~ J6l rvu#-.:- /<0W7^*--r
o/()'rr: f Lf4eM
Ai+rsfi r&A //&/%?- Uj%/--tr*. <d--
c''f fpsZ&ys&t' -
r (/hi- op^,P=(,^x ftfr
//'AAAjOs Signature of Air Monitoring Tech
Page / of
Rev. 6-90 MAC UcfOjeciS'proj mgrr* form$'dail/ log'air mom
SWRf/Asbestos 3484
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119*Houston, TX 77058(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: Sow/A
fie f;*.'**
Air Monitoring Tech:trJ-/gt 7^/j 0Js>.'*u,
Job No.: SOPV Date: Z.- Zft - 92
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project. This log may be utilized as a legal document.
cu/eeecJjii pdruf sAhwiPr--Zt fpf f^l3
hptaxpp . ,
.5^~r SeiMo/k ^P-tf Wesws. Por L<ntZh <xir h&
H7o] pe
i*n-PA srnnecti hi tr uP;he.r<--' p7 Jrs' //*/n/' Ln /s*
(Mpour/na z-pne./9 ft/av-e. brtppisiri
-Zc-crn /np
\Zle/)Z -f'o an pa./oer/AJorh
n <i PjU/ Jn>
Nous-Mr?
oJma-/ 3^ri/ey pnpen tJArK.
QZP Nijlhe, copies o-A ^amp/e. r-es>uJ-/s nns/Pave,
Copies io $//man 4-Aarh&.nx..______________________
/OOP Wen-/ A <Lh-ec.A on Sanp/e.S AnxZ 4/di/PL hap
msJs ,meeA lAjiih Marh
IPSO help /IPPpfs ZP/nnCf/n Ao rPO/p Po/i///n,-fon
S` //n^ ! fh/Zman he.&in Ac /Oc/^ /pneA.
iUP nep/n Ao P/cJA pc/l
t/?)0 G)/ZZnrr/-i hrtLPLPS -Ann A-u,mejL, .______________
iiAO Pepin Zo nfn napjennPon/P Anr/ppAp pap
oA 5Grnp)/eP reAetJ.
^~
IZPl'tT Wtn-f Ao PeA Parryj/P.6 pm pe.r&Dn>c*J-
/Z^ O
/o nnrf PA nrPL nn -
fnoO Chech r>n 3/di/e. bPS Zrisn, a./~>r/ nn P re ex
bam/j/p, P/s,
/"'Signature of Rev. 6*00 * MAC irorojecu'Oroj mgm torrmvdaiV t^/ajr rron.
Page / of ^ SWRf/Asbestos 3485
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name: So<, ti,u,c>rrn Gef.*,*-, Cl.JAc
Air Monitoring Tech: Cor
RoJPZZh? z.
Job No.: 8 Pi, l/
Date: Z. -
9J
!3ZO Pichen/ u^n Pamo/e. ^Zt/JZQ? mcP sap sample & P-P> C a----------------------------------------------------------
1330 \Aipn-l Po do Paper tvorh ._____________________________
IPdO fieAtt7 Pa ana. /Pi 5 CX.tr f-jCtSSePpes j Prt'>r>P
i^SeP-________________________ j------------------------------------------------------------------------------------------------
IPPO APech an a/dve. Sag pash arc/ Sdmp/es, Pep (.o/PA Prain aot<J carper need Po.use.
P/epa. ,
ipPo Mflhe. Hap op arorh PhtiPloi//be. Oomp/ePed
aLMs.^eod op pPPPP-
...
........... ...... ....... _Z
lzS Qo^Pr^r Pr> o/n pn.pe.r- (Odr.h OcrdP/Po
nJhP.sh/P poster cuPptp__------------------------------------------r_
fP/O V\/e,nP Pn P/jurn n/P aamP/eP
and
f-p J\',/mm /,5 irhen___ CJuhreroti,
P Pt // /.t ) i // /0 J-~7P Ar~> C'JL^rr~>p 5; /e. Oh.,------------------
}(c3o\MenP Pc -pern on smnp/e.s^ P~P and
hoicJS fin, (P'tlmm n nnPinaro Pp d<r> * hC<$ Pash . fPjsp u)-e.n4 Pn meed SPAPPLaJpod chrm papers , iPOo ioPPIP Cx>m>p/ede.d incAna anP m/nnd/ne HfAmpsPern tnCCnP Pd OJCJs PsuO Samn/D/O. ^P-fP
arrJ cdealh rn Pj/eve baa Pas/s.
hpO (rr-i/nu r Po pin paper tv or is.
._ .
IPZO Hen-i Po Chech nr c/m/e. bar pprdpor
be?.n (Cm oif,Per/Hrd Pidhed rp nCimoJedp.
/P.do Meed tPiPA Pdrnerd plP /rib Pp d/serss
Rev. 6 90 MAC !!'>ojocts'.orci mgru tcxms^Oa'iy tog^a-f mon.
SWRf/Asbestos 3486
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058*(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: Air Monitoring
Job No.
Date:-2-ZxBff7
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project. This log may be utilized as a legal document.
tA ^r oo G/7,
Oy30
A-dsteJc cs-<
'IaU (j-tW=f
rJJUtct yitZrr
U/\ ci4-b(yj (fal/fft*' d&OCi -kitthlSrh
<'Ldo^rfu-
CAjy^J TtVcAJr ia n^S y <jT ha fe-n/
cM^cr
(IsA jjAT^- fl '(tp (b4c(c
UfCs<iJcL<y -J-EU YU & rCod bA
/Llojfal-
-Lr\ j-'h.cr
yrt'&lfc&J-
^ok / 4 / /
e*s/ //
-A
Wd(/
srt t
.____________________________
4Wg(/&A//k* /f/Z&rf-
c<ss//
J?GL__ J44&SI/
J /*tE
/t**t/r Crf
U/Lsr*t_
f Csk/4feg?/P
__ fidn/Zf,. ed?d&-'Am 4;, ft ha pul.
f?Y &-
y
2-COQ
^>00 ~ fl*y ks&SfoStiorf
t(
^WwT-L^rcX. . 1 (O S c^w VVy^-7
VWy^L >^<jA
------------------- rr^. V^vT"
ljOTp. (SLlAcV _ y'TTl <--
_ Aa^_a f T?f\AJVA^i^ Signature of Air Vtonitdmng Tech.
Page, L of
fie*'. 6-9C MAC hO'OfiC'sOfO] mgnt to*,msvda:ly bg.'sir mon.
SWRf/Asbestos 3487
Northwest Envirocon, Inc. Daily Project Log
Project Name:. Project Manager:
I
yb> Qv\.V| ^ W4*\ c^-v. Wyg-
Job No.^kl 0) CjDate:
__ g^A-Af 7-^ tvAV \ofc~
tw -
_'Q_i/K| Vnrp'A-\-Vv^1 ()rvt
V
l(m <A cS^-
Aca.J\
14-fc-vy^._U.fi CUrvJ
Sbi^o .(2a^Y (Suited S^-k^j
W-S U i\- <3-(X \\&{LA*.j
^yycA kg- wCA\ k)^ W-1\ ftmKW
^AW
-W^vySo ^ kL .c^wc- y
^ h g-Ac-
Uj>E^_*U V b/3^J6
rW-V 1-
4-o gji^kmy
<Af2rgt/Jl K fr
_*\-V* v^-4~ *ts. i>-^v^lCiL^ in V-kg- &MHOb
J^rOairt^_iL'i^ ^ -. V c*kai cpA
V- V\ c* J?-(b?XVvt^-Eb>JC7C-
ACXNHA J/U^j (AlJs
L ua ^ -V-Ia S V-
Oc'iwsgv-i/ <j A&vJ*/
Ltiiksv\{X\G t7^i~|L v--JyV'U. i/^-t->i\ ixA- fo baluB . XWbr u> f-Wc?
CrLcr-p-- usta,lcji*.y tA^v -Ltni? jpij^ig tL^kiAc.
c? 2r,fc> _tigiCAi tjjdnJci^Cj i-K
(Laoir\ t-y
Ar'<J
<~fluuig )~ou<J\
ma A- p\*p& shri-fZ tr^. & U uiA Ml r
____________ /C4)s/c/^ o-f AAi> /v^y1
pur//A /gyc 6
----------------------- _____ /dirt<`S -!_______________________________________________
`2Jfc>Q__ Gt /Z&ldJV CtC<?a/ fS ^ ,'ifr c~/
JboA
jj/? >
________
2-.5L30__l^w^K______________________ __
7. __^xAcAc.
A-<^ c.'/v-V-L A-o .sg-V ippvw
i^-i^ J\
___________ (LA *sltgA^J C_t SSg~H-C~-o^ KKi+*fS .0-\
IS cVn\
------------- vA tt L AikuJc r-i/Lx/WV^V L>v>A o t 'V
iS-Zflft SlrtnJ&d /b/f^^m/zs fJUi//, r/W/ sTc-$u&{ ,gjb&ts/'
________->/J
-/h&J-
a////y?is/- /-//cm Aker
Mft/! s /*4-y /4i/t t/ rr/fppe/^ /-fa&vi '- A
CSc-eS><~^ /$^/J A/rt.'ll) t^/z /t,,U^Prf'ff c_//`</t*// uft*d/ <:^S^
o^Q/Z'/C.
O ypO
PA /VA-. A. ,-
'/^ /{Cg'f4 us?&& Q\ i!rvjtfAJ o rt-&<Ju , ( ? g** A
__ J-K g- cs flu-
tAU-g- S 4-\ i\ r /n11 ip
', ^
Signature of Prcjeci Manager
Page Z. .of
Rev. 6-90 MAC ir^rotectS'OfOj p^grr.t forms'oaJy project og
SWRflAsbestos 3488
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name:Q(\i
V (aSrf
Air Monitoring Te cti: rilAlIpH--
Job Nqj^^-'-~7
Date:2223^L
-b'l/1'P 5Lt^ tT
c4~Vi \F(Lek-h&t. kuV&lci? V ctfc>
. i/v. L. i C . Av^.'X < o\4i&(L 2~ 1U Gr
6 <o<3k 11
t^-w d
& V~Q L- C/f^Q 4-0.
oLe^ p ApS^Zs v// o JLil
tCx
LxJ C-fU /- h&dC 4-*-, _
i
clivCOAJ 4-o C&- hvJ~k/(^
J\ A^
Signature of Air Mofiitoring Tech.
Rev. 6 9C VAC 'l.o'o^ctsoro\ mgrn torms^cfaity og/air mon.
Page
SWRflAsbestos 3489
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058*(713) 488-8688
Daily Project Log - Air Monitoring
Project Name: 5Lt.// ^ a j re / * f.
^ r*,, Job No
6
Air Monitoring Tech: p ,y OftJDate: 2-- 2-v ~
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project. This log may be utilized as a legal document.
040 On
s in
^ecicinhO>
(lk'TO /Vtef/ uj'Hh M-rnesO go 4^ As/ oh jjorh Pirn-
'/man Hid.
100
oaoipio rO/imps: rCO-dP______________________
0/D Mee-r pim (hi inan / L^us M tr&nc/a, syWe73a,
'fi/ie^ 4On 4 gi/mcu) neOcO -fc
an,, , ::s
040 iheWtn -ho 6P-4 gamp/gs onpersonaj,
9>fiO Kid p/y/P ha* (Lhfc.h /as/,'
. ,..
#2/0 Vjftfr Oo tnsol./6l4`/a/?
to
L/sl/s t
/ on /as/ <p/ rjiOrMs -bhn 4
uJ\4h
n as done.
----------------------- -........ ".......
rbLO ih&sln 4-q do go-per (,,jo<rKL
O'lD 44zo4 4c (ihpaA dn y/oi/e hay 4as0 an
iyx2r.6___ op..3l' iLQt:^ t - -....
------------- .
-
-
A/ O L-onr/ncce, -bo -Oik cl// /D p&pen c<j a nfo '"<?>? cb
m/i.A-g
o-P
y?/\/\e.-bo
/03D (bcb 'i'J/OA Lu,/s Miranc/a , &i/nnan Dj&S ash
On a
yj
c-FTfCA/l cfeb'tr <LrujSe. an/4
ho -T o bh G>' Obcn4z?rpo4-(lh, .. _
I Df/i Die boa uyp Oamp/es A 3, d~Dt D4-S-
17,0D Se r . san?/j/ea Db. 0/ D-bo , /4b - 7 //fb.
lOZD Dt4 H-Ci nk.h 4-^ '
7
?- a -Signature of^jM^onitoriftg^Tech.
Page / of P
Rffv. 6 9C MAC i!voec?` A'Oi 'rv^rit io< ms'Cta'lf log a>t mom
SWRf/Asbestos 3490
Northwest Envirocon, Inc. Daily Project Log - Air Monitoring
Project Name: Soithuse'jftim Air Monitoring Tech: Oaf
J
Job No.: do by Date: Z- - Z*/- 9J
tttO/S-e&i fjJ i4hi j&trbcurzk. A) cj/S&lSS
penned fLnci h/vo idne^ t.iroiJd 14 -kUSft. 4o do.
On-V'tntA.^ . 4-n do prx.pwr- LOOrh . and
4(0 Ana h/5 to
se-f sa^p/e:
14/<0 C.heaK on ^\d\ie. ba.A 4nje>h)
8dmp/6^>
f4 Loi-i-h B4rcL\r^ on IQ S-eJr <3-P- so-mp/es resujk
/ Dn /nu-i. 4c rio pCA.pe.r' i/inrlA ^nd
(4x4/
roHan -Vio/-N =?hOP.4-,
570/ hfo,.K on ^i/Oi I i I. in i ii i -
IbOQ Ccn-fm^ -be do oapc^roOrK
--------------------------------------------------------------------------
a.nci --iic- paper
tAPOr-K ,
/c'M/T Ah^coh ,to rjr.ue, bar ict<^h bho-A heis been
CompIeAed and pi'da up>
dK-A { PrP) and
/ / O'/ /c'/o
-bo (Jn /OOL&e/~
(Xnoi PiL-l'-f
tas^ed-ks in bo <3//(/e3.___________ _________:
/9>3Q drnesh /in &//& 4e/ c^idd Aim on ujha^r
ha*> hee/)
m pAn/e. haa -/c&s/i eisi/AuJhmA
needs 4e> be tnorMe<d *n <
/dZd oPP ?/V4 ..
___________________________
Rev 6-90* WAC lhT0)6ctsof0| mgni forms'daiiy tog/a.r men.
Page__ O- of 'zSWRf/Asbestos 3491
f
\
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119*Houston, TX 77058*(713) 488-8688
Daily Project Log - Air Monitoring
Project Namei^i^J/iA V (a&Pt
Air Monito ri noTech:
f
Y.
Job No. Date^S^EEZ^
Note: Fill in general comments on routine progress on this project on the above date. Detail major problems and action taken, injuries, equipment breakdown, unusual conditions or situations, inspections, hiring or firing of personnel, and any other occurrence which may affect the project. This log may be utilized as a legal document.
/(Z?0 a* S//-& /?-/ tS'/'/Jf Jo/f CsivsvC OCsfrk
__________ A <>dr/1
____________ <*'//
/2nf
M
V.
rA* >-//Ji,kJ*uS? /-stLtfsrt AH&7?}&
j s- ^/*/y< / z^o/t'/t/ iy>'r//i<fr //f c>/ ^tr~csp///
____________ ^*7-5 j t>s/ /-c^o &sz2$r ____________/SS*//^<s/Ai'?/PrZcSif(i / sTiSt J-' Prrtsl /^<s ^
^
" S;^su/-
& A'k5r cz/z^scy />0jr. /C, M <r
rfyj'sy
StfZi?
Q*>/>/r we^ /<s /^so/Z
a /key
------w(Z- !u ffrkr-Vr~jrCrtu,t>r (Ju-f /ji -I, w--yir y- nr r /f',L--:----------
2/jn
l~v>n\(^ v4- blg^tr
. .......... 4-Vl 6^| . ~ > v.\.\ ^Vn<i7i-
r\~ yv\V ~>p\-<pc?
|p. fvP {LacAi
(/\a f
1/0-lvvV L>vwr, Ijl?A\
Vq^ V aA cr
i-^^i U '-6 2S% d-C^L->
>A Laa t t-jCo d) (p o->Ia\ pCr-
Rev. 6-90 MAC INyofectstroi mgm lorms\daify to^air mort.
SWRf/Asbestos 3492
Northwest Envirocon, Inc. Daily Project Log
Project Name:. Project Manager: &-/Z.A) ItrOx/tn-,
Job No.&^^L--
Date:
~ZSZ3o ~2-3-.l/0
^ g-'u 4- lo. t-^to 4-0 c\ n 3cwt (r
lorvy
HU'La
v^Lv^t-
lAWt-A, ^
P-m
*0-1 \ CL ywGfil
\M
l?i
_______ 23oa
cJte
Cjiaat<
LAJ r\ 1 u Vw-'-/ Cka. S V --&__Lo f* UfjO-lo Hm In* AV\ 0^(1/?.
r M__________________________________ C-,( <VJl~
Sr
________ sals. -p (/ck3
VOlZc*
cjLfjU LumC.M rf'A>< Z>Ut7u/&f L/
t4> q/o o ^(Atc, c^T -/A^TL?
v^efc-<A ___________
c^-/' //
_______________ c,/-yh/z^ S2A 1/
{Sh/'d /x/0x^
os0c> sA^kA?*/ *^t/ jsfc/CJifa#-/'
. Ust^fs*f
siJ nlt&-cA cAA Akr? c/c3</{pJ>^^ kkBu &
&//Ak?
j.A t-k<z. yus/// cAo
S&`
y ,A\ //p^_c> /o At^A /* /&**</
4fj/
QJ v ii <j6 U,<SW^? H \ Ov?Q . (ib.ll SW*-y.JrtM
^og Vai ftu
g)c>N <sS-C dC o fU C,gS
'V
fcF
F^v\^nSfjv^>,
Signature of Project-Manager
Rev 6-SO MAC ir.oroiec:s'>roj mgrr.t forms'-2any yrojea log
of SWRf/Asbestos 3493
SWRf/Asbestos 3494
NORTHWEST ENVIROCON, INC.
CERTIFICATE OF VISUAL INSPECTION
This certification is to be completed by the authorized contractor representative and the Northwest Envirocon on site representative
Site: Southwestern Refinery Company, Inc. 1700 Nueces Bay Blvd. Corpus Christi, Texas
Project Name:
fo/Lssn/j
NWE Project Number: 8064
CONTRACTORS CERTIFICATION The contractor representative certifies that the regulated work area has been visually inspected (all openings have been sealed off with poly including vents, windows, doors, wall .floors, decontamination unit and waste load out) and has found no openings .
Contractor Name:
//n an
j
Contractor Representative:
Authorized /'Signature
Printed Name
Title
NWE REPRESENTATIVE CERTIFICATION The NWE Representative hereby certifies that he/she has accompanied the contractor representative on his visual inspection and verifies that this inspection has been thorough and to the best of his knowledge and belief the contractors above certification is a true and honest one.
Signature
Date J- /$ - L/J
Printed Name Title
SWRf/Asbestos 3495
oUi%, ^Oco^
Northwest Envirocon, Inc. 16811 El Camino Real, Suite 119 Houston, Texas 77058
(713) 488-8688
PUNCH LIST
DATE:
JOB NO.: $Q 6
PROJECT:
J//3,'sus,at# Co/v.-ns />,tViAS.-j /
COMPETENT PERSON: Robes/
_______
PRE-ABATEMENT INSPECTION: POST-ABATEMENT INSPECTION:_______
nso
/ ASe s y -f-h C A /* z *4
3 //e.
- /o ^ ./? <?
1 Xs < t* A S ; sc
-As & *
r 41? t / <
A *4 S S s e S
z
/S-qo #// o/ //g
tis/v* &____ As* / e? -I Ci4S< o/".
Project Administrator
SWRf/Asbestos 3496
NORTHWEST ENVIROCON, INC. CERTIFICATE OF VISUAL INSPECTION
This certification is to be completed by the authorized contractor representative and the Northwest Envirocon on site representative
Site: Southwestern Refinery Company, Inc. 1700 Nueces Bay Blvd. Corpus Christi, Texas
Project Name:
^i
NWE Project Number: 8064
CONTRACTORS CERTIFICATION The contractors representative certifies that he/she has visually inspected the regulated work area (all surfaces including pipes, beams, ledges, equipment, walls, ceiling, floors, decontamination units, and waste load out) and has found no suspected asbestos containing waste, debris, or residue.
NWE REPRESENTATIVE CERTIFICATION The NWE Representative hereby certifies that he/she has accompanied the contractor representative on his visual inspection and verifies that this inspection has been thorough and to the best of his knowledge and belief the contractors above certification is a true and honest one.
Date /'/-
SWRf/Asbestos 3497
Northwest Envirocon, Inc. 16811 El Camino Real, Suite 119 Houston, Texas 77058
(713) 488-8688
DATE: 2-/9 -9 2
jyf
PRO.TECT: C+f 7//^//
JOB NO.:
Ct> /*>/*> * ^/tcv^v'V/'e
COMPETENT PERSON: /fls>4ey/ Bs&Arz#
PRE-ABATEMENT INSPECTION: POST-ABATEMENT INSPECTION: s/
fo VO_______ fto_____ rv*a / * f____ /& a ______ / A_A S
e. < si_ CfiAcss*i si ,r
// j/j s fs A /
ur * ../
JZ
.<i 6 .i-'
ots-*r
tC-a .
Project Administrator
SWRf/Asbestos 3498
NORTHWEST ENVIROCON, INC.
CERTIFICATE OF VISUAL INSPECTION
This certification is to be completed by the authorized contractor representative and the Northwest Envirocon on site representative
Site: Southwestern Refinery Company, Inc. 1700 Nueces Bay Blvd. Corpus Christi, Texas
Project Name:
*/ SA
NWE Project Number: 8064
CONTRACTORS CERTIFICATION The contractor representative certifies that the regulated work area has been visually inspected (all openings have been sealed off with poly including vents, windows, doors, wall .floors, decontamination unit and waste load out) and has found no openings .
Contractor Name: St/znAn J. z\siz /a
Contractor Representative:
__ Date: 2 ~ 2S" 73 e
Printed Name
Title
NWE REPRESENTATIVE CERTIFICATION The NWE Representative hereby certifies that he/she has accompanied the contractor representative on his visual inspection and verifies that this inspection has been thorough and to the best of his knowledge and belief the contractors above certification is a true and honest one.
Signature
Date 2 -XS~^2
Printed Name Title
SWRf/Asbestos 3499
sgS ^oco^
Northwest Envirocon, Inc. 16811 El Camino Real, Suite 119 Houston, Texas 77058
(713) 488-8688
PUNCH LIST
PROTECT:
C-*- /
3^
^
J,,A'/ r -/
COMPETENT PERSON:
DATE: J-2y~92
JOB NO.: cPe & V
si&/os<~, .
r
PRE-ABATEMENT INSPECTION:__ l POST-ABATEMENT INSPECTION:__
/ //s /> >4 ~ L/A- ('.________________
/
-r <l. s'
s' j ,_________
3 -7-^ j # c- f_____ sA s r y
/7><?
Project Administrator
SWRf/Asbestos 3500
NORTHWEST ENVIROCON, INC.
CERTIFICATE OF VISUAL INSPECTION
This certification is to be completed by the authorized contractor representative and the Northwest Envirocon on site representative
Site: Southwestern Refinery Company, Inc. 1700 Nueces Bay Blvd. Corpus Christi, Texas
Proj ect Name: C& / * I __S/r> rt__ /i a
a
NWE Project Number: 8064
CONTRACTORS CERTIFICATION The contractors representative certifies that he/she has visually inspected the regulated work area (all surfaces including pipes, beams, ledges, equipment, walls, ceiling, floors, decontamination units, and waste load out) and has found no suspected asbestos containing waste, debris, or residue.
Contractor NtNaamme:
11 m n n jj. ns'is/mtvn Co, , JLnc.
Contractor Representative:
Date:
^ AA untthhonrriized QS* rigT naiiir^
J?7'
Printed Name
,1 i-ic: rrcf
Title
Supers- l* , 'S & ~
NWE REPRESENTATIVE CERTIFICATION The NWE Representative hereby certifies that he/she has accompanied the contractor representative on his visual inspection and verifies that this inspection has been thorough and to the best of his knowledge and belief the contractors above certification is a true and honest one.
Signature
Date ~ '3 7 - ^ J
Printed Name Title
SWRf/Asbestos 3501
Northwest Envirocon, Inc. 16811 El Camino Real, Suite 119 * Houston, Texas 77058
(713) 488-8688
PUNCHLIST
PROTECT:
*V J/frV ^
COMPETENT PERSON:
C
DATE: 2'27-?J
JOB NO.:
PRE-ABATEMENT INSPECTION:
POST-ABATEMENT INSPECTION:
42
/O -P /?
r r->
S
A? o
A S
y
//
Project Administrator
SWRf/Asbestos 3502
os 3503
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119 ' Houston, Texas 77058 (713) 488-8688
Inspector's Checklist
Inspector: Jgg Lo~;? R.Js.'a 1^2,
<2Date: " /< ~ 92.
Project:.
* /__________________
Location: T -f/4 its & ^
Client: Sou Uses be rn Re Riblny
j -Z~*
ft o be/- -b
Contractor Name and Address: Gif/mks\ Ta iv/a-Tso*1 CTo. Xnc..
---f--t-.-O-------B---o---x------H---O---I-*----/------.-C---o--r,a--u--s------C---J--i/-'-.-t-J--.---f-'j---- 7.----7-~-e-?--/->--?--j---------------
Phone: 57 J - #8V-
Work Area Observations 1. Work area isolated? 2. All openings to work area sealed? 3. Air movement system sealed off? 4. Negative pressure maintained in work area? 5. Warning signs at all entrances/exits? 6. Number of workers in area: V
Yes No Var.
Personal Protective Equipment 7. NIOSH approved respirators? 8. Disposable coveralls? 9. Head covering?
10. Foot/shoe covering? 11. Proper wearing of clothing?
' .....
Yes No Var.
Chanae Room 12. Hangers for street clothes? 13. Shower available on-site? 14. Containment of contaminated water? 15. Airlock to shower? 16. Airlock to inside change room? 17. Airlock to work area? 18. Disposal bin for contaminated protective equipment?
Yes c/
</ </
No Var. SWRf/Asbestos
Inspector's Checklist, page 2
Work- Practices
19. Are wet methods employed?
--
20. EPA recommended wetting agent used?
'
21. Are HEPA filler vacuums used? 22. Stationary items in work area covered and sealed?
23. Are walls and floor covered and sealed?
24. Milage of visqueen used:
6 mils
25. Are disposal bags properly labeled?
26. Are workers wearing protective clothing at all times in work area?
27. Are workers disposing of contaminated clothing?
23. Are respirators worn at all times? 29. Eating, drinking, or smoking in work area?
30. Are workers using the shower?
Yes No Var. l/ _____ _____ tS _____ _____ ^ _____ _____ t/ _____ _____
_____ _____ _____
l/ _____ ____
j/ i/ _____ _____ t/ _____ _____
______ i/ ____ l/ _____ ____
Explain all variances (Var.) in detail in the space below.
Item #
3
f C/
Explanation
i (9
L /*!-,/ feJyt *
Observations:
SWRfJAsbestos 3505
Northwest Envirocon. Inc.
16811 El Camino Real, Suite 119*Houston, TX 77058*(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client
Ause.i/e/^i
Date <? ~ j *)_____ ~
Job Name and # C a /
____________ ______________________________ &Q&1/
WorkArea iV*/ r
a s Time 9-3 O
Monitoring Performed By
--Pee.
----------
Supervisor______
Workers Namefsf 2 /j / <0^
^ 0 ^ T ^ j z? <- v s A *#/.
Employee Documentation Yes......No Variance
Worker Certificate
*0.
Respiratory Protection
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments__________________
Yes No Variance ____________
Pressure Differential Bag Type
Vertical Horizontal Comments________________
Yes No Variance IS'
Pressure Differential Bag Quality Assurance Inspection - Page 1
S\NRf I Asbestos 3506
Rev s 90 MAC If'^yojecs'iyo' mgmt IcxmsVja pr<?si d-fl bag r.sp
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes No Variance X
iZ.
X X x
Pre-Application Work Area Regulaled Signs Posted Material Wetled Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments._____________
Yes No Variance jX
x_______________ jX _X______________
______________ X
Pressure Differential
Bag Application Yes No Variance
All Seams Sealed All Holes Sealed
X_______________ X _____ '
Amended Water Attached
X _____ _____
Vacuum Attached
X _____ _____
Encapsulant Attached Smoke Tested
_____ _____ _______ _____ X
Comments____________________________________________
Pressure Differential Bag Quality Assurance Inspection - Page 2
Rev 6 90 MAC ir^yo^ecLs'^yo;
cxms'^a
SWRf/Asbestos 3507
C'tf bag msp
Equipment and Supplies End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments__________________
Yes No Variance Z______________
________ Z _ Z Z_______________ ________ z. _Z Z______________ Z_______________ z_______________
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments__________________
Yes No Variance _Z
_______________ Z_______________ Z_______________ z______________ Z
z ZL
Z
... ' Pressure Differential Bag Quality Assurance Inspection - Page 3
sWRflAsbestos 3508
Rev. 6-90 MAC ir^'ojecis'p'O) r^"ii fo'ms'^a p-ess M bap r.ip
Decontamination Procedures Yes HEPA Vacuum Entire Body
No Variance
SAo
Protective Clothing Disposed Properly Bagged
^ _____ _____ ^ _____ _____
_______ _
Comments________________________________________________________ _
us" vo Inspection Performed By
1 y i/ t-
^Dale
!
-92
Pressure Differential Bag CXjality Assurance Inspection - Page 4
SWRf/Asbestos 3509
Rev. 5 90 fvLAC ir^xojecis fyoj
lo-^.s'sqa p^ess flbaQ msp
Northwest Envirocon, Inc.
16811 E( Camino Real, Suite 119 Houston, Texas 77058 (713) 488-8688
Inspector's Checklist
Inspector: Jgg Lo^;s-
____________ Date:. 3- /? - 9 a
Project: Cm / ^ /_______________________________________ _________________
Location: S-t# ,'s-
o/<^su,a *0/0.^^ , g--------------------------------------
Client: Sou -f-k uses &rn Re-/'/a Wij__ <Cg. j -7V>C/-------------------------------
Project Foreman: (?obs^Y
___________________________
Contractor Name and Address: GT*<ivfA-t;o*
).ZV)c-
/^<9 ffo* V<77V Corpus Chris-h', , Te/rtJ___ 775 9.62_______
Phone: S~/J ~ tfS1/- W&l_____________________________________________
Work Area Observations 1. Work area isolated? 2. All openings to work area sealed? 3. Air movement system sealed off? 4. Negative pressure maintained in work area? 5. Warning signs at all entrances/exits? 6. Number of workers in area: ^
Yes No Var.
Personal Protective Equipment 7. NIOSH approved respirators? 8. Disposable coveralls? 9. Head covering?
10. Foot/shoe covering? 11. Proper wearing of clothing?
Yes No Var.
_iZ ^____________ /X ^_ </
Chance Room
12. Hangers for street clothes?
iS'
13. Shower available on-site?
6^
14. Containment of contaminated water? 1 5. Airlock to shower?
_____ l/
16. Airlock to inside change room?
^
17. Airlock to work area?
rX
18. Disposal bin for contaminated protective equipment?
Yes NoVar. SWRf/Asbestos 3510
Inspector's Checklist, page 2
V Wcrk Practices
Yes- No Var,
19. Are wet methods employed?
--
- -------- -------
20. EPA recommended wetting agent used?
'
iS -------- -------
21. Are HEPA filter vacuums used?
^ _ -------- -------
22. Stationary items in work area covered and sealed? l/ _ _____ ____
23. Are walls and floor covered and sealed?
_____ ____
24. Milage of visqueen used:
& mils
25. Are disposal bags properly labeled? `
t/ . _____ ____
26. Are workers wearing protective clothing at all times in work area?
l/ _____ ____
27. Are workers disposing of contaminated clothing?
i/ _ _____ ____
23. Are respirators worn at all times? 29. Eating, drinking, or smoking in work area?
t/ _ _____ ____ _____ i/ ____
30. Are workers using the shower?
zX _____ ____
Explain all variances (Var.) in detail in the space below.
Item#
Explanation
__
_j2___ Z Ayr r* S' S'
fO 7^ C /-V // /^Q /uf
Observations:.
SWRf/Asbestos 351]
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client 5oisS/luses fesn
,.ic.
Date 2- Jo
-9P
Job Name ard # ru d
tJnJ X
Work Area 7~? " /3o
4 P.'P*- rAo/t Time
Monitorina Performed Bv /K W. --
a L>Ois tS _
SuDervisor
^otoer-f s*> rfrZrf
06V_________ /J.'OO
R&Jfit3 ue ~L.
Workers Namefsl ^ /j r n c
/ Y the e-f t
Employee Documentation _Yes... - No--Variance-
Worker Certificate
^_____________
Respiratory Protection Yes No Variance
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tesled Comments
Pressure Differential Bag Type
Vertical Horizontal Comments________________
Yes No Variance
Pressure Differential Bag Quality Assurance Inspection - Page 1
SWRf/Asbestos 3512
Rev 6- 90 * f/AC If^yoiecis'O'O) mgmt Icxms'oa pres* b^g r.sp
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes _X
X X X
X
No Variance
Pre-Application
Yes
Work Area Regulated
X
Signs Posted
X-
Material Wetted
_______
Tools Placed in Glove Bag
<X
Plastic Under Work Area
_______
Bottom Seam Reinforced
X
Comments____________________________
No Variance tX
Pressure Differential Bag Application
All Seams Seated All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tesled Comments_______________
Yes
No Variance
//o-f /ICJT
^ r. / /t f-U
SWRf/Asbestos 3513 Pressure Differential Bag Ouslity Assurance Inspection - Page 2
Rev 6 &0 MAC irp'C-ecu'.p'Oj rr^ml fofmsv;a (vtas oM baa insp
Equipment and Supplies Ves No- Variance End Nippers Stitcher Stapler Two Razor Knives Re-wettabie Cloth Duct Tape Nylon Brush Wel/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments__________________
Work Practices
Yes
Adequate Wetting
______
Proper Handling
^
Folding Sharp Ends In
Surface Adequately Cleaned ^
Lock Down Applied Bridging Encapsulant Applied
iS
Tools Removed and Cleaned ^
Pressure Differential
Bag Evacuated
Bagged Properly
;/
Work Area Clean '
_i^L
Comments___________________________
No Variance ' ~ ----
Z' Zsstt -T
... -
_______________ ____
_____ _______
SWRf,'Asbestos 3514
Pressure Differential Bag Quality Assurance Inspection - Page 3
Rev. 6-90 MAC ir^rojtcis'^oj mgnt lorns'ca p'esi difl bag rup
Decontamination Procedures Yes No Variance
HEPA Vacuum Entire Body
^ _____ _____ --
S
Protective Clothing Disposed ^ _____ _____
___________
Properly Bagged
^ _____ _____
_
Comments_________________________________________________________ _____
sffo ----------------- ---------
Inspection Performed By
i/e t* :ty------------ ------ ---
9- ~ j? o
Dale
-92
SWRf(Asbestos 3515 Pressure Difterential Bag Quality Assurance Inspection - Page 4
Rcv. 6 90 WAC ir^KOyecii'f^oj mg mi hy>T.sV;a p'eu 0`N baQ tnsp
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houslon, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client Souhusestem
.ic. Cc; <.____Dale
~ 3-1_______--
Job Name and # C. ru o/e. />,? ; y_______________________ tfO&y
WbrkArea TJ}
/ p;eerAc/c
Time <5*QO
Monitoring Performed By Supervisor ftp bt>. rf
^SpArz/l/
Workers Namefsi - j S o-f c s & ^
^ JO* j Pcf sAc.ei*.
Employee Documentation Worker Certificate
Yes___ No _ Variance.. ____________
Respiratory Protection
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tesled Comments__________________
Yes No Variance ^______________
_____
_____
i/ _____ ______
Pressure Differential Bag Type
Vertical Horizontal Comments________________
_Yes No Variance------^ y
SWRf/Asbestos 3516
Pressure Differential Bag Quality Assurance Inspection - Page 1
Rev & 50 MAC ir^o^cts'^O) mgmt Icyms'-ca
<3>H bag jniD
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes No Variance </ jfc/_
</_
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments_______________
Yes Mo Variance j/
J/ oZ.
,z ____________ ^
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsufant Attached Smoke Tested Comments
Yes No Variance /____________ u/
_____________ j/_ ^
SWRf/Asbestos 3517
Pressure Differential Bag Quality Assurance Inspection - Page 2
Rev. 6 90 MAC ircvojecLs .p'O)
lc*ms\qa p-ess O'tl bag rnp
Equipment and Supplies End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments_________________ _
Yes / _____
No Variance ^ ___ _
^_______________ j/_
y
Work Practices Adequate Wetting
.. Yes No Variance.. _________________
Proper Handling Folding Sharp Ends In
^ ^
Surface Adequately Cleaned _jX
Lock Down Applied Bridging Encapsulant Applied
________________ <y
Tools Removed and Cleaned
Pressure Differential
Bag Evacuated
Bagged Properly
Work Area Clean
Comments__________________
---------------- ----------------- ---
... SWRf/Asbestos 3518
Pressure Differential Bag Quality Assurance Inspection - Page 3 Rev 6-90 MAC lftp<oj*cis\p'oj r'Qnt IcyrnsNca P'ess dirt bag r-.sp
Decontamination Procedures Yes No Variance .________
HEPA Vacuum Entire Body
^ _____ _____ --
J~-
Protective Clothing Disposed tS _____ _____
______________
Properly Bagged
^ _____ _____
___________ ___
Comments_________________;_____________________________________ ___________
------------------- --------- 1 y Inspection Performed By
Z- 2 / Date
-
Pressure Differential Bag Quality Assurance Inspection - Page 4
SWRf/Asbestos 3519
Rev. 6 90 MAC If'^yojocis'tp'oj
KymsVLa jyesi d-fl bag >n$p
Northwest Envirocon,Inc,__
16811 El Camino Real, Suite 119*Houston, TX 77058*(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client
busesDate ~ ^ ~ 92.
Job Marne and # C. r u d c U a VJ?Q WorkArea 7~1 j Q>o, /&r /
_______________________________________ Time ?, O o
Monitoring Performed By -ALW.-~--7.qq_Lq^i.
Supervisor
ft ob c rl
p a -r
----------------
Workers Namefsl
c / a r ^ ^, a?
ij
jtia&T**
Employee Documentation -Yes____No__ Variance___
Worker Certificate
^____________
Respiratory Protection
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments___________________
Yes No Variance l/______________ _____ _____________ j/
^_______________
Pressure Differential Bag Type
Vertical Horizontal Comments________________
Yes No Variance
SWRflAsbestos 3520
Pressure Differential Bag Quality Assurance Inspection - Page 1
Rev. &-90 * MAC ir^yojec'-s'iKO- rrvjmt tcyms'oa prew a.fl
tnsp
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes j/
No Variance - -
________________ jX
yT_
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments
Yes No Variance _t/
i/ _______________^
_______________ _______________
s^L _ ___
Pressure Differential
Bag Application Yes No Variance
All Seams Sealed All Holes Sealed
l/
Amended Water Attached
s'
Vacuum Attached Encapsulant Attached Smoke Tested
s' s'
s'
Comments__________________
* / / / * e S
SWRf/Asbestos 3521
Pressure Differential Bag Qualify Assurance Inspection - Page 2
Rt-v 6 5<3 MAC ir.oo*ctf',p'0| rrgmt to'msca
O'H ba? ms?
Equipment and Supplies- Yes
End Nippers
Stitcher Stapler
&
Two Razor Knives
1/
Re-wettable Cloth
Duct Tape
^
Nylon Brush
______
Wet/Dry HEPA Vacuum
l/
Scotch Pad
Plastic Baggies
-HtL.
Barrier Tape (Asbestos)
Comments___________________________
No Variance
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied
Yes
.y
^ l/ ^
Tools Removed and Cleaned ^
Pressure Differential
Bag Evacuated
iS
Bagged Properly
Work Area Clean
Comments___________________________
No Variance
____
--
f-f* V- /'/ a
SWRf/Asbestos 3522
Pressure Differential Bag Quality Assurance Inspection - Page 3
Rev.
MAC
rvgm fcyms'ca pew difl fc>ag rv&p
Decontamination Procedures Yes No Variance
HEPA Vacuum Entire Body
^ _____ _____
Protective Clothing Disposed ^ _____ _____
Properly Bagged
_____ _____
Comments_______________ __________________________
S X o & s' &ts
s o------------^- ------- * *<r--i-/-e---C----------
Inspection Performed By
<2. - 2 l
Date
-93
_ SWRf/Asbestos 3523
Pressure Differential Bag Quality Assurance Inspection - Page 4
Rev. 6-90 * MAC INyotecis'iyoj mgnr. tty'T.s\ca
fl-ft ba^ nsp
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119*Houston, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client Job Name and#
y Dale___ 2_z___ ^ --z.22. ** /____________ ._____________________________ tfOA1/
Work Area / - P - 2 Time / V.'/S______________________________
Monitoring Performed By_ fi/.W.f - Jae Lcns .i___--
Supervisor__ ersts t_
Workers Namefsl
r^
^___________________________________ __
Employee Documentation Worker Certificate
Yes
No Variance
Respiratory Protection Yes No Variance
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments__________________
Pressure Differential Bag Type
Vertical Horizontal Comments
Yes No Variance
Pressure Differential Bag Quality Assurance Inspection - Page 1
SWRf/Asbestos 3524
Rev. 6-90 * MAC ir,projecU v^O; nvgml torms'oa
O.tl bag Vnp
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes jX
No Variance
iZ.
________________
i/_
(X
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Undr Work Area Bottom Seam Reinforced Comments
Yes No Variance </ 1/
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments___________________
No Variance
SWRf/Asbestos 3525
Pressure Differential Bag Quality Assurance Inspection - Page 2
Rev 6 90 * MAC ir^yojecis'^oj rr-jmi fcvms'^a pess O'H bag
r Equipment and* Supplies Yes No Variance
End Nippers Stitcher Stapler
i/
^7_
Two Razor Knives
Re-wettable Cloth
Duct Tape
Nylon Brush
Wet/Dry HEPA Vacuum
lS
Scotch Pad
Plastic Baggies
Z.
Barrier Tape (Asbestos)
iZ
Comments.
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends in Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments__________________
jZ
zl
jZ jZz
No Variance
SWRf/Asbestos 3526
Pressure Differential Bag Quality Assurance Inspection - Page 3
Rev 6-90 WAC irp'Oj*cis\p'oJ
Icyms^a pew ditl bag hsp
Decontamination Procedures Ves No Variance
HEPA Vacuum Entire Body
iX _____ _____ __
Protective Clothing Disposed Properly Bagged
^ _____ _____
___________ _
^ _____ _____ _________________
Comments____________________________________________________________
Q ts 'f
Of O*
1
>
1
n il
svo Inspection Performed By
c. ise-t--
Date
SWRf/Asbestos 3527
Pressure Differential Bag Quality Assurance Inspection - Page 4
Rev. 6-90 MAC irp'-oyeciVO'Oj
tcyr.s'ca yen bag >r'Sp
Northwest Envirocon, Inc.
16811 El Camino Real, Suile 119*Houslon, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client !>ots-/Ai~'Cs/-e.m
Cor2~A^. Dale 3. -
H ~ 9 =1
Job Name and # >tLov
^ ^ c *a\ >a,u; h-_______________ J?0
Work Area Ca-V -it- Time____________________________________________________ Monitoring Performed By_ /V.iA/f - (V!c Gwz-vfjeS-32EC _
Supervisor
fL-V- <S 5~ (J yA j'2_'2_ \A-_________________________ __
WorkersName(s)______ Lof. \c nw l A,1 rw,\
j--_____
Employee Documentation Yes No Variance
Worker Certificate
zX_____________
Respiratory Protection Yes No Variance
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments__________________
Pressure Differential Bag Type
Vertical Horizontal Comments__________________
Yes No Variance
SWRf/Asbestos 3528 Pressure Differential Bag Quality Assurance Inspection Page 1
Rev & 90 * MAC Ifiyc-jecLs'jyo] mgm\ lorms'ca press difl bap
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes No Variance X
Z______________
x;
x x'
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments
Yes No Variance X ____ _____ X'
Pressure Differential
Bag Application
No Variance
All Seams Sealed
All Holes Sealed
Amended Water Attached Vacuum Attached
X
Encapsulant Attached
Smoke Tested
Comments.
SWRfIAsbestos 3529
Pressure Differential Bag Quality Assurance Inspection - Page 2
Rc*v 6 90 MAC irp'Ojecls'p'O; rngmi fjyms'ca
Oifl nsp
Equipment and Supplies End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments__________________
Yes ,, No Variance
Work Practices . . Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down .Applied Bridging..Encapsulant Applied Tools Removed and Cleaned Pressure Differential Bag Evacuated Bagged Properly Work Area Clean Comments.__________________
Yes ax:
No Variance
ytyfVs
SWRflAsbestos 3530 Pressure Differential Bag Quality Assurance Inspection - Page 3
Rev. 6 SO MAC ir.p'OjeclsVO! mgnt Icymsca p<ess Oifl bag nip
Decontamination Procedures Yes HEPA Vacuum Entire Body Protective Clothing Disposed Properly Baaoed Comments
. No Variance--------
S koi** S'
Inspection Performed By
<2-2M
Date
- ?1
Pressure Differential Bag Oualily Assurance Inspection - Page 4
SWRf/Asbestos 3531
Rev. &90 M-AC I rprojects'O'Oj mgmi fynr.s\ca yen a A bag idsp
Northwest Envirocon, Inc.
16811 El Camino Real, Suite-119 Houston, Texas 77058 (713) 488-8688
Inspector's Checklist
Inspector: \Toe Lo Date:. 2" 2S -
Project:____________________________________________________ ;
Location:
_
Client: Solj -f-Ji uses f-ern fieft'A'.ny__ Co. ^ T,k./---------------------------------
Project Foreman:______________________________________________ ______________
Contractor Name and Address: Gif/y>an Tmv/A-rCo. } JVic.
P.0 Box
Corpus Chr.sl-; } Te/#i___ 775^6?-----------
Phone: 5~/J ~
_________________________
Work Area Observations 1. Work area isolated? 2. All openings to work area sealed? 3. Air movement system sealed off? 4. Negative pressure maintained in work area? 5. Warning signs at all entrances/exits? 6. Number of workers in area: V
Yes No L
Var.
Personal Protective Equipment 7. NIOSH approved respirators? 8. Disposable coveralls? 9. Head covering?
10. Foot/shoe covering? 11. Proper wearing of clothing?
"
Yes No _iZ_
Var.
Change Room
Yes No Var.
12. Hangers for street clothes?
13. Shower available on-site? 14. Containment of contaminated water?
cz --
15. Airlock to shower?
l/
16. Airlock to inside change room? 17. Airlock to work area? 18. Disposal bin for contaminated protective equipment?
i/ _ SWRf/Asbestos 3532 S
Inspector's Checklist, page 2
Work Practices
19. Are wet methods employed?
--
20. EPA recommended wetting agent used?
'
21. Are HEPA filter vacuums used?
22. Stationary items in work area covered and sealed?
23. Are walls and floor covered and sealed?
24. Milage of visqueen used:
< mils
25. Are disposal bags properly labeled?
26. Are workers wearing protective clothing at all
times in work area?
27. Are workers disposing of contaminated clothing?
23. Are respirators worn at all times?
29. Eating, drinking, or smoking in work area?
30. Are workers using the shower?
Yes No Var. ^ -------- ------l/ .. -------- ------_ -------- ------i/ -------- -------
_____ _____ ____
t/ _____ ____
______________ i/ _____ ____ iX . _____ ____ _____ i/ ____ l/ _____ ____
Explain all variances (Var.) in detail in the space below.
m# _7
Explanation - JM
Observations:.
SWRflAsbestos 3533
Northwest Envirocon, Inc.
16811 E! Camino Real, Suite 119*Houston, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client Job Name and#
fern ^/
WoikArea !u/k'
51 1JrrucY^rc
Date c?- Q, 5 -92 Time
Monitorina Performed Bv /V*iA/. --
Lo^.s RoJs/a ue ~2,
Rinervisor
-f r i a*. &u-f / r / & 2_
Workers Name/si
+ D~f c s p , o
Employee Documentation Worker Certificate
Yes
No Variance
Respiratory Protection
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments__________________
Yes No Variance _iZ. ________ /_____
__________ ____________
Pressure Differential Bag Type
Vertical Horizontal Comments________________
Yes No Variance-----_______________
------
'
SWRf/Asbestos 3534
Pressure Differential Bag Quality Assurance Inspection - Page 1
Rev 6- 90 M.AC ir^ojecls'p'Oj mgmt Icxms'ca pew d.tt b-ag /vio
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes j/
No Variance
iZ y_
j/[ </
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments
Yes Nto Variance
i/
jZ _______________
y
_______________ ^
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments.
Yes No Variance y
.
^ _______________
Pressure Differential Bag Quality Assurance Inspection - Page 2
SWRf/Asbestos 3535
Rev. 6 90 MutC irp'oj^cts'O'Oj nvjmi feyms'^a txfesi oK t>a0 *ns?
Equipment and Supplies End Nippers Stitcher Stapler Two Raior Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments__________________
_ _-Yes No Variance ^____________ ^ ^_______________ ^____________
y
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments__________________
No Variance iZ_
SWRf/Asbestos 3536 Pressure Differential Bag Quality Assurance Inspection - Page 3
Rev. 6 90 MAC ir^rojec'-s'p'o-j r%gnj ItyrnsVja pess diff bag r.sp
Decontamination Procedures Yes No Variance
HEPA Vacuum Entire Body
^
S
Protective Clothing Disposed ^ _____ _____ ______________________
Properly Bagged
^ _____ _____
_
Comments___________________________________________________________ _
~xr ---------------- -------------- * Vc. l/ e. 1-- ' "
Inspection Performed By
<2 - 7 J
Date
- 92
Pressure Differential Bag Quality Assurance Inspection - Page 4
SWRflAsbestos 3537
Rev, 6 90 MAC
rrvj'nt tcKT.S'ca
msp
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119 Houston, Texas 77058 (713) 488-8688
Inspector's Checklist
Inspector:
.Date: <3 ~~
~ J2
Project:
55 Ici^V-________________________
Location: c .w\ _________________________________________ ____________
Client: , .S<?u.-fA
te en e.yC/> ,`ny Co. i T*c.-----------------------------------
Project Foreman:.
Contractor Name and Address: GM/nan Taav/a+Jq* Co. } JVic..
_/^J2__B.QJL__ LfO~7(-f Corpus C hs.'sf-i ^ Tefrtl---- 1%H&CL----------
Phone: 5~/J ~ 88*4-
Work Area Observations 1. Work area isolated? 2. All openings to work area sealed? 3. Air movement system sealed off? 4. Negative pressure maintained in work area? 5. Warning signs at all entrances/exits? 6. Number of workers in area: V
Yes No tS.
Var.
iS y
yAi
Personal Protective Equipment 7. NIOSH approved respirators? 8. Disposable coveralls? 9. Head covering?
10. Foot/shoe covering? 11. Proper wearing of clothing?
..... ...
Yes No Var.
y
y y
Chanae Room
Yes
12. Hangers for street clothes?
y
13. Shower available on-site? 14. Containment of contaminated water?
y
15. Airlock to shower?
..... .
jZ_
16. Airlock to inside change room?
17. Airlock to work area?
<y
18. Disposal bin for contaminated protective equipment?
No Var. SWRf/Asbestos 3538
Inspector's Checklist, page 2
Work Practices
---------- ---
19. Are wet methods employed?
20. EPA recommended wetting agent used?
21. Are HEPA filter vacuums used?
22. Stationary items in work area covered and sealed?
23. Are walls and floor covered and sealed?
24. Milage of visqueen used:
< mils
25. Are disposal bags properly labeled?
26. Are workers wearing protective clothing at all
times in work area?
27. Are workers disposing of contaminated clothing?
28. Are respirators worn at all times?
29. Eating, drinking, or smoking in work area?
30. Are workers using the shower?
Yes ' No Var. _______________
.Z!
jZ_______
z:___
jZ_____
z________ _______ *z JZ ____
Explain all variances (Var.) in detail in the space below.
Item #
'T'ujg L.Ot'j
Explanation ot <p I frfy
Observations:
-.specter
07*
"twer'^P*
mnW---->
/
SWRf/Asbestos 3539
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119*Houston, TX 77058*(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client Zoo-/titles Job Name andU(~^i djji-
Work AreaC vh-V Monitoring Performed Bv A/<.iA/. ~
Date
-2-5" - 9
jfLdt'J
_________________*04*/. Time_______________________
Supervisor IZ&Vif^V & ^ p fr<L-z. _________________________________ .
Workers Name(s)_________i M ..FL^-4_______________ q^.ir__ Sinjf&Jz---------
Employee Documentation Worker Certificate
Yes
No Variance
Respiratory Protection
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments_____________________
Pressure Differential Bag Type
Vertical Horizontal Comments__________________
Yes / No Variance
S\NRf I Asbestos 3540 Pressure Differential Bag Quality Assurance Inspection - Page 1
Rev, 6-90 MAC Ifp'ojecis^oj mgmi lex ms'via peu d<ff bag nsg
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes j/
jZ j/; jbZ
No Variance
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments
Yes No Variance t/
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments
.. SWRf/Asbestos 3541
Pressure Differential Bag Quality Assurance Inspection - Page 2
Rev. 6 90 UAC tr^cKKrts^yo, ^*3 mi lorms'^a
o4 baQ unsp
Equipment and Supplies End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments__________________
Yes / No Variance
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments.
No Variance
Pressure Differential Bag Quality Assurance Inspection Page 3
SWRf/Asbestos 3542
Rt-v. 6 SO MAC Ifprojec'.s'.p'Oj "19m lorms'ca p-e&s did baj hsp
Decontamination Procedures Yes No Variance ...........................--
HEPA Vacuum Entire Body
tS _____ _____
Sy
Protective Clothing Disposed ^ _____ _____
______________
Properly Bagged
^ _____ _____
___ __________
Comments_____________________________________________________________ __
- `TAnaInspection Performed By
^-3 ~ 92. Date
Pressure Ditferential Bag Qualily Assurance Inspection - Page 4
SWRf/Asbestos 3543
Rev. 6- 90 MAC
rngm hy'r.s'^a P'eis <3.ft bag
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119 Houston, Texas 77058 (713) 488-8688
Inspector's Checklist
Inspector: 3~c?e LoiP.Js.'c. uni. Date: <2 " ^ b
Project:__ CsuJ*. )
Location: T/oW
___________________________________________
Client:_^pi/
f/i
bscj c
^e.r/?__
Re/LAjl
<Cc>. j Tf
Project Foreman: iz-fru:*
Yi rr-c t_
Contractor Name and Address: Giisn#/iT* <vfA-rJc> Co, jJVic.
_ -P__& ox.___Hom Corpus Chris-t't ; Te/m___ y%
_
Phone: S~/J - 88Wt?C
Work Area Observations 1. Work area isolated? 2. All openings to work area sealed? 3. Air movement system sealed off? 4. Negative pressure maintained in work area? 5. Warning signs at all entrances/exits? 6. Number of workers in area: V +* (..
Yes No Var.
Personal Protective Equipment 7. NIOSH approved respirators? 8. Disposable coveralls? 9. Head covering?
10. Foot/shoe covering? 11. Proper wearing of clothing?
Yes No Var.
i/ y y
Change Room 12. Hangers for street clothes? 13. Shower available on-site? 14. Containment of contaminated water? 15. Airlock to shower? 16. Airlock to inside change room? 17. Airlock to work area? 18. Disposal bin for contaminated protective equipment?
Yes
y y
y y
(/
y
No Var. - SWRf/Asbestos
Inspector's Checklist, page 2
Week Practices
19. Are wet methods employed?
--
20. EPA recommended wetting agent used?
'
21. Are HEPA filter vacuums used?
22. Stationary items in work area covered and sealed?
23. Are walls and floor covered and sealed?
24. Milage of visqueen used:
< mils
25. Are disposal bags properly labeled?
25. Are workers wearing protective clothing at all
times in work area?
27. Are workers disposing of contaminated clothing?
28. Are respirators worn at all times?
29. Eating, drinking, or smoking in work area?
30. Are workers using the shower?
Yes No Var. t/ - _____ ____
_____ _ ____ </ _ _____ ____ t/ _ _____ ____ _____ _____ ____
t/ _____ ____
_______________ i/ _____ ____ i/ _____ ____ _____ </- ____ i/ ______ ____
Explain all variances (Var.) in detail in the space below.
Item # 11
P. Pi. P. R 1 L& V r s-
Explanation
, / Pp / LS s /
Observations:
*C\cr: r:r;:Cr **vrCTr
<s(Z L.
SWRf/Asbestos 3545
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119*Houston, TX 77058*(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Cltent S'aut, .ic.
Dale 3 ~ 6 -92_______
Job Name and# C/ij# ('__________________________________________________________
Vtotk Area
f
P, a ci Time /V l 2 &
Monitoring Performed Bv A/.W.t ~ Joe Lois.s R oJs,'a ue ~i,
Supervisor
f a- ;
_________________________ :
Workers Namefst
J ~f o f.c.<g.~___ J -___{
.jAeeJ.'
Employee Documentation Yes _ _ No,. Variance
Worker Certificate
*/_
Respiratory Protection Yes No Variance
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments__________________
Pressure Differential Bag Type
Vertical Horizontal Comments__________________
Yes No Variance......
Pressure Differential Bag Quality Assurance Inspection - Page 1
SWRflAsbestos 3546
Rev, 6- 90 * M.AC If'^yojfcCls'fyO} mgmt Icyms'oa fffcbs ditl bag r\sp
Protective Clothing Disposable Coverall Hood Booties Gloves Wrisis Taped Comments____________
Yes j/
No Variance
Z uZ
t/_ /
Pre-Application Work Area Regulated Signs Posted Maierial Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reintorced Comments______________
Yes No Variance </
i/
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments_______________
Yes No Variance
_uZ_ z; u/______________ Z cX___________
z
-- Pressure Differential Bag Quality Assurance Inspection - Page 2
SWRf/Asbestos 3547
Rev 6 &0 MAC ir^cAli,P'0; rr^mi tc^ms'ca (vtsi bag ins?
Equipment and Supplies End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments
Yes
jA.
No Variance
-Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments__________________
Yes c/ j^L
No Variance
S\NFtf I Asbestos 3548
Pressure Differential Bag Duality Assurance Inspection Page 3
Rev 6-90 MAC ir.proifrC'.V.p'oj
toms'ca pew did bag rup
Decontamination Procedures Yes
HEPA Vacuum Entire Body
^
No Variance
Shot** e-
Protective Clothing Disposed
_____ _____
Properly Bagged
^ _____ _____
_______ _ _
Comments_________________________ ;____________________________ __________
IX
Inspection Performed By
1X
- 92
Dale
SWRf(Asbestos 3549 Pressure Difterenlial Bag Quality Assurance Inspection - Page 4
Rev. 6-90 MAC irp'ojec'J'O'oj rrvjrrn formica yew d*M bag ir-sp
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119 Houston, Texas 77058 (713) 488-8688.
Inspector's Checklist
Inspector:, FllU/EGyyrziaJff^^-
D ate: <2
5^
P roject:______ lit A V-__________________________
Location
c^i4-
Client:. _<2u.fh CureJ Ce.cn &!-a Co. , JlVjc,
Contractor Name and Address: G H/nan T^als/ai-Jo*!__ Co. > Srsc..
P.0 Box Corpus*----------------------------------------------------------------------------------------- ---C----h---r-r--i---t----j--- JT---7--~--g--/-n---s-------7---^---V-- 69
Phone: S/0 - <?$</- V9oL
Work Area Observations 1. Work area isolated? 2. All openings to work area sealed? 3. Air movement system sealed off? 4. Negative pressure maintained in work area? 5. Warning signs at all entrances/exits? 6. Number of workers in area: ^
Yes No _jzL
Var.
SC/h
Personal Protective Equipment 7. NIOSH approved respirators? 8. Disposable coveralls? 9. Head covering?
10. Foot/shoe covering? 11. Proper wearing of clothing?
"
Yes No Var.
Chanae Room 12. Hangers for street clothes? 13. Shower available on-site? 14. Containment of contaminated water? 15. Airlock to shower? 16. Airlock to inside change room? 17. Airlock to work area? 18. Disposal bin for contaminated protective equipment?
Yes No Var.
c/
--
jZL
L/ i/ _ SWRf/Asbestos
Inspector's Checklist, page 2
Work Practices
--
19. Are wet methods employed?
20. EPA recommended wetting agent used?
21. Are HEPA filter vacuums used?
22. Stationary items in work area covered and sealed?
23. Are walls and floor covered and sealed?
24. Milage of visqueen used:
& mils
25. Are disposal bags properly labeled?
26. Are workers wearing protective clothing at all
times in work area?
27. Are workers disposing of contaminated clothing?
28. Are respirators worn at all times?
29. Eating, drinking, or smoking in work area?
30. Are workers using the shower?
Yes No _______ ____
Var.
JZ._______
________ i/_______ ^________ _______ i/ J/L ____
Explain all variances (Var.) in detail in the space below.
Item
lA.
l
Explanation of paly
Observations:
E(lNl Gcy\
SWRf/Asbestos 355 j
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119*Houslon, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client
use stem <6?/V/t, Vrc
.hhMame anrl#
C Vir\ /t_
.
Work Area_ ^vy-V 1.Time
Monitoring Performed Bv AC W. /: ~ Supervisor iloWfl'V
Workers Name(s)_
Q.fJ V...
Date
~ ^ 6?____ ""JtiL
*/
i------------
Employee Documentation Worker Certificate
Yes
No Variance
Respiratory Protection
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments
Pressure Differential Bag Type
Vertical Horizontal Comments__________________
Pressure Differential Bag Quality Assurance Inspection - Page 1
SWRflAsbestos 3552
R&v 6-90 MAC M^O'&cis'P'O; mgmi fexms'ca pes* d.fl bag
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes No Variance t/
iZ jX (/_
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments_______________
Yes No Variance
z
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments.
Pressure Differential Bag Quality Assurance Inspection - Page 2
SWRflftsbestos 3553
Rev. 6 90 MAC ir*y cnecis'^yoj mgmt lo'ms'ca ptrSA ditf bag msp
Equipment and Supplies End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments__________________
Yes ^ No Variance 2
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments._________________
..........
.
SWRf/Asbestos 3554
Pressure Differential Bag Quality Assurance Inspection - Page 3
Rev. 6 SO MAC If.p'Ojec'.s'p'o; nj'-ti Icyrr-sca p'ess fl'tl baj r.s,p
Decontamination Procedures Yes-- No Variance
HEPA Vacuum Entire Body
iX _____ _____ __
J*koi~ e
Protective Clothing Disposed Properly Bagged
_____ _____ ^ _____ _____
________ _____ _
Comments__________________________________________________________
Inspection Performed By
Date
SWRf/Asbestos 3555
Pressure Differential Bag Quality Assurance Inspection Page 4
Rev. 6-90 * MAC IT^yoj^c'J'O'Oj
to^r.s'ca yew o-H bag ir.sp
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119`-Houston, Texas 77058 (713) 488-8688
Inspector's Checklist
Inspector: 3~oe Lo^;t R+JsSave.2,
______ Date: <3 2 7
5A
Project: <^4/^_________________________________________
Location: S/r/.-f
____________ __
Client: .5c?i/ -fh UseS /-& rn__ /fg/Vri
j JTi.gg-------------------------------
Project Foreman: V/vi/,t
i s s e ~t~
Contractor Name and Address: Gtf/y>*s\
of\ 0. j -TV) c. .
V^7V Corpus Chr-jJ-i j T&Xjsa--7 7$ V.2--------- :
Phone: 5~/J -
______________________________________ _
Work Area Observations 1. Work area isolated? 2. All openings to work area sealed? 3. Air movement system sealed off? 4. Negative pressure maintained in work area? 5. Warning signs at all entrances/exits? 6. Number of workers in area: 7
Yes No ..(S.
Var.
Personal Protective Equipment 7. NIOSH approved respirators? 8. Disposable coveralls? 9. Head covering?
10. Foot/shoe covering? 11. Proper wearing o'f clothing?
... .
Yes No Var.
Z S
Chanae Room
Yes
12. Hangers for street clothes?
lS
13. Shower available on-site? 14. Containment of contaminated water?
z
15. Airlock to shower?
jZL
16. Airlock to inside change room?
17. Airlock to work area?
(/
18. Disposal bin for contaminated protective equipment? y
No Var. SWRf/Asbestos
Inspector's Checklist, page 2
Work Practices
19. Are wet methods employed?
--
20. EPA recommended wetting agent used?
'
21. Are HEPA filter vacuums used?
22. Stationary items in work area covered and sealed?
23. Are walls and floor covered and sealed?
24. Milage of visqueen used:
& mils
25. Are disposal bags properly labeled?
26. Are workers wearing protective clothing at all times in work area?
27. Are workers disposing of contaminated clothing?
28. Are respirators worn at all times? -
29. Eating, drinking, or smoking in work area?
30. Are workers using the shower?
Yes No Var. t/- _____ ____ tX _ _____ ____
_____ ____ i/ _ _____ ____ _____ _____ ____
l/ _____ ___ l
l/ _____ ____
\S _____ ____
tX _____ ____
_____
____
l/ _____ ____
Explain all variances (Var.) in detail in the space below.
Item#
~7~
P ft.
Explanation
- ?M
1 L(
7 y f '* f ^
C /h.; / /%/ >
Observations:
4 i- o -
c c P / r-
SWRf/Asbestos 3557
Northwest Envirocon, Inc.
16811 El Camino Real. Suite 119*Houston, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client
Date ^7 -9=1------------
Job Name and# ^ m f**/____________ ______________________________/?Q _________
Woik Area 7 < 3 Pi P<' P r s Time /A ! O a
Monitoring Performed By Supervisor__ V/"4-
< c- fV-'
RqJp<:$..*.3,---------------_______________________________________
Workers Namefsl
J Y o c .r ^
o -A- ^ O -A J>A(, G
Employee Documentation _ Yes. . No Variance. Worker Certificate
Respiratory Protection Yes No Variance
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments
Pressure Differential Bag Type
Vertical Horizontal Comments________________
Yes No Variance------
Pressure Differential Bag Quality Assurance Inspection - Page 1
SWRf/Asbestos 3558
Rev. 6- 50 MAC ir^xoj&cts'O'Oj mgmi fcymsVia press dift bag rvsp
Protective ClothingDisposable Coverall Hood Booties Gloves Wrists Taped Comments______________
Yes
J/ jX
No Variance jX
jX
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work.Area Bottom Seam Reinforced Comments
Yes No Variance ________________
i/
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments_______________
Yes
No Variance
Pressure Differential Bag Quality Assurance Inspection - Page 2
SWRflAsbestos 3559
Rt*v. 6 90 * M.AC ir^yc^Cli'^YOj rr^ml IcKms'^a p/feiS 0`H bag *n$p
Equipment and Supplies End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments
Yes
X
X
No Variance
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments__________________
Yes No Variance
X X
X
.x:
X X X
" -- Pressure Differential Bag Quality Assurance Inspection - Page 3
Rev 6 90 * MAC ir^yojecis'^yoj mgnt
SWRf,IAsbestos 3560
p'eu ditl bag rtsp
Decontamination Procedures Yes No Variance - --....
HEPA Vacuum Entire Body
1/ _____ _____
J e-
Protective Clothing Disposed
_____ _____ ______________________
Properly Bagged
_____ _____
_
Comments_________________________________________________________
.
Inspection Performed By
w t-_______________ cZ- - ^ ^ Dale
~ 92
.......... Pressure Differential Bag Quality Assurance Inspection - Page 4
SWRfJAsbestos 3561
Rev. 6 90 KKAC lf.p<ojec'J'p'Oj rvg-Ti! tcvr.s'ca yen fl.H hag irsp
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119*Houston, TX 77058-(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client
<6?///-.'/re. Co; i^c
Date <? - 2-7
- 92
Job Name and#_________________________________
_________________ S?Q6</
Work Area. C-Arl
Time.
Monitoring Performed By_ A/.w.f - (lNl_&i<svrz.d&5
Supervisor
GrtpAfiZ-uO-
Workers Name(s)____
..Ou..L S
Employee Documentation Worker Certificate
Yes
No Variance
Respiratory Protection
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments_____________________
Variance
Pressure Differential Bag Type
Vertical Horizontal Comments__________________
Yes No Variance
Pressure Differential Bag Quality Assurance Inspection Page 1
SWRflAsbestos
Rev, 6- 90 M.AC If^'Ojecis'ivo, mQmi fctfms'oa (xess d<t1 bQ miD
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments____________
Yes No Variance t/
________________ j/ j/
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments_______________
Yes No Variance X j/
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments.
Yes
No Variance
Pressure Differential Bag Quality Assurance Inspection - Page 2
Rev 6 90 MAC If^ojects-cvcH mgmt
SWRf/Asbestos 3563
ptss d'K bag n$p
Equipment and Supplies End Nippers Stilcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments__________________
Yes No Variance /____________
Hi______
/
~V
1
Work Practices Adequale Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments____________
Yes , No Variance
/
Pressure Differential Bag Quality Assurance Inspection - Page 3
SWRflAsbestos 3564
Pev. 6 90 MAC irprojecis'pfoj
toms'ca pew dirt bag rvip
Decontamination-Procedures Yes No Variance
HEPA Vacuum Entire Body
iX _____ _____
Shoi~- e-
Protective Clothing Disposed Properly Bagged
iS* _____ _____ ______________________
^ _____ _____
_
Comments
_________________________________________________ ___________
Inspection Performed By
<2 - 27 Date
-92
Pressure Differential Bag Quality Assurance Inspection - Page 4
Rev. 6 90 * UAC Ifp'ofecia'^oj rr^mi
SWRf/Asbestos 3565
d;ft i^sp
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client SoLrJAuses
Date 3. ~ ^ $ ~ ________
Job Name and#
^ <XOA1/
Work Area J f s * c
^ P. p ^ s* e. A y Time rf* O & -
Monitoring Pertormed Bv ASj/1/./r ~ 3~oa Lex^.s R oJs/a ve i.
Supervisor______
^ <^Tc- r* rQ
e. ?_________________________________
Workers Namefs)
<: -r
o '- 4 j
.
Employee Documentation Yes _ No ...Variance Worker Certificate
Respiratory Protection Yes No Variance
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments
Pressure Differential Bag Type
Vertical Horizontal Comments________________
Yes No Variance
Pressure Differential Bag Quality Assurance Inspection - Page 1
SWRf/Asbestos 3566
Rev. & 90 MAC if.fyojects'^'Oj mgmi forms Via p^esi diff bag *">4p
r^
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped
-
~-Yes-- No Variance
1/ ^ if ^
Comments____________________________
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments______________
Yes No Variance tX
_______________
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments__________________
Yes
No Variance
Pressure Differential Bag Quality Assurance Inspection - Page 2
Rev 6 90 MAC
mgmt
SWRf/Asbestos 3567
fve-ss d'W bap ,n$?
Equipment and Supplies Yes No Variance End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments
Work Practices Adequate Wetting " Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments__________________
Yes ,, No Variance
--- --
" -
(-S'
lS1
SWRf/Asbestos 3568 Pressure Differential Bag Quality Assurance Inspection - Page 3 '
Rev. 6 SO MAC If.piCHec'.s'P'Oj mg-il fO'msVja p>e ditt bafl r.sp
Decontamination Procedures Yes No Variance
HEPA Vacuum Entire Body
^ _____ _____ _
Ss'
Protective Clothing Disposed ^ _____ _____
__________
Properly Bagged
^ _____ _____
_____ __________
Comments___________________________________________________________
s^'VCD
J
1J
L
Inspection Performed By
23 -92 Date
Pressure Differential Bag Quality Assurance Inspection - Page 4
SWRf/Asbestos 3569
Rev. &90 WAC ir^KO^CJ'^yoi mg-ru twrr.sVja p-eas o f) bag r.sp
Northwest Envirocon, Inc.
16811 El Camino Real, Suile 119Houston, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client
sfes/i
Date_
7 o -yj
Job Name and#_____________________________________________________________ O&V
Work Area_
3- Time
Monitoring Performed Bv A/^W.t ~ .N[ GnoW2.w-\ 65T^_
Supervisor t2.o
.4- * <yQ lArILI. A-
...
v
WorkersName{s)__________ /-aw \ j InoV t-vs-V______________________
..
Employee Documentation Worker Certificate
Yes
No Variance
Respiratory Protection
1/2 Mask Pressure Differential PAPR Properly Donned Fit Tested Comments____________________
Yes No Variance
fist# \s /
Pressure Differential Bag Type
Vertical Horizontal Comments__________________
Yes No Variance
Pressure Differential Bag Quality Assurance Inspection - Page 1
SWRf/Asbestos 3570
Rev 6 SO MAC ITp'ojects'fKo; rrwgmt fcwms\ca pesa dirt bag msp
Protective Clothing Disposable Coverall Hood Booties Gloves Wrists Taped Comments_____________
Yes _t/
jX j/ X
Nto Variance
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments________________
Yes No Variance tX
Pressure Differential Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments____________________
X...
SWRf/Asbestos 3571
Pressure Differential Bag OuaMy Assurance Inspection - Page 2
Rev 6 90 MAC irp'ojecis'o'Oj
fcKms ^a fyess ditf bag msp
Equipment and Supplies End Nippers Stitcher Slapler Two Raior Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments
--- -
................. SWRf/Asbestos 3572
Pressure Differential Bag Quality Assurance Inspection - Page 3
Rev. 6-50 * MAC ir^Djecii'^o; mgnt
p^ess dirt bag nip
Decontamination Procedures Yes .... No-Variance.
HEPA Vacuum Entire Body
iX _____ ______
Ss*
Protective Clothing Disposed Properly Bagged
^ _____ ______ ^ _____ ______
_ ___ ___________
Comments___________________________________________________________________
s. > GbOW^) Inspection Performed By
-91
Date
SWRflAsbestos 3573
Pressure Differential Bag Quality Assurance Inspection - Page 4
Rev. 6 90 MAC tf-^ojecis'rfyoj rr^^\ ftyrns'ca p'ew o;rt bag iQsp
-_Northwest Envirocon, Inc. .. 7_
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
Client
/e^/i
Co. . "7Date ,2
^ 2.--~ -------------
Job Name and #_ C+*
Work Area
& t/? J j /us J>' *- s-Time
MonitoringPerformed By /V*W. ~
S.'OQ
Lots.s
Supervisor Workers Namefst
i 7-
r*s' f ss-g X <r s e-o ,,
_________ ___________________________
RoJL>e~t.-------------
Z2-r ^ c> r S6 e'er ^
Employee Documentation Worker Certificate
Yes
No Variance
Respiratory Protection __ Yes____No--Variance
1/2 Mask Pressure Differential PAPR Properly Donned------Fit Tested Comments___________________
Pressure-DI f f ereml at-- Bag Type
Vertical Horizontal Comments_________________
Yes No Variance-
SWRflAsbestos 3574
Pressure Differential Bag Quality Assurance Inspection - Page 1
Rev. $-90 MAC lf\projecis\fKOj mgmt fcxms'ca p^esi dff bag irisp
V Protective Clothing
Yes No Variance:
Disposable Coverall
tX ___ -
Hood Booties Gloves
________ j/
____________
Wrists Taped
Comments_____________
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments________________
Yes No Variance
_*/ _i/
___ _ _____
-UL_ ______
___________ ____
V
Pressure- Differential---- Bag Application
All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments.
Yes No ^1:
Variance
Pressure Differential Bag Quality Assurance Inspection - Page 2
.......................... .. _ Rev. 6 90 MAC ir^yojecis'proj mgmt
SWRflAsbestos 3575
t>ag *nsp
Equipment and Supplies End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments___________________
Yes----- No--Variance
JZ--
jZ--
iZ-
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments----------------------------
JZiZL
No Variance.,
SWRf/Asbestos 3576
Pressure Differential Bag Quality Assurance Inspection - Page 3
Rev. 6- 90 MAC irprojecis'fKOj rr>Qmi form$\ca pKss otfl tag nsp
t-------------- Decontamination-Procedures--^es-------No--Variance-----------------------------------
----- HEPA Vacuum Entire Body
^ _____- ----------- Se
Protective Clothing Disposed
_____ _____
_______ _
Properly Bagged
_____ ______
_
Comments_____________________________________________________ _____________
'l/* ------------------ ---------=---- ---------------------------Inspection Performed By
2- ?9. Dale
Pressure Differential Bag Quality Assurance Inspection - Page 4
SWRflAsbestos 35//
Rev. 6-90 MAC ir^xo^ecuVyoi mgmi tormina l>u bag 'r-sp
Northwest Envirocon, Inc.
16811 El Camino Real, Suite 119Houston, TX 77058(713) 488-8688
Asbestos Program Assessment Quality Assurance Inspection Pressure Differential Bag
2- 4^
Client Sou-/A usestem
Job Name and #_ Work Area /9-/-Z y
Monitoring Performed By /K IA/. --
Supervisor_______ ^obr^/-
,,
Date.
-92
Workers Name(s)_
Employee Documentation Yes No Variance"
Worker Certificate
____________
Respiratory Protection
Yes No__ Variance.
1/2 Mask Pressure Differential
PAPR
Properly Donned
-
Fit Tested
Comments___________________
"PreTSirre Dl ffereTitlal-- Bag Type
Vertical Horizontal Comments_________________
Yes y No Variance
SWRf/Asbestos 3578
Pressure Differential Bag Quality Assurance Inspection - Page 1
_______
______ _________________ . _ Rev. 6-90-.MAC ir^xojercls'p'o; mgmi (wmtV33 (xess
bag injp
Protective Clothing-----Disposable Coverall Hood Booties Gloves Wrists Taped Comments_________________
--Yes------ No--Variance tX ______ __
_iZ. _j/ _j/_
Pre-Application Work Area Regulated Signs Posted Material Wetted Tools Placed in Glove Bag Plastic Under Work Area Bottom Seam Reinforced Comments_______________
No Variance
Bag Application All Seams Sealed All Holes Sealed Amended Water Attached Vacuum Attached Encapsulant Attached Smoke Tested Comments
Yes^/^ No
/C / tS
Variance
--
SWRflAsbestos 3579
Pressure Differential Bag Quality Assurance Inspection - Page 2
.Rev. 6-SO MAC ir^ojects'^oj mgmt fc^ms'ca p^esi bag msp
Equipment and Supplies End Nippers Stitcher Stapler Two Razor Knives Re-wettable Cloth Duct Tape Nylon Brush Wet/Dry HEPA Vacuum Scotch Pad Plastic Baggies Barrier Tape (Asbestos) Comments___________________
Yes, No -Variance
T
~r
t/ (
T
Work Practices Adequate Wetting Proper Handling Folding Sharp Ends In Surface Adequately Cleaned Lock Down Applied Bridging Encapsulant Applied Tools Removed and Cleaned Pressure Differential
Bag Evacuated Bagged Properly Work Area Clean Comments - ----------- ...
Yes,/: No Variance
V.
2
T
Pressure Differential Bag Quality Assurance Inspection - Page 3
SWRf/Asbestos 3580
Rev. &90 MAC ir.piojecls'p'oj mgrit |(ymsV;a p'esl diH bag nip
Decontamination Procedures--Yes------No--Variance------------------------------------
HEPA Vacuum Entire Body
^ _____ _____ ..
Ss*
Protective Clothing Disposed ^
__
Properly Bagged
^ _____ _____
_______________
Comments___________________________________________________________________
~tr~ - ----- ---- Inspection Performed By
Z- Z.S -
^--=---------- Dale
- 92
Pressure Differential Bag Quality Assurance Inspection - Page 4
SWRf/Asbestos 3581
Rev. 6-90 * MAC If'proyecis'CKOj rrgmt hxrr.s'ca fxesi o<tf bag msp
SWRf/Asbestos 3582
1
(
\i c
-Cs
Cost Distribution by Branch or Project & Function
^-
Branch or Functional
Project No.
Code
#061.... SO &F
<?/''' -`<S IS * 2, ... ........^-----
Sun.
Mon.
Tues.
H
hr^
Wed.
n
Triur.
ns
Fri.
a
Sat.
ns
Total 4y
<. S,,
Totals j
Project No.
Date
6*06 V ~?-/8 -n
- tc i<
h
u
5^30 - U
-n b- ,?T . 7J
I 1
l 1l
i
ii
| | /(-/ U 1 /J.s JiA___ /Is \ 6
Client Name
1/ (i 1/
Description of Services /ftt*7P ffl&A ~ ^ c 4j sw/) j*j> ca <* /l.S
!, (1 [i
C*%
Zjtqkt* fcpnrtr*
?
C*r
SWRf/Asbestos 3583
Cost Distribution by Branch or Project & Function
Sdto\
,?- -2l
Branch or Project No.
RM
Functional Cods
S'o'l.l
Sun.
Mon.
n
Tues.
)l
Wed. ZJ"
Thur. /Z-.5"
Fri.
Sat. Total
/2-^. 7S
.
___________ !___________ 1 I !
1 Teals
1/7 1 //
1
/2->" 1 y2--T
11 1!
/?>" I /^r 1 7>s
Project No. Aw
ti
fI
l
Dale Z-Z-^Z Z-Z7 -9)
'' -------
' 2.-.2S-9ZlaaS-9*2. 1 1 1
1 1
Client Name
^HvWe.4- (2&V 1
Cl
* V S
>V
L
Description cf Services
t ( -
1f
>i 11 /1
amXiQdAJxfAaiISC-
I
by
SWRf/Asbestos 3584
Cost Distribution by Branch or Project & Function
A, A... ,
P-j 9-92
Branch or FunctionaJ
Project No.
Code
Rr>W STOPS'
Sun. ------
Mon.
ns
Tues. //
Wed.
tv
Thur.
Fri.
ns
Sat.
rs
Total
-
Totals
l !
1
-- nr 1 n
/Y
1 |1
|
/ 1 1 /.If /J l it
Project No.
YcAA Yo C 7 <??> ri w
Dste
1- -91 11 Z>.
n
Client Name /~i,,... ; mY- ^ /
Description of Services
9. r YP. r_ 6^ ^ /?
Wf bf
Cmm
jV-f^ Crw
SWRf/Asbestos 3585
Northwest Envirocon, Inc.
Cost Distribution by Branch or Project & Function
Supplementary Expense Reimbursement Data Sheet
|
Expense Reimbursement'
. f*<r /-/r
Branch or Project No.
806W
Functional Code
Comment
fy-/-O--
Pdf'
1
, X7
Amount $ ol S^ &o
go t? <-Y
/c<t
^,7fX /JO___ ______ n.?o l?9S-d
La j t Us fr f'Cf f'l r C 'M fTi, fcA <',
SnL V #0 4 V
/JT- <
* |
tr* x <25?<s>
** Xo.oe
VJ . * _ /53- **
ami
1 ' Receipts required for motels, authorized entertainment, gas or repairs to company owned vehicles, and
miscellaneous expenses; no receipts required (or standard per diem reimbursements.
SWRf/Asbestos 3586
SWRf/Asbestos 3587
Northwest Envirocon Inc.
r" \
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
_________________ Air Sample, Analysis Report__________
Client: southwestern REFINING COMPANY. INC. Attention: BARBARA POPE Contractor: GILMAN INSULATION CO., INC.
Project: cat # l STAIRWAY COLUMN
NWE Job Number: 8064 Report Date: 2-15-92
Report Number: l Page: 1 of: 2
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
BLK-1 02159iBLK1 BLANK N/A
Work Being Performed (respirator, if applicable)
N/A
Sampls Deposition: Your samples will be returned In 30 days Hwe do not racaive a signed latter authorizing disposal.
BLK-2 0215&2BLK2 BLANK N/A
N/A
AP-3 02i5a2AP3 Back ground gkuuND fluuk NORTHSIDE OF STAIRWAY PRep-work
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaoe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaoe Blank Fibers/Fields Fibers/Sauare mm Coefficient of Variation Fibers/cc 8 HR TWA
2-15-92 JOE RODRIGUEZ 0 0:00 0:00 0
o. oo 0.00 o.oo 0
2-15-92
0.00785 1/100 1/100
0.00 0. 00 0 0
2-15-92
JOE RODRIGUEZ 0 0:00 0:00 0
tom o. oo tom 0.00 Iran 0.00
10
2-15-92
0.00785 1/100 1/100
0.00 0.00
0 0
2-15-92 JOE KUUKIGUEZ PER-A 10:20 lS:20 200
tom 3-00 tom B-0B tom d-0a
1 924
2-15-92
0.00735 11/100 1/1UO '
12. /3 1 . b4
0.009 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom torn tom
|
Comments:
Analyzed by: J E Typist's Initials:
! GUEZ
SWRf/Asbestos 3588 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO., INC. Attention: BARBARA POPE Contractor: GILMAN INSULATION CO.. INC.
Project: CAT # 1 STAIRWAY COLUMN
NWE Job Number: 8064 Report Date: 2-15-92
Report Number: 1 Page: 2 of: 2
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sa:noie OtsDOSrtion.; Your samples w.l' bs relumed in 30 da/E if we Co no: recer/9 a signed letter authoring disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
Work Being Performed (respirator, if applicable)
AP-4 021592AP4 BACK GROUND 2ND. FLOOR SOUTHS IDE OF STAIRWAY PREP-WORK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaqe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-15-92 JOE RODRIGUEZ PER-C 10:20 15:20 300 3.08 3.08 3.08 924 2-15-92 0.00785 11.5/100
1/100 13.37 1.63 0.009
0
1pm tom 1pm tom 1pm _______________________ toni
11
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room,
STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
I
Comments:
Analyzed by: u R ^ F i g u E z. Typist's Initials: J'-R<
SWRf/Asbestos 3589 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
V
__________ Air Sample Analysis Report__________
Ciient: SOUTHWESTERN REFINING CO. .INC. Attention: BARBARA pope
Contractor: G[LMAN INSULATION CO.. INC. Project: CAT # 1 STAIRWAY COLUMN ENCLOSURE
NWE Job Number: Report Date:
Report Number: Page:
8064 2-18-92 2
1 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Tvoe of Sample Location of Sample
E -1 021892B1 BLANK N/A
Sample Disposition: Your samples will be returned In 30 days ilwe do not receive a signed letter authorizing disposal.
E-2 021892B2 BLANK 'N/A
AD-3 021892AD3 AREA OUTSIDE ENCLOSURE EXIT GROUND FLOOR
Work Being Performed
N/A
N/A
PREP-WORK
(respirator, if applicable)
Date Sampled
9-1R-O9
2-18-92
2-18-92
Sampled Bv Pump No. Time Started
JOE RODRIGUEZ O O *00
JOE RODRIGUEZ 0 0:00
JOE RODRIGUEZ PER-B 9:00
Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaqe Flow Rate Volume
n; on o' n.on a.no o.oo o
0:00
0 bra o. oo bra o.oo bm o.oo
1o
12:30 210
bm 3.08 bm 3.08 bm 3.08
1 646.8
Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
'-18-92 0.00788
2/100 1.5/100 0.00 0.00 0 0
2-18-92 0.00785
1/100 1.5/100 0.00 0.00 0 0
2-18-92 0.00785 14/100
1.5/100 15.92 1.60 0.015 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
bm bm bm
1
May Represent Exposure to:
Comments:
Analyzed by: rtODGtR Fay Typist's Initials: J.R.
SWRf/Asbestos 3590
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO., INC. Attention: BARBARA POPE Contractor: GILMAN INSULATION CO. . INC.
Project: CAT # 1 STAIRWAY COLUMN ENCLOSURE
NWE Job Number: 8064 Report Date: 2-18-92
Report Number: 2 Page: 3 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samplas w;n be relumed In 30 days if we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
STE-7 021892STE7 SHORT TERM EXP0SUE JESUS MATA 460-43-0216
AD-8 021892AD8 AREA OUTSIDE ENCLOSURE EXIT GROUND FLOOR
NAE-9 ~021By2NAEy
Exhaust OUTSIDE neg. AIR EXHAUST tt
5
Work Being Performed
GROSS REMOVAL
GROSS REMOVAL
GKUSb KEMUVAL
(respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Average Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
P.A.P. R 2-18-92 JOE RODRIGUEZ PER-D 17:30 18:00 30 2.41 2.41 2.41 72.3 2-18-92 0.00785
8/100 1.5/100 8.28 0.00 <0.044 0.035
2-18-92 JOE RODRIGUEZ PER-1033 14:30 19:50 320 Idiu 3.08 1pm 3.08 tom 3.08 1 965.6 2-19-92 0.00785
11/100 1.5/1O0 12. 10 0.00 <0.O05 0
2-18-92 JOE K U 0 R1G U E 4 ""PER-1041 14:30 --iS:50
ipm
ipm
tom 1 985.b
tom tom
|
..2-19-92
0.00785
4/100
1.S/100
"3.15-----------------------------------
0. OU
--5CU7TRJI
u
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: RE"A' Typist's Initials: J. R.
SWRf/Asbestos 3591 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO., INC. Attention: BARBARA POPE Contractor: GILMAN INSULATION CO., INC.
Project: CAT # 1 STAIRWAY COLUMN ENCLOSURE
NWE Job Number: Report Date:
Report Number: Page:
8064 2-18-92 2
4 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned in 30 days Ifwe do not receive a signed tetter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
AD-10 021892AD10 AREA OUTSIDE OF ENCLOSURE EXIT
P-11 021892P11 PERSONAL JESUS MATA 460-43-0216
Work Being Performed
2ND. FLOOR GROSS REMOVAL
GROSS REMOVAL
(respirator, if applicable)
P.A.P.R
Date Sampled
2-18-92
Sampled By
JOE RODRIGUEZ
Pump No.
PER-1035
Time Started
14:30
Time Ended
19:50
Total Minutes Sampled
I 320
Flow Rate Start
3.08
Flow Rate End
3.08
Averaae Flow Rate
3.08
Volume
985.6
Date Analyzed
2-19-92
Graticule Field Area
0.00785
Total Fibers/Fields
13/100
Averaqe Blank Fibers/Fields
1.5/100
Fibers/Sauare mm
14.65
Coefficient of Variation
0.00
Fibers/cc
0.009
8 HR TWA
0
2-18-92 JOE RODRIGUEZ PER-A 18:00
19:50 110 km 2 01 km 2.01 km 2.01 1 221.1 2-19-92 0.00785
38/100 1.5/100 46.49 0.00 6.081 0.03b
km km
km l
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
km km km
1
May Represent Exposure to:
Comments:
Analyzed by: frODGER fay Typist's Initials: J 'n:-
SWRf/Asbestos 3593 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
Client: SOUTHWESTERN REFINING CO.. INC.
NWE Job Number: 8064
Attention: Barbara pope
Report Date: 2-19-92
Contractor: G[lman INSULATION CO., INC.
Report Number: 3
Project: CAT # ! STAIRWAY COLUMN ENCLOSURE & GL0VEBAG
Pa9e: 1 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples willba relumed In 30 days if we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Tvoe of Sample Location of Sample
_JLJ______________________ 021992B3_________________
BLANK___________________ N/A
B-2 021992B2 BLANK N/A
P-3 021992P3 PERSONAL ERASMO MARTINEZ 455-25-8425
Work Being Performed
N/A
N/A
WIPE DOWN
(respirator, if applicable)
HALF MASK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start
9-19-92__________________
TOE RODRIGUEZ__________
_fl_________________________
0:00______________________
0:00_____________________ 1n
n.nn
1pm
2-19-92 JOE RODRIGUEZ 0 0:00 0:00 0 o.oo
2-19-92 JOE RODRIGUEZ PER-A 7:45 11:00 195 tom 2.01
Flow Rate End Averaqe Flow Rate Volume
o. oo_________________tom
n.on
tom
n1
o. oo o.oo n
tom 2.0i tom 2.01
1 391.95
Date Analyzed Graticule Field Area Total Fibers/Fields
3-1Q-92________;__________ ?-!q-Q2
0.00785__________________ 0.00785
o / inn
2/100
2-19-92 0.00785
10/100
Averaae Blank Fibers/Fields
? /1 nn
2/100
2/100
Fibers/Square mm Coefficient of Variation
o oo_____________________ 0. 00
0.00
0. 00
10.67 0.00
Fibers/cc
n
0
<0.011
8 HR TWA
0
0
0.008
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room,
STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
1
Comments:
Analyzed by: rglcer fay Typist's Initials: J.R.
SWRflAsbestos 3594
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
Client: SOUTHWESTERN REFINING CO., INC.
NWE Job Number: 8064
Attention: BARBARA POPE
Report Date: 2-19-92
Contractor: GILMAN insulation CO., INC.
Report Number: 3
Project: CAT # 1 STAIRWAY COLUMN ENCLOSURE L GLOVEBAG
Page: 2 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples wlil be returned In 30 days if we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
AD-4 021992AD4 AREA OUTSIDE ENCLOSURE EXIT GROUND FLOOR
AD-5 021992AD5 AREA OUTSIDE ENCLOSURE EXIT 2ND. FLOOR
CR-6 0219920Kb AREA 1 NS 1 uE L>LCUIM CLEAN ROOM
Work Being Performed (respirator, if applicable)
GROSS REMOVAL
GROSS REMOVAL
N/ A
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-19-92 JOE RODRIGUEZ PER-1033 7:45 15:20 455 3.08 3.08 3.08 1401.4 2-19-92 0.00785
7/ 100 2/100 6.36 0. 00 <0.002 0
2-19-92 JOE RODRIGUEZ PER-B 7:45 15:20 455 Ipjn 3.08 1pm 3.08 1pm 3.08 1 1401.4 2-19-92 0.00785
9/100 2/100
8.92 0. 00 <0.002 0
2-19-92 JOE RUDKtGUEZ PER-C /: 4b 15:20 45b
ipm ipm 1pm
1 1401.4 2-19-92 0.0078b 79/100 2/100 98. 09
1 4. 0. Ubb 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
bin bin
bm
i
Comments:
Analyzed by: DODGER Fay Typist's Initials: J'R-
SWRf/Asbestos 3595 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
Client: SOUTHWESTERN REFINING CO.. INC. Attention: BARBARA POPE Contractor: GILMAN INSULATION CO.. INC.
Project: CAT # 1 STAIRWAY COLUMN ENCLOSURE
NWE Job Number:
Report Date:
Report Number:
GL0VEBAG
Page:
8064 2-19-92 3
3 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposn.cn; Ycur
wlj: be returned n 30 days rf wo do not receive a Signed lorlo' ajtbo::z,ng CiSDOsaJ.
Sample ID Number Laboratory Number Type of Sample Location of Sample
P-7 G21992P7 PERSONAL RAY WITHERSPOON 466-69-9535
C-8 021992C8 CLEARANCES INSIDE ENCLOSURE GROUND FLOOR
C-8A 021992C8A "CLEARANCES INSIDE ENCLuSUkE 2ND. FLOOR
Work Being Performed (respirator, if applicable)
Date Sampled Sampled Bv Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
GLOVE BAG
HALF MASK 2-19-92 JOE RODRIGUEZ F'ER-D 8:30 11:00 150 2.01 2.01 2.01 301.5 2-19-92 0.007B5
7/100 2/100 6.37 0. 00 <0.008 0. 011
N/A
2-19-92 JOE RODRIGUEZ HV-202 13:40 15:20 100 to 15.00 ^ni 15.00 lum 15.00 1 1500 2-19-92 0.00785
10.5100 2/100
32.48 1.42 0.006 0
"TTTfi --
~
2 - 19 - y 2
JUE KUDk1GUEZ
HV-93
18:40
lb:20
TUS
to ~n37OT iom
to 1 1500
iS
to is
j
2-19-92
0.00785
--
17/100
2/100
0. 00
~
0.00
~0 ~ ~o---------------------------------- --
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room,
STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments' SAMPLE If C-8A was added WITH sample C-8 .
Analyzed by: Jlj!1 P-ODR IGUEz Typist's Initials: J . R
SWRf/Asbestos 3596 -- Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
_________ Air Sample Analysis Report__________
Ciient: SOUTHWESTERN REFINING CO.. INC.
NWE Job Number: 8064
Attention: Barbara POPE
Report Date: 2-19-92
Contractor: G;LMAN insulation CO.. INC.
Report Number: 3
Project: CAT # 1 STAIRWAY COLUMN ENCLOSURE & GLQVEBAG
Pa9e; 4 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Samae Disposeion: Year sables will be relumed in 30 days it we Go no! 'ocofve a Signed letter aphorizing disoosaJ
Sample ID Number Laboratory Number Type of Sample Location of Sample
3TE-10 021992STE10 SHORT TERM EXP0SUE RAY WITHERSPOON 466-69-9535
P-9 021992P9 PERSONAL ERASMO MARTINEZ 455-25-8425
P-11 021992P11 PERSONAL RAY WITHERSPOON 466-69-9535
Work Being Performed (respirator, if applicable)
GLOVE BAG
GLOVE BAG
GLOVE BAG
Date Sampled
HALF MASK 2-1Q-Q?
HALF MASK 2-19-92
HALF MASK 2-19-92
Sampled By Pump No. Time Started Time Ended Total Minutes Sampled
.TOE RODRIGUEZ PFR-1035 12; 5Q_____________________ 13:20_____________________ 30
JOE RODRIGUEZ PER-1041 12:50 18:10 290
JOE RODRIGUEZ PER-A 13:20 18:10 260
Flow Rate Start
2.41
tom 2.01
tom 2.01
Flow Rate End
2.41
tom 2.01
tom 2.01
Averaae Flow Rate
2.41
tom 2.01
tom 2.01
Volume Date Analyzed
_________________ L_ 582.9 2-19-92__________________ 2-20-92
1 522.6
Graticule Field Area Total Fibers/Fields
0.00785 5/TOO
0.00785 9/100
0.00785 16.5/100
Averaae Blank Fibers/Fields Fibers/Square mm Coefficient of Variation
2 .TOO_________________
2/100
3.82
8.92
0.00
0.00
2/100 18.47 0. 00
Fibers/cc
<0.02
<0.006
0.014
8 HR TWA
0.011
0.008
0.011
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
1
Comments: SAMPLES ti 9 l< P-11 WERE TURNED OFF FOR 50 MIMS.
_ SWRf/Asbestos 3597
Analyzed by: RODGER FAY Typist's Initials: J.R.
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
Client: southwestern refining co..inc. Attention: Barbara pope Contractor: G!LMAN INSULATION CO.. INC.
Project: crude UNIT - T3 . BOILERS . & PIPERACK
NWE Job Number: 8064 Report Date: 2-20-92
Report Number: 4 Page: 1 of:
3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
B-i 022092B1 BLANK N/A
Samde Disposition: Your samples will be returned in 30 days It we do not receive a signed letter authorizing disposal.
e-2
022092B2 BLANK N/A
P-3 022092P3 PERSONAL ERASMO MARTINEZ 455-25-8425
Work Being Performed
N/A
N/A
GLOVE Bag
(respirator, if applicable)
Date Sampled
^-70.-Qr:
2-20-92
HALF MASK 2-20-92
Sampled By Pump No.
j n f 0 n D b i g u e 7. 0
JOE RODRIGUEZ 0
JOE RODRIGUEZ PER-A
Time Started
n i nn
0:00
12:50
Time Ended Total Minutes Sampled
!'): no o
0:00 0
15:30 160
Flow Rate Start
o, no
lpm 0.00
lpm 2.01
Flow Rate End Averaqe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
o.oo__________________ Sm.
o.oo
1pm
o1
0.00785__________________ 1.5/100
1.25/100________________ 0.00 0,00 0 0
o.oo o.oo o
2-20-92 0.00785
1/100 1.25/100 0. 00 0.00 0 0
lpm 2.01 lpm 2.01
1 321.6 o _ i o _ ci 9
0.00785 11/100
1.25/100 12.42 0.00 <0.015 0.011
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
lcm lnm tom
1
Comments:
Analyzed by: JOE RODRIGUEZ Typist's Initials: J.F..
SWRflAsbestos 3598
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
Client: SOUTHWESTERN REFINING CO.. INC. Attention: Barbara POPE Contractor: GILMAN INSULATION CO.. INC.
Project: CRUDE UNIT - T3 , BOILERS . & PIPERACK.
NWE Job Number: 3064 Report Date: 2-20-92
Report Number: 4 Page: 2 of:
3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned in 30 days if we do not recewe a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
Work Being Performed (respirator, if applicable)
AD - 4
022092AD4 AREA DOWN WIND FROM GLOVE BAG TASK BY T3 PIPES GLOVE BAG
Date Sampled
2-20-92
Sampled By
JOE RODRIGUEZ
Pump No.
PER-1033
Time Started
12:50
Time Ended
15:30
Total Minutes Sampled
1 160
Flow Rate Start
3.08
Flow Rate End
3.08
Averaqe Flow Rate
-3.08
Volume
492.8
Date Analyzed
2-20-92
Graticule Field Area
0.00785
Total Fibers/Fields Averaqe Blank Fibers/Fields
12.5/100 1.25/100
Fibers/Square mm Coefficient of Variation
14.33 1. bl
Fibers/cc 8 HR TWA
0. 018 0
AD-5 G22092AD5 AREA DOWN WIND FROM GLOVE BAG TASK BY BOILER PIPES GLOVE BAG
P-6 Q22092PS PERSONAL JESUS MATA 460-43-0216
GLOVE
2-20-92
JOE RODRIGUEZ P ER-i041 12:50 18:30 340
l^xn 3.0b 1pm 3.08 1pm 3.0b
1 1047.2 2-21-92 0.00785 7.5/100
1.25/100 7.96 0.00 <.0. U03 0
HALF MASK
2-20-92
JOE RODRIGUEZ
ptk-i035
"12:50
15:30
160
1pm ^ ` 01 1pm **Ui 1pm ^-'->1
J 321.6
Ipm
lum ipm
j
2-20-92
0.00735
11/1UU
f. 25/100--------------------------
12.42 --------------------------o.uu -------------------------
<..u. UlO
..U.UUb ---------------------------
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: J'Cl- RODRIGUEZ Typist's Initials: J . ?. .
SWRf/Asbestos 3599 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
Client: SOUTHWESTERN REFINING CO.. INC. Attention: BARBARA POPE Contractor: GILMAN INSULATION CO., INC.
Project: CRUDE UNIT - T3 . BOILERS . & PIPERACK
NWE Job Number: 8064 Report Date: 2-20-92
Report Number: 4 Page: 3 of: 3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
SamcJo Dspcsil'on: Your
wii be relumed n 30 days :1 we Co no! rece.ve a signed tet'er authoring cisoosa!
Sample ID Number Laboratory Number Type of Sample Location of Sample
P-7 022G92P7 PERSONAL ERASM0 MARTINEZ 455-25-8425
P-8 022092P8 PERSONAL JOSE MEZA 450-81-5590
STE-9 U22092STE9 SHORT TERM EXPU5UE EKASHU MARTINEZ. 455-25-8425
Work Being Performed
GLOVE BAG TASK.
GLOVE BAG TaSR
G L 0 v t Bag i a e r
(respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaqe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
HALF MASK 2-20-92 JOE RODRIGUEZ PER-A 17:10 18:30 SO 2.01 2.01 2.01 160.8 2-21-92 0.00785
9.5/100 1.25/100 10.51 u. 00 <.0. 025 0.011
HALF MASK 2-20-92 JOE RODRIGUEZ PER-1035 16:50
18:30 100
ipm 2.01 ipm 2.01 ipm 2.oi
1 201
2-21-92
0.00785 26.5/100
1.25/100 32. 17 0.00 0. 0b2 0.012
HALF MASK 2-20-92 JOE RUDR1GUEZ RER-B 16 : 40 1 /: 10 30
ipm ",41 ipm 2,41 ipm 2 41
1 /2.3 2-2U-92 0.O07S5 b.5/100 1.25/100 b. b9 0. UO <U.Uob 0. Ol 1
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Ipm 1pm
ipm
j
Comments:
Analyzed by:
RODRIGUEZ
Typist's Initials: J . R.
SWRf/Asbestos 3600 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________ Air Sample Analysis Report__________
Client: SOUTHWESTERN REFINING CO.. INC. Attention: Barbara POPE Contractor: GILMAN insulation CO.. INC.
Project: CRUDE UNIT - T3 , BOILERS . & PIPERACK
NWE Job Number: Report Date:
Report Number:
Pa9e:
6064 2-21-92 5
1 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
B-i 022192B1 BLANK N/A
Work Being Performed (respirator, if applicable)
N/A
SamcJe DiSoos^ion: You' samples w:il be rovj'nec ^ 30 days ? wo oo not rocsrvo a signed iefer authorizing csoosa.
B-2 022192R2 BLANK N/A
N/A
AD-3 022192AD3 AREA DOWN WIND FROM GLOVE BAG TASK BY BOILER PIPES GLOVE BAG
Date Sampled Sampled By Pump No.
-92
JOE RODRIGUEZ 0
2-21-92 JOE RuDFvIGUEZ 0
2-21-92 JOE RODRIGUEZ PER-1041
Time Started Time Ended Total Minutes Sampled
0:00 0:00 1o
0:00 0:00 0
8:40 12:10 210
Flow Rate Start
o.oo
1cm o.oo
1cm 3.08
Flow Rate End
o .oo
1cm o.oo
1cm 3.08
Averaae Flow Rate Volume Date Analyzed
o .no 7-9 t -G9
lum o.oo 1o 2-2i"92
1cm 3.08 1 646.8 2-21-92
Graticule Field Area
O.00785
0.00785
0.00785
Total Fibers/Fields Averaae Blank Fibers/Fields
1 / 100 1/100
1/100 1 /100
9/100 1/100
Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
0.00 0.00 0 0
0.00 0.00 0 0
10. 19 0.00 <0.006 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
1pm 1pm 1pm
1
Comments:
Analyzed by: JOE RODRIGUEZ Typist's Initials: J.E.
SWRf/Asbestos 3601 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
dient: southwestern refining co.. inc. Attention: baRBara pope Contractor: ^ i lkan INSULATION CO.. INC.
Project: CRUDE UNIT - T3 . BOILERS . & PIPERACK
NWE Job Number: 8064 Report Date: 2-21-92
Report Number: 5 Pa9e: 2 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your Bampleswill be relumed In 30 days if W8 do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number
P-4 09?1Q9P4
AD-5 022192AD5
P -6 022192P6
Type of Sample Location of Sample
PERSONAL JOSE MEZA 450-81-5590
AREA DOWN WIND FROM GLOVE BAG TASK
PERSONAL RAY WITHERSPOON 466-69-9535
BY BOILERS
Work Being Performed (respirator, if applicable)
GLOVE BAG
GLOVE BAG
GLOVE BAG
Date Sampled Sampled By
HALF MASK
2-21-92 j df pnnp i i'iUFv
2-21-92 JOE RODRIGUEZ
HALF MASK . 2-21-92
JOE RODRIGUEZ
Pump No.
p p P. ~ ft
PER-1035
PER-C
Time Started
ft: 30
8:30
8:30
Time Ended Total Minutes Sampled Flow Rate Start
10:30 1 90
2.01
10:30 120 ltim 3.08
10:30 120 tom 2.01
Flow Rate End Averaae Flow Rate
2.01 2.oi
1cm 3.08 tom 3.06
lpm 2.01 tom 2.01
Volume Date Analyzed Graticule Field Area
180.9
'-21-92 0.0078,5
1 3SSi6 2-21-92 0.00735
l 241.2 2-21-92 0.00735
Total Fibers/Fields Averaoe Blank Fibers/Fields
32/100 ! / 100
7/100 1/100
30.5/100 1/100
Fibers/Square mm Coefficient of Variation
39,49 0. 00
7.64 0. 00
37.57 0.00
Fibers/cc
0.034
<0.008
0.06
8 HR TWA
0.068
0
0.015
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
tom tom tom
1
May Represent Exposure to:
Comments: F'ERSuNN-L RESULTS MAY BE HIGHER. BECAUSE WORKING WITH INSULATION. SAMPLE A p-A WAS TUP.N OFF FOR 60 NINS.
R GLASS
Reviewed and Approved by:
Analyzed by: JOE ROOF: i SUEZ
Typist's Initials:
SWRf/Asbestos 3602
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
Client: southwestern refining co.,INC. Attention: Barbara pope
Contractor: oilman INSULATION CO., INC. Project: CRUDE UNIT - T3 . BOILERS . & PIPERACK
NWE Job Number: Report Date:
Report Number: Page:
8064 2-21-92 5
3 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned in 30 daysifwe do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
AD-7
rP?jg2AD7 AREA DOWN WIND FROM
STE-8 022192STE8 SHORT TERM EXPOSUE JOSE MEZA
P-9 022192P9 PERSONAL MARTIN MARTINEZ
GLOVE BAG TASK
450-81-5590
463-15-9333
Work Being Performed
BY BOILERS GLOVE BAG
GLOVE BAG
GLOVE BAG
(respirator, if applicable)
HALF MASK
HALF MASK
Date Sampled
?-9 i -92
2-21-92
2-21-92
Sampled By
,inF RODRIGUEZ
JOE RODRIGUEZ
JOE RODRIGUEZ
Pump No.
PFP-'041
PEP.-A
PER-B
Time Started Time Ended
12:10 1 = ^40
13:10 13:40
13:40 16:00
Total Minutes Sampled Flow Rate Start Flow Rate End Averaqe Flow Rate
710
. 08
op,
?,. op
30
lwn 2.41 lwn 2.41 lwn 2.41
260
lwn 2.01 lwn 2.01 lwn 2.01
Volume
ftift . ft
l 72.3
1 522.6
Date Analyzed Graticule Field Area
-G2 O.00785
2-21-92 0.00785
2-22-92 0.00785
Total Fibers/Fields Averaqe Blank Fibers/Fields
11/100 1/100
5/100 1/100
61/100 1/100
Fibers/Square mm Coefficient of Variation
12.73 1.64
5.09 0. 00
76.43 0.00
Fibers/cc 8 HR TWA
0.012 0
<0.027 0.068
0.056 0.03
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
lnm lwn lwn
1
May Represent Exposure to:
Comments:
Analyzed by: J0c RODRIGUEZ Typist's Initials: J.R.
SMfIAsbestos 3603
Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________ Air Sample Analysis Report__________
Client: SOUTHWESTERN REFINING CO., INC. Attention: Barbara pope Contractor: G;lMAN insulation CO.. INC.
Project: crude UNIT - T3 , BOILERS . &< PIPERACK
NWE Job Number: Report Date:
Report Number: Pa9e:
8064 2-21-92 5
4 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned In 30 days if we do not receive a signed letter aulhorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
P-10 022192P10 PERSONAL JOSE MEZA 450-81-5590
Work Being Performed (respirator, if applicable)
xj L 0 V E B A (j
Date Sampled
HALF MASK 9-9 1 -*2
Sampled By Pump No. Time Started
JOE RODRIGUEZ PER-1035 13:40_____________________
Time Ended Total Minutes Sampled
18:10_____________________ 270
Flow Rate Start
2.01
1pm
1pm
Flow Rate End
2.oi
lnm
1pm
Averaae Flow Rate
t oi
lnm
1pm
Volume Date Analyzed
S42.7__________________ L_
1
Graticule Field Area Total Fibers/Fields
0.00785 72/100
Averaae Blank Fibers/Fields
1 / 1 00
Fibers/Sauare mm
QO. 44
Coefficient of Variation
0,00
Fibers/cc
0.064
8 HR TWA
0.068
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
1pm 1pm 1pm
1
Comments:
Analyzed by: J 0E huDR i SUEZ Typist's Initials: J.R.
SWRf/Asbestos 3604 Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client. SOUTHWESTERN REFINING CO.. INC. Attention: BAR0ara POPE
Contractor: GiLMAN INSULATION CO.. INC. Project: CRUDE UNIT - T3 , BOILERS . PIPERACK
NWE Job Number:
Report Date: Report Number:
Page:
qqq4
2-22-92 g
1 of:
a
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
B-l 022292B1 BLANK. N/A
Work Being Performed (respirator, if applicable)
N/A
Sarriole Disoosilicn: Yoa' Sana,os will be returned ;n 30 cays rf we do nc! recede a signed letter authorizing disposal
B-2 022292B2 BLANK N/A
N/A
AD-3 022292AD3 AREA DOWN WIND t'RQM GLOVE BAG TASK BY BOILERS GLOVE Bag
Date Sampled Sampled Bv Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaqe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-22-92 JOE RODRIGUEZ 0 0:00 0:00 0 0.00 0.00 o. oo 0 2-22-92 0.00785
2/100 1.5/100 0.00 0.00 n
0
1pm lpm lpm
1
2-22-32 JOE RODRIGUEZ 0 0:00 0:00 0
0 00 o. oo o.oo o 2-22-92 0.00785
1/100 1.5/100 0.00 0.00 0 0
lpm ipm lpm
1
2-22-92 JOE RODRIGUEZ PER-1035 8:10 11:20 190 3.08
3.08 3.08 585.2 2-22-92 0.00785
9.5/100 1.5/100 10. 19 0.00 'to. 006 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
iDm
lpm lpm
1
May Represent Exposure to:
Comments:
Analyzed by: J - - nULiR i --u=.z. Typist's Initials: r -
SWRf/Asbestos 3605 Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
Client: SOUTHWESTERN REFINING CO.. INC Attention: Barbara POPE Contractor: GILMAN INSULATION CO., INC.
Project: CRUDE UNIT - T3 , BOILERS . b PIPERACK
NWE Job Number: 8064 Report Date: 2-22-92
Report Number: 6 Page: 2 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Tota! Fibers<1300 f/mm2
Sample Disposition: Your samples wl!l be returned In 30 days rl we do not receive a signed letter aulhorizing disposal.
Sample ID Number Laboratory Number Tvoe of Sample Location of Sample
AD-4 022292AD4 AREA DOWN WIND FROM GLOVE BAG TASK
P-5 022292P5 PERSONAL JES'uS MATA 460-43-0216
P-6 022292RS PERSONAL NOE GARC1A 450-15-7939
Work Being Performed
BY BOILERS (jLQ 'v L ? AG
GLOVE BAG
GLuVE BAG
(respirator, if applicable)
Date Sampled
2-22-3^
Sampled By
JOE RODRIGUEZ
Pump No.
PER-1033
Time Started
8:30
Time Ended
11:20
Total Minutes Sampled
170
Flow Rate Start
3.08
Flow Rate End
3.08
Averaqe Flow Rate
3.08
Volume
1 523.6
Date Analyzed
2-22"92
Graticule Field Area
0.00785
Total Fibers/Fields
11/100
Averaqe Blank Fibers/Fields
1.5/100
Fibers/Sauare mm
12.10
Coefficient of Variation
0.00
Fibers/cc
v0.009
8 HR TWA
0
HALF MASK 2-22-92 JOE RODRIGUEZ
PER-B 8:10 11:20 160 tom 2.01 hm 2.oi tom 2.01 1 321.6 2-22-92 0.00785 15.5/100
1.5/100 17.63 0.00 0.021 0.013
HALF MASK 2-22-92 JOE RODRIGUEZ PER-A 8:10
11:20 160
1pm 2-01 tom 2-01 tom 2-01
1 821.b 2-22-92 0.O0785 00 1.5/lOo 0. 00 0.00
SAMPLE TO DiRTY o
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
tom iDm [Dm
1
May Represent Exposure to:
Comments:
MPLi.3 # P-5 b F-6 WEkE TURNED OFF FOR 30 MINS.
SWRf/Asbestos 3606
Analyzed by: Typist's Initials:
r:->^r '-1
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO.. INC. BARBARA POPE GILMAN INSULATION CO.. INC. CRUDE UNIT - T3 , BOILERS . & PIPERACK
NWE Job Number: Report Date:
Report Number: Page:
8064 2-22-92 6
3 Of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Drsposlllon: Your samcles will be relumed in 30 days il we do not racer/o a signed letter authorizing disposal.
Sample ID Number Laboratory Number Tvoe of Sample Location of Sample
Work Being Performed (respirator, if applicable)
AD-7 022292AD7 AREA DOWN WIND FROM GLOVE BAG TASK BY T3 PIPES GLOVE BAG
AD-8 022292AD8 AREA DOWN WIND FROM GLOVE BAG TASK BY T3 PIPES GLOVE BAG
STE-9 022292STE9 SHORT TERM EXPOSUE JESUS HATA 460-43-0216
GLOVE BAG HALF MASK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaqe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-22-92 JOE RODRIGUEZ PER-1035 12:50 18:10 320 3.08 3.08
3.08 985.6 2-23-92 0.00785
7.5/100 1.5/100 7.64 0.00 <0.003 0
iDm 1pm
1pm 1
2-22-92 JOE RODRIGUEZ PER-1033 12:50 18:10 320 3.08 3.08 3.08 985.6 2-23-92 0.00785
8.5/100 1.5/100 8.91 0.00 <0.004 0
1pm 1pm 1pm
1
2-22-92 JOE RODRIGUEZ PER-D 12:50 13:20 30
2 41 2*41 2,41 7273 2-23-92 0.00785
6/100 1.5/100 6.37 0750 <0.034 0.013
Abbreviations: AP-Area sample prior to abatement, AD-Area sample durina abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
j
Comments:
Analyzed by: Typist's Initials:
RODRIGUEZ J. R.
SWRf/Asbestos 3607 Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________Air Sample Analysis Report__________
Client: SOUTHWESTERN REFINING CO. , INC. Attention: BARBARA POPE Contractor: GILMAN INSULATION CO., INC.
Project: CRUDE UNIT - T3 . BOILERS , PIPERACK
NWE Job Number: S064 Report Date: 2-22-92
Report Number: 6 Page: A of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
P-10 022292P10 PERSONAL NOE GARCI A 450-15-7939
Sample Deposition: Your &ie6 will be returned In 30 days il we do nol receive a signed letter authorizing disposal.
P-11 022292P11 PERSONAL JESUS MATA 460-43-0216
Work Being Performed
GLOVE BAG
GLOVE BAG
(respirator, if applicable)
HALF MASK
HALF MASK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Sauare mm Coefficient of Variation Fibers/cc 8 HR TWA
2-22-92 JOE RODRIGUEZ PER-B 12:50 18:10 290 2.01 2.01 2.01 582.9 2-23-92 0.00785 25.5/100
1.5/100 30.57 0.00 0.02 0. 018
2-22-92 JOE RODRIGUEZ PEP.-A 13:20 18:10 260 1pm 2.01 1pm 2.01 1pm 2.01 1 522.6 2-23-92 0.00785
10/100 1.5/100 10. 83 0.00 <0.008 0.013
1pm bm bm
1
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
1
Comments: ^Ai-iFLzlft .*-1 L ril WERE TURNED UbF FUK du NINE.
SWRflAsbestos 3608
Analyzed by: J u - u u"' Typist's Initials: J
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO.. INC. Attention: 3arbara POPE
Contractor: GILMAN INSULATION C0.. INC. Project: cat # 1 - # l - P - 2
NWE Job Number: Report Date:
Report Number: Page:
8064 2-24-92 7
1 of:
2
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Tvoe of Sample Location of Sample
B-i 022492B1 BLANK N/A
Work Being Performed (respirator, if applicable)
N/A
Sample Disposition: Your samples will be returned in 30 days If we do not receive a signed letter authorizing disposal.
E-2 022492B2 BLANK N/A
N/A
AD-3 022492AD3 AREA DOWN WIND FROM GLOVE BAG TASK SOUTHS IDE GLOVE BAG AND ACM CLEAN UP
Date Sampled Sampled By Pump No. Time Started
2-24-92 JOE RODRIGUEZ 0 0:00
2-24-92 JOE RODRIGUEZ 0 0:00
2-24-92 JOE RODRIGUEZ PER-B 14:05
Time Ended Total Minutes Sampled Flow Rate Start
0:00 0 o.oo
0:00 0 tom o.oo
15:15 70 tom 3.06
Flow Rate End Average Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Average Blank Fibers/Fields Fibers/Sguare mm Coefficient of Variation Fibers/cc 8 HR TWA
0.00 o.no o 2-2^-92 0.00785
1 /100 1/100 0. 00 0.00 0 0
tom o.00 tom o.oo
lo 2-24-S2 0.00735 1/100 1/100 0. 00 0.00 0 0
tom 3.OS tom 3.08
1 215.6 2-24-92 0.00735 4/100 1/100 3.82 0.00 <0.007 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, UR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
tom tom tom
1
May Represent Exposure to:
Comments:
Analyzed by: JOE RODRIGUEZ Typist's Initials: J--"--
SWRf/Asbestos 3609 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO., INC. Attention: BARBARA POPE
Contractor: GILMAN INSULATION CO.. INC. Project: cat # i - # i - p - 2
NWE Job Number: Report Date:
Report Number: Page:
8064 2-24-92
7
2 of:
2
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned in 30 days if we do not receive a signed letter authorizing disposal.
Sample ID Number
AD-4
P-5
Laboratory Number
022492AD4
022492P5
Type of Sample
AREA
PERSONAL
Location of Sample
DOWN WIND FROM
MANUEL LIRA
GLOVE BAG TASK
561-31-6110
NORTHS IDE
Work Being Performed
GLOVE BAG AND
GLOVE BAG AND
(respirator, if applicable)
ACM CLEAN UP
ACM CLEAN UP
HALF MASK
Date Sampled
2-24-92
2-24-92
Sampled By
JOE RODRIGUEZ
JOE RODRIGUEZ
Pump No.
PER-1035
PER-A
Time Started
14 :05
14:05
Time Ended
15:15
15:15
Total Minutes Sampled
1 70
70 I
Flow Rate Start
3.08
tom 2.01
1pm
Flow Rate End
3.08
torn 2.01
lpm
Averaae Flow Rate
I 3.08
tom 2.01
1pm
Volume
215.6
1 140.7
1
Date Analyzed
2-24-92
2-24-92
Graticule Field Area
0.00785
0.00785
Total Fibers/Fields
00
5.5/iOQ
Averaae Blank Fibers/Fields
1/100
1 / 100
Fibers/Sauare mm Coefficient of Variation
0. 00 0.00
9.27 0.00
Fibers/cc 8 HR TWA
0 0
<0.025 0.004
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
lpm 1pm lpm
1
May Represent Exposure to:
Comments:
MP1
AD-4 WAS AVOID BECAUSE IT WAS U
Analyzed by: ;-E Typist's Initials:
SWRf/Asbestos 3610 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client:quT'HUESTERN REFINING CO. . INC. Attention:BAREARA p0?e
Contractor:,- j LMAN t nsulat 10M CQ.. INC. Project:CAT # i - SKIRT & PIPES
NWE Job Number: 3054
Report Date: 2-24-92 Report Number: 3
Page: 1 of:
3.
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
2E-1 022492231 BLANK N/A
Work Being Performed (respirator, if applicable)
N/A
Sample Disposition: Your samplBSWill be returned In 30 days II we do not receive a signed letter authorizing disposal.
-> r- _ r,
0224922B2 BLANK N/A
N/A
2 AD - 1 0224922AD1 AREA DOWN WIND FROM GLOVE BAG TASK BY STRUCTURE b L Q V z. BAu
Date Sampled
2 " 2 44 - 9 2
Sampled By
ERNEST GONZALES
Pump No.
o
Time Started
0:00
Time Ended
0:00
Total Minutes Sampled
10
Flow Rate Start
o.oo
Flow Rate End
o.oo
Averaqe Flow Rate
o.oo
Volume
0
Date Analyzed
-24-92
Graticule Field Area
0.00785
Total Fibers/Fields
1/100
Averaae Blank Fibers/Fields
1/100
Fibers/Square mm
0.00
Coefficient of Variation
0.00
Fibers/cc
0
8 HR TWA
0
2-24-92 ERNEST GONZALES 0 0:00 0:00 0 lpm 0.00 lum o.oo 1pm 0.00 10 2-24-92 0.00785
1/100 i/100 0.00 0.00
o
2-24-92
ERNEST GONZALES
PER-1041
2U: 30
5:00
510
1pm lpm lpm
1
3.08 3.08 3.08 1570.8 2-25-92
0.00785
5/100
1/100
5.09
O. OO
<0.001
0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
1pm lDln iDm
J
Comments:
Analyzed by:--GOHZALcS Typist's Initials: i?--
SWRf/Asbestos 3611
!
Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client:SOUTHWESTERN REFINING CO. INC. AttentioniBARBARA POPE Contractor^ 1LMAN INSULATION CO.. INC,
ProjectlCAT # 1 - SKIRT k PIPES
NWE Job Number: 8064 Report Date: 2-24-92
Report Number: 8 Page: 2 of:
3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
2P-2 0224922P2 PERSONAL JOSE MEZA 450-81-5590
Sample Disposition: Your samples will be relumed In 30 days ifwe do no! receive a signed letter authorizing disposal.-
2STE-3 0224922STE3 SHORT TERM EXPOSUE ERASM0 MARTINEZ 455-25-8425
2P02 G224922P02 SHORT TERM EXPOSURE RAY WITHERSPOON 466-69-9535
Work Being Performed (respirator, if applicable)
GLOVE BAG HALF MASK
GLOVE BAG HALF MASK
PREP-WORK SKIRT HALF MASK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Average Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-24-92 ERNEST GONZALES PER-A 20:00 5:30 510 2.41 2.41 2.41 1229.1 2-25-92 0.00785
19/100 1/100
90 09
0.00 0.007 0.008
2-24-92 ERNEST GuN2AL.ES PER-B 22:00 22:30
30 tom 2.41 tom 2.4i tom 2.41
l 72.3 2-24-S2 0.00785 6/100 1/100 6.36 0.00 <0.034 0
2-24-92 ERNEST GONZALES PER-3 20:30 E : 00 375
tom 2 41 tom 2.41 tom 2.41
1 903.75 2-25-92 0.00785 14/100 1/100 16.56 0.00 0.007 0.006
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom iDm
iDm l
Comments:
Analyzed by:-Sf:--T GuNZALES Typist's Initials:
SWRf/Asbestos 3612 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane * Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client:SOUTHWESTERN REFINING CO.. INC. AttentioniBARBARA POPE Contractor^ I LMAN INSULATION CO.. INC.
Projects AT # 1 - SKIRT & PIPES
NWE Job Number: 8064 Report Date: 2-24-92
Report Number: 8 Page: 3 of: 3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned In 30 days if we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2STE03 0224922STE03 SHORT TERM EXF0SURE NOE GARCIA 450-15-7939
2AD01 0224922AD01 AREA IN MIDDLE OF SKIRT ON LADDER
Work Being Performed
PREP-WORK
(respirator, if applicable)
SKIRT-
HALF MASK
Date Sampled
2-24-92
Sampled By Pump No.
ERNEST GONZALES PE-B
Time Started
20:30
Time Ended
21: 00
Total Minutes Sampled
30
Flow Rate Start
2.4 i
Flow Rate End
2.41
Averaae Flow Rate
2.41
Volume
172.2
Date Analyzed
2-24-92
Graticule Field Area
0.00765
Total Fibers/Fields
9/ ICO
Averaae Blank Fibers/Fields
1/100
Fibers/Square mm
10. 19
Coefficient of Variation
0.00
Fibers/cc
<0.054
8 HR TWA
0
PREP-WORK SKIRT
2-24-92 ERNEST GONZALES
PER-1035 20:30 5:00 510 1pm 3.08 lpm 3.08 1pm 3.08 1 1570.6 2-25-92 0.00785
8/100 1/100 8.91 0.00 <0.002 0
1pm 1pm 1pm
l
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
1
Comments:
Analyzed by:-p-'j~T CUHZALeS Typist's Initials:
SWRf/Asbestos 3613 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO.. INC Attention: BARBARA POPE Contractor: GILMAN INSULATION CO. . INC.
Project: CAT # 1 - SKIRT ENCLOSURE b PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-25-92 9
l of:
5
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Tvoe of Sample Location of Sample
B- 1 Q22592B1 BLANK N/A
Sample Disposition: Your samples will be relumed In 30 days we do not receive a signed letter authorizing disposal.
B-2 022S92B2 BLANK N/A
AD-3
U22592AD3
~
AREA
"INSIDE SKiR'I------------------
ENCLOSURE
Work Being Performed
N/A
N/A
FKEP-WURK
(respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended
2-25-92 JOE RODRIGUEZ 0 0:00 0:00
Total Minutes Sampled Flow Rate Start
I0 0-00
Flow Rate End Averaae Flow Rate
o.oo
0.00
Volume Date Analyzed
0 2- 2d -92
Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
0.00785 1/100 1/100
0. 00 0. 00 0 0
2-25-92 JOE RODRIGUEZ 0 0:00 0:00 0 iDm 0.00
tom -00 lDm 0.00
1u 2-25-92 0.00735 1 / TOO 1/100 0.00 O.00 0
o
2-25-92
JOE RUDKIGUhZ
PER-1035 b: oO
14:10
340
iDm 3`01
iron
lmn tom
icm d-ul
lorn
l 1023.4
i
2-25-92--------------------- '--
0.00 /db
25/loo
--
1/100
30.5/
1.4b
O.Olb
0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room,
STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: Typist's Initials:
SWRf/Asbestos 3614 Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO., INC. Attention: BARBARA POPE Contractor: GILMAN INSULATION CO. , INC.
Project: CAT 8 1 - SKIRT ENCLOSURE L PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-25-92 9
2 of:
5
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Deposition: Your samples will be returned In 30 days if we do not receive a signed letter authorizirg disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
Work Being Performed (respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Average Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
AD-4 022592AD4 AREA DOWN WIND FROM GLOVE BAG TASK BY STRUCTURE GLOVE BAG
2-25-92 JOE RODRIGUEZ PER-1033 8:30 10:45 135 3.01 3.01 3.01 "06.35 2-25-92 0.00785
6/100 1/100 6.37 0.00 <.0. 006 0
P-5 022592P5 PERSONAL HORACIO CUEVAS 453-99-7182
GLOVE BAG PIPE RACK HALF MASK 2-25-92 JOE RODRIGUEZ PER-1U41 8:30 10:45 135 tom 2.01 tom 2.01 tom 2.oi I 271.35 2-25-92 0.00785
12/100 1 /1 Ou
14.01 0. UO
0. oz
o. ooy
P-6 022592P6 PERSONAL MANUhL LIRA 561-31-6110
PREP-WORK SK I RT HALF MASK 2- 25-y2 JOE RODRIGUEZ PER-A 8:30 10:45 135
tom 2-Ul tom tom
1 2/1.85 2-25-92 0.00755 28/100 1/100 84.89 0.00 U. 049 o. b / y
tom toE tom
j
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room,
STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: Typist's Initials:
SWRf/Asbestos 3615 Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664
(206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO., INC. Attention: BARBARA ?0FE Contractor: gilman insulation C0..INC.
Project: CAT # 1 - SKIRT ENCLOSURE & PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-25-92 9
3 of:
5
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your Bampleswillba returned In 30 days it we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
P-7 022592P7 PERSONAL H0RACI0 CUEVAS 453-99-7182
P-8 022592P8 PERSONAL MANUEL LIRA 561-31-6110
P-9 ""022592P9-------------------------
PbRbONAL hOkAolU CUtVAS 453-99-7182
Work Being Performed (respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rale Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
GLOVE BAG BY TURBINS HALF MASK 2-25-92 JOE RODRIGUEZ PER-B 11:30 13:10 100 2.oi
2.01 2.01 201 2-25-92 0.00785
8/100 1/100 8.92 0.00 <0.017 o.oos
GROSS REMOVAL
SKIRT P.A.P.R 2-25-92 JOE RODRIGUEZ PER-1041
14:10 15:35 85 tom 1-71 tom !-71 tom 1 71 1 145.35 2-25-92
0.00785 176/20 i/100
1119.74 0.00 2.9/ 0 . b id
GLOVE BAG
BY TURBINS
HALF MASK
2-25-92 JUE RUUKiGUhZ
PEK-B
14:30
15:35-------------------------------
&5
tom 2'0i lcm -Z7m
tom J 180.65
tom
i!is j
2-25-92---------------------------
0.60785
00
1/100
0. oo---------------------------------
0. 00
0 u
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
SWRf/Asbestos 3616
Comments:
"r-
WORKER HA I1 WENT TO WORK
AVOIDED. BECAUSE FOREMAN DIDN'T INFORMED ME THAT I EE SKIRT ENCLOSURE.AFTER GLOVE BAGGING.
Analyzed by: Typist's Initials:
: -aii-AL^;.
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO.. INC. Attention: BARBARA POPE Contractor: GILMAN INSULATION CO., INC
Project: CAT ft 1 - SKIRT ENCLOSURE & PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-25-92 9
4 of:
5
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your 6amplBS will be retumad In 30 days ifwa do nowecelve a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
STE-10 022592STE10 SHORT TERN EXPOSURE MANUEL LIRA 561-31-6110
AD-11 022592AD11 AREA OUTSltlE SKIRT ENCLOSURE EXIT
AD-12 022b9ZAD12 Akt A DUWN WIND hKliM GLOVE BAG TASK BY TURBINS
Work Being Performed (respirator, if applicable)
GROSS REMOVAL
GROSS REMOVAL
(iLuvh yA(j
Date Sampled Sampled By
2-25-92 JOE RODRIGUEZ
Pump No.
PER-A
Time Started
15:35
Time Ended Total Minutes Sampled
16:05
8 30
Flow Rate Start
2.41
Flow Rate End Average Flow Rate
2.41 2.41
Volume
72.3
Date Analyzed
2-25-S2
Graticule Field Area
0.00785
Total Fibers/Fields Averaqe Blank Fibers/Fields
157/20 1/100
Fibers/Square mm Coefficient of Variation Fibers/cc
998.73 0.00 5.31
8 HR TWA
0
2-25-92 JOE RCjDRIGUtZ PER-10J5 14:10 18:10 240 iDm 3.oi lDm 3.oi tom 8.01 1 722.4 2-25-92 0.00785
18/100 1/100
21.66 i . 52 0 * Old 0
2-2b **y2 JOE RUDKlbUhi.
PER-1088
lb: 20
17 :5b
9b
torn 3 01 tom
iDm 01 1 2bb.9b
tom lum 1m
j
2-25-92
0.00 /8b
5/100
1/100
b. 09
0.00
<0.007-------------------------------
0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
SWRf/Asbestos 3617
Comments: SAHPL-. GIL
AMPLE it FOREMAN
STE-10 WAS OVER WAS INFORMED.HE
THE QSHA RULES TO EXCEED MADE CREW Tu CONTINUE TO
1.0 MIS
f / cc UN TE DOWN AREA..
Analyzed by: 0 - '`u -*1 ,J |J - Typist's Initials: J . R .
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client; SOUTHWESTERN REFINING CO. . INC. Attention: BAREARA POPE Contractor; GILMAN INSULATION CO. , INC.
Project: CAT * 1 - SKIRT ENCLOSURE k PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-25-92 9
5 of:
5
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned In 30 days H we do nol receive a signed tetter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
P-13 022592P13 PERSONAL J ESU5 MAT A SR. 459-43-8543
P-14 022592P14 PERSONAL MANUEL LIRA 561-31-6110
Work Being Performed (respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaoe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaoe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
GLOVE BAG BY TURBINS HALF MASK 2-25-92 JOE RODRIGUEZ PER-B 15:40 18:00 140 2.01 2.01 2.01 281.4 2-25-92 0.00785
21/100 1/100
25.4 7 0.00 0.035 0.01
WET DOWN INSIDE
ENCLOSURE SKIRT
P.A.P.R
2-25-92
JOE RODRIGUEZ
PER-1041
17:15
18:30
75
1pm 1.71
ipm
1pm 1 71
ipm
ipm i.7i 1 128.25
ipm 1
2-25-92
0.00785
6/100
1 /100
6.37
0. 00
0.04/
0.879
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Icm lent him
1
Comments:
Analyzed by: -K`Ntz,T Typist's Initials: J , K.
AL
SWRf/Asbestos 3618 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO: Attention: Barbara -PuF'E Contractor: GILMAN INSULATION CO: INC.
Project: CAT l SKIRT
INC.
NWE Job Number: 606 4 Report Date: 1-15-92
Report Number: 10 Page: l of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
5-1 6064022592 BLANK N A
Sample Disposition: Your iampleewillbe returned In 30 days# we do no! receive a signed letter authorizing disposal.
B-Z " h L' " o
B LAN r. N/A
area
uui51LE ELOLuELr.E DC OR
Work Being Performed
N/A
N/A
removal
(respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Sauare mm Coefficient of Variation Fibers/cc 8 HR TWA
2-25-32 ERNiE GONZALES 0.00 0:00 0:00 0
o.oo o.oo
o.oo
o
2-25*32 0.00785
1100 1100 0.00
ITTW, 0.00
2." ERNIE GONZALES 0*00 0:00 0:00 0
lcm o. oo 0.00
tan 0.00 l0 2-25-32 0 > 00*78s 1100 1100 u. 00 0.00 0.00 0.00
2-25-32 ERNIE GONZALES PER-D 19:55 25:00 i cb torn 3.05 lnm 3.05 lnm 3.05 1 56.4.25 2-25-92 0.00785
3100 1 iOO 8.91 0. 00 <.0060 0.00
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure-ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tan
tan lnm
1
Comments:
Analyzed by--Typist's Initials:
.
SWRf/Asbestos 3619 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SGUTHUnSTERN REFINING CC: Attention: Barbara pope Contractor: G1LMAN INSULATION CO: INC.
Project: Cat l SKIRT
INC.
NWE Job Number: 506Report Date: 2-25-92
Report Number: to Page: 2 of: a
Method of Analysis: NIOSH 7400 Method Specified Range.' 100<Total Fibers<1300 f/mm2
Sample Disposition: Your earcplee will be returned In 30 days* we do not receive a signed tetter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2-F-4 G 1J C' 4 G *_ 9 e^. PERSONAL ray weathers?gon 4bc-o;-'^:c:
2-5TE-8 3064U42592 CE i L I NiG RAY wEaTHERSPuON 46o-ss-acoc
l.~AD" f 3 0 o 4 'j--_ h 9 -- AP.EA UUT5iDE ENGLuoURE L U l r.
Work Being Performed (respirator, if applicable)
FAFE removal
P A P R r.EM 0 V A L
dAGuUT
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-25-92 ERNIE GuNZALES PER-5 la: 50 23:00 190
i.Ti l.Ti 1.71 324.9 2-25-92 0.00785
2S5100 1100
1614.01 0.00 2. 149 0. 550
2-25-92 ERN i c. GuL-ALtS PER-E 23:00
130 30 Iran i.7i Iran i. /1 Iran i.7i 1 51.3 2-25*92 0.00785
139100 1100
884.00 0. 00 6.634 0.00
ERNiE Gul2aLE
FER--J
Lj! v0
5: uu
360
inm 3.0 5
inm
inm 3.05 1 1095
.
~ . - " 9 *2
0.00785
8100
1100
6.91
0. 00
\ GGO i
0.00
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Inm
Iran I
Comments:
Analyzed by:fIvN': ,J' USAGES CMaA/'1
Typist's Initials:
S\NRf I Asbestos 3620 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING GO: Attention: Barbara -pope Contractor: G1LMAN i nsulat I ON CO: IMC.
Project: cat i sk I RT
INC.
NWE Job Number: 506 a Report Date: 2-L:-52
Report Number: 10 Page: 3 of:
a
Method of Analysis: NIOSH 7400 Method
Specified Range: 100<Total Fibers<1300 f/mm2 Sample Disposition: Your samplBswIII be retumedln 30 days It we do not receive a signed tetter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2-F-il 300402259.: PERSONAL RA* WtzAThrzKSPuuN 466-69 -95c3
i* . r\ur/ . ; 5u64o22592 AREA DOWN wiND
l* rv U "" 1 'J o 0 6 42 _ 5 2 2 AREA l'OWN WIND
Work Being Performed (respirator, if applicable)
i / 2 HAS k
N/A
h/ h
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaoe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaoe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-2j **2 ERNIE GONZALES FER-B 2:00 TUjO 160
1,71 1 >1 1 71 30/.6 2-23-92 0.00765
57 i 00 1100
71.53 O.O0
. UC'd
0. u 5 >
ERNIE G0NZA.LES ^ z.K~ 1 >j4 1 15:50 23:00
190
tom 3.05 tom S.Os tom 3.05
i 579.5 2-25-92 0.00765 4100
1100
3. 62
0.00 \. 0,J2w 0. 00
tom tom tom
1
2_-*:5-9 2 ERNIE GONZALES REF.- 104 i a. O \j L> 2:00 160
U.05 3.3)3 3.03 59 2-25-42 0.00765
6100
1100 6.36 0. uC x . 0*444
2.2 U
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom
tom l
Comments:
,,Analyzed by:^-I-RN-iE GONZALES
Typist's Initials:
SWRf/Asbestos 3621 Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: southwestern refining co: Attention: B arbara-pope Contractor: GILMAN ! NSULA7 S ON CO : INC.
Project: CAT i SKIRT
inc.
NWE Job Number: 506Report Date: 2-25-52
Report Number: 10 Page: 4 of: a
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Dfeposttion: Your samples will be returned In X days If we do not receive a signed letler authorizing dispose.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2-F -6 5064026592 PERSONAL rRaMuE MAn.7 1NEZ 4 w - - a. _ "
i. - STE- 9 6064022522 v L i L 1 N Lj ih.AI'lSU MART 1 Nc.Z
2-F-12
ouo4W.--522
PEP.DuNnL, - K A N 5 u M A r. i i i i z.
"-.-.a
Work Being Performed (respirator, if applicable)
i. 2 MASK
1/2 MASK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaqe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
4 - aO " i* u ERNIE GONZALES PER-A 19:45 23 4 00 195 2.41 a . 4: 2.41 469.95 2-25-92 0.00735
13100 1100
15.2 0. 00 . 0065 0.00-0
lpm lpm lpm
I
2-25-62 ERNIE GuNEALES PER-A 0; 00 0 30 aU
2.41 z.4i 2.41 72.3 2-25-92 0.CG7d5
6 1 a. 91 0. 00 . 04? 0.00
tiF.N i t GONZALES
r ER-.-.
0: 30
2:00
120
lpm c.4i
lum ->4i
lpm 2.41
1 283.2
.
4 " iL a " 2
0.00755
16100
1100
19. 1 u
0.00
. 025*4
c -JLoo
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation-The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
lpm
lpm lpm
1
Comments:
Analyzed by: Typist's Initials:
^
SWRf/Asbestos 3622 Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFiNIMG CO..iNC. Barbara fore GiLMAN INSULATION CO..INC. CAT # 1 - SKIRT ENCLOSURE & PI FES
NWE Job Number: Report Date:
Report Number: Page:
8064
2-26-92
11 1 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
Bl 022692B1 BLANK N/A
Sample Disposition: Your 6arrples will be relumed In 30 days if we do not receive a signed tenor authoring disposal.
B2 022692B2 BLANK N/A
AD3 0226S2AD3 AREA OUTSIDE ENCLOSURE EXIT
Work Being Performed
N/A
N/A
GROSS REMOVAL
(respirator, if applicable)
Date Sampled
V - '^-QO
2-26-92
2-26-92
Sampled By
JuE RQDR GUEZ
JOE RODRIGUEZ
JOE RODRIGUEZ
Pump No.
0
0
1035
Time Started
0:00
0 i 00
7:45
Time Ended
o on
0:00
16:00
Total Minutes Sampled
80
0
495
Flow Rate Start
o. oo
tom o.oo
tom 3.05
Flow Rate End
o.oo
tom o.oo
tom 3.05
Averaqe Flow Rate
o.oo
tom o.oo
tom 3.05
Volume
o 1 o 1 1509.75
Date Analyzed
2-26-92
y -yS -92
2-26-92
Graticule Field Area
0.00785
0.00785
0.00785
Total Fibers/Fields
1 / too
2/100
12/100
Average Blank Fibers/Fields
1.5/100
1.5/100
1.5/100
Fibers/Square mm
0. 00
0.00
13.38
Coefficient of Variation
0. 00
0.00
1.64
Fibers/cc
o
0
0.006
8 HR TWA
0
0
0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
tom tom tom
1
May Represent Exposure to:
Comments:
Analyzed by: Typist's Initials:
SWRflAsbestos 3623 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO., INC. BARBARA POPE GILMAN INSULATION CO. , INC. CAT # 1 - SKIRT ENCLOSURE & PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-26-92 11
2 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samplss will be returned In 30 days if we do nol receive a signedletter aulhorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
P4 022692P4 PERSONAL OSCAR GARCIA 449-29-0019
AD5 022692AD5 AREA ON BASKET
P6 022692P6 PERSONAL GUaDLUPE CERRITOS 430-65-8801
Work Being Performed (respirator, if applicable)
GROSS REMOVAL P.A.P.R
BAG MOVEMENT
BAG MOVEMENT HALF MASK
Date Sampled
2-26-92
2-26-92
2-26-92
Sampled By
JOE RODRIGUEZ
JOE RODRIGUEZ
JOE RODRIGUEZ
Pump No. Time Started
1034 7:45
1041 8:10
A 750
Time Ended
11:20
13:30
11:20
Total Minutes Sampled
185
320
200
Flow Rate Start
l.7i
iBra 3.05
ipm 2 4 l
Flow Rate End
1.71
tom 3.05
tom 2,41
Averaqe Flow Rate
1.71
tom 3.05
1pm 2 41
Volume
316.35
1 976
1 482
Date Analyzed
2-26-92
2-26-92
2-26-92
Graticule Field Area
0.00785
0.00785
0.00785
Total Fibers/Fields
110.5720
7/100
6.5/100
Averaqe Blank Fibers/Fields
1.5/100
1.5/100
1.5/100
Fibers/Square mm Coefficient of Variation
701.91 6760
7.01 67U0
6737 0766
Fibers/cc 8 HR TWA
0.854 0.6l7
7077163 0
<0.00b 0.014
Abbreviations: AP-Area sample prior to abatement. AD-Area sample during abatement. C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom
tom tom
[
Comments: SAMPLE ft P4 WAS TURNED OFF FOR 30 MINS.
Analyzed by: Typist's Initials:
J. R.
SWRflAsbestos 3624 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
S0UT HUE!:;tern refining co..inc. BARBARA POPE GILMAN 1 NSULATIQN CO.,INC. CAT # 1 - SKIRT ENCLOSURE & PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-26-92
11 3 Of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned In 30 days a we do not recede a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
Pti 022692P7 PERSONAL OSCAR GARCIA 449-29-0019
P? 022692P8 PERSONAL GUADLUPE CERRITOS 430-65-8801
STE9 022692STE9 SHORT TERM EXPOSURE OSCAR GARCIA 449-29-0019
Work Being Performed (respirator, if applicable)
GROSS REMOVAL P. A.P.R
GLOVE BAG AND BAG MOVEMENT
GROSS REMOVAL P. A. P . R
HALF MASK
Date Sampled
2-26-92
2"2S-92
2-26-92
Sampled Bv
J 0E r;C;DR i GUnZ
JGE RODRIGUEZ
JOE RODRIGUEZ
Pump No.
A
1034
1033
Time Started
12:50
12:20
12:20
Time Ended
16 :00
18:30
12:50
Total Minutes Sampled
190
330
30
Flow Rate Start
i.7i
him 2. a l
tom 2.41
Flow Rate End
i.7i
lam 2.41
1cm 2.41
Averaqe Flow Rate
1.71
tom 2.41
tom 2.41
Volume
324.9
1 795.3
1 72.3
Date Analyzed
2-2S-92
2-26-32
2-26-92
Graticule Field Area
0.00785
0.00785
0.00785
Total Fibers/Fields
101,5/21
31/100
41.5/100
Averaqe Blank Fibers/Fields
1.5/100
1.5/100
1.5/100
Fibers/Square mm
613.30
37.58
50.95
Coefficient of Variation
0. 00
0.00
0. 00
Fibers/cc 8 HR TWA
0.727 0.617
0.016 0.014
0.271 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom
tom
1
Comments:
Analyzed by: Typist's Initials:
j
SWRf/Asbestos 3625 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO..INC. BARBARA POPE GILMAN INSULATION CO..INC. CAT tt 1 - SKIRT ENCLOSURE S< PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064
2-26-92 11
4 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples willbe returned In 30 days K we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
P10 022692P10 PERSONAL VICTOR CASTILLO 607-20-9073
AD 11 022692AD11 AREA OUTSIDE ENCLOSURE EXIT
Work Being Performed (respirator, if applicable)
GROSS CLEAN UP P.A.P.R
GROSS CLEAN UP
Date Sampled Sampled By Pump No.
2-26-92
JOE RODRIGUEZ 4
2-26-92 JOE RODRIGUEZ 1035
Time Started Time Ended
1 6: A0 ! ft ; ;V
16:00 18:40
Total Minutes Sampled
110
1 60
Flow Rate Start
i.7i
tom 3.05
tom
Flow Rate End
i.7i
tom 3.05
tom
Averaqe Flow Rate
i.7i
tom 3.05
tom
Volume
188.1
1 488
1
Date Analyzed
2-26-92
2-26-92
Graticule Field Area
0.00785
0.00785
Total Fibers/Fields
1 OB.5/20
6.5/100
Averaqe Blank Fibers/Fields
1.5/100
1.5/100
Fibers/Square mm
670.06
6.37
Coefficient of Variation
0. 00
0.00
Fibers/cc 8 HR TWA
i * vj7 1.071
< 0.005 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
I
Comments:
Analyzed by: Typist's Initials:
SWRf/Asbestos 3626 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CC..iNC. Attention: Barbara.ROPE
Contractor: gilhan insulation co..inc. Project: cat # i skirt,piping
NWE Job Number: 606j, Report Date:
Report Number: ^ Page: < of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be retumedin 30 days II we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
Bi 02269231 BLANK N/A
E2 CZ2S92E2 BLANK N/A
s A. u -D
AREA_______________________ DOWN WIND OF GLuVb Bag
Work Being Performed
N/A
N/A
GLuVE BAG
(respirator, if applicable)
Date Sampled
2-26-92
2-26-92
Sampled By
E.GONZALES
E. GONZALES
E,GONZALES
Pump No.
0
0
PER-A
Time Started
0:00
u: 00
20:30
Time Ended
0:00
0:00
Zcj ; 00
Total Minutes Sampled Flow Rate Start Flow Rate End Averaoe Flow Rate Volume Date Analyzed
0
c.cc o.oo o.oo o
7 -7 -p /
0
torn 0.00 1cm o.oo lcra o. oo 1o
7 - 2 - 3 2.
150 1pm 2.53 1pm 2.83 lpm 2.S3
1 424.5
Graticule Field Area
0.00785
0.00785
0.00785
Total Fibers/Fields
1/100
1/100
6/ 100
Averaoe Blank Fibers/Fields
1/100
1 100
1 ! 1 00
Fibers/Square mm
0.00
0.00
6.36
Coefficient of Variation Fibers/cc 8 HR TWA
0. 00
0
0
0. 00
0
o
0.00
0.0057
0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation-The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
lpm tom tom
1
Comments:
Analyzed by: GONZALES , -- Typist's Initials: j'lR
SWRf/Asbestos 3627 Reviewed and Approved by:. Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFiNiNG CO.. INC. Attention: barlara.pope Contractor: g i lhan Insulation cg .. INC.
Project:cat t? l skirt,piping
NWE Job Number: S054 Report Date: 2-05-3;
Report Number: : 2 Page: 2 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: lOOcTotal Fibers<1300 f/mm2
Sample Disposition: Your Samples will be returned In 30 days H wo do not receive a slgnsd letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2F'4 0226922P4 PERSONAL erasmo Martinez 455-25-0425
021&S22STE5 SHORT TERM EXPOSURE erasmg Martinez 455-25-0425
2AD6 0226912AD6
AREA________________________ DOWN WIND OF GLOVE EAG
Work Being Performed (respirator, if applicable)
GLiu vt. BAu HALF MASK
b Li G V L Li A la HALF MASK
GLuvE bAG
Date Sampled
2-26-92
2-26-92
2-26-32
Sampled By
E.GGNZALES
E.GONZALES______________ E^-UijNZ.Abr.5_______________
Pump No.
PER-1041
PER-1041
PER-A
Time Started
21:00
0:00
0:50
Time Ended
23:00
0:30
5 :00
Total Minutes Sampled
120
30
270
Flow Rate Start
1.4?
tom 1.47
tom 2.33
tom
Flow Rate End
1.47
tom 1.47
tom .L. S3
tom
Averaae Flow Rate
1.47
tom 1.47
tom 2.83
tom
Volume
176.4
1 44.1
1 764.1
1
Date Analyzed
2-26-92
2-26-9Z
4-2g-92
Graticule Field Area
0.00765
0.00735
0.00735
Total Fibers/Fields
18/100
9/100
7/100
Averaae Blank Fibers/Fields
1/100
1/100
1 /100
Fibers/Sauare mm
21.65
10. 19
7.64
Coefficient of Variation
0.00
0.00
0.00
Fibers/cc 8 HR TWA
. 047 0.0116
. 088 0
. U'jjd 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure-ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: r
Typist's Initials:
3628 s^l^eStoS
Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO.. INC. Attention: p. a ?. b a ft a POPE
Contractor: G I LHAN INSULATION CO.. INC. Project: CAT S 1 SKIRT. PIPING
NWE Job Number: Report Date: i-is-32
Report Number: j.Page: .3 of:
u
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned in 30 days 'rf we do not recsVQ a sgned ierer avj'Sorizing disposal
Sample ID Number Laboratory Number Type of Sample Location of Sample
2P7 0226:s22P7 PERSONAL ERA.SMQ MARTiNEZ
455-25-0*2=
2 ADS D dL< j-sL.Z'6 -- r. PERSONAL UUT i DE Ur DOOR
c.NCLi- R
IPS 0225322P9 AREA N 0 E G A R CIA *+ w i j cf - r
Work Being Performed (respirator, if applicable)
<J L u V 21 D A L3 HALF MAK
REMOVAL CLEAN UP
REMOVAL CLEAN UF
F . A. P. R
Date Sampled
2-26-92
2-26-92
2-26-92
Sampled By
t. bOr'iZ.ALiiij
E. GONZALES
E. . is 0 i i L. r\ , w -
Pump No.
PER-1041
PER-1033
PER-E
Time Started
0:03
20:00
20:00
Time Ended
5:00
23:00
25:00
Total Minutes Sampled
297
160
180
Flow Rate Start
i. 4?
1pm 3.01
Iran 2.12
Flow Rate End
1.47
Iran 3.oi
Iran 2.12
Averaae Flow Rate
i. 4?
Iran 3.01
Iran 2.12
Volume
436.59
1 541.8
1 381.6
Date Analyzed
2-26-92
2-26-92
2-26-92
Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
0.00/6a 9/100 1/100
10. 19 0.00 . 0096 0.005E
0.00765 4/ 100 1/100
3. 82 0.00 . 0027 0
U.UU/CD 1 Ci 0 / 9 4 1/100
I54.24 0.00 . i55
0.05
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation-The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Inin Iran 1pm
l
Comments:
Analyzed by: O _ IN _ _ _ Z Typist's Initials:
SWRf/Asbestos 3629 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report__________
Client: SOUTHWESTERN' REFiNiNG CU..INC. Attention: Barbara. fope Contractor: gilman 'insulation co. , :nc.
Project: cat # 1 SKIRT. Pi PING
NWE Job Number: Report Date: c-cs-ps
Report Number:
Page: * of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sampls Disposition: Your tamplM will be relumed In 30 dayil we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2STE10 0 2 / S 9 2 2 3 7 E10 sHuR i i ERI1 t ar toURc NuE GARCIA 450-1S-7S3S
2AE' 11 0 2 2 9 A u11 AREA ON ENCLOSURE DOOR
IF 12 0226922P12
personal
noe Garcia 450-15-7939
Work Being Performed (respirator, if applicable)
removal Clean up ?.A.?.R
Rn-hiUVAL I-wE Ak Or
REMOVAL CLEAN UP F . A . F . P.
Date Sampled Sampled By
2-26-92 E.GONZALES
2-- 2 E* (juNZAL.t-5
2-26-22 E.GONZALES
Pump No. Time Started
PER-B 12:00
PER-1033 0:00
F Eh-5 \j t Gtj
Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed
12:30 30 2.12 2.12 2.12 63.6 2-26-S2
5:00 300
lblQ 3.01 tom 3.01 tom 3.0i
1 903 2-26-92
5 :00
300
tom 2.12 tom 2.12 tom 2.12
1 636
2-26-92
Graticule Reid Area Total Fibers/Fields
0.0G735 28/100
0.00755 4 /100
0.00755 76/100
Averaqe Blank Fibers/Fields
1/100
Fibers/Sauare mm
34. 39
1/100 3:82
it 100 95.54
Coefficient of Variation Fibers/cc 8 HR TWA
0.00
. 208
r.
0.00
.0016
0
0, 00
. 0578
0.056
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Umit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
1
Comments:
Analyzed by: - luNZa:.- Typist's Initials:
SWRf/Asfaestos 3630 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO. . INC. BARBARA POPE g ILMAN INSULAT I ON CO.. INC CAT # 1 - SKIRT ENCLOSURE 8< PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-27-92 13
1 of:
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
31 022 i'92Bl BLANK FTTa
Sample Disposition: Your samples will be returned In 30 days H we do not receive a signed letter authorizing disposal.
B2 0ZZ7UZF2 BLANK N/A
AD3 UzZfaZADo AKhA UUTbiUh tl'ltLUjUKt
EXIT
Work Being Performed
N/A
N/A
WIFE DOWN
(respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaqe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-27-92
2-27-92
2-27-92
JOE RODRIGUEZ
JOE RODRIGUEZ
JOE ROuRiGUEI
o 0 1035
0:00
0:00
7:50
0:00
0:00
12:55
0 0 305
e
oo
o.oo
lum 3.01
o.oo
lent 0.00
lent 3 01
0.00
0 2-27-92
1cm o.oo
1o 2-27-92
tom 3.01 1 '2 1 b U D 2-27-S2
0.00785
0.00785
0.00785
1/100
1/ 100
4/100
1 /100 0.00 0. 00
1/100 0.00 0.00
1/100 6. `62 0. 00
Ci 0 \G.002
000
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom
lam tom
|
Comments:
Analyzed by: Typist's Initials:
SWRf/Asbestos 3631 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO.. INC. BARBARA POPE GILMAN INSULAT!ON CO..!NC CAT # 1 - SKIRT ENCLOSURE & PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-27-92 13
2 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned in 30 days if we do not receive a signed loner authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
P4 022792P4 PEK3QNAL GUADLUPE CERRITOS 430-65-8601
P5 022792P5 PERSONAL ALEJ0S SALINAS 452-27-0114
STE6 Q22792STES SHORT TERM EXPOSURE JOE RODRIGUEZ 461-37-3474
Work Being Performed (respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaqe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Sauare mm Coefficient of Variation Fibers/cc 8 HR TWA
WIPE DOWN AND BAG OUT P.A.P.R 2-27-92 JOE RODRIGUEZ 1 U34 7:45 12:30 255 i.7l 1.71 i.7l a36.05 3-27-97 0.00785
10 0 / c 5 1 / I Lx 0
143.39 0.00 0.131 0.073
lpm 1pm 1pm 1
WIPE DOWN AND
bag out
P . A. P . R 2-27-92 JOE RODRIGUEZ 104 1 7 : 0 12:30 260 1.71 1.71 l.7l 444.6 2-27-S2 0.00785
38/100 1/100
85.35 0.00 0.074
0.04
1pm iDm .lpm
1
VISUAL INSPECTION HALF MASK
2-27-92 JOE ftUDRIGUEX A 7:45 8:15 30
2.s0 2-=0 2.50 75 2-27-92 0.00785
6/100 1 / 100 6.37 0. Ou 0 Ooo 0.004
1pm 1pm inm
l
:
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample* P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments: "A;1r
Analyzed by: Typist's Initials:
P5 JENED CF : 0 F;
SWRf/Asbestos 3632 Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
__________________ Air Sample Analysis Report__________
Client: Attention: Contractor:
Project:
SGUTHUEE7ER REFINING CO.. INC. BARBARA POPE GILMAN INSULATION CO.. INC. CAT 1 - SKIRT ENCLOSURE & PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-27-92 13
3 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sarrpie Deposition: Your Barries will be returned in 30 days II we Co rxjt rocofvo a signed iG"0r authorizing cisoosaj
Sample ID Number Laboratory Number Type of Sample Location of Sample
STE7 022792S7E7 SHORT TERM EXPOSURE GUADLUPE CEPvRITuS 4o0"65~6801
ADS 022792AD8 AREA OUTSIDE ENCLOSURE EXIT
C9 622792C9 CLEARANCES INSIDE ENCLUSUKE
Work Being Performed (respirator, if applicable)
WIPE DOWN P . A - P . ft
WIPE DOWN AND BAG OUT
N/ A
Date Sampled
2-27-92
2-27-92
0-2/-92
Sampled By
JOE RODRIGUEZ
JOE RODRIGUEZ
JGt RODRIGUEZ
Pump No.
A
1035
202
Time Started
10:55
12:55
id: oU
Time Ended
11:25
16:55
15 :10
Total Minutes Sampled
1 30
240
100
Flow Rate Start
2.50
tom 3.01
tom i = `uu
Flow Rate End
2.50
tom 3.01
tom 15-00
Averaae Flow Rate
2.50
tom 3.01
tom ib`Uu
Volume
T5
1 722.4
1 1500
Date Analyzed
2-27-92
2-27-92
2-27-92
Graticule Field Area
0.00765
0.00785
0.00735
Total Fibers/Fields
15.5/100
8/100
6/1 uO
Averaqe Blank Fibers/Fields
1/100
1/100
1 /100
Fibers/Square mm
18. 47
8 * 92
15.92
Coefficient of Variation
0.00
0.00
1 . bi
Fibers/cc
u. OS 5
\0.005
0. 003
8 HR TWA
0
0
u
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
lum
tom
tom [
Comments: ZA:ipLE * C9 & C1 WERE ADDED TOGETHER.
Analyzed by: Typist's Initials:
SWRf/Asbestos 3633 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO., INC BARBARA POPE GILMAN INSULATION CO. . INC. CAT # 1 - SKIRT ENCLOSURE & PIPES
NWE Job Number: Report Date:
Report Number: Page:
8064 2-27-92 13
4 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be relumed In 30 days jfws do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
CIO 022792C10 CLEARANCES INSIDE ENCLOSURE
PI 1 022792P11 PERSONAL GUADLUPE CERRITOS 430-65-8801
Work Being Performed (respirator, if applicable)
N/A
GLOVE BAG HALF MASK
Date Sampled
Sampled By
Pump No.
Time Started
Time Ended
Total Minutes Sampled
Flow Rate Start
Flow Rate End
Averaqe Flow Rate
Volume
Date Analyzed
Graticule Field Area
Total Fibers/Fields
Average Blank Fibers/Fields
Fibers/Sauare mm
(
Coefficient of Variation
Fibers/cc
8 HR TWA
2-27-92 JOE RODRIGUEZ
93 13:30 15:10 100 15.00 15.00 15.00 1500 2-27-92 0.00785 7.5/100
1/100
0-00 0.00 0 o
1cm lcm 1cm
1
2-27-92 JOE RODRIGUEZ A 16:00 16:30 150 2.50 2.50 2.50 375 2-27-92 0.00785
6/100 1 / i 00 6.37 0.00 <0.007 0.078
1cm 1cm icm
1
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Shortterm exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom 1pm tom
1
Comments:
Analyzed by: Typist's Initials:
SWRf/Asbestos 3634 Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO., INC. Attention: p;arbara PGF'E
Contractor: g i lman insulation CO.. INC. Project: cat tt i FiPiNG
NWE Job Number: 6064
Report Date: 2-IE-92 Report Number: i4
Page: * of:
4
Method of Analysis: NIOSH 7400 Method Specified Range: lOOcTotal Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
El G22792B1 BLANK N/A
Sample Disposition: Your ajrplmww be relumed In 30 days # we do rut receive a signed letter authorizing disposal.
B2 C22792B2 BLANK N/A
^ A D >2 ^ --A D 5
area
DUW'N WIND j.h
Bnu
GLOVE
Work Being Performed
N/A
N/A
GLuVE BAG
(respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended
2-27-92 E.GONZALES 0 0:00 0:00
/ -a*.
E.GONZALES 0 0:00 0:00
V-V 7E. GONZALES________________
PER-1023 20:00 23:00
Total Minutes Sampled Flow Rate Start Flow Rate End Average Flow Rate Volume
0
o. oo o.oo o
jBa
oo o
0
o.oo tom o.oo tom o.oo 1o
ISO
tom 2.78 tom 2.78 tom 2.78
1 500.4
tom tom tom
1
Date Analyzed Graticule Field Area
2-27-92 0.00765
2-27-92 0.00755
2-27-92 0.00755
Total Fibers/Fields Averaae Blank Fibers/Fields
1/100 1/100
1/100 1/100
7 /100
moo
Fibers/Sauare mm
0.00
0.00
7.64
Coefficient of Variation Fibers/cc
0. 00 0
0.00 0
0.00
00gg
8 HR TWA
0
0
0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Ana lyzed by - mi ALES
Typist's Initials: J
^
SWRf/Asbestos 3635 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO.. INC. Attention: Barbara fore Contractor: q i lman i nsulaT i on cu .. i nc.
Project: cat tt i PiPiNG
NWE Job Number: Report Date: i-17-92
Report Number: l4
Page: 2 of; 4
Method of Analysis: NIOSH 7400 Method Specified Range: lOOcTotal Fibers<1300 f/mm2
Sample Disposition: Your Bampleswlll be returned In 30 days If we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2?4 022~922P4 PERSONAL ERA3M0 MARTINEZ 455-25-3425
2S7EE 0227322STE5 SHORT TERM EXPOSURE ERA3HQ HART INEZ 45O " D -- j
2F6 G227322PS PERSONAL JOSE MESA 450-61-5590
Work Being Performed (respirator, if applicable)
GLOVE BAG HALF MASK
GLOVE BAG
GLOVE BAG Half mask
Date Sampled
2-27-92
-27-92
2-27-92
Sampled By Pump No. Time Started
E. GONZALES PER-D 20:00
E.GONZALES PER-D 0:00
E.GONZALES FER-B 2\J !
Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Average Flow Rate Volume Date Analyzed
23:00 1 iso
2.51 2.51 2.51 451.6 2-27-92
0:30 30 Iran 2.51 tom 2.51 lum 2.51 1 75.3 2-27-92
22: 30 160 tom 2.51 tom 2.5i tom 2.51 I 451.6 2-27-92
Graticule Field Area Total Fibers/Fields
0.00785 56/100
0.00785 12/100
0.00735 21/100
Averaqe Blank Fibers/Fields Fibers/Sauare mm Coefficient of Variation
1/100 70. 06 0.00
1/100 14. 01 0.00
1/100 25.47 0.00
Fibers/cc 8 HR TWA
. 059 0.022
.0716 0
. 0217 0. 008
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
I
Comments:
Analyzed by: = Gonzales Typist's Initials:
SWRf/Asbestos 3636 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO. . INC. Attention: Barbara pope
Contractor: g [ L.MAN INSULATION CO.,INC. Project: cat # l PIPING
NWE Job Number: 8c6l+
Report Date: 2-37-92 Report Number:
Page: 3 of:
4
Method of Analysis: NIOSH 7400 Method Specified Range.' 100<Total Fibers<1300 f/mm2
Sarnote Deposition: Your samples ill be returned In 30 days If we do not ranelvo a signed tetter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
ilb i h / ,'9zLbTE7
SHORT TERM EXPOSURE J G3E MESA 450-81-3590
2 ADS 0227922AD8 AREA DOWN WIND uF GLOVE BAG
2F9 0227922P9__________________ PERSONAL J i_J --! C M A 450-81-5592
Work Being Performed (respirator, if applicable)
GLOVE BAG
half mask
GLOVE BAG
GLOVE BAG
half mask
Date Sampled
2-27*92
2"27-92
-- 4 i * ii
Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start
E.GONZALES PER-B 0 :00 0:30 1 30 2.51
E.GONZALES
E.GGNaaLES
PER-1033
FEP:-E
0:00________________________ 0:30_________________________
5:00
5 :30
300_________________________ 300
lum 2.78
lum 2.51
lum
Flow Rate End Averaqe Flow Rate
2.51 2.51
lum 2.78 lum 2.78
tom 2.51
bin 2.51
tom tom
Volume Date Analyzed
75.3 2-27-92
1 854 2-27-92
1 755 a- t7-92
1
Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields
0.00735 8/ 100 1/100
0.00785 4/100 1/100
0.00785 15/100 1/100
Fibers/Square mm
8.91
3.82
17.83
Coefficient of Variation
0.00
0.00
0.00
Fibers/cc
.0455
. 0017
. 009
8 HR TWA
0
0
0.0056
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: `i u N Z A L E 5 Typist's Initials: JLR
SWRflAsbestos 3637 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO. . iNC. Attention: barsara FuF'E
Contractor: gilman insulation cg.,inc. Project: cat # l PIPING
NWE Job Number: 5^5*
Report Date: 1-27-22 Report Number: l4
Page: a of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be relumed In 30 days# we do not tecelve a signed toner authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2P10 0227922P10 FEREGNAL ERASMG MARTINEZ 455-25-8425
Work Being Performed (respirator, if applicable)
GLOVE BAG HALF MASH
Date Sampled Sampled By Pump No. Time Started
2"j?"92 E.GONZALES FER-D 0:30
Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area
5:30 300 2.51 2.51 2.51 753 2-27-92 0.0G765
Iran Iran Iran
1
Iran bra Iran
1
Total Fibers/Fields
23/100
Averaae Blank Fibers/Fields
1/100
Fibers/Square mm
28.02
Coefficient of Variation
0.00
Fibers/cc 8 HR TWA
. 0143 0.G069
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure-ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
bra bra Iran
1
Comments:
Analyzed by: GONZALES Typist's Initials: J'LR
SWRf/Asbestos 3638 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO.,INC. BARBARA POPE GILMAN INSULATION CO..INC CAT # 1 - STRUCTURE & PIPE RACKS
NWE Job Number: Report Date:
Report Number: Page:
8064 2-28-92 15
1 of: 3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Samole Disposlllon: Your samples will be relumed In 30 days H we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
Work Being Performed (respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
Bl 0228S2B1 BLANK N/A
E2 022892B2 BLANK N/A
P3 022892P3 personas: ALEJ0S SALINAS 452-27-0114
STRUCTURE
N/A N/A GLOVE BAG ON 7TH DECK OF STRUCTURE
HALF MASK
2-23-92 JOE RODRIGUEZ 0 0:00 0:00
2-28-92 JOE RODRIGUEZ 0 0:00 0:00
2-28-92 JOE rdo'riguEz 1034 7:50 11:20
0 0 210
BP ep
oo plo oo
L
o. oo
tom
2,41
tom
o. oo
luxn
2,41
tom
0.00
o 2-28-92
tom 0. oo
10 2-28-92
tom 2 41 1 506.1
2-28-92
tom !
0.00785 1/100
0.00785 1.5/100
0.00785 12.5/1O0
1.25/100
1.25/100
1.25/100
0.00 0.00 0 0
0. 00 0.00 o
0
14.33 U7UT) O .Oil O. U1J
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, 8-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: J0E RuL'.t I gC=.z Typist's Initials:
SWRf/Asbestos 3639 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SQUTHWE STERN REFINING CO. . INC.
BARBARA POPE GILMAN INSULATION CO.,INC CAT # 1 - STRUCTURE k PIPE RACKS
NWE Job Number: Report Date:
Report Number: Page:
8064 2-28-92 15
2 of: 3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sampls Disposition: Your 6arrplsswillberetum9d In 30 days# we do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
Work Being Performed (respirator, if applicable)
?4 022832P4 PERSONAL JESUS MATA SR. 459-43-8543 #2P2P1 GLOVE BAG HALF MASK
AD 5 022892AD5 AREA DOWN WIND FROM GLOVE BAG BY STRUCTURE GLOVE BAG
STE6 022892STE6 SHORT TERM EXFU5UKE ALEJOS SALINAS 452-27-0114 TURBINS GLOVE BAG HALF MASK
Date Sampled
2-28-92
2-28-92
2-28*92
Sampled By Pump No.
JOE RODRIGUEZ B
JOE RODRIGUEZ 1041
JOE RuL'h.iGUEZ 1034
Time Started
8:10
7:50
12:50
Time Ended
11:20
17:00
13:20
Total Minutes Sampled
190
550
30
Flow Rate Start
.2.41
1cm 3.05
lorn 2-41
Flow Rate End
2.41
1pm 3.05
lpm 2-41
Averaqe Flow Rate
2.41
lpm 3.05
1pm 2 4 i
Volume
457.S
1 1677.5
1 /2.3
Date Analyzed
1 2-28-92
2-28-92
2-28-92
Graticule Field Area
0.00785
0.00785
0.00785
Total Fibers/Fields
33/' 100
8 /100
8.5/100
Averaae Blank Fibers/Fields
1.25/100
1.25/100
1.25/100
Fibers/Sauare mm
40.45
S. 60
9.24
Coefficient of Variation
0.00
0.00
0. 00
Fibers/cc
0.034
<0.002
<0.u4y
8 HR TWA
0.021
0
0.01b
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
1pm 1pm 1pm
!
Comments:
Analyzed by: Typist's Initials:
3640 S\Nmi&sbestos Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO..INC. BARBARA POPE GILMAN INSULATION CO., INC. CAT tt 1 - STRUCTURE l. PIPE RACKS
NWE Job Number: Report Date:
Report Number: Page:
8064 2-28-92 15
3 of: 3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned in 30 days if we do not receive a signed tetter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
P7 0228S2F7 PERSONAL JESUS MATA SR. 459-^3-8543
P3 022S&2P8 PERSONAL ALEJOS SALINAS 452-27-0114
Work Being Performed (respirator, if applicable)
GLOVE BAG BY SERVICE CONDENSER HALF MASK
GLOVE BAG bV WASTE HEATER BOILER HALF MASK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-28-92
2-2S-92
JOE RGDRIGUE2
JOE RODRIGUEZ
D 1034
12:50
13:20
18:30
17:10
310 190
2.41
tom 2.41
tom
2.41 2.4i
tom 2.41
1cm 2.41
tom
lcm
747. 1
1 45/. 9
1
2-28-92
2-28-92
0.00785
0.007S5
28/100
13.5/100
1.25/100
1.25/100
34.08
15.61
0.00
0. 00
0.01b
0.013
0.021
0.013
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom
tom
tom 1
Comments:
Analyzed by: J ijE ':LlL'r; ' 'j!Typist's Initials:
WE TURNED OF
E 30 MINI
SWRf/Asbestos 3641
Reviewed and Approved by:
Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO.. INC. Attention. oARtAFiA pofe Contractor: oilman insulation co. . inc.
Project: cat # l PIPING
NWE Job Number: ,3^
Report Date: c-Lr-i L Report Number: ^
Page: : of:
,
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned in 30 days If we do no! receive a signad letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
B1 022S92B1 BLANK N/A
B1 0 ;2592B2
BLANK____________________ N/A
AREA
L*DWh w> i Uu
GLOVE BAG
Jr
Work Being Performed
N/A
N/A
GLOVE. bag
(respirator, if applicable)
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Square mm Coefficient of Variation
2-28-92 E.GONZALES
0 OiOO
0:00
0
o. oo o.oo o.oo o
2-28-92 0.00785
1/100 i /100
0.00
0.00
2-28-92 E.GONZALES
0 0:00
0:00
0
bin o.oo bra o. oo bra o.oo 1o
2-28-92 0.007 35
1 /100 i/100
0.00
0.00
r . Osjl-iZA'i.t- A P F E - 10 2 8 20:00 25:00 150 bm 2.78 bm 2.76 bm 2.78 1 500.a
L " b " w xi 0* 00/35
6/100 1 /100 6. Si 0. 00
Fibers/ce
0
0
. 0066
8 HR TWA
0
0
0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure-ceiling, LOQ-Limit of Quantitation-The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
bm bm bm
1
Comments:
Analyzed by: F- GONEales Typist's Initials: JLF:
SWRf/Asbestos 3642 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO.. INC. Attention: Barbara pope Contractor: g i lman 'insulation CO.. INC.
Project: cat ft i PIPING
NWE Job Number: 5064 Report Date: 2-20-9;
Report Number: ^
Page: 2 of: a
Method of Analysis: NIOSH 7400 Method Specified Range: lOOcTotal Fibers<1300 f/mm2
Sample Disposition: Your aamplee will be returned In 30 days # wd do not receive a signed letter authoring disposal.
Sample ID Number Laboratory Number Tvoe of Sample Location of Sample
2P4 0228922P4 PERSONAL RAY WITHERSPOON 466-69-9535
2STE5 C226922STE SHORT TERM EXFuSURE HAY W1THnRSPOON 466-6a-9oAo
2P6
PERSONAL MARTIN MARTINEZ 463-15-2333
Work Being Performed (respirator, if applicable)
GLOVE BAG HALF MASK
GLu'VE BAG HALF MASK
GLOVE BAG HALF' MASK
Date Sampled
2-2S-92
2-28-92
2-26-92
Sampled By
E.GONZALES
E.GONZALES
E.GONZALES
Pump No.
PER-A
PER-A
PER-D
Time Started
20:00
1:00
21:00
Time Ended
23:00
1:30
23:00
Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed
1 180 2.51 2.5i 2.51 451.6 2-28-92
30 120
tom 2.51
tom 2.51
torn 2.51
tom 2.5i
tom 2.51_________________ Im 2.51
1 75.3 2-26-92
1 301.2 - 7 A - 0 -
Graticule Field Area Total Fibers/Fields
0.00765 29/100
0.00765 11/100
0.00765 17/100
Averaae Blank Fibers/Fields
1/100
1/100
1/100
Fibers/Square mm
35. 66
12.73
20.38
Coefficient of Variation Fibers/cc 8 HR TWA
0.00 . 03 0.011
0.00 . 065 0
0.00 035 0.0065
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personai sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation*The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
1
Comments:
Analyzed by: Gonzales Typist's Initials: JLF-
SWRf/Asbestos 3643
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
_______ Air Sample Analysis Report__________
Client: southwestern refining co. . inc. Attention: Barbara pope
Contractor: gilhan INSULATION Cu.. INC. Project: cat # i piping
NWE Job Number: 30e* Report Date. 2-23-92
Report Number: i6 Pa9e: 3 of;
4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your aample* will be returned In 30 days# we do not receive a signed toner authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2ETE7 02239225TE7 SHORT TERM EXPOSURE MARTIN MARTINEZ 46c-15-9335
2 A Do C 2 2 6 9 2 2 A L! S
JLEi_______________________ C226922P9
AREA________________________ PERSONAL___________________
DOWN U1ND OF
Ray w1THERSPGQN
GLOVE BAG
466-69-9E-iS
Work Being Performed (respirator, if applicable)
GLOVE EAG HALF MASK
GL0VE EAG
'jLllv't fiAls
half mask
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume
2-28-92 E.GONZALES PER-D 1:00 1:30 30 2.51 2.51 2.51 75.3
2-28-92
E.GONZALES_______________ E. GONZALES
PER-1038
PER-A
1:00
1: ov
5:00
5: j0
240 240
tom 2.78
tom 2.51
tom 2.78
tom 2.51
tom 2.78
tom 2.51
1 667.2
1 602.4
Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Sauare mm
2-28-92 0.00765
7/100 1/ 100 7.64
2-28-92 0.00785
9/100 1/100 10. 19
2-28-92 0.00785
44/100 1/100
54 * 77
Coefficient of Variation Fibers/cc 8 HR TWA
0. 00 . 039
0
0.00 . 0047
0
0.00 1 020
0.ui78
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation-The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom
I
Comments:
Analyzed by: Typist's Initials: JLj*
SWRf/Asbestos 3644 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO.. INC. Attention: Barbara POPE Contractor: g;lman i'nsulation co.. inc.
Project: cat a l FIFING
NWE Job Number: ^64
Report Date: 1-2S-32 Report Number: ^
Page: 4 of: 4
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples wlllbe returned In 30 days if W8 do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
2F10 0223922P10 PERSONAL MARTIN MARTiNEZ 463-15-3353
Work Being Performed (respirator, if applicable)
GLOVE SAG HALF MASK
Date Sampled Sampled Bv Pump No.
E.GuNZALES PER-D
Time Started
1:30
Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed
5:30 240 2.51 2.51 2.5i 602.4 2-28-92
-
bra Inn bra
1
bm bra bra
1
Graticule Field Area Total Fibers/Fields
0.00765 27/100
Average Blank Fibers/Fields
1/100
Fibers/Sauare mm
33. 12
Coefficient of Variation
0.00
Fibers/cc
.0169
8 HR TWA
0.0105
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
bra bm bra
1
Comments:
Analyzed by: E ggnzal=.3 Typist's Initials: -'i-R
SWRflAsbestos 3645
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTH'JESTERM REFINING CO.. INC. Barbara pope GILMAN INSULATION CO.. INC CAT ft 1 - PIPE RACKS
NWE Job Number: Report Date:
Report Number: Page:
3064
2-29-92
17
1 Of:
3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
B1 C22992B1 BLANK N/A
Work Being Performed (respirator, if applicable)
N/A
Sample Disposition: Your sample* will be returned In 30 days ilwado not receive a signed letter authorizing disposal.
B2 022992B2 BLANK N/A
N/A
P3 022yyzP3 PERSONAL USCAK GARCIA 449-29-0019 BY SERVICE C0NDEN. gLove bag HALF MASK
Date Sampled
2-23-S2
2-29-92
2-29-92
Sampled By
JOE R0D RIGU E Z
JOE ftUD ft IG U E Z
Joe kolriguez
Pump No.
0
0
1041
Time Started Time Ended
0:00 0:00
0:00
7:50 i i: 40
Total Minutes Sampled
I0
0
2d 0
Flow Rate Start
0.00
tom 0.00
icm ~ 41
tom
Flow Rate End
o. oo
tom 0.00
lpm 1--41
tom
Averaqe Flow Rate
0.00
tom 0.00
1pm ___ ;:41,__________________ tom
Volume
0 l0
1 Ss4.d
j
Date Analyzed
2-29-92
2-29-92
2-29-92
Graticule Field Area
0.00735
0.00785
0.00785
Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
0/100 1 /100 0. 00 0. 0U o 0
2/100 1/100 0.00 OTTST 0
1 1.5/100 1/iOU
21.02 07TR3 O.OIb 0TUT5
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: Typist's Initials:
SWRf/Asbestos 3646 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO.. INC. BARBARA POPE GILMAN iNSULATIGN CO.. INC. CAT # 1 - PIPE RACKS
NWE Job Number: Report Date:
Report Number: Page:
8064 2-29-92 17
2 of: 3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sarrpia Disposition: Your samples wiil be returned in 30 days if wa do not receive a signed letter authorizing disposal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
Work Being Performed (respirator, if applicable)
P4 02292P4 PERSONAL GUADLUPE CERRITOS 430-65-8801
GLOVE BAG HALF MASK
AD5 022992ADS AREA DOWN WIND FROM SOUTHWEST OF PIPE RACK GLOVE BAG
STE6 02 SHUKi TERM fcXPUbUKE USCAK GAkolA 449-29-0019
G L U V E BAG HALF MASK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-29-92
2-29-92
2 ~ 2!d ~ y 2
JOE RODRIGUEZ
J0E RODRIGUEZ
JOE RODRIGUEZ
1034
1033
1041
7:50
8:00
12:50
11 :40
11:40
13:20
230
220
30
2.41 2.41 2.41 554.3
tom 3.05 iDm 3.05 1pm 3.05
1 671
ipm 2,41 ipm 2,41
ipm 2,41 l /2.3
2-29-92
2-29-92
Z-29-92
0.00785
0.0G785
0.00785
18.5/100
10.5/100
8/ 100
1/100
1/100
l/l'OU
22.29
12.10
0. 00
0.00
U7UQ
0.015
<0.007
<.0.04 {
0. 02
0
U . 01 b
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Ipm
1pm
1pm i
Comments:
Analyzed by: Jlj- ---`jIt. ft.-. Typist's Initials: J
SWRf/Asbestos 3647
Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: Attention: Contractor:
Project:
SOUTHWESTERN REFINING CO.. INC, BARBARA POPE GILMAN INSULATION CO., INC. CAT # 1 - PIPE RACKS
NWE Job Number: Report Date:
Report Number: Page:
908 A 2-29-92 17
3 of: 3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Disposition: Your samples will be returned In 30 days #wg do not receive a signed lattar aulhorizing disposal.
Sample ID Number Laboratory Number
Type of Sample Location of Sample
AD7 022992AD7 AREA DOWN WIND FROM SOUTHWEST OF PIPE
P8 02299288 PERSONAL GUADLUPE CEKKiruS 430-65-8801
P9 0Z292Fy PtRSUNAL OSC'KE.. GAHC1A 449-29-0019
Work Being Performed (respirator, if applicable)
RACK GLOVE BAG
GLOVE BAG HALF MASK
Glove bag HALF MASK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaoe Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaqe Blank Fibers/Fields Fibers/Square mm Coefficient of Variation Fibers/cc 8 HR TWA
2-29-92
2-2^2
2-29-92
JOE RODRIGUEZ 1033
JOE HCJDRI GUtZ 1034
JOE K U D K 1 G U E 4
Torn
12:50
12:50
13:20
17:10
17: 10
17:10
260
260
230
3.05 3.05 3.05 793
1pm tom 2.41 1pm 2.41
1 626.6
to to
1pm to
1pm " *41
to
j 554.3j
2-29-92
2-29-92
2-29-92
0.00785 8/100
0.00785 31/100
0.00/85
1 'll loo
1/100 8.92 (TTuO <0.004
1/1'00 3b. 22 0. 00 0.023
1/luU
nmn
0.00
O'TOT
0
0 * LL
0.015
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: JOE RODRIGUEZ Typist's Initials: J . R.
SWRf/Asbestos 3648 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CU..INC. Attention: BARBARA POPE
Contractor: G 1LMAN INSULATION C0..INC. Project: cat ft l PIPING
NWE Job Number: 306*+ Report Date: o-Od-jc
Report Number: ^ Page: 1 of:
3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Totat Fibers<1300 f/mm2
Sample Disposition: Your samples wai be relumad In 30 days If we do no! receive a signed letter authorizing disoosal.
Sample ID Number Laboratory Number Type of Sample Location of Sample
B1 022992B1 BLANK N/A
E2 022292B2 BLANK N/A
lr.E-5 02292AD3 AREA DOWN WIND OF GLOVE BAG
Work Being Performed
N/A
N/A
GLOVE BAG
(respirator, if applicable)
Date Sampled
2-29-92
2-25-92
Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume Date Analyzed Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Sauare mm Coefficient of Variation
E.GONZALES 0 0:00 0:00 0 o. oo o.oo o.oo o 2-29-92 0.00785
1/100 1/100 0.00 0.00
E.GONZALES
E.GONZALES
0 PER-1035
0:00________________________ 22:30_______________________
0:00
23:30
0 60
tom 0.00
tom 2.78
tom
tom o. oo
tom 2.78
tom
tom o. oo 1o
9-0Q-0 "
0.00785
tom 2.78 1 165.8
2-29-92 0.00785
tom 1
1/100
5/ 100
1/100
1/100
0.00
5.09
0.00
0. 00
Fibers/cc
0
0
. 0117
8 HR TWA
0
0
0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation-The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: gonzales Typist's Initials: jLR
___ ^
S\NRf IAsbestos 3649
Reviewed and Approved by : Q.C. Supervisor
Northwest Envirocon Inc.
. 7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client: SOUTHWESTERN REFINING CO. . INC. Attention: Barbara ,?ope
Contractor: g j lman INSULATION Cu.. INC. Project: cat # l piping
NWE Job Number: 606i,
Report Date: 2-20- 3; Report Number: L%
Page: 2 of:
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample ID Number Laboratory Number Type of Sample Location of Sample
G229322P4 PERSONAL JOSE MEZA
4 Zj U " 6 1 " O Z 9 `J
Sampla Dapoaltlon: Your amples will ba relumed In 30 days if we do not receive a 6lgn9d tetter authorizing disposal.
2STE5 C2293223TES SHORT TERM EXPOSURE JOSE MEZA 450-31-5590
2P5 22292F6_____________________ PERSONAL JOSE MEIA
50 - 1 "w'Oi'v
Work Being Performed (respirator, if applicable)
GlOve. bag HALF MASK
GLOVE LAG HALF MASK
'j U 0 V . $ A 'o
HALF MASK
Date Sampled Sampled By Pump No. Time Started Time Ended Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate
2-29-92 E.GONZALES PER-B 20:30 23:30 180 2.51 2.51 2.5i
2-29-92
2-22-92
E. G0Nz.Al.ES
E.GONzaLES
PER-B
PER-B
0:30________________________ 1:00_________________________
1:00
5:00
30
Iran 2.51
240
tom 2.51
tom
tom 2.51
tom 2.51
tom
tom 2.5i
tom 2.5i
tom
Volume Date Analyzed
451.6 2-29-32
1 75.3 2-29-92
1 602.4
"j _ O Cl - Ci *>
1
Graticule Field Area Total Fibers/Fields Averaae Blank Fibers/Fields Fibers/Sauare mm Coefficient of Variation
0.0G765
18/100
1/100'
21.65
0.00
0.00765
6 /100 1/100
6.36
0.00
0.00755
12/100 1/100
14. 01
0.00
Fibers/cc 8 HR TWA
.0164
0.012
* 0325 0
. 007
0.012
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure-ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
Comments:
Analyzed by: E. c-onzales Typist's Initials:
SWRf/Asbestos 3650 Reviewed and Approved by: Q.C. Supervisor
Northwest Envirocon Inc.
7410 Delaware Lane Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852
Air Sample Analysis Report
Client; SOUTHWESTERN REFINING CO. , INC. Attention: Barbara pope
Contractor: g i lhan Insulation cg..inc. Project: cat # l PIPING
NWE Job Number: 5354
Report Date: 2-29-92 Report Number: ^
Page: 3 of:
3
Method of Analysis: NIOSH 7400 Method Specified Range: 100<Total Fibers<1300 f/mm2
Sample Dlspoeltkm: Your samples wlllbe returned In 30 dayBlIws do not recslve a signed letter authorizing disposal.
Sample'ID Number Laboratory Number Type of Sample Location of Sample
2AD10 0229922AD10 AREA DOWN WIND OF GLOVE BAG
Work Being Performed (respirator, if applicable)
GLOVE BAG
Date Sampled
-* s *** *-i y
Sampled Bv
E. GONZALES
Pump No. Time Started
PER-1035
0:00
Time Ended
5:00
Total Minutes Sampled Flow Rate Start Flow Rate End Averaae Flow Rate Volume
300 2.78 2.78 2.78 834
lbm tom
torn 1
tom lorn tom
1
Date Analyzed
2-29-92
Graticule Reid Area
0.00735
Total Fibers/Fields
7/ 100
Averaae Blank Fibers/Fields
1/100
Fibers/Square mm Coefficient of Variation
7.64 0. 00
Fibers/cc 8 HR TWA
. 0029 0
Abbreviations: AP-Area sample prior to abatement, AD-Area sample during abatement, C-Clearance sample, AC-Aggressive
clearance sample, P-Personal sample from breathing zone, B-Blank sample, NAE-Negative air exhaust, CR-Clean room, STE-Short term exposure=ceiling, LOQ-Limit of Quantitation=The limit below which the sample cannot be accurately calculated
May Represent Exposure to:
tom tom tom 1
Comments:
Analyzed by: R.- GONZALcS Typist's initials:
SWRf/Asbestos 3651
Reviewed and Approved by: Q.C. Supervisor
SWRf/Asbestos 3652
Northwest Envirocon. Inc. 7410 Delaware LaneVancouver, Washington 98664 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
Air Monitoring Pump Calibration Record
Client:So^-fk uses +er/i
Attention: B*rb*r# Pope.
Project: Ca + */ Location. $ f a! rks Ay Co
Date Calibrated by
2- /r -12 (joe. do
y J,
'
Co^Zac.
Pump Type .M 5/2
... 1
NWE Order Number: QO&H
Date Calibrated:
/S-
Flow Rate (liters per minute) Pump ID No. start stop Illlllll 111!
/S[ ^3.0$ Per " ft
^5.08 Per - C.
Per -
Per ~ Per "
Per --
----- ------------ ....- ------ -------
----- -
2- -92
.._ -- - -- - -
------------ -----
----------- ---
UP HP -
tHv-
SWRf/Asbestos 3653
Northwest Envirocon, Inc. 7410 Delaware LaneVancouver, Washington 98664 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
Air Monitoring Pump Calibration Records
Client: So<sihuse.s+ern PePininj Co.,!*'.-
Attention: Q(\hb*ra Pope.
Project: Cr>S * /
Location. S
rt*s*t fL*c./osvrt.
NWE Order Number: Date Calibrated: <2 - ! & - ??
Date
Calibrated by
Pump Type
Flow Rate (liters per minute)
Pump ID No.
S- It - IS 17
start
stop
A M S 0__________ 7-------
Cj
e$ X?. OS Per - 6
.os Per- c ppf Per ~ P ITJ*^ Per - A
j
Per - O
1 Per -- / 0S3 * P^l8
for - / o v/ ^
4s _______ ^S
\Lr
Per - /o 35 ipti
Per * H
( >
-
-- ... -
1 1
/!--e-- -a----r---o----------HP -
.-- ---- --- - ------ - -- HU r Hv-
SWRf/Asbestos 3654
Northwest tnvirocon. Inc. 7410 Delaware LaneVancouver, Washington 98664 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
Air Monitoring Pump Calibration Record
Client: ik uses ter/} Pe/inlrj C0.}I<\c-
Attention: Q^rbnm Pope.
Project: Cp + # /
Location:
Cot* t\^ lo<s
NWE Order Number: ftO&H Date Calibrated: '/9' - 9J
Date
Calibrated by
Pump Type
Flow Rate (liters per minute)
Pump ID No.
start
stop
Vi^
a-
n -is
/T9ft__RoJA'\!/C Z t7
MS/?__________
^2. a! Per - A
' .--V v\
-sj\*0v > \
7 /-- -^3. oS
^1.0$
^2.0 /
Per - /oJJ
is*3^ Per - 0
1*1!^ t^y3.o8 Per - C H-OO^
2.01 Per" O
Per-- / Oc// L
\U _______ Vy
_______ v y
Per - /(>3S
/j3^ SJ^Tdcdt'
'>^2.0/
Per- fi
l
-- --
-- ........... --
----
.. .. _ ~~
- - -
i
i
Ki
i 1
1 6/ ________________
Iy vs
. . ---
d)//e a r o .... ------
^Ts.o nyK'
SWRf/Asbestos 3655
ti'" P)o3l S Mv - 93 $ Hi/ ^__________
Northwest Envirocon, Inc. 7410 Delaware Lane*Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
Air Monitoring Pump Calibration_Record
Client: So* M c^cs +erst Ra-fininj Co.}IacAttention: Q a r h Ar a Pope
Project: Crude Uri-t Location: 7-j > e0;/a,s { plf,0
NWE Order Number: *3 >9 Date Calibrated: ^2 -
** 92
Date
Calibrated by
Pump Type
Flow Rate (liters per minute)
Pump ID No.
start
stop msmrnmm
1- 2 o - 12
J/or KoJa;7<jc}
M S 4_________ SsS.ol
Per - ti
IPf.Od Per - /0J3
JsS.0# Per - S0 y/
SsS-Ol Per- UJS-
/ftps' ^1.01 Per- /?
______ Vj /
O'
Per-- So JS~ Per - ti
-- -------------2- -92
;-.7- -- -------------
n // e a r o r
.......-- --- -.............. -------
NIP tit/ftv-
SWRf/Asbestos 3656
Northwest Envirocon, Inc. 7410 Delaware Lane*Vancouver, Washington 986o4 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
Air Monitoring Pump Calibration Record
Client\So'''(ku/cs ter/i Attention: BArb^rtt Pops.
Project: Cr* He i/n : -f Location: j3 j a0;Un 1
Co.}lc-
tAcfe
NWE Order Number: Date Calibrated: L -<P/ --
Date
Calibrated by
Pump Type
oL- 21
-
12
d) e. (7
el.Kt' V ^ 7. Ms a
V/
\/s
\
\|/
Flow Rate (liters per minute)
start
stop
Pump ID No.
Per ~ foil
2>5.,of Per - ft
Per - d
PPPi
IXf.ol Per - 0
Pf.oJ
Per " fo c/f
^2.HI J^2Mf Per-- A 0OO^ P^l.of Per " Pi
^2. Qt Pr r ~~ /O 3S~ 1
----
-----------------
l
' ________________
rf /! e a r o
J ----- -- -- .. ------ ----- --------
//-
MU HU -
SWRf/Asbestos 3657
Northwest Envirocon. Inc. 7410 Delaware LaneVancouver, Washington 98664 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
Air Monitoring Pump Calibration Record
Client :$o<s1h^c$terrt Pe/ininy Co^IacAttention: Q*rbnm Pope.
Project: Crude CAnlf Location: jj ^ <3 oiler's j p;per*c,p
NWE Order Number: Date Calibrated: -
Date
Calibrated by
Pump Type
2- 21 ~ 12 jJoe-
7
2. A/l 5 ft.
7
\ / V/
\l/
Flow Rate (liters per minute)
start
stop
Pump ID No. *
Per -'/033~
^3.0g Per - /03J
9(3*^
Per ~ 0 .
Pep - 0
12 ^2-^' 2^3.09 Per "
Pe*-- {02 3
lJ^2H{{ 1%*^1
2^9.01
for ' Per-
P 6
Per - A
----
2' -n ________________
A)//e q r o
Nl/ ' Hi/ Hi/-
SWRf/Asbestos 3658
Northwest Envirocon. Inc. 7410 Delaware LaneVancouver, Washington 98664 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
Air Monitoring Pump Calibration Record
Client: So*'-th uses te^/i PePinlfij Co.
Attention:
Pope.
Project:
/
Location: /-P-
NWE Order Number: Date Calibrated:
Date
Calibrated by
Pump Type
Flow Rate (liters per minute)
Pump ID No.
start
a- 2H- ia yJ/o-e 1
v
c
Ms#________
Ik
^7.09
1 C ________________
^1.0.?
/ -V ______ii
stop
Per - 0 Per - Jo lb~ Per - P) Pes Per ~
Per-
- .......----------- -----------
-------- -- --- -- ------------ ------ --
-n _____________
$//e a r o j
-
PIP JJU /si/-
SWRf/Asbestos 3659
Northwest Envirocon, Inc. 7410 Delaware Lane*Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
_ Air Monitoring Pump Calibration Record
Client:
uses terp Re-Pin!aj Co.tInc.-
Attention: B*rb*r* Pape. Project: C--f * I
Location: ^//V ucLst,^ { ??**
NWE Order Number: ftO&H Date Calibrated: ^
Date
Calibrated by
a- 3t -13 '
OJf
J
Pump Type M 5A
Flow Rate (liters per minute)
start
stop
Pump ID No.
Per - (01P' iJPtv Per - toy V
/??/* -/$-?{ -
{IJ2--" ^;.v/
Sa'} ^c ii
/fe/' /?
/%/*"
Pe*-- io-iy
ft,- /e?J?
/ r0
ft, -A '
/
/ J. t,? <7- Per - /p ? jT /
---
(
\
r'
$/!e a r o J
til/ -
^__________ SWRf/Asbestos 3660
Northwest Envirocon, Inc. 7410 Delaware Lane*Vancouver, Washington 98664 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
___ Air Monitoring Pump Calibration Record
Client: So^-fk uses +er/i
Attention: 8*rb*r* Pope.
Project: y ^ /
Location: J/cP t
/o > u ,<> j
Cosine. jr
NWE Order Number: Date Calibrated: y - jl? - 9-?
Date
Calibrated by
X- >7-?a (inf \/
i"
1
11
Vr __ J/
Pump Type
Flow Rate (liters per minute)
Pump ID No.
MS/7__________
start
stop
!)Ha\ Per - /O 3$
ibPhi\ Per - /O 3 Y
`PHf
Per -10 Hi Per ~ ft Per " ft
Per-- /o 7 >
'1{ Ppf - ft
fer -
----
Ae J- 77 -92
*Js
'
i
y
|
._
rZ//a a r o 7 \is
_ .. p
--
UP -13 ft!/ttiLz.__________
SWRf/Asbestos 3661
Northwest Envirocon, Inc. 7410 Delaware LaneVancouver, Washington 986b4 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
Air Monitoring Pump Calibration Record
Client: So^ uses fern RuPtninj Cosine..
Attention: Srirh/^re PopsProject: C&t ^ (
Location: f+ruc ^ / c AV - c tjr -
NWE Order Number: ftO&H
Date Calibrated:
-- 7a?
Date
Calibrated by
a- A? - fa I '7
1
1
\J/ V/
Pump Type
Flow Rate (liters per minute)
start
stop
Pump ID No.
MS/?__________
Per - l01L
v/ Per - /o5lf
uJ^xC(
Per - - 6
Per * / 7 V
vi/
s^i^n >^L// Per" $
^7T<y/ .
Per- iolW
a- -92
---- --- -
rf /f--e a r--o------
PI/ '
HI/ -
______
SWRf/Asbestos 3662
Northwest Envirocon. Inc. 7410 Delaware LaneVancouver, Washington 98664 (206) 699-4015 (800) 395-0852 Fax: (206) 699-5223
Air Monitoring Pump Calibration Record
Client: _fcW4 uses +er/i fte-fininj Co.}1ac.
Attention: Q*rb*rA Pape.
Project: fp /
Location:
^ f^c J
NWE Order Number: Date Calibrated: <2-3-? - 9c?
Date
Calibrated by
2- l'i - n 1
L
>
1
1 1___
1
11
\l/ V
,
Pump Type
Flow Rate (liters per minute)
Pump ID No.
start
stop
//L/pX
MSA__________
w/ ixfv/ Per - A' V/
* JJKl if ^x X/ Afe/* - //' : V
F??/- - ' cr ?,T
XTfl S^X
J r X1//
/%/- /t'V/
j /J
OO A??/' - / D 3$
X?I L.ft'
X' Per-- /O 3/
'X\y c>`"
/A, -/OV/
2- -92
----
--
rr
//e a J
r
o
^x" /X t-fy W^__________
SWRf/Asbestos 3663
SWRf/Asbestos 3664
o
4fc tor
Q. CD
cc
0g3j oQ..
o CO
Hill!
in
CD CD
co
CO
o
\ -CQ/9
oE
o oo
C/3 0
Tfco CO
00 03
I
CD
O3
f--\
8?
iO 03
03
03 CO
C
CO _J
co o
CM
CD
cn
5
JS
CD
Q
O
ah-
O
Z
c
CD m
(~n
sV
>- \a
v,
Qq
o 03
%
'o _Q
*--
Q_
O
~3
a
o
03
c o O
Sunday M onday Tuesday W ednesday T h u rs d a y F rid a y S aturday T o ta ls
o O)
2
E
<D
5
03 CL
03 03
CL
E
1
CO
CO
1
O0 Oi
3
O X
[
1
11
Lo
1 rn
O Lo
03
3
O X
D) 1
X
I VO,
Lji i
'"O ( V3
<>
a*
SS
V<T****
52
3*
eS ro un r^ ^3 vT-
Q
cT>
nj < K
o< cr>
os
O
rfr <4* /
o$ os
Sfc S* Sfc
CO
---------LU LU LU 05
2555 >
03 Q3 2ZZ 2
wwMWtg
X <15
Q-L. EEo
8
03
.O*.3o.2O
EO ss
23>> O
oOr 3 cc 2 .2>o
X-1
o
tr
a0)
GC
v
creo
Q_
Q3.
CO
CD CD
CCOD
re
CO
o CO CO 00 05
oo < 5
CD
85
gT
05
> 05
` CO
CcD:
co
_i
CoO
CM
cn
a)
CO
5
jo
CD
Q
O
O Z
c
p
CD 'o
0 `c
az
CO
sz
o |2
0
E
O'
CD ^5
"x
Ck
0&
VI <v V
c, \ V <$ <o V
I
v \j NS
o
'o -Q
cl ~o3
O
O r^--a
c
o
o
O
rrOee)
Ere 5 re
0.
CreO
Q.
Ere I
CO
vo vD VO rV (.
O !
cw3o
O
Xl
o
1 1 iLr) Of 1
rv
co
3 O X
dre) /
X
<S `-o 1 1 1 CN
re re
Q
a r~s r>v
iv/>
r\
0mrc"*<>
s*
<>- ^$7.
a
''"W
o<
r><
Sunday Monday Tuesday Wednesday Thursday Friday
Saturday Totals
1
S* % *fc *fc *fc CO
CO _r_e___reL^U LU U>J Gg> )
oc ai 2ZZ 2
crEe
'9o3t
re x re re & _
g-ii. EEo
3</> ^o.3o ^o EoEtt 2 '5> > o uOr 3C
is ,s>o
X-I
r O
*
s;
tr 8.
CD
cc
u
.2
Q.
3CL --C/3 --
--
o<. svv^>s<.; tM,-&0S8MMW%%$f.
O
oo
CO
CD
rf CcoO 00 a
<
3> to
Oo o
c m-
>ra
di
O)
CO
c
CO _J
CO
o
CM
raCk_D_ 5
J2
<d
Q
M" r".
/ )
0 0
CO 0
E
V
O
o
o
Q3_
`o l_
CL
44:
-Q
~O3
2 c
o
O
cd
O)
n
CD
E
CD
Q
w CD Q.
Sunday Monday Tuesday Wednesday Thursday Friday Saturday Totals
M
Q.
Eco
CO
1
1^ os
m
Ln
os -
wk3.
XO 1
H"
o
1(
Oo on OS
3
XO
d0> /
X
*-0 ro
i ft
r-> ns
*5
Q
s
t--> ns
55 torri
y
^s> c-*>
rv
r~6
rv
r<
r~*
Oj ** ** 4* *fc tO
CO
__-- LU
.2 .2 g
LU
LU
03
co o>2 zz^
c" 0
E
0X0
8^1
to
0 3
3)rOZoL Est
Q
too '5o >o oOr
o2 >o 5CC
2 -S' o
X
Nortnwest t nvirocon, inc.
Sunday Monday Tuesday W ednesday Thursday F rid a y
.
S a tu rd a y T o ta ls
u
t \
tj-
CD CD
03
03
<
5
CD
I?a
OQ
CO 03
>
CD
03 CO
C
co
--i
CD O C\J
Ci_D
C3
5
jo
CD
Q
O
Tf
V t
c
VA
*
io
v> c
v
c
03
<D o
CD CO
'E .oc
|2
c .a: O
CD
E
O' c
CD Hi
ns
v
V V
v5 NS
u
03
'o
-Q
O
cl ~3
o u CO
k--
c o o
%
e M '\C 4
a
CC
/
/?"
U/ fJ,,
.3?
Q. .
Q3.
C/3- -- --
-
O) CO (D
E
CD D
CD CL
t/5
Q.
E
CO C/3
(
CN VD xS3
N
IIt*
C/5
3 XO
l
i l)
c? L? 03
o\
Vn C^5
32
O
X1
05
X
Lo *0
'-n
t ( 1K
o*J tf 9 9
CO r-s Q Os
t<S-I
r--
0 ' *'s f o^.
rH oc Oi o<,
::ts.
0
C'-y' r* r-^j
rv cx
*t *t *t 10
-T-O----T-OLgLI
LLI LU
$5
^
S
2C 22 2
X t<oD !s3 O
Q8-^il 1E
E
^
a
c
o
^
Uo5 '5O >o
O >
o o
u Oor> o
c
o
05 05
JZ
CO
05
E
i-
D
CD
o
%
t
8.
d
o
if)
Q. Q3. to
to | CD s
?
o
o>
CO
is
E
-- Q v. -- -
cl
--
o
c
ns
m nc
C/3
Q.
Eas t
CO
1
N
1l
(m Qi
>
V
v
3
O X
K .0
$
1
*"
\ 'V
>
0
o
03
*fc
`o O-O
cl ~3 o
Sunday Monday Tuesday Wednesday Thursday Friday Saturday Totals
1
3
0
1
d)
cc
1>
( (l
*5
Q1
ns $sl CSs
1I
1 Vn5s 1 1 \V rt
N
"' Z W L\
F; t'......
P's os
65
*fc *fc </3 ----UU LU LLI 2 .Eg
co 3 ^ 225
c 3 x w VQ3> Jr OW
_E9
HIE E o 7 0 0 .o3 Eo 3*
>3>'3 > o
oLLI
jOr 5CC
; .S> o
'X
d
o CD CO CD CD
o
o
I
CD
3 "2
8
U4
cn
CD
>03
CD
CcoD
CD
C CO _l
oCO
CM
CD lCO
5
_c0
CD Q
o z
V)
$
> >
s:
* <L
v
0
1C
CD '0o53 ^
CD
JZ
CO
o
c
03 d
CD
4fc
tar
0>
cc
(A Q. Q. 3 C/3
<D
TOO)
<a
E
Q k. CL
r^ CD CO
.a
cc
D g
("3r
m
M
CL
Ere
C/3
<5>
\
4 v5 .o
>s
V5
>4
Vi 4
vj ^3
O o 03-
=8: =
'o g
Q_ o
3 0 1
3 0 1
d> cri
CC
oo
SI
re
1
Q
I
>s
03
"O
o>N
03
T3 C
>s
03
T3
C
> C/3
03 03
T3
c/3
,,C a
03 03
33
C/3 H-
03
Q C/3 L-
3 SZ
I--
03 > a 03
a
03
03
_w 03
ttftft M
(73
c o
c
LUtULU
$55
g
zzz js
CO CO
x
QwJ
wQ)
^O
-E
-8i
E =
E o 2E
.9
'3
o UJ
U3
2
O
4
P> P> 2o
oO -c see
2 .2>o
tr
a
cc
o
to "o.
3q.
CO
T}-
co co
00
ooo I05 CD is
> 05
<~nL
( S<o <oQ --1 CM
CO
5 J2
Q o
"M-
o-
l"X
CD
CJ
\
5
5
Vj.
>
<>
0
o
03
%
Ou
.O O
c
o
Q. "3 O
Sunday Wedhesday Thursday Friday
1
;--------------------
Saturday Totals
o
CT>
<a0j
2
E
5
03 CL
(A 03
Q.
E<o
CO
(L3A_
o
X1
O
cLn_
3
O
X
o>
\
03
X
i1
1
i rt
03 m
Q\
ii
\
>
-T033 -
C
o
> 03
~TuJ r
03 C3
2 1--
----
i 1 >>
< i ns ns
55- '' /ft w* ,/A
i 1l
n$
*fc Sfc *fc 4* V)
---- LLILULL) J>
CO 555 S'
c o
xxx S=
to to jr O
c X 0) CD Qj
03 9-tH EEo
a:.E
*Q3
-8.*.22 E%
to o o o o
O '5 > > O
UJ
uOr 3 CC 2 -S'
I-i
o
sV
fO t C3 V3
Tl-
o ttOo CO CD
o
oI
>CO
<Ji
cton
/ l
05
e _col
to o
CM
05 $ _
Q
O
Tt h-
o vi
'Ai
c
CC
CL) `o O *c C0| .8
0
E
D C
CO
o Z 't
v3
\
Vj
~O
03
'o'
qI
rc^o.
\ co co
co o
s
-Q
5CO
DC
CO
0H :** <1:4* *fc *fc to
-------- LU LU UJ O
C/3 .2.2^5 g P
e o
0) <D Z 2 Z 2
mm4o
co
X <D 0) G>
Q-il E E 05 O
Eg "oo
UJ
8 .*.2.3
oUJ O3 >o >O OO uOr 3 CC 5 S> o
SWRf/Asbestos 3674
1 /'
I
INDUSTRIAL INSULATION, SCAI I'OLDINC, I'lUKITOOKINC, & UKI'KACTOKILS
c. n. im\ him u i n i i ( in M l M rm ini ' M :i kh i ........ minis ( inns11. 11;\ \s th ii.'i
. TiTT" i w isi.'i mii '".'15
ASBESTOS ABATEMENT WORK IS BEING DONE IN THE AREA(S) NOTED BELOW.
PLEASE ADVISE ALL OF YOUR EMPLOYEES WHO WILL 3E IN THE PROXIMITY OF
THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND STAY
OUT OF REGULATED AREAS.
7
LOCATIONCruJe Uni-f -T3 |
Pi^ercyc^Cj C<+
:OWNER Sou'UiuJe.S'W^n fcep>oiVj Co. ^-VlC.,
DATE OF WORK: FROM: 1.-2M ~1Z
TO: 3- \s-
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATION CO. INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSON:
ON THIS DATE, 2 *
_________ , NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TO
_(name)
OF . ..... (company
[A COPY OF THIS NOTICE WILL BE KEPT ON FILE AT THE JOBSITE AND AT THE GILMAN OFFICES. A COPY WILT. BE PROVIDED TO TIIE SIGNATORY COMPANY UPON.REQUEST.]
SliVRf/Asbestos 3675
"'M,
n.-.-i '*|rr i-.
('o
INDUSTRIAL INSULATION, SCAI'TOLIIINO, I'lRITKOUl'ING & REFRACTORIES
i*. ii. nos ni/i'.m ni.Mi iiiMi ii rnuNt. i ci i Kh wn, < < turns ( Hitts u, i i:\ \s 7Kn.v . it u f W iM.'i HKI iw,'5
ASBESTOS ABATEMENT WORK IS BEING DONE IN THE AREA(S) NOTED BELOW.
PLEASE ADVISE ALL OF YOUR EMPLOYEES WHO WILL ;JE IN THE PROXIMITY OF
THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND STAY
OUT OF REGULATED AREAS.
'
LOCATIONCroed-e/ 0^^ - Ts? : &o lers ^ Pi
Cb^" frucAv^
OWNER: DATE OF WORK: FROM:
C.D. T#ic< f
TO:?" /f- f Z
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATION CO. , INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSONJiJucZtc^_________
ON THIS DATE,
NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TO [, e.o )Y)endc Z-(name)
OF x C*&U
<-/ &, /
_______________ (company).
[A COPY OF THIS NOTICE WILL BE KEPT ON FILE AT THE JOBSITE AND AT THE GILMAN OFFICES. A COPY WILL BE PROVIDED TO THE SIGNATORY COMPANY UPON.REQUEST.]
GI LMjAN REPRESENTATIVE: _ COMPANY REPRESENTATIVE: DATE OF NOTIFICATION:
"Z - Zf-
(signature)(signature)
SWRf/Asbestos 3676
.O.r
INDUSTRIAL INSULATION, SCAI'TOLDINU, FllUTKOOl'INC. & lUCl'KACIOKILS
i', 11. mi\ mi i ,t u u i ii in 11 ii nilihi. hi hk i ............ oiinis rums11, l i.s vs IH.11.1 , 11 l.l- I \ V HI .'I UK l "K'lf
ASBESTOS ABATEMENT' WORK IS BEING DONE IN THE AREA(S) NOTED BELOW. PLEASE ADVISE ALL OE YOUR EMPLOYEES WHO WILL IE IN THE PROXIMITY OE THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND STAY OUT OF REGULATED AREAS.
LOCATIONC-Peil.
ft
OWNER;
fippt n 1
C ____ -4-k>C. .
DATE OF WORK; FROM; Z-Z^-^ZL________ TO; 3~ IS~" \ 2
__________
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATION CO., INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSON: /?JtU*Q
__________
ON THIS DATE,
2-Z^- ^
NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TO
OF _
3u)o-
-
(name) -- ------------ -- ____ _________ (company) .
[A COPY OF THIS NOTICE WILL BE KEPT ON FILE AT THE JOBSITE AND AT THE GILMAN OFFICES. A COPY WILT. BE PROVIDED TO TI1E SIGNATORY COMPANY UPON.REQUEST.]
GILMAN REPRESENTATIVE: COMPANY REPRESENTATIVE: DATE OF ..NOTIFICATION:
*? Z-
(signature)______ (signature)
SWRf/Asbestos 3677
Vmi
"Mi
r . )i.P".<
i /* ' uI
INIMISTIUAL INSULATION, SCAl'TOLUiNU, niUTKOOKlNG & UKKUAITOKIKS
r t. m>\ i it m hi u i .
11 111 : 11 k hmini
j hm t mu. < i hum is nuns i i, i t \ vs
INI IUiH.'i nil I "'.'Jf
ASBESTOS ABATEMENT WORK IS DEING DONE IN THE AREA(S) NOTED BELOW. PLEASE ADVISE ALL OF YOUR EMPLOYEES WIIO WILL ;3E IN THE PROXIMITY OF THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND STAY OUT OF REGULATED AREAS.
LOCATIONcVo* ____________
OWNER: SooVWyjJe.5 WiT n ?^p\s>i nj DATE OF WORK: FROM: "Z-1 'l~ClZ
Cc. IE>ic.
TO: 3
___________
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATION CO., INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSON:
ON THIS DATE,
**, NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TO
(name)
OF Ps.ok jTV'ic,.(company) .
[A COPY OF THIS NOTICE WILL BE KEPT ON FILE AT THE JOBSITE AND AT THE GILMAN OFFICES. A COPY WILT. BE PROVIDED TO THE SIGNATORY COMPANY UPON.REQUEST.]
GILM/VN REPRESENTATIVE:_ COMPANY REPRESENTATIVE: DATE OF NOTIFICATION:
signature) signature)
SWRf/Asbestos 3678
INDUSTRIAL INSULATION, SCAI iOLDlNII'lHITUOOl'lNG & HKI'UACTOKIKS
I' 11. ||||\ HIM JH lUMi'MI Ml H I'lHiNI 'M^iliKI rim. I (III I'l IS ( II l( I s I |, ||;\ VS 7KI(.'I
. mi- l \ \ im .'i mi i iii.'pj
ASBESTOS ABATEMENT WORK IS BEING DONE IN T1TE AREA(S) NOTED BELOW.
PLEASE ADVISE, ALL OE YOUR EMPLOYEES WHO WILL IE IN THE PROXIMITY OF
THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND STAY
OUT OF REGULATED AREAS. . _______
/
LOCATION: Ui \ A \ ?.1 >j
OWNER:
oMavJ
Rfi pjrt iVij Qp.
ZEUc.
DATE OF WORK: FROM; 23 3-
TO:___ 3 ~ / S~- 5 2
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATCON CO., INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSON:
ON THIS DATE,
Z NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TO
(name)
OF _____________ (company).
[A COPY OF THIS NOTICE WILL BE KEPT ON FILE AT THE JOBSITE AND AT THE GILMAN OFFICES. -A-COPY WILT. HE PROVIDED TO THE SIGNATORY COMPANY UPON.REQUEST.J
GILM/HE REPRESENTATrV COMPANY REPRESENTATIVE: DATE OF NOTIFICATION:
(signature) (signature)
SWRf/Asbestos 3679
^IM /.V'-'' "`Ml'
.U 1
::iri .
'/ .11,
r. . i
i
INmiSTKIAL INSULATION, SCAIJOI.DINC, KIKKI'HOOFING & UKI-'UALTORILS
r. 11. mi\ hi / i .m u i mi in m i it rui ini i m ;i Kh i mu. < inirns rim is 11, 11; \ \s 7H ii.i till' I V \ t M 1 Ml I >11.'IS
ASBESTOS ABATEMENT WORK IS DEING DONE IN THE AREA(S) NOTED BELOW. PLEASE ADVISE ALL OB YOUR EMPLOYEES WI10 WILL IE IN THE PROXIMITY OF THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND STAY OUT OF REGULATED AREAS.
LOCATIONC,AJ.le Oai *i* ^ ~T3
OWNER: SouHrLug!>V'fey'
6>o\l ^ P>
CcS tVjc^iKg.
Co.
__________________________
DATE OF WORK: FROM: 2-Zq--TO: j-lS-<iZ ____________
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATION CO., INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSON: /tertz**
1
ON THIS DATE, 'Z'Z'S`~eit
NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TO
_(name)
0F C
cJ
4err?
----- (company).
[A COPY OF THIS NOTICE WILL BE KEPT ON FILE AT THE JOBSITE AND AT THE GILMAN OFFICES. A COPY WII.T. BE PROVIDED TO THE SIGNATORY COMPANY UPON.REQUEST.]
GILM/ULREPRESENTA1
COMPANY REPRESENTATI^EgfAu^gsaE.
-DATE OF..NOTIFICATION:
Z ~ IS- QZ
(si g n atare) (signature)
SWRf/Asbestos 3680
INDUSTRIAL INSULATION, SCAi-TOLUl N(;, I IItKI'UOOl'lNC & UKF^ni.|
V. IKlN
(11(11 iTvTm--------* .H MM Mi lll.M | || . I llofs I M , KK I J M,,. . ,
IS CMIIIMI
ii.i i- i \s >si :i c i in.''5
ASBESTOS ABATEMENT WORK. IS BEING DONE IN TIB: AREA(S) NOTED BELOW.
PLEASE ADVISE ALL OF YOUR EMPLOYEES WHO WILL BE IN THE PROXIMITY (
THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND STI
OUT OF REGULATED AREAS-
/
LOCATION :C^r.r = IlAT.. C/?/?C KFJ? _ owner: Snum.LC'ZST^AL.-/fejEirtk&p.' DATE OF WORK: FROM:;?-- 92___________
_2TutAL .UASO.
TO:
__________________
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATION CO., INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSON: /tg R^jCT' /zrsP&K,7/V
ON THIS DATE, - 2 & ^92-
NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TO
________ (name)
OF -Slu?1^0S.16L . R.EpJ.rf.Jiy... O/y(company) .
[A COPY OF THIS NOTICE WILL BE KEPT ON FILE AT' THE JOBSITE AND AT THE GILMAN OFFICES. A COPY WII.T. BE PROVIDED TO THE SIGNATORY COMPANY UPON.REQUEST.]
SWRf/Asbestos 3681
r.vi r'
'J- . on .!.
rnfmoCO., E7
INDUSTIUAL INSULATION, SCAI'I'OLDINC, I'llUTUOOEINC & m:ruAf-vr,...
r. m. mix <117-1
,
hi m<'hi 7.ii'k nini. <<<;< hi- < iMinis ciikisii, ir.x\s
ICI.I-. I\X IMJI mi-i iii.'if
ASBESTOS ABATEMENT WORK IS BEING DONE IN THE AREA(S) NOTED BELOW.
PLEASE ADVISE ALL OF YOUR EMPLOYEES WHO WILL BE IN THE PROXIMITY (
THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND ST)
OUT OF REGULATED AREAS.
^
LOCATION:CAT T - CdT CftfiCXpIL ft#*#?, rfA/oTfa //-/7V6
owner=ScuffluJig'iTirRh] r^eFi\ieney
______________________________
DATE OF WORK: FROM: ,2-29-92___________ TO: ,9- /- 92
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATION CO. , INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSON: tfcR&gT'
s7/?
ON THIS DATE, 2- 29~?2_________ , NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TQ^ m.^a7!flO/FS7&eAf f&Ft^jeyCCptlTZtL fa,
(name) ny) .
[A COPY OF THIS NOTICE WILL BE KEPT ON FILE AT' THE JOBSITE AND AT THE GILMAN OFFICES. A COPY WILL BE PROVIDED TO THE SIGNATORY COMPANY UPON.REQUEST.]
SWRf/Asbestos 3682
INDUSTRIAL INSULATION, SCAI'I OLUINC. rilu:i`UOOKlNC & UKFlUfTni,i
r. <>. ii<ix wu .< 1.1 w i mi iii:m i.u i'iioni. <51 :i kk >- ............ ontriis turn si i, ti:x vs -jkji.v . n:i.i-: i \x im.'i b.-
ASBESTOS ABATEMENT WORK IS BEING DONE IN THE AREA(S) NOTED BELOW.
PLEASE ADVISE ALL OF YOUR EMPLOYEES WHO WILL BE IN THE PROXIMITY C
THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND ST7
OUT OF REGULATED AREAS.
'
LOCATION -.Q/dT' - CldT' PsfieJS&g tifJD ~fa(?i\J rftffuiirD PlP/klG
owner : DATE OF WORK:
___ RgJELkL&jfy.-
FROM:
Y?/V ~?2_________
TO: 3-- I - 9 __________
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATION CO., INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSON :
T~ EF<>
ON THIS DATE,
NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TO X &tty
(name)
OF E)#V /A/C >
y }(company).
/ [A COPY OF THIS NOTICE WILL BE KEPT THE GILMAN OFFICES. A COPY WILT. BE SIGNATORY COMPANY UPON.REQUEST.]
ON FILE AT' THE JOBSITE PROVIDED TO THE.
AND
AT'
GILM/\N REPRESENTATIVE: C OMPAH Y R E P R E S F.N T AT IV DATE OF NOTIFICATION:
0>
(::.i y nature ) ( n i.ej nature )
SWRf/Asbestos 3683
/`CT rofy.''.
\l' (',' tl,, '
K'iifii.n.;v. r)r'.rV''
INUUSTUIAI. INSULATION, SCAI'TOUIINC, IIKITKOOI'INC & Umfuacvoiu
*r, ii, mix -iiijj i n i mihi.m i n rmiNi iM.'i
4'""- ' i'tin ix <luu\M7Ti2vs~77iT
, I l-.I.I I \V I'l .'I HH ' !'< s
ASBESTOS ABATEMENT WORK IS BEING DONE IN THE AREA(S) NOTED BELOW.
PLEASE ADVISE ALL OF YOUR EMPLOYEES WHO WILL BE IN THE PROXIMITY (
THIS WORK THAT THEY WILL NEED TO OBSERVE ALL WARNING SIGNS AND ST7
OUT OF REGULATED AREAS.
'
|
LOCATION-.^r' T - OjlT C/?/?C KFP
owner: <Z6ur?fL&$n?/eti /fefritf&gy.i
7Tl/?a1/?/?CC!A/n &Pm/6,
DATE OF WORK: FROM: -Acj- 92___________
TO: .^-/-92-
ASBESTOS ABATEMENT CONTRACTOR: GILMAN INSULATION CO., INC.
CONTRACTOR'S SUPERVISOR/COMPETENT PERSON : /'j'cRFtfT
I
i
ON THIS DATE, ^ - 2 & -^2?
NOTIFICATION OF ABATEMENT
ACTIVITY HAS BEEN GIVEN TO
(name)
OF,2cKxTblLOPSTF/CAf tfltFiffgay f//y(company) .
[A COPY OF THIS NOTICE WILL BE KEPT ON FILE AT THE JOBSITE AND AT THE GILMAN OFFICES. A COPY WILL BE PROVIDED TO THE SIGNATORY COMPANY UPON.REQUEST.]
GILM/iN REPRESENT.
COMPANY REPRHSH.N' DATE OF NOT 1 F J C ATI Of J: 2 -- Z-
~ f 2-
SWRf/Asbestos 3684
SWRf/Asbestos 3685
SWRf/Asbestos 3686
4 [[GILMAWN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER::fl/'&A.. A/:' f.'l fAy........ _.........L*---------:
..ON lO,/ir-T~ Afy/^C/r- . /IC//7 A/Ati/A//) LA7'
77A'.'-"'
jiLMAN SUPERVISOR:/?^^r
. GIC JOB NO.
-ZZ^JL
I ]GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
*CUSTOMER: SpurHiOezlzAAf - f^Fj^/.AiF/ey y
y 2?rx>------------:
r QN: r-J^- rtL-rrt/OL '/a (G _. /?c/r7 /v/v/z C^7-L^'/jc '/%/>/-
OILMAN SUPERVISOR : &br -r
/? _
GIC JOB NO. 3f5~L
GILMAN INSULATION CO., INC.
CUSTOMER * r~~'
aT-X- fay
UixLMAN SUPERVISOR ''Mdbfrt.
^/7/L
ASBESTOS ABATEMENT JOB ENTRY LOG
(\;'f .irtiUTuf/?'
GIC JOB NO. 18^- r.
SWRf/Asbestos 3689
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER1:: ^a,-rMESTS./?A/
- -(m'-Cr?,.<n> 7C-A&/W6 /* '7iih/ j&M/p
<i
o XLMAN
. jzar&tf.:.GIC J0B m'_7fS~
GILMAN INSULATION CO., INC,
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER:
'jr,'
j//:// . /
* f-n. .
>*~ftp '/
.ON: 2^
-. h'kv/ivt
oiLMAN SUPERVISOR:' Robert~
ft .ft.
/.
rpo/r/ Mtf rt*v.uai ft/Rnft GIC JOB NO. 211
ji|i_DATE III
V. li
i NAME
i COMPANY
ji TI: ME IN
i TIME OUT
i COMME.N...TS --
il
I)
1
Josz. ftfez#
&u/.v7/?/y .
r!, /TJ/
tftfto A , rtl r
/ rR .`?, ' y-r ^-- .. .22 4? 4~T Riftrsl. '`7 .
-
Jesh yftftrft i ft,
/i //
R#/ Uft77feftftftoR/ S/6E ftpftC/P
/i i/!/i i
i
?; 3 0 -ftfc/7/ f?i/7 d. ft'
t1111
10:30... 744// EE.6 UA;2
ft n:'
?;so 8b///R`
i.
l 10!3 0 r! r sr? ' tonn
,, . / Gc- xlc-5 //ff-'R
(ft r L /??J?AE
jB! f'JS ////-y*--A //
I\
*ft/a'/- ft/s /RcrRfB ftp - u)/ ft/fp /4W ' fyfisrfc- /ffeftft/E
ii 1
/
ii 1i
i Vy k*
-v..
1 r-
S
/h tri' JO; oft d > /r?,
to; r /?/ /o (oft
,1,r?T
/lift" 3 / /?! ` /3,
/ /V , 4' /ft'
---
-. /
--.
-- 1
-- --
SWRf/Asbestos 3691
\ f1\ 1f11 Jji:
1G! ILMAN INSULATION CO., INC.
CUSTOMER: ^
t f- --
- -`C'.v >
_
^N: i YuPBGl
tILMAN SUPERVISOR:: j2of?-r
ASBESTOS ABATEMENT JOB ENTRY LOGI
_&>''/?
tv.- .. I*/:'-
-fi'AL/U-' i1 GIC JOB NO.
v
j|DATE
NAME
COMPANY
TIME IN
T TIME
OUT
1--------- -COMMENTS
------ il
/?.' -vr
// >
/: /?/
///
a it')1'
: ,J
-iJr
-r ..
/?->Z ,/f
1/ .?.// ' r-jS^/y:
4
xfaf'fZ
jc
IL
//^ &/?/?.*//
>' _v .
/ yj;
US--jL.
VL
yy>r/
L / -
/:^;V // ^=V
I
X /t\\//)A A-
A_ v:./
SWRf/Asbestos 3692
*i GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
customer :
Q^ftPu<l, .Qjk/s77 . T^S .
..ON: Cns,t,f,u,D. /j?4r-- 3T- &MAr/ A* sT7 /nZe/^a___ 'Zz^j
^//Z
GJl .LMAN SUPERVISOR: &igg2l____ESP/tAZ-g-
GIC JOB NO. 75I_
SWRffAsbestos 3693
upi---tW GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER ' Spu TKlO.X>7N .
r'
.ON:
33 - $F.mouB
oiLMAN SUPERVISOR:
. (detfPu3. .(lA/C/sTT , TXXrr,
8 Cf7l .Inform
/fi FiptfJG GIC JOB NO. 21S1
Ir" -----|| DATE
II i
'
NAME
i ----------------------COMPANY
JoS rfl&ZL/? . C.tL/PPU
|time IN
/. f>1 > .Ca:3L0.
TIME OUT
COMMENTS ---
P,rf> 3*0 0 FldUfh BftCn
j I
J
, \fxsu 5 h/Jxf/P \lk1 /TfrfPlwFt
\
..PC/77 F/7o/y?
*
. TjX/JaJ Fpaue/P |
i11
1 1
Li
c V.
n,
....
.
r
7
/Jo&. _ Q/f,ee/tf_
~r fi, oh IX'30
EpfA/6?
--
P,/7?*
3: go
.
--
s t
tNi
^___
doF STfez/?
fitrtt (d/lsM/________ X:j s"
/
Jesus
, lit,
f, tn'
/ i i
\
i 1
//
'
r
>
...
vv \n),1Mcs/to>M
/'Jof
ii 1
r ---*--------------------------
i
/
----
ti
1 1 j
! p.ol. y.is' ! hi/
i
--------------- ---------SWRf/Asbestos 3694
l
1
i
C
GILMAN INSULATION CO., INC.
CUSTOMER: -.0 CATION =
( J-
l J I' / ) K I 1 H Liu I
GILMAN SUPERVISOR:
ll =
j DATE
NAME
-T-EE^z
Ef~^ i /-i COMPANY
ASBESTOS ABATEMENT JOB ENTRY LOG
A
TIME IN
GIC JOB NO. 7,JTST 7
TIME OUT
T--......
COMMENTS
zhykc
7 / 1)^/1
t ^ E 1 / <7
Cl t I i v * t *-v .C~> jsh t; -v
7.-oc
2 - DO
:')C 3'^c ^ g- '
0 SC t, V ^0<-i '
1/ -jm ->
3- ` ?<'
! Cj^c' r
c.il.
j
s'
SWRf/A.sbestos 3695
--
1
` GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER:
Rs
* S'
V
' -ON: (\j r
I 'Y 1^,
' /;'_*S A i P/f
LiiLMAN SUPERVISOR:''ge&ejal____Fsp/fz/?
.*>ZPMSJ!Jk/$77,,
-LjL GIC JOB NO.
TBrx ',Ru
7
Jl-----------------
|DATE
NAME
r 1 1 ----COMPANY
j TIME
TIME
\----------------------- i!
COMMENTS
11
IN OUT
i1
i ^ Jo5- 77l^Z/7 . L-3/L/7?F
'7 * f} ^
7 r> i '
Q
i
f
5~"-^
.
"3a le 0&
t
k
, he.SU f> rfJ/fTfi ik>..
\
P- ri i:$o
:
PC //: -V' 0/7
\
^........... ^
l',oo
P /??' 77 5 0
u
7P.0.: t-rsj
I
! P P'3', 3- H
Jr V.
il
f
-
SiO^ ' Q>/7P<3//7
; 1
j1
P 773R
7:37 P ?77'
1
| Ba rlJ3`!!Jc p- /
EP'CUtuR* >t
flppfi/' ReD&au/??
PuV5 h/f3/>/?l0 ..
V
<=>
tfuPj/ P-95fG}0/3 f/7 Q /1/77//7?
i
doB.
X'-c* p, *? >
ft: ero P /?/' /5: e> o
J
|
1
777/z C^ CRPrk ' !
\! prtl'
//:.3o
6f</c^ \(
\i !
i
Je&ctS /7h% ,k,
iewsm. r
i
|! i
if
i
|
.
X tSy K
wm
\/o.
_____
(
1il' ttfpr'-v -r:''"fe::
t
I
1 -V
!v
I I
1
1I 1
f
SWRf/Asbestos 3696
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER : J&uTRuOZSTeEN , KzKkI-#..'..
r
, TZ-x .
.ON:
El
.1J1
LalJplJL
av/V/.
bl
oiLMAN SUPERVISOR ''JZd&SE___ kSP/f/Zz./?
EL 'MCttfr GIC JOB NO.
2 1.
'28.
ll------------
-------------- !l
j| DATE
NAME
COMPANY
j TIME
TIME
COMMENTS
jj
i1
j IN OUT --
1I
fi.rA' ft< n1 -
/'Zb'*?1- Jose rfl&zj? ..G/Le?/?t E____ ir.yo
1 CLJesus rffyfT/? }!&7
.
L 6 U7? ;C . U,E f fc" _ / /(T .EC./)' C:f/;'
Fmwo /7f#/e7wri7 t?V*;r7i{ /$/%/?j?
1
i /J} P/f/t'E E"
1
j
-BuE.DftJC,
IS. /^A|
i1
If1--
r
C V. ' Qaec/#
If rflfltflf/U iJoDUlGU/l fJutnv ' LokfGstf/E
^ <5 Z' Ofl^Ak JJopl/EvE: 7 JoM tTfez/?. Jesus /7U#,k. t
1
1
/
. A..... _
&/tL}/E/f/f/ 1 1i
iil1 '_i. -
\`
\1 1 1
3'lo
ffyX
'tktr?//. ^/7?aIE1.----------- i----------
j
t uitUteesmu
i1i1
!i
<
i.. V!
..... j/ V0 (JekO'/J
<S
/luPy'
L) owl^oESM
_______ !ii______ 1
i
!| 1i ii \i/
ft, rfi ' Mi3' \.\\ 0
I \
! !
\
! V
Ek/cLoSu /PE (iA-rClEc.,<
SU?-T'
,t ` |
! f
I
[
j
i ln il!l . jI:I
SWRf/Asbestos 3697
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER ' \QaTfja)^
.Cjfc/S77 , T^y .
*
c
.ON: 0sfl! 'X' ~ JAh(bz 1'f/'/? AT /:'
?T~- /r7/'3^ / ' '/S- '
OILMAN SUPERVISOR: jZoSBKIl____
GIC JOB NO.
21
KGILMAN INSULATION CO., INC.
CUSTOMER: f
.ON: O
ASBESTOS ABATEMENT JOB ENTRY LOG
. Rfr.h KpFfPP. ^ . Qg/f P U 5 \.j}Kf$ 77 ; '/
oiLMAN SUPERVISOR:
____kSP/tA&g-
GIC JOB NO.
il || DATE
II i
NAME
COMPANY
\lo5E rflzz./? , I^.5U6 p7?A7^ 1 k1
7
1
|time IN
TIME OUT
l COMMENTS
-i! 1 |
fh P7 / U:p5~ .";/
i
i
/I-rtf i2,
V30..... // ^ --/C \\
/V A r
>/-
7?^' PPPtSP/* --
/
^
1 ..
ti
PPP/' = - 1.
1 r. V.
7-----------------------
Not? ' Gmc/A
!
.....
i
i vK
C-7 L ptjfr- rp`/r~, Pvv. /
V tfC/P tPPj/py
.? /V;r
v\ ''1 1
.
11
doA
(G)i LnW P
/T. ^ 7 .3' .'<9
J&sus
Jg>
i 7k&?A/ ( .........../ &y vdi-fflmsftoM
1
^ -j
i~
i
j
1 1
1i i i t i
A'. ///
\ i j jj i
//-'
/\loef
i: 1
V
. 1 = SWRf/Asbe:;tos 3699
(
1 1 It 1\ \\
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOME:'RR: LOCATION:
dc^
GILMAN SUPERVISOR:
Rept^i^^ _________
Co. XV?c.
GIC JOB NO.
H 8S~ T
ll = ~ DATE
NAME
COMPANY
TIME IN
aWW EF<*m GuViey'tz & /1 yyiq /?
7 !oo
z\zfW Goq i<\\j oe^. Ce*r l 35 (SlIkTVi'l 73 <?
-z\isW Tesor> p^Oi^
G
\ n
TIME OUT
. * /o V.T
COMMENTS
\
6-^j
lo^sr (S/ov^c.
zWstaz UlcVo/ m. Cpi^4\ i. 0
`i\l*\ciZ
Cd i 1 m*n
7 Jo
73 <?
to vr
/1? vr
7.\trkz Osc^i' B. Ge^tiA zU^Z Ho/^cio COK)^
G |kv>c,/i Qk \w\c,*
.-7; *?
7^
/& yr fsc* f
to H* /4 O <? 1?**-p
s
ClWW EF^io GuVie*'ez zlzS'W &oqlc\\ooe*J. CtrV 35
i QAvY\Z /no
z\is\ Teso* p'loi'^A
G> \
-/no
zWsUl UlW m. Cackii Q
G>\\
n$#
zWtaz
CS/'J'r?^! tiQo
zlts'taz C^SC^)*' B>. Go^k'ClA G i \yYlc>f)
//Bo
tl/o / 7/i?
L. $A<i G>to> L
J}G O fAt 0 /
t^oo
fre# /
tolOO
ire/p
zWs'kz Ho^acig Coeuc^
Q\\w\Ot^\ i_ (I/O
------------:----- :------- 1
/J/o 6tout 0A X_____
:lman insulation co., inc.
CUSTOMER:
^
LOCATION:
GILMAN SUPERVISOR:
ll------------------
|j DATE
NAME
IIl
COMPANY
a\ zsW E Freon &jVie*'Z
ASBESTOS ABATEMENT JOB ENTRY LOG
Co.
GIC JOB NO. n8S~T
TIME IN
TIME OUT
COMMENTS
.
\
\
2\^W
Goq1
\c\o0e~5r .....
C<irr1 V 3S
7.\z$W TtSOi P^Oi^
G
zWstai VJitW fvi. Qst^-ki
tLno
<
Hip.
(3 to
zUfkz lVlc|^yt\ L-nrei.
Cd\ im^n
&(0
i\l*Vz OsCC[v' B. Gc^^cie, G \yyic>si
*2.\z-?Bz Ho/^c\a Cueueo
G\\w\c,*
.13/ H30
/too 6/o~c V
tgoo /bto / Uo IUO
(S/c &'*.}' CU+A
/o J's/? A s*\
(si c/a Gig*'v
Jc *s/0
s&-CCS**
(.si c/o JL/s C
C?/o*' C 0**" /
lb to
,f/y
______
l\ ZsW EF^eon GjVief't2
zlzs'W
\GoqiAooeX C-e*r'i 35
j
j
GAvm\
/
t\zsW Tcsoi
Ql Ikw^o
___ _
0zWtaz \Jvc.W KYI. Cas4'iL Gl\yyi<,i> 11 iS
zUrtaz
(Gilnosn |_ ms
/Sl (53 o
nt/o$ s r 6* c/o$ur e
['i\zrhz Osc^k B. Ge^cU Gt
/7lS m o /i tjofU'C
zWs'Bz Ho/^c'io Cu\JCvi
Gv\nnc,<i L
---------------------------------1
ms
)$}0
a cUl ure
bvvm/Hsijestos 3701 =
I jjt-w^y ....... ' ' "*"
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER : ^aTfj(VSTN , 8_E.5tJr#y_ ' Xk>^4uS.JUk/S77 , Tlrx,
.ON:. n ^-----T~ ~ f^ty&~GU#jo
ouxiLMAN SUPERVISOR:''SaBggH_____ z/7
GIC JOB NO.
h-----------------
jj DATE
NAME
|
t----------- COMPANY
------(TIME
IN
TIME OUT
----------------- 1,
COMMENTS
jj
Jos^ <\5u$
. G (Lrr? ti fi /
' 1ik i `
11
1
. M&S&L Z______
f.rtl'
f,rt7 '
__ 7-'5 _
. Tlf/Ur u 0
11
/ / 1 msfper
if
(1 1t
1
1
_____ i______ OhlvU^
, rfiS
1 Vl
1
1
11
* r V.
Mo& * Gaj?c//? .
-- - -
'
/___________
/
'
' 1
>/_____
t
do& tfZzzs?'
J&SUS
Jg<
?,rr?< Qrlaf/f-x/___ _
Ijti \o
-
Am/ 3v \
.
fl'trl' y;?o
''
4!< 30
cI
'&y uSiWs&M
\
/yfer Q/ftc/rf
!1 il
!
Vfeii;'^
\
H/
f
!i
1!!!
li \\
SWRf/Asbestos 3702
GILMAN INSULATION CO., INC.
IASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER :SdUTH(Jl>S>TGM ,
r
.ON: .O J.LJ=-
./^af^7a
oiLMAN SUPERVISOR::&aB_gL_____ ksp/t/Hz./?
Q#!ljJA^QJkt$77TXx X>\neT~
GIC JOB NO,
lr II DATE IIi
NAME
r --
COMPANY
j TIME IN
Jose )X!e2-rf ..GtfOrfP/S ._. , fe:5ry.6 //^/0 i k .. . y ....
7
fl.ttfr
3
A>W' 5:oo
rfMTftr M/tfii/e^...................... tf/fr uJ/7X&Z$Poohr
S;a O
/h >71 r
3:*t>
TIME OUT
I -- -il--------------- ----------------------
COMMENTS
II
j
/? /tf '
^ CR. ,, . T Le/uru P
tk(.f/ P/~ 0=&e/
eA/cl&irsj ee
1l 1 si
i
|
C V.
II
Xoe m Q/&ee,0
. .,,
3X0
>/
/
t
1J
1
1
Jesus /XfoX Jit* 7
X tgy uifflg&ttou .... /'Jo? Qxxa/?
!
----
't
1 1i
1
. i -- SI/VRf/flsbeistos ,17m
j 1!
i
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT SOB ENTRY LOG
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
,CUS^TOMERL:: .xS&uT}fuJS12*N.- ..RzBkIFO//. .. Q*ZP.lL$J1A&SIj r,
k > ON: /) ~r~
L*L!------- s
& to US' ,,
'iSl
~r
T^x ,
oiLMAN SUPERVISOR: Baamn._____ kspfiz-/L.
GIC JOB NO. 2$*-L
II----------------J|DATE
II i
NAME
i-** * JoSf
1" ------- ------ - COMPANY
. Q(Lw#fj
TIME IN
TIME OUT
COMMENTS
/?, /fl /
p. ti
l'3o . ll:/S'. . GlocsM
j !
, ks/7 6 rffa/a Ja &?/>5rr?0 Jffo/tlM&i
.. \ ...
i
____ BBSf. :7!/ 7^
Qtf"/tf/fz/S C>1 l#/T+ P * "
11 l
1
1
c V.
jj
rio/? ' Qoee,#. ........
1
O0S A/oM?
/
.
kjf. ^
2/%rJ2#c/c
s
i
do fTferrf
Q /l/T?'rfA?
JffSUS
,k.
A/rh 12!3o
{],Mh !;%d
\ \
1-- )
t k bs
C /<&V \rf,mZSP00A! --\ u C.
\/joe
Am ;
11
4 ! k/
1
!i
SWRf/Asbestos 3706
1 I!
j
11
11
|1 1 S
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER `3qla'TRuJFS72sN .
Fiu^
, 7^x
`0N OyiFfO-'TO - bUo^
i F6
OILMAN SUPERVISOR: RoBAZlO_____ kSPAAZ-FL
GIC JOB NO. 21W-2--
J(------------------- f..... " ............
|| DATE
NAME
11 l
..... COMPANY
j TIME | IN
TIME OUT
- COMMENTS
i) |
|
Pl'rf'
fi.rrf- .(Z0>\)F 3fisJ,5
Jose 0/1ez.A
Jesus j/JaTa
Or > (fJ
!
i 11 i ' !
\ !
l 4/2ST.
1
--l-- Ac.tfl
1
fen eF
!'
3 L/Fe o/j |
rfMTftf /$/!%/&
' /X
y- ir
XT
i
Af>F7Tf CffF'1
fife /OfcJsl
i1
C
__________ li
A'o& ' Qafc/A
/
i /
\/
l
JoF F/JeeA Jesus rffa# J/,
*
-
?
ffatf/A/ /TfaftAfGl. >
X t<&v \d;TifZS0ooM
Joe t
QMC//?
\i !
. u
li s
\
1 lI
j
1
_ MRf/Asbe
stos 3707
=|i
5ILMAN INSULATION CO., INC.
CUST0MER; SJwetU
LOCATION:
ASBESTOS ABATEMENT JOB ENTRY LOG
Co. r,,c.
SWRf/Asbestos 3708
GILMAN INSULATION CO., INC. CUSTOMER: <T ,11 LOCATION:
0,, ' r
ASBESTOS ABATEMENT JOB ENTRY LOG T
GILMAN INSULATION CO., INC.
CUST0MER .-(CATION: Cc-V GILMAN SUPERVISOR:
DATE
NAME
UvVG
hkZL
r 1 ~ ... COMPANY
7! zshz FFrc, in Co^eftez
ASBESTOS ABATEMENT JOB ENTRY LOG
r\
Oo
't -
A- i i c .
SWRf/Asbestos 3710
- "~ TIME IN
7*00
GIC JOB NO.
TIME OUT
7*00
COMMENTS ^/Sp.
ii
z\z?Mz. oOc,(U\oce J Qx.r<hi Gi
?|?
iY) 4^4
(s>1 > Aa C< 1
z \z%\az Vic*W J'V\. GsG'f(lo
,a t (pi jriKtl
i\
? h zhi
QscX r
&.
hrc'i*
- GsUc^
'Izgki ^ocacO Cuejes
Gi 1m<w
T`50 ^ 1 i ^>0 ^iV> Gfo ue
7'20 ^
G.*W 1 \ ' 30 U 1 1
4
J
n/ 1 0^* <1 rn
\ ^ 30 pip's
SlouG
'is/^Os
0 :io ^ \\l0p^
i
1\ 1 30 *Jrv\ Cyioi/e
flic'ioc Saline,?
(Gf
1 'JO 6, A,
Gio^t &qc
AzsW 6. J Czy\vjs 2)28^1 oesos, rncf^
Cr> /'I! .Hn <; /->
zWrU? \
Vj-Gof f'*'. Cc-;Sr ' J
(TscCf . (ie.t'ClS
6/
Spim Ca
z\zA$z
Hoy^co C.OJu<;
G>/
z \ib hz
Gt 1 /mr>
l)zs)c>i 6.3. Gr- * Vo$
{7, jrrtcn
z\z^t "Jesoi
7 | 7 4 7 \J 1 c\ 0 r fn .
/* ' /
/%/
74 S / //7'7 ^ ;
3'. ss pn1 &/ouc >^6,
rj
Glooc I^c;
1 I'TSfi*'
J
^'SS prn 6i')J0
(t! ? 0 r,1 /Vi 3 * A S' *? /vi GlooP
r 0 '55
G|g(JP
J X'
3 .irh I
"/ '7 ,,,,
c/;i7 ^
31 AS firK\ Glov'O
h' 0
J >lou? G?0
J
Ooof ^ j>pp
i ------------ -------------7~
t/:(70^
1 1c
G lo i/e ^ c (
W ' ' "* pi/n
......... --1------- -- " ' '7
GILMAN INSULATION CO., INC.
CUSTOMER: <^, ,K-,,, ^
LOCATION:
1
'
ASBESTOS ABATEMENT JOB ENTRY LOG
nC,
^
GILMAN SUPERVISOR:
DATE
1 NAME
Q-X^i vfT '
COMPANY
z\z$`hz S C. ^
tt
? 1 2 g ,k 2 M o rc *
i'"' <1
C `J e 5
d) i/TlCrf /~f Klii } / c~. / '>
A'e'iOS Sa ! 1^5 *
V
(CV hn iCrt
GIC JOB NO. 72S"T~
TIME IN
TIME OUT
COMMENTS
.... il
V - n^
^WU,.
^ /1,
"Y?;Gv<f
V' (f 1 s ,} /}
LKH ^ (f OAJ' 1 :> ` -J ^ c k._U 1
/
--
/
SW/Rf/Asbestos 37 U
OILMAN SUPERVISOR: faftezr_____ kspsf#?,/?
GIC JOB NO. .7SS
ll------------------- i
j| DATE
NAME
II i
,3 1 Jos#
COMPANY
, \s>jL/7'/Wki j
.1
7i
| TIME IN
P, W-' 773 o
TIME OUT
COMMENTS
1
|
!
p,m'
i:70 . . .gri-OUS? PfcG? ^
/7C/?7
i .11
1
f&fr uJ/TferttPtvN
! i
\j
J
ll
(\) v_
IL
si f? C /7\3 J
'-
A
/
/
/ . __ n< sc*, - .--*
GuLtfgtj
J&5US /fUfi.dlt*
P'/r?!
I/D',00
p.gt
u:l
1
7
Pfe/V/Af tfdrff/AltZ?.
(' _ ..t 1'
^ilVe^SflooM
'Jo? /
ft/f/tC/rf
; !
i I
1:
, ) 4. - /
& yL '
.. 1____ Z. -.-<T_
I
. .......................... ! ..
1 1
1
V3
._i-
1 l
.....
t
// 1
J ! 1 ! i lHi
s!
li j:
SWRf/Asbestos 3712
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER
\
-.ON:
fl ' -
/r/-> - e?>
GIiLMAN SUPERVISOR: ge/sC-_____ esptfgz./?
'//// /
JIS--GIC JOB NO.
[1 [DATE
1 i
NAME Jo5F
COMPANY . GjLvftLf
|time IN
a: 30
TIME OUT
fl > n ! <
------------------- ii
COMMENTS
|
!t
.i_J/3^....- . '(4too-'
, Izau a
a? r n''
rTfa/S? ik1
\ .JU5L..
A- V1'
?1 4: /4
LJ__\ \
A ,f/1`
\ 3; 30
k/'
IL
1
i
_i_ rf, r?if
VV .d/--
c V
. 4%5l r:/,/ T
II
/
' k- tf'J fl4/
fl, r?4 o u ;io
J&SuS
ik.
>
t7 flktr?A/ /7fcjrt?AT&?:.
I
i i i
4 ! 4 b~ A,**'
A :oo flirt'
' i 1
(' /<frv \d;7%f!5PooM k
V
.
1
____ r/<Joe flMC/fl._
fi ESt?a/ ti
!i
!i !! i SWRf/Asbestos 3713 J|
GILMAN INSULATION CO., INC.
LOCATION: CcA. GILMAN SUPERVISOR:
1 DATE
NAME
j company"'----
*2. Izi'n i S 2: E'frvn Gjke^2
ASBESTOS ABATEMENT JOB ENTRY LOG
x^ C , UkM 4-
GIC JOB NO.
TIME IN
TIME OUT
l" ... ..................... COMMENTS
i Lp 10 Oo a-
/s
(Gi^iGoe 3. Gnioi,
? WV>7
rTU*U
<oi |j/y]n
OlcW m. (GGiG 6 /' 1 kvi a n
luG koyo
G>;
Z^Uz OsC^Y S G^<U iWW Wor^CvO z\z(\\c)l 4 lex Scnl'i^s
611 m < n
Gi' IvW M 5 &n
7'. 3a,.,
U`2o,m GGe Bcm 0
*7 *3o 1 r3o*> *v n
"'2 0e,, &loue tG* J
r\
U'ZOc,^ LoloW 1 1 2. oi>i /Zi. ,, n-'2D., G i o^e
i^c. J
X.- y J
Cc-a
j
7 n'2oa,, GW iG c
J
Gloue "W
7\l^l <3ucx \j,}f 3 CeYY\-
z \l c \c'- z
7 \j!c4o^
Gs^ h
kol-b ko/0
(..J; !f ii /Cy 1
Cy)i\v\C-A
N} 6 / k> f CH
2.\zci Ul Osc^r ft. Settle G i \ vV\ C ^
7 1 ? c 1 ^ 7 \'-i,O'Cc-1`0 Cv^OJ'i i
fllfX Sjlrn^s
(~) / 1 |/W c.i/' G / l W*, C,tA
12 `20 a-i-i 4 ^0 fi/r Glove 1 ? u :onJ ir/>? Glove
3 Em
Ll '00
G\o\j 6c, ^ -- ---j--
2 -?0 offi I
Ll;ooM Gl ov e ^4 J -- -----------------------------
2 'Zd Q/Y~> Uoo
rr
Gfoue. fe>4C, ---------------------
Z -3 <3 j/-*, ^ -OO Q/Y) GIovp eg
i c 3
L('0^p/Y)
,J l
GW St c, j
__
bVVKT/AsDestos 3714
[igGIiLlMmAaNi INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER * - ^0U f(4(V5Tj?N , R\t?.hki&/ey.C^/f Pti 5.
* vrV .ON:
77 . 7^~jr
Lvj/IiLMAN SUPERVISOR:''jS&BBgn_____ ^.Z#z-/L-
GIC JOB NO. 2151_
II
|DATE
!
NAME
o-rt-n Jo5B fll&Z./?
1 " " .. "
COMPANY
r">.' t "t '
TIME IN
p.
7:3<?
TIME OUT
................................ 1
COMMENTS
j
!
f, ti" -
. &LO t)
, kst/^
)k1
7
-?
\
dC-tf? '^7/r
tjfiUG
1
1
M
C-' V.
1
1
1 1
1
)
V V'
~
*
( ...
c
1
i; ii
<lo? ` ' ' '/
Jesus Jt,/rf/vZ
/?#$)??0
t
-7 \
_ &v uiilMxspooM (
/'Jee
(7M0/?
'
v'
f, /'
JOJC-O
k /^'"
-
1
i/
-
,
I
1 l
i
.
1
1 " k.
1
1
.. 1
SWRf/Asbestos 37 J5
j
J*
I
11
1
GILMAN INSULATION CO., INC.
ASBESTOS ABATEMENT JOB ENTRY LOG
CUSTOMER : ^puTHio/ssTjzgN
r
.ON: O
. %eFiKtrr?</./'
i .C/kK77 , rs-.
G1l LMAN SUPERVISOR ''Be&ttlOl_____ kSJ?Az./L
GIC JOB NO. 2SS---
l! [DATE
11
NAME
i -- '" COMPANY
(time IN
$; ,-/'
TIME OUT
< rri '
COMMENTS
ii |
|
O " ' - . Jo5E . \tP5U 6
]ki
/TfefTwert7
.12:50 . 2; 3^
"i 1i
_ ------4-
1
r
. ,'^LoUP 3p'5$\ ,,Arj?7.
,
j
-3
ii
r V.
II
uJ/T/fmsPoosi slou? Qp/?c/tf
. v/. ....
i
\y
/
#
f\. FT: i
&t loP tff&r/?-
: Lrfi$}J 3:po...
--------------- ------------------
fd&sus
i
Jt, 7
iiii
(
!
_. ti}/ -- " ~T/i ~ '
X 1
11
11
1
'1her/A/ /TfcsrtAfe?:.
C s&v u)t1Mts/toA}
K. /
1
L_ _ _ _ _ L
\
i
\
.. 'n/
i j
\i/
1 J1
.
ft, M* SjG(i >
i/
i
i
/i
i i
i
4*
//
~
sm f/Asbestos 37 j 6
1
!
ii
!! Si
SWRf/Asbestos 3717
SWRf/Asbestos 3718
incidents or accidents mit.' inc, turnaround SOUTHWESTERN Rfc'.FINING CO. .INC. ASBESTOS ABATEMENT PROJECTS
DATE;
COMPANY NAME; $ f L Pi/}Fu l * T/ ~ CD. ^ C.
ADDRESS :
An 7 A
EMPLOYEE ^ME: ^ % ^
Co/P^S' cAs.T ^ ljJZUJ <2BIRTH DATE;^.
ADDRESS; jp^ T, S4^T/L QfX-F K'djSoAJe . 7?**f
S.S.S cj ^
__ / ^
D.L.OR ID.#
INITIAL FIRST AID REPORT
DATE OF INCIDENT: Jl-
TIME OF INCIDENT:
AREA LOCATION: CAT X
INCIDENT: ^^INJURY:
OTHER:
BRIEF DESCRIPTION OF INCIDENT AND PERTINENT FACTS:
<OscAiC. /->; TZX-e.0 TMiT SJTi
c^h SUAtf
l~J; 7A Qu T /~//T&XS g*> /As sr///? F-.___________________
MEDICAL TREATMENT REQUIRED: YES DESCRIPTION:
IMMEDIATE STEPS TAKEN: QSc~/ht- Si'T
-7 d-F j/Hf
/ju (Zloludru /fasti t/dsr>flLeO
^ F/S-J~dsFS 0-^
iA/> s>d*sAz
PAGE 1 OF 2
SWRf/Asbestos 37ig
C ause o f In ju r y o r Illn e s s (C heck w h ic h b e s t d e s c rib e s a c c id e n t) SWRf/Asbestos 3720
oT 0
f--1 p
0 0)
p
sn
c 01
G H
>3
10 Q) Vl
c CP
0 01 3 < p Vi --
Vi
3 O "
pP C G
o
p ft 0 P P Vi
o H P Vl TJ
G Vi P >iP O' M Vl
0 O P TJ ft C
o T3 0 W P to N
C G fi ft G 3
0) OO H 0) O X
TJ TJ G 01
Vi U M P
ITJ It)
P
N N - Vl
O' <0 id 0) 0
G X X >i o to
P p H 0)
*0 O' O'P
P U C 5 0) P O'P O' C Crl M --
W O'O.XPGCOCPPPOl
0 Vi -H -r< ID id O'P p P Q, ftp P Vi
P O 0 B <0 Vi P O'P Vi ft ftp P 01
ftO V ID 9 0) D1 (J<iD 0'H*H HI ID
x <h or: o wftfeuasoowwwh>so
c o rl
p
0) H
u 1/1
3 np
fOt
(U c
o 01 Vi C
o Vi ft
a) o
ft P
ft rl o P
3 >i O' Pw
M (d
ft N
BP
0) H Vi
P Vi
0
(d O b p p
w o pc
O' a c ap
Vi p
<3
0
Eft
tn P
to p C 3 3
p o P 0 O'
r--1 p * PM
03 P u Vi P
01 (TJ
O P Vi
0) P >1 3 3 0
ft to p
CO U 01 Vl P P
P 0P C 0
to fl 3 Id
0 0) 0
P P O w O'b E f! 01
0 <0 P
G ft P
< CO P 0) rl 0 P Vl P
C 0 to p p 3 01 Vi
0) D ft D P O1 ft 0
p P C M 0 to
<0 P 0 0 MO Vi 01
(0 (TJ P P >1 P O' ft Q
G id Vi P C E
9 O' 0) 0) P 01 C p H 1
C Vi Vl ft ft 0) P
P 3 3 0) 0 P id O' u > p rH (0 Vl P Vl C 0)
rl *rl H Vi ft id ai p p
Vl ITJ (0 O E G ft W P
a ft ft X w H O D O
*
C'- * p o ri
B
r* Vi V
O' G
PvO j
O
Vi u
3 ft a
IV
to >1
<0 H
3 Vi
oj
*
\
O' ft
co
P Vi
O ft
*0
to P
ViId
*
V
0) H
I*
$r
5: \
Pp o
p 3P <0. M O P P -n
3 to c to
p *rt P
(0 to
P *0 (d POP
*
0) P ai
ft
Vl o c
J O P
3 0IP (tJ U 3
G 0)
fSl
OM
0) 0) Vi (d
0) 01
P
>1 >1 (0
oo HH (I
G O
N
ft ftp EBP
H P
ft
HWP O
It)
tfl T3 tfl
<A
<0 id id 0)
3X3
>
ri
.V- p
*z *
o 0) Vl
s-^
Vi O U
Vj S.
to 0) (0 to 0) G P P 3
P O
(0 V 0) p B 3 z
ffl
G O
Pft
o G 3
10 a> to to 0) Vi TJ
T<J
(0 01 B (0 z
GILMAN INSULATION CO., INC.
WEEKLY SAFETY MEETING ATTENDANCE REPORT
I ACKNOWLEDGE THAT I ATTENDED THE SAFETY MEETING COVERING SAFETY TOPIC NUMBER 2L AND THAT I UNDERSTAND AND WILL ABIDE.BY .THE ITEMS DISCUSSED DURING THAT MEETING WHICH WAS HELD ON Z. / g: 7/S 2:
FOREMAN_
n ($J
________
1 d>.
2- c/^rrv i o .
C3` Woe^Er;
A'Cua !,
"E>.
7^0 ^
6. 7. 8. 9. 10. 11. 12. 13. 14 15. 16. 17. 18. 19. 20 21. 22 . 23 . .2 4 . 25.
26. 27 . 28 . 29. 30. 31. 32 . 33 . 34 . 35. 36. 37 . 38. 39 . 40. 41. 42 . 43. 44 . 45. 46. 47 . 48. 49. 50.
SWnt/Asbestos o/zl
INDUSTRIAL INSULATION, SCAFFOLDING, FIREPROOFING & REFRACTORIES
SAFETY TOPIC II 2
LADDERS
CHAINS, DRUMS, BOXES, ETC SHALL MOT BE USED FOR CLIMBING OR WORKING PLATFORMS.
BE AWARE OF SLIPPERY CONDITIONS ON SHOE SOLES OR RUNGS BEFORE ASCENDING LADDER.
LADDERS SHOULD BE INSPECTED BEFORE EACH USE AND SHOULD NOT BE USED IF THEY ARE DAMAGED OR DEFECTIVE.
LADDERS ARE NOT TO BE PAINTED EXCEPT FOR IDENTIFICATION PURPOSES.
DO NOT USE LADDERS FOR SKIDS, BRACES, WORKBENCHES, OR ANY OTHER PURPOSE OTHER THAN CLIMBING.
IF IT IS NECESSARY TO PLACE A LADDER IN OR OVER A DOORWAY, BARRICADE THE DOOR WITH PROPER WARNING DEVICES.
FACE THE LADDER WHEN ASCENDING OR DESCENDING AND DO NOT CARRY ANYTHING THAT WILL PREVENT HOLDING ON WITH BOTH HANDS. USE A I-IANDLINE TO RAISE OR LOWER MATERIAL OR TOOLS.
KEEP BOTH FEET ON THE LADDER RUNGS. DO NOT REACH OUT TOO FAR OR PI,ACE ONE FOOT ON A LINE OR PIECE OF EQUIPMENT.
FACE A LADDER WHEN WORKING FROM IT. A SAFETY BELT IS REQUIRED WHEN WORKING FROM A LADDER.
ONLY ONE MAN ON A LADDER AT ALL TIMES.
METAL LADDERS MUST NOT BE USED NEAR ANY ELECTRIC LINES OR SERVICES.
STORE LADDERS IN A PROPER PLACE OUT OF THE WEATHER WHEN NOT IN USE.
STRAIGHT LADDERS SHOULD BE POSITIONED SO THAT FOR EVERY 4 FEET UP, THE BASE OF THE LADDER IS TO BE PLACED 1 FOOT AWAY FROM THE OBJECT AGAINST WHICH THE LADDER IS RESTING.
USE ADEQUATE MANPOWER FOR SAFE PLACEMENT AND TIE DOWN IF NECESSARY.
STRAIGHT LADDERS MUST BE ADEQUATELY TIED OFF WHEN IN USE.
THE TOP OF STRAIGHT LADDERS MUST EXTEND :t FEET BEYOND THE SUPPORTING OBJECT WHEN USED AS ACCESS TO AN ELEVATED WORK AREA.
PAGE 1 OF 2
SWRflAsbestos 3722
INDUSTRIAL INSULATION, SCAFFOLDING, FIREPROOFING & REFRACTORIES
EXTENSION LADDERS MUST BE OVERLAPPED A MINIMUM OF 3 RUNGS WHERE THEY JOIN TOGETHER WHEN EXTENDED. AFTER EXTENSION LADDERS HAVE BEEN RAISED, CHECK TO SEE THAT SAFETY LATCHES ARE ENGAGED AND EXTENSION ROPE IS SECURED TO A RUNG ON THE BASE SECTION OF THE LADDER. DO NOT TAKE EXTENSION LADDERS APART TO USE EITHER SECTION SEPARATELY. WHEN USING A STEPLADDDER, ALWAYS SET ALL FOUR FEET LEVEL AND LOCK SPREADERS IN PLACE. DO NOT USE LIKE A STRAIGHT LADDER.. NEVER STAND ON TOP OF A STEPLADDER. DO NOT PLACE TOOLS OR MATERIAL ON THE STEPS OR THE TOP PLATFORM OF A STEPLADDER. STEPLADDERS LADDERS MUST BE TIED OFF IF POSSIBLE. PAGE 2 OF 2
SWRf/Asbestos 3723
GILMAN INSULATION CO., INC.
WEEKLY SAFETY MEETING ATTENDANCE REPORT
I ACKNOWLEDGE THAT I ATTENDED THE SAFETY MEETING COVERING SAFETY TOPIC NUMBER^ 2? AND THAT I UNDERSTAND AND WILL ABIDE BY THE ITEMS DISCUSSED DURING THAT MEETING WHICH WAS HELD ON 2 ' Li' f2L
FOREMAN
Mt // '.
1 * \/fdJ6UrxiA^ VW
3: \b-iJ
*
26. 27. 28.
5,/L^
------- -
29. 30.
31.
^ ^ . /??. "^iw .. nyi
32. 33.
34.
35.
ft3 3 * />7 jCfcL*\.
/[Jt~Tjsr\ o/^
y^/a.r4/pt^y
13\\gs<? A. He^9
36. 37. 38.
14 (kA //y'
16.
/^
--- 39. 40. 41.
17* 42. 18. '4"3 7
19. 44. 20 45.
21. 4 6.
22. 47.
23. 48.
24. 49. SvvRf/Asbestos 3724
25 . 50. H
S' s cy
INDUSTRIAL INSULATION, SCAFFOLDING, FIREPROOFING & REFRACTORIES l\n li(>\ lin I - Ul WT'.l I III SI I it |*l II IS I IM.'I nit I I'llll, . I ll!l*l 'S I I It; |S I I II \
il l i i \\ isiji Hnn,*is
SAFETY TOPIC #*20 ELEVATED WORK AREAS
Safety belts MUST tied off to a stationary object capable of supporting you in the event of a fall ANY TIME employees are in an elevated work area outside of a complete handrail.
When movement from one place to another in an elevated work area cannot be executed safely a proper "lifeline" must be secured to allow for safe movement. Some clients require that a double "D" ring and lanyard type safety belt be used so that movement can be executed keeping one lanyard tied at all times. Some clients require full body harnesses instead of the "belt" type device.
IF YOU ARE NOT SURE OF SITE REQUIREMENTS REGARDING ELEVATED WORK AREAS ASK YOUR SUPERVISOR **BEFORE** YOU ENTER THE ELEVATED WORK AREA!!
When moving from one place to another in an elevated work area (outside of a complete handrail) or when climbing or descending a ladder, both arms and hands must be free of tools, materials, etc.
Tools not worn in pouches, materials, equipment, or other items should' be~raised or ' Tdwered~T<5' of from 'the 'Wtnf^affesT'by use of an adequate rope. Do not throw or drop anything from elevations.
If using a bucket for raising or lowering small items, ensure that the attachment to the hoisting line is secure. Plastic buckets are not permitted for raising or lowering items.
Secure all tools, material, equipment, etc., while in elevated areas to keep them from falling from the elevation.
Areas underneath work areas should be barricaded to alert other personnel that overhead work is taking place.
Be aware of slippery conditions that could affect your footing. Leather soles are not permitted.
In our geographic area the influence of the wind should be constantly considered while working in elevated areas.
************************************************************
Use only ladders for access or egress to temporary elevated work areas. Use of piping, equipment, scaffold legs, beams, etc., for access or egress is not permitted. ************************************************************
T SWRf/Asbestos 3725
IND1ISTIMAI. INSULATION, SCAITOl.mNC, niM.IMtOOriNO X IM- l-irA<"! (Mill'S
c i>. ii(iv :iw: - .1 n u i -. i< in
ri u ivi c.t m >:t.> r. < < nii-t :t<:i-. ti > . i I'l i-' r.\ \ i-'i '.i r; i ii.-.'i,
T Ml TIM. FIRST AID REPORT
DATE: 2 -20 DATE OF IIIJURY:
2 - / f- J 2-
TIME OF INJURY . fl&D
/7?'
EMPLOYEE : AJo*
E - E - II
~ 7739
SIT F :-5" L<J <S> /Z ____________________ AR F A :
I N.'i 11RY? I*'' OTTI EE ?_____ deucetr-n ON 2 '
>A/ jTJg' /aJSJDJJ
___
Sr/?/&ZL
treatment /y/&7' s?/ZJ
/?a/> /? JZ9A/JJ/JG&'
Ife te&f 77/ t^ouA/O CLg&tLt
MEDICAL TREATMENT REQUIRED? J/&
DESCRIPTION
_________________________________
OSUA DECORDADLE? j/Q WHY?
/N \luAJV /4aZD U&/LL
Be 6>BSXV&'O 7%eu____ eur' Tfte' JoS
now DID ACCIDENT/INJURY OCCUR? effl/Bbt/ise tjQfis
CJ-tiriffWe
/ftrp
'TTtie'
foa)*/ Fke/r? rftXeSToS pa/^7e.ig.
//?s LeFf /o^/?/?/77 <pa/
.
WITNESSES
Tporemah :
OP INJURY? 3t>d
/J/77,______________
ITT'-'N ri' 11v\'
M DTD FOREMAN FIRST KHOV7 SWRf/Asbestos 3726
SWRf/Asbestos 3727
All sums due hereunder are payable In Slnton, San Patricio County, Texas.
CUSTOMER NAME. BILLING ADDRESS
y$ Ml -t~/: i j
SERVICE DESCRIPTION:
Pick-up Location______ ___________ Well #___________________________ Lease___________________________ County.
3'Waste Systems' BR0WNING-FERRI8 INDUSTRIES P. O. Drawer C SintorvTexas 78387-0187
Si 2*'-*364-4232 ^ /-~f /
r
Delivery Location.
WAYBILL
27358
TRUCK# _ _____ DATE 9s" A . p.o.#________ .PHONE
TRAVEL INFO:
PICKUP & DEUVERY TIME RECORD
- Begin Time ?> .
____
"TIUP 1 ftAniWO SFftAKI
-...a.
tiuc i hAniwn r-rtupi PTPn
TIME.OEPARTED . .
JJMDJMQ
*?; VO
AM(
p.m.( *r'"
v:*sc
S.'O o
AMI ) p.m.( *r
A.M.( P.M.( V
A*M.(
p.m^ r .r
CONTAINER INFORMATIONS
- -- -
End Tlmer
UNLOADING
4-Mj i P.M.( ) .t " A-Mi ) P.M4 )
EndlnflMlles
AMi 1 9Mi ) V'r;' A.M* ) P.M.< ) Total Miles:
Manifest#.
Number Size
Type> Exchange Net Quantity Remarks
ity. '
t `
- - -t sS? -- eRu._. . -tSYfl
- .7C. Ji*rs-L* ; . --^aa>S^sr-'v-STv. 2^ ^
. ; r VT'
7% -T-sAn5T.
t ./*
..* -
. - vr ;t. r_; \
DISPOSAL SITE.
SF-.-
ACCT. #
TYPE OF WASTE.
T *
LOC. CODE:. 100
- -aJ- r''' '-"1- :v - i-.rr.-vuu.-.r- --rvAt^jrAA^ctl^j ,w.i
-------1 . - ......- ...........................
SWRf/Asbestos 3728
AUTO/MANUAL:
'v-.i rrfrprrv:
SYS CODE: i
0101200.1
RTE 120
NBR OF HAULS: 01
CONT SIZE:
VOL" CODE: Yd
COMP:N
( ` )r DELIVERY CHG: (15) INSURANCE CHG: ( ) WAIT TIME
( ) FREIGHT CHG:
(14) FUEL CHG:--fe
PvaaE.-g^iar.fflnaaagraag
,r ( ) CONT. LINER_OHGy
wrr *
. ,, - -".T. ; ' - ...
(24) CQNT. RENTAL
w
(23) TRACK RENTAL
'( ) OTHER CHG:_
TOTAL WAYBILL CHG: