Document 7R20jMdr7q8o7BL3ZvOjYLv0e

Heating Systems {"0^ Johns-Manville Executive offices: 22 East 40th Street, New York 16, N. Y. Offices in All Large Cities TRANSITE AIR DUCT for modern perimeter heating and air-conditioning systems Transite Air Duct is developed by Johns* Manville specially for use in today's basementless homes built on poured concrete slabs. Its strong, durable, as bestos-cement structure makes it a closely related companion to the ma terial of the slab itself. Service Transite Air Duct cannot burn. Completely inorganic, it will not rot or give off odors. It will not crush, dent or deform when concrete is poured. Because of its rigidity, each section of duct will maintain its grade and shape during installation and after. And being non-metallic throughout, a Transite Air Duct system will not rust or scale. Joints Transite Air Duct is quickly and simply joined by Ductite Tape. Sheet metal sleeves and other locally approved jointing methods may also be used. Transite Air Duct is guickly placed in position ready for pouring of concrete... more easily laid to grade. No Encasement Required Transite Air Duct may be laid directly on the pre pared bottom without encasement in concrete, special supports or anchoring. When Ductite Tape is used for assem bly, the joints also need not be encased in concrete. Installation Transite Air Duct is sup plied in standard diameters from 3 in. to 8 in. as shown in table below. Its long 10-ft lengths reduce the number of sections needed with resultant fewer joints. Duct is more easily laid to grade. Its relatively light weight permits oneman handling of full lengths of more commonly-used sizes. Because of Tran sited strength, it needs no special cau tion in handling--no "babying" on the job. Duct may be quickly field-cut to any length required. Transite Warm Air Duct Fittings may be supplied factory-assembled. (One of many such fittings is shown above!) Or they may be furnished in segments for field assembly with Ductile tape. {The segmentsfor atypical fitting are shown below.) Complete Line of Fittings Transite Air Duct is adaptable to any piping layout. A large line of Transite Fittings includes all the couplings, tees, elbows, etc. needed to provide an all-Transite duct system. Transite Air Duct is one of J-M's Transite "pipes for the home," each designed for a specific service. For com plete information, write Johns-Manville. Standard Sizes* Pipe Diameter (in inches) 3 4 5 6 7 8 Weight per loot (in pounds) 2.4 3.4 4.8 5.8 6.8 7.8 ___ Standard Lengths 10 ft and 5 ft If diameters of 10 in. and 12 in. required, Tran* site Pipe is available in 13 ft and 6^3 ft lengths. Heating Systems Direct Fired and Steam Unit Heaters and Convectors Airtherm Manufacturing Company 728 S. Spring Ave. St Louis 10, Mo. Representatives in Principal Cities For Heating Satisfaction--Think first of AIRTHERM AIRTHERM Air Conditioning Unit Remote type using hot or chilled water, from to 2 ton cooling capacity. Write for Catalog 200. AIRTHERM Cabinet Unit Heater AIRTHERM Propeller Fan Unit CABINET UNITS cover every applica tion, capacities from 32,000 to 125,000 Btu per hour. Write for Catalog 1401. PROPELLER FAN UNITS: Horizontal models are produced in capacities from 18.000 to 270,000 Btu. Vertical models 32.000 to 350,000 Btu per hour. Write for Catalog 1209 A. AIRTHERM Gas or Oil Fired Space Heaters Complete heating and ventilating unit, with heavy duty stainless steel combus tion chamber. Capacities from 400,000 to 2,000,000 Btu per hour. Write for Catalog 804. AIRTHERM Convectors Airtherm Convectors are produced in full range of types and sizes. Write for Catalog 70S. AIRTHERM Centrifugal Fan Unit Heaters AIRTHERM Gas Fired Unit Heaters Compact, suspended, propeller fan units available from 25,000 Btu to 200,000 Btu. Write for Catalog 500. For all types of heating and ventilating installations. Available with dampers, filters and non-freeze coils. Capacities up to 1,440,000 Btu per hour. Write for Catalog 40S. 343