Document 7Ox2Q04X6gz27qkk4EZ3YL4MB
INDEX
HEATING VENTILATING AIR CONDITIONING
GUIDE 1954
Technical Data Section Chapters 1"52 and Pages 1-1128
A
Abatement air pollution, 151, 154 smoke, 8, 155, 326
-Abbreviations, 11
Absolute humidity, 5
pressure, 7 temperature, 9, 30 aero, 1, 30
Absorbents, 861, 866 equipment, 867
process, 866 temperature, pressure,
centration, 866
con
Absorbers, 769 duct, sound, 914
outlet, 919 plate cells, 917 plenum, 919 Absorption systems, 839 Acceleration, 1 Acclimatisation, 118 Acoustics, 905 Activated alumina, 862 Activated carbon, 148, 1054
Activated bauxite, 863 Adiabatic, 1
mixing
two air streams, 57 saturation, 60
Adsorbents, 769, 861. equipment, 865
process, 863 temperature, pressure, con
centration, 861
Adsorption, odor, vapor, 156,
762 Aerosol, 1, 134, 151
Air change measurement, 1111 change method, 222, 256 chemical vitiation of, 111,
152,156 circulation, 112, 451, 461, 653,
697, 1052
circulation in dry, 1042 classification of impurities,
151, 752 dust, 151, 752
lint, 151, 752 cleaner, 151, 751, 1052
viscous impingement type, 753
cleaning, 751 cleaning devices, 751, 769, 770
charged media. 756 classification of, 751 electrostatic, 768 installation, 760 maintenance, 759 performance, 757 safety requirements, 761
selection, 759, 763 testing, 757 vapor adsorption, 762 combustion, 347, 348
conditioning process, 653, 977
Air {continued) contaminants, 111, 151, 164, 752, 1003, 1116 cooled condensers, 848 coolers, 597, 601 cooling, tropics, 136 current measurement, 1110 dehumidification, 861 distribution, 451, 461, 667, 669, 1052, 1058, 1061, 1096 air entrainment, 679 application of methods, 693, 1052 balancing.the system, 688 ceiling outlets, 685 definitions, 667 design methods, 715 directional control, 690 duct approaches to outlets, 453, 689 entrainment ratios, 679 flow patterns, 689 friction chart, 698, 699 furnace systems, 451, 461 guide vanes, 462, 482 ' jet pattern, 681 long slot, discharge from, 677 noise level, 683 outlet location, 462, 463, 686, 692 outlet performance, 681, 687 outlets, 670, 684 perforated panels, 677 principles, 669 radial jets, 676 railway car, 1052 recommended velocity, 462, 714 return and exhaust intakes, 692 922 return 'grille, 451, 453, 922
room air motion, 669, 683 selection, 686 smudging, 684 spread, 668, 670
standards for, 668 throw, 675, 681 vanes, 681, 682 velocity, 577, 671, 714 velocity across jets, 672,
673, 675 velocity profiles, 675 vertical drop and rise, 682 volume control, 689, 691 wall outlets, 462, 684 duct construction, 722, 1015 duct design, 464, 697, 713,
724, 1010 duct friction loss, 697 dust concentrations, 155, 160,
161 excess, 330, 344, 348, 377 filter, 753, 760 flow measurement, 78, 1105 flow resistance of coils, 811 impurities, 113,151, 752
infiltration, 217
causes of, 218 due to wind pressure, 218
through walls, 218
leakage, 217-222
moist, 25 '
XI
Air {continued) motion, 122
movement, influence of, 117 movement, measurement of,
1105, 1109 outdoor, 112, 653 physical impurities in, 113,
151, 155, 752 pollution, 151, 155
abatement, 155, 326, 1003 primary, 328,`344
quantity required, 112, 347, 348, 1053, 1055
refrigeration cycle, 836 room motion, 669, 683 saturated, 1
secondary, 328, 344, 377 space conductance, 170, 180 standard, 1 sterilization of, 132, 142 supply and return openings,
452, 463, 684, 692 supply opening noise, 683,
919 temperature requirements,
122, 126, 247, 266, 978, 988, 1061 theoretical requirements, 112, 346, 348, 1062 thermodynamics of, 23 unit cleaning devices, 751, 773 washers, 1, 773 Air change method computing infiltration, 220, 255
Air conditioning, 1
aircraft. 1057 automobiles in summer,-1057 central system, 653, 1093 comfort, 2 hospitals, 131-148 humidity, table, 978 industrial, 977
atmospheric conditions re quired, 267, 978-988
calculations, 993 general requirements, 977 problem classification, 977 typical applications, 977 owning and operating cost,
967 passenger bus, 1056 processes, 54
adiabatic mixing , 57 adiabatic saturation, 60 cooling, 55 heating, 54 v railway passenger car, 1051 residential, 1091 ship, 1060 stoker-fired units, 358 storage systems, 841 streetcar, 1055 summer design conditions,
266, 267, 269
temperature table, 266, 269,
978
transportation, 1051
treatment of disease, 131