Document 7OvkYd442j0E9nQ4MVxQyy6No

T E CHNI CAL R E-VI E W * ** ***>'-*>., -**^V\.; ". V VOLUME 2 AUGUST, 1955 NUMBER 2 ANALYSIS AND CONTROL OF HYDRAULIC SURGE The COOK TECHNICAL REVIEW is published at frequent intervals by the Cook Research Laboratories, a division of Cook Electric Company, 2700 N. Southport Avenue, Chicago 14, Illinois, in cooperation with the other company divisions: Air Mod Diaphlex Electronic Systems Inland Testing Laboratories MagniLastic Wirecom W. C. Hasselhorn President John S. Baker Vice President in Charge of Engineering C. E. Lundeen Vice President-Treasurer BertErikson Secretary-Controller EDITORIAL BOARD J. R. Downing, Director, Cook Research Laboratories J. C. Bellamy, Associate Director, Cook Research Laboratories EDITORIAL STAFF Leo G. Killian, Editor Harry R. Thornton, Circulation Manager Price in the United States and Canada $1.00 per copy; in other countries $1.25. Checks should be made payable to Cook Electric Company and addressed to the Circulation Manager. Printed in U. S. A. Copyright 1955 by Cook Electric Company Volume 2 August, 1955 ANALYSIS AND CONTROL OF hydraulic surge Number 2 Howard Moore Project Engineer A Division of COOK ELECTRIC COMPANY 2700 North Southport Avenue Chicago 14, Illinois PREFACE TO SECOND ISSUE In 1954 a few copies of this manual were made up in mimeographed form and distributed as Issue No. 1 to selected organizations and engineers engaged in hydraulics and related fields. Since that time additional tests have been conducted, data analyzed, and studies implemented. These investigations were primarily con cerned with a determination of the relationship of n (the polytropic exponent of gas expansion) with respect to duration of the surge cycle, a theoretical approach to and development of formulas related to the hydraulic energy balance, and the inclusion of some tabular material previously unavailable. The typography has been corrected and the plates prepared in a more legible fashion. A number of comments and suggestions received from users of the manual have been incorpo rated. The critical review undertaken by Messrs. Elmer A. Beck, Jr. and Ralph Weaver, of the Cook Research Laboratories, has been of great value in preparing this revised edition. It is hoped that this volume will resolve the current divergencies in water ham mer and surge analysis and will provide a convenient reference for pertinent data previously obtainable only from a number of separate sources. Chicago, Illinois August, 1955 Howard Moore . v PREFACE TO FIRST ISSUE This manual has been prepared for the practicing engineer who, always pressed or me, oxpe itious and logical explanations for surge phenomena, univer sally applicable formulas expressed in common engineering units, and methods of surge analysis formulated for rapid use. To achieve the goals of usability and sim p icity e mathematics employed have been limited to algebraic derivations from energy concepts and thermodynamics. To further simplify and accelerate the soluon o water ammer and surge control problems, several plots and nomographs ave een prepared. Included in the tabular material are data of sufficient scope to permit the complete surge analysis of most piping systems. is manua covers the fields of water hammer, surge suppressing devices, surge con o wi pneumatic suppressors, pulsation control and resonance, accumula tors, and thermal expansion compensation. The assistance and encouragement received from various individuals and or ganizations who supplied information and advice during the preparation of this manual is gratefully acknowledged. In particular, a word of appreciation is in order to the Pelton Water Wheel Company, McGraw-Hill Book Company, and u t /\TMer*can Society of Mechanical Engineers for permission to reproduce pub lished figures and drawings. Staff members of the Cook Electric Company and the Cook Research Laboratories who aided materially in the preparation and finaliza tion of the manual are Messrs. Harry R. Thornton, advertising manager, Glen Juergensen, chief engineer, MagniLastic Division, and Leo G. Killian, Director of Technical Publications, Cook Research Laboratories. The interest of Messrs. Walter C. Hasselhorn, President of Cook Electric Company, and Robert L. Sigwell, Manager of its MagniLastic Division, has greatly benefitted the surge inves tigations and preparation of this manual. Chicago, Illinois August, 1954 Howard Moore vi CONTENTS Page Preface to Second Issue........................................................................................ v Preface to First Issue..................................................................................................vi Symbols................................................................................................................ x Definitions.................................................................................................................... xii Introduction Historical Background of Water Hammer Studies...................................................1 Classification of Water Hammer............................................................................... 1 Scope of Available Literature.................................................................................... 1 Need for Empirical Data.............................................................................................. 1 Range of Tests Conducted......................................................................................... 1 Part I--The Phenomena of Water Hammer The Case of Rapid Fluid Deceleration..................................................................... 4 Sequence of Physical Events............................................................................... 4 Elastic Properties of the Fluid and Conduit....................................................... 6 Nature and Velocity of the Pressure Wave............................................................ 7 Pressure-Velocity Relationship............................................................................... 9 Pressure-Excess Volume Relationship.................................................................9 Effective Velocity in Complex Conduits.................................................................9 The Case of Slow Fluid Deceleration......................................................................9 The Time Parameter, N......................................................................................... 9 Pressure-Velocity Relationship............................................................................. 11 Allievi's Theory of Water Hammer.................................................................... 11 Surge Wave Shape for T>/t.................................................................................. 15 Effective Velocity of Pressure Wave....................................................................15 Part II--Surge Suppressing Devices By-Pass Type Suppressors....................................................................................... 16 Relief Valve........................................................................................................... 16 Automatic Surge Suppressor.............................................................................. 16 Storage Type Suppressors........................................................................................17 Surge Tanks........................................................................................................... 17 Air Chambers.......................................................................................................17 Gas-Liquid Separating Media..........................................................................17 Piston-Type Suppressors....................................................................................... 18 Bladder-Type Suppressors...................................................................................18' Diaphragm-Type Suppressors..............................................................................19 Sleeve-Type Suppressors................................................................................... 19 Pneumatic Bellows-Type Suppressor................................................................ 20 Evaluation of Storage-Type Suppressors...................................................... 22 vii Part III__ Surge Control With Pneumatic Suppressors Page Effect of Suppressors................................................................................................. ^ The Energy Balance............................................................................................. Complex Systems.................................................................................................. Orifice Filling Control ............................................................................................ 27 Series Systems...................................................................................................... 20 Effect of Check Valves on Surge Characteristics............................................ 31 Suppressor Placement.............................................................................................31 Uphill Pumping Systems........................................................................................31 Pulsation Control in Reciprocating Pump Lines..................................................... 25 Resonance.....................................................................................................................26 Accumulators................................................................................................................27 Thermal Expansion Compensation.........................................................................28 Hydraulic Energy Balance....................................................................................... 29 Table I. Conversion Factors and Formulas......................................................^ Table II. Viscosity Conversion Factors........................................................... ^0 Table III. Properties of Liquids.......................................................................... Table IV. Properties of Conduit Materials...........................................................^ Table V. Pipe Dimensions............................................................................... Table VI. Logarithms........................................................................................ Bibliography................................................................................................................ ^ vni illustrations Co N> to to Plate I. Pump and Engine Assemblies . . . .................... Plate II. 500-Foot Pipeline Loops .... .. Plate III. Controlled Closing Plug Valve ... ... Plate IV. Suppressor Filling Control Orifice Plates ......................... .... Fig. la, lb. Schematic Representation of Water Hammer Cycle ... Fig. 2. Simultaneous Pressure-Time Records of Water Hammer (Theoretical) Fig. 3. Simultaneous Pressure-Time Records of Water Hammer (Actual) . Fig. 4. Nomograph for a.................................. Fig. 5. Nomograph for Pipe Line Parameter K ............................................. Fig. 6. Nomograph for Time Parameter N . ............................................ Fig. 7. Chart for the Determination of Pressure Ratio ....................................................... .... ' Fig. 8. Allievi Chart--Pressure Rise for Uniform Gates and Simple Conduits. Small K and Fig. 9. Fig. 10. Allievi Chart--Pressure Rise for Uniform Gates and Simple Conduits. Large K and N Simultaneous Pressure-Time Records for Slow Closure.................................................. Fig. 11. Relief Valve at Shutoff Valve; . . Fig. 12. Relief Valve in Pump Discharge Line Fig. 13. Automatic Surge Suppressor . . . Fig. 14. Surge Tank Installation................... Fig. 15. Air Chamber.................................. Fig. 16. Floating Piston Type Suppressor . Fig. 17. Bladder Type Suppressor .... Fig. 18. Diaphragm Type Suppressor . . . Fig. 19. Sleeve Type Suppressor.................... Fig. 20. Nonpressurized Hydropad .... Fig. 21. Pressurized Hydropad................... Fig. 22. Pressurized Hydropad with Bellows Extended.................................................. Fig. 23. Stainless Steel-Trimmed MagniLastic Hydropad............................................. Fig. 24. 55,006 Cubic-Inch Hydropad............................................................................... Plate V Hydropad Installation, San Pedro, California.................................................. Fig. 25. Simultaneous Pressure-Time Records for a System Incorporating Suppressors Fig. 26. vs. Capacity Factors................................................................................... Page .5 .5 .8 . 10 . 12 . 13 14 14 15 16 16 16 17 17 18 19 19 19 20 20 20 21 21 21 22 24 Fig. 27. Vo p,,,* VS. 26 - Fig. 28. Fig. 29. Fig. 30. Fig. 31a. Pm` y PoQ Pressure-Time Records for a System Incorporating Suppressors and Orifice Filling Control. System Diagrams and Superimposed Pressure-Time Records................................................. Flow, Pressure, and Pump Speed Curves for Power Failure in Uphill 27 29 31 Fig. 31b. Pumping System Without Check Valve.................................................................................... 32 Flow, Pressure, and Pump Speed Curves for Power Failure in Two Fig. 32. Uphill Pumping Systems Incorporating Check Valves........................................................... 32 Relation Between Friction Factor and Reynolds' Number for Flow in Fig. 33. Fig. 34. Fig. 35. Fig. 36. Circular Pipes, With Added S Number Coordinates................................................................ Nomograph for Kinetic Energy per Unit Length..................................................................... Nomograph for Elastic Energy per Unit Length..................................................................... Bulk Modulus of Hydrocarbons....................................................................................' . . . Bulk Modulus and Specific Weight of Water.......................................................................... 33 40 41 42 43 ix Symbol A a ae a, b C Co Co c,,, c,. CjD d dx d'2 E e F Fi f g Ho H,, h b Mfi i hr h,,. K k L Lx L-, U M Mi N N,, Ni n Ml P P Pi P P' P Pt P,,, Pm Pmu.T SYMBOLS Unit Description sqft Flow area of pipe fps Velocity of pressure wave fps Effective velocity of pressure wave fps Velocity of pressure wave at temperature t\ in. Bore of reciprocating pump cylinder -- Coefficient of orifice discharge cu ft j Capacity of suppressor: volume occupied by cu in. \gas at initial charging pressure p, cu ft Volume occupied by gas within suppressor at pressure pm cu ft j Volume occupied by gas within suppressor cu in. |at pressure ft Inside diameter of pipe in. Inside diameter of pipe in. Expanded internal diameter of pipe in. Orifice diameter psi Modulus of elasticity (Young's) of pipe material in. Thickness of pipe wall lb Force - Reciprocating pump volumetric factor -- Pipe friction factor ft/sec2 Acceleration due to gravity ft Pressure head for steady conditions ft Static head ft Pressure rise above normal at any time ft Maximum pressure rise ft Pressure rise for instantaneous closure hr = av0/g inches of water Differential pressure across orifice -- Pipe line parameter = av0/2gH,, psi Bulk (volume) modulus of liquid ft Length of any uniform section of pipe ft Distance between valve and suppressor ft Resonant length of "closed end" pipe ft Resonant length of "open end" pipe - Any integer -- Any odd integer -- Number of time intervals = aT/2L -- Reynolds' number -- Number of time intervals = aT/2Li -- Polytropic exponent of expansion of a gas cps Frequency of pulsations psfg Unit pressure psfg Initial pressure psfg Maximum pressure psig Unit pressure psf per ft Pressure gradient . psia Atmospheric pressure psi Pressure drop in conduit during steady flowing conditions Psig Maximum allowable surge pressure psia Maximum allowable surge pressure, absolute = p,,, + p,, psi Pi-Po X Symbol Unit Description Vo PSlg Po psia Vp psig Vr psi V. psig V' psig V** psia Pi psig Pi psia P-> psig Vs psig S-- s psi Initial gauge pressure Initial absolute pressure = pn + Pump discharge pressure Pressure rise Static or elevation pressure Reduced pressure Reduced pressure, absolute ~pT + pa Maximum water hammer pressure, or locked up pressure at temperature 11 Pl + Pa Pressure at orifice inlet when full flow is established Minimum pressure at instant of flow reversal Johnson's parameter, equations (44) or (45) Hoop stress Sl in. T sec Tr sec t sec to F <1 F V cu ft Piston stroke of reciprocating pump Time of valve closure Time after valve closure Time Initial temperature Final temperature Volume Ve cu ft Expanded volume of conduit v. cu ft Volume of liquid entering suppressor cu in. Volume of displaced fluid Vi. cu ft Expanded volume of liquid v,, cu ft Initial volume Vp V: V, Vu V-, c w,. cu ft cu ft fps fps fps ft-lb Excess volume stored in pipe Final volume Instantaneous velocity of liquid . Effective velocity of liquid Velocity of liquid under initial steady-state conditions Elastic energy stored in compressed liquid WL' ft-lb/ft Elastic energy stored in compressed liquid per unit length . Wo, w,,w2 ft-lb Kinetic energy w,,' ft-lb/ft Kinetic energy per unit length W, ft-lb Elastic energy stored in stretched pipe W/ ft-lb/ft Elastic energy stored in stretched pipe per unit length w ft-lb Elastic energy stored in stretched pipe and compressed liquid Ws' ft-lb/ft Elastic energy stored in stretched pipe and compressed liquid per unit length w lb/cu ft Specific weight of liquid Wtt Ib/cu ft Specific weight of liquid at base temperature t,, wt lb/cu ft Specific weight of liquid at temperature t, Y-- z- - Pressure ratio factor: equation (37) Ratio of total water hammer pressure to initial pressure = p,/p,, a ft-lb Potential energy stored in suppressor p V> Vr -- ft-lb Orifice ratio d2/d Potential energy or flow work of liquid entering suppressor 8; 8j, 2 ft-lb Elasic energy stored in stretched pipe and compressed liquid S' ft-lb/ft Elastic energy stored per unit length *C in./in.-F Coefficient of linear expansion (conduits) EL cu in./cu. in.-F Coefficient of cubical expansion (liquids) A ft Wave length p sec Period of pipe = 2L/a xi Symbol p, jx.j, ' p Unit slugs/ft-sec centipoise centistokes slugs/cu ft Description Dynamic viscosity Dynamic viscosity Kinematic viscosity Mass density of liquid = w/g DEFINITIONS For purposes of this manual, the following definitions are used: Pressure SURGES are water hammer phenomena caused by liquid deceleration or unsteady flow. The CAPACITY of a surge suppressor is the volume occupied by the pressurizing gas at the initial charging pressure. xu INTRODUCTION Historical Background of Water Hammer Studies ' The first significant treatises on the phenomenon of water hammer were those of Michaud (1878), Joukowsky (1904) and Allievi (1903 and 1913); Michaud (Bibliography: Ref. 1) noting the pres sure oscillations characteristic of water hammer, as affected by the combined elasticities of the conduit walls and confined liquid, regarded this elastic structure as analogous to an air chamber of variable capacity. Joukowsky (Ref. 2) first established the rate of propagation of the pressure wave, a, and de rived the expression for maximum pressure rise in a water conduit, h = av0/g (ft), following closure of discharge valve within the period 2L/a (sec). Allievi (Ref. 3) presented in his Notes I to V and accompanying figures a mathematical analysis and convenient method for determining the maximum pressure rise for uniform valve closures--both rapid and slow--in simple conduits. He also considered the surges resulting from acceleration of flow and resonant conditions in a conduit. In 1933 a symposium on water hammer was held in Chicago under the auspices of the A.S.C.E. Power Division and the A.S.M.E. Hydraulic Division. Ex isting theories were reviewed and compared, cor roborating evidence was presented from test data, and a comprehensive bibliography was compiled. In the publication of these papers (Ref. 4), an ex cellent background was provided for the analysis of water hammer. Worthy of note is the high esteem which the A.S.M.E. Committee on Water Hammer had for the analyses of Allievi. Referring to his Theory of Water Hammer (Ref. 3), the statement is made: "This treatise was translated in many lan guages and forms the basis for virtually all of our theory of water hammer." Classification of Water Hammer In the Symposium (Ref. 4) the A.S.M.E. Com mittee on Water Hammer defined five basic condi tions for water hammer investigations and analysis: Case I --Conduits of Uniform Thickness and Diameter (Simple Conduits) Case II --Conduits of Variable Thickness and Diameter (Complex Conduits) Case III --Conduits Having Branch Pipes (Com pound Conduits) Case IV --Water Hammer in Pump Discharge Conduits (Power Failure of Centrif ugal Pump in an Uphill Pumping System) Case V --Surge Tanks (Stand Pipes Open to the Atmosphere) To these may be added the following conditions: Case VI --Pulsation in Reciprocating Pump Dis charge lines Case VII --Surge Control by Relief and BypassType Suppressors Case VIII--Surge Control by Pneumatic Surge Suppressors Scope of Available Literature Cases I through V are adequately analyzed in the papers and references cited in Symposium on Water Hammer (Ref. 4). Additional recommended mate rial is listed in the Bibliography Page 54. It is chiefly with Cases VI through VIII that the present Manual is concerned. A survey of all available literature re vealed a surprising misconception and misapplica tion of the basic principles on the part of many authors. The range of analyses and sizing formulas pertinent to Case VIII in particular, produced such a scattering of results from given data as to be wholly unacceptable. Needfor Empirical Data ' It was desirable that a comprehensive series of full-scale tests be conducted, employing flow and pressure recording instrumentation of high accuracy and negligible inertia. From the records so obtained, the correct application of physical principles, the adequacy of methods and formulas, and the values of certain basic constants could be determined. . Range of Tests Conducted In order to examine as many variables as possible in the investigation of surge phenomena, it was nec essary to set up a liquid transferring system wherein line length, flow velocity, deceleration rate, and pres sure of the flowing liquid could be held constant or varied individually over a sufficiently wide range to insure obtaining definitive data. If the four inde pendent variables--pipeline length, fluid velocity, valve closing time, and fluid head--could be con trolled at will, it would be possible to produce any II] desired values of the basic water hammer parameters K and N. A hydrant refueling system for aircraft was used in the surge investigation. The following components were used from this system: pump and engine as semblies, check valve, gate valves, tubing and fit tings, grooved-type couplings with gaskets, pressure regulating valve, and surge suppressors. Additional suppressors, furnished by various manu facturers, provided a total suppressor capacity of nearly 7,000 cubic inches. Components for measuring and controlling the fluid flow were added to the basic system. A flow section consisting of a 20-foot length of 6-inch steel pipe fitted with a pair of 6-inch, 300-pound, orifice flanges was used with square-edged orifice plates to Plate I--Pump and Engine Assemblies Two of the skid-mounted pump and engine assem blies (Plate I), each equipped with a Marlow Model 6G2 self-priming centrifugal pump driven by a Con tinental Model T-427 engine, were connected in series. Depending upon engine speed, the units sup plied fluid at flow rates of from 0 to 620 gpm at pres sures up to 150 psi. A 6-inch Powell horizontal swing check valve with a cast iron body was used for some of the tests at the discharge of the second-stage pump. Gate valves used were line size (6-inch or 4-inch) with cast aluminum bodies and bronze trim. The valves were manufactured by the Milwaukee Valve Company and conformed to their Fig. P-2654 except that the ends were grooved for couplings. The pipe line for the test system was laid out in long loops (Plate II). The lengths of 6-inch alumi num tubing and malleable iron fittings used for the pipeline conformed with Specifications MIL-T-10794 and MIL-P-10388, respectively. The malleable iron couplings, complete with synthetic rubber gaskets, conformed with Specification MIL-C-10387. The 6-inch pressure regulating valve was a Cla-Val No. 90-AF-2 with an aluminum body and having an ad justable discharge pressure range of from 40 to 60 psi. Eight surge suppressors from the portable sys tem were available. These suppressors were the Cook Electric Company's Model HJ-350 with a pressurizing gas capacity of 200 cubic inches each. [2] Plate II--500-Foot Pipeline Loops measure and record flow rates. Three calibrated orifice plates constructed of stainless steel, and hav ing bores of 3.750,4.500 and 4.750 inches, were used. The orifice plates were calibrated using water as the test fluid. Variable speed shutoff of the flow of fluid in the system was provided by a 3-inch Nordstrom plug valve (Plate III) actuated by an air cylinder whose closing time could be regulated by an air con trol valve. Flow control was furnished by a 6-inch Grove Flex-Flo valve whose jacket pressure was re motely controlled by a Grove Loader supplied with compressed air. Plate III--Controlled Closing Plug Valve Square-edged orifice plates for suppressor filling control (Plate IV) having bores ranging from 0.45 inches to 1.80 inches were inserted in a pair of 6-inch orifice flanges located between the suppressors and the main flow line. Plate IV--Suppressor Filling Control Orifice Plates Pressures were sensed by two Statham transduc ers, one having a range of 0--300 psig and the other a range of 0--500 psig. The output of each pickup was fed to a Brush amplifier and continuously recorded by a 2-channel Brush oscillograph. For some tests where synchronization of transient measurements was not required, a Bristol pressure recorder Was employed in addition to the Statham-Brush combi nation. In some tests indicator gauges were placed at various locations in the system for visual observa tion of pressures. Flows at the orifice were recorded by a Bristol differential pressure recorder. The time record of the temperature of the nitrogen gas pressurizing a surge suppressor was obtained by the insertion of an iron-constantan thermocouple into the gas chamber and the continuous recording of the output voltage by means of a Bristol Dynamaster temperature re corder. Specific gravity and temperature of the test fluid were determined with a laboratory hydrometer and a thermometer. For some tests additional pressure measuring and recording equipment was available. This instrumen tation consisted of four Statham pressure transduc ers, four Brush amplifiers, and two 2-channel Brush oscillographs. During test runs for which this addi tional equipment was available, six pressures at six locations in the test system could be recorded si multaneously. To indicate the closing time of the Nordstrom valve on the Brush pressure record charts, the circuit controlling the event-marker pen was energized by the voltage supplied to the small solenoid pilot which operated the air cylinder attached to the Nordstrom valve. At the instant of complete closure the eventmarker pen circuit was momentarily de-energized by the action of a secondary circuit containing switch contacts located on the stem and body of the Nord strom valve. Calibration of the transducers and recording equipment by means of a dead-weight tester was performed at the beginning of every series of test runs and at intervals between runs in the series. An over-all accuracy of 2% in pressure, measurement and 3% in flow measurement.could be reasonably expected from this instrumentation. The tests were made using either water or Grade JP-4 jet engine fuel with a specific gravity of 0.815, as required by the objective of a particular test. Among the conditions studied by means of the test setup, the following are pertinent to the present study: Measurement of water hammer phenomena Reduction of surge pressures by suppressors lo cated at the shutoff valve ' Reduction of surge pressure by suppressors lo- . . cated at various distances from the valve Surge reduction by suppressors located at the valve and having orifice filling control The influence of a check valve on the resonance of a system Heat transfer characteristics of various pneumatic suppressors during energy absorption. [3] PART I--THE PHENOMENA OF WATER HAMMER The Case of Rapid Fluid Deceleration Sequence of Physical Events The physical concepts of the water hammer cycle can be most clearly illustrated by consideration of the simple conduit, supply reservoir, and shutoff valve illustrated in Fig. la and lb. Diagram (1) converted into elastic energy stored in the stretched pipe, per unit length, AuPWd ft-lb 288eE and in the compressed fluid, per unit length, A to2 hr ft-lb 288k -RESERVOIR PRESSURE GRADIENT VALVE PIPE NORMAL DIAMETER liquid normal density PIPE STRETCHED LIQUID COMPRESSED VALVE (2.)DIRECT BLOW FOLLOWING VALVE CLOSURE. Tc= L/Zo 14) REFLECTED WAVE TRAVELS TOWARD VALVE. Tc = 3L/Zo SYMBOLS V = FLUID VELOCITY h= PRESSURE RISE V0= INITIAL FLUID VELOCITY Tcs TIME AFTER VALVE CLOSURE a = VELOCITY OF PRESSURE WAVE L=LENGTH INITIAL FLUID PRESSURE > FRONT AND DIRECTION OF PRESSURE WAVE (5.) REFLECTED WAVE REACHES VALVE. Tc=2L/o PIPE SHRUNK 1 LH.-h HoJI LIQUID INCREMENT EMPTIED UPSTREAM "Vs-Vo- --L/2-- A . n-- i iV5L/20 (6J SUBNORMAL PRESSURE WAVE TRAVELS TOWARD RcEaScEnRvVuOmIR. /r-PLI|PQEU1DSH,RNUCNRKMENT rHo"h / EMPTIED INTO RESERVOIR U---------------- v = o----------- Tc=3L/a (?.) SUBNORMAL PRESSURE WAVE REACHES RESERVOIR\ ^SECTION OF PIPE SHRUNK -------- Lwr. L/2- - Tc=7L/2a IS) LIQUID RE-ENTERS PIPE FROM RESERVOIR. PIPE NORMAL DIAMETER LIQUID NORMAL DENSITY' TC=4L/a !9.)LIQUID REFILLS PIPE, COMPLETING CYCLE. Fig. la. Schematic Representation of Water Hammer Cycle shows the steady state conditions existing before valve closure. The fluid is flowing from left to right at an inital, constant velocity, tv Because of friction losses, pressure in the conduit diminishes uniformly from reservoir to valve, where its value is H0. Now let the valve be closed completely and instantane ously. The mass of fluid immediately adjacent to the valve has had its velocity, o, reduced from v,, to 0, and its kinetic energy, per unit length. (w/2g)Av0~ ft-lb [4] Fig. lb. Schematic Representation of Water Hammer Cycle While the fluid in the conduit upstream from the region of compression continues to flow in the initial direction and at the initial velocity, o0> the front of this region of compression travels very rapidly toward the reservoir. Its speed of propagation, desig nated as the "velocity of the pressure wave," is rep resented by the constant a. Conditions existing at the time when the pressure wave has travelled upstream half the distance to the reservoir, during the time following valve closure, T,.= L/2A, are depicted in Diagram (2). Fluid in the upstream section is still flowing with the initial ve locity, t50, and at the initial pressure, H0. All fluid in the downstream section is at rest and at a pressure of H,, + h. At the time L/a, the region of compression will reach the reservoir. As shown in Diagram (3), the entire column of liquid is at rest and under a pressure of H,, + h. It should be noted that the value of H0 is variable between the reservoir and valve, depending upon the friction losses when v = v0. The pressure rise, h (in feet of fluid), is constant from energy con siderations, but algebraic addition of H0 and h will produce the sloping pressure gradient shown in Diagram (3). Because of the excess pressure h in the conduit, the adjacent fluid empties into the reservoir, the energy stored in the stretched pipe and compressed fluid being reconverted into kine-ic energy to pro duce a velocity equal to vQ, but in the opposite di rection. The zone in which this reconversion of en ergy takes place starts at the reservoir and travels toward the valve with the constant velocity a. Dia gram (4) illustrates conditions when this reflected wave has travelled half the distance to the valve. Fluid in the upstream section is flowing at velocity -- v,i into the reservoir at the initial pressure, H0. Fluid in the downstream section is at rest and sub jected to a pressure of Ho + ft. When all the stored energy has been reconverted and the reflected wave has reached the valve, the conditions are those depicted in Diagram (5), at Tr = 2L/a. All the fluid is at the initial density and is moving toward the reservoir at constant velocity -- the pressure in the conduit is Ho- As flow continues toward the reservoir, Diagram (6) , the quantity of fluid leaving the downstream section of the pipe is sufficient to result in a pressure reduction of -- ft. The fluid remaining, having im parted its total kinetic energy to the upstream fluid column, comes to rest. At time Tc = SL/a, die whole column is at zero velocity, as illustrated in Diagram (7) . Line pressure at this instant is theoretically H,, -- ft, but in actual practice H0~h can never be less than the vapor pressure of the liquid. Unbalanced pressures at the reservoir now restore the flow to o0 in the original direction and at the original pressure, H0, as shown in Diagram (8). The region of transition, where the head of the moving column of fluid enters the section of pipe which has been at reduced pressure, travels at the velocity, a. When this region reaches the valve, at time TC=4L/a, as shown in Diagram (9), conditions are identical to those existing at the instant of valve closure, Tc = 0. All the fluid is flowing toward the valve at die initial velocity, v,,, and pressure, H,,. The cycle, completed in 4L/a seconds, is now repeated at the same rate but with diminishing intensity until damped out by pipe friction and the limitation that (H0 -- ft) must be at least equal to the vapor pres sure of the liquid. The square-topped pressure-time wave pattern, characteristic of the water hammer cycle, is illus- Fig. 2. Simultaneous Pressure-Time Records of Water Ham mer (Theoretical) trated in Fig. 2. Here theoretical pressure-time meas urements are presented for three locations in the pipeline: at the valve, at the mid-point, and at the reservoir outlet. Note the sloping gradient resulting from recovered friction head. Tracings of electron ically recorded pressure-time measurements made under controlled conditions on a test sys'tem contain ing 3078 feet of 6-inch aluminum tubing and han dling JP-4 jet engine fuel at an initial flow rate of 655 gpm are reproduced in Fig. 3. Pressure pickups were located at the shutoff valve, at the mid-point in the piping system, and at the outlet of the centrifugal Fig. 3. Simultaneous Pressure.Time Records of Water Ham mer (Actual) 15] pump which served as the reservoir. Some minor pressure reflections will be noted, as well as a drop in the pressure curve just before the maximum value is reached. These irregularities may be partially ex plained by the configuration of the system, which was laid out in long loops of 500 feet or more, and the presence of the valves and fittings required to control the total effective line length by permitting flow through selected loops. Although the initial pressure rise at the valve, pr( =wh/144), was 240 psi, the subsequent value of initial pressure reduc tion (theoretically equal to--pr) was only 30 psi, and Ho -- h never dropped below atmospheric pres sure. The true vapor pressure of JP-4 at the temper ature recorded during the run was approximately 2 psia. Elastic Properties of the Fluid and Conduit Although regarded as incompressible in the anal ysis of steady flow problems in fluid mechanics, all liquids are compressible. It is the compressibility of the liquid which, combined with the elasticity of the conduit walls, directly determines the pressure rise resulting from converted energy, and the velocity of propagation of the pressure wave, a. Defined as the reciprocal of compressibility, the bulk modulus, or modulus of volume elasticity, _ Pi-Po v0-v1 psi (1) Vo where p,, and p i are the initial and final pressures, psi, and V0 and Va are the corresponding volumes, in any convenient unit. The bulk modulus of water is 280,000 psi at 32F (See Fig. 36). The physical significance of Formula (1) is that for each psi of applied pressure the con fined volume of water at 32 is reduced by 1 . 280,000 Were it not for the fact that the bulk modulus of a liquid increases with an increase of pressure (at 2500 atmospheres the bulk modulus of water at 32F is 567,000 psi), it might be logical to assume that when a pressure equal to the bulk modulus was reached, the volume, Vi, occupied by the liquid would have been reduced to zero. The energy stored by elastic compression of the liquid is the volume change times the average value of the pressure change producing the new volume, or WL= 144(V0 --V2)-(Pl^ -g?) ft-lb (2) where V0 and Vi are initial and final volumes in cubic feet and pn and pt are corresponding pressures [6] in. psi. From Equation (1) a value of V Vi is ob tained: Vv,, - Vv, - k (la) Substitution into Equation (2) yields 72Vo(pi-Po)f ft.lb Lk (3) For unit length the expression becomes 72A(pj_zo)f. ft-lb/ft Lk (3a) where A is the flow area of the conduit in square feet. The elasticity of the pipe is expressed in the con cept and value of Young's modulus of elasticity, de fined as the ratio of stress to strain, or E=df=d psi (4) d where E = Young's modulus, psi s = hoop stress, psi d = initial pipe diameter, inches d-[ -- expanded pipe diameter, inches Inside diameters may be used without significantly affecting the accuracy of calculations. For a pipe the increment of- stress, ds, resulting from an internal pressure rise from p0 to Pi, is &=(p,-p_o)d ps. (5) where e is the pipe wall thickness, inches. The' energy stored in the stretched pipe walls is expressed by the product of the volumetric change and the average value of the pressure change, or W, = 144( V, -V0)(Pl~?u)- ft-lb (6) in which Vi_Vo=isi miPi~Po) cu'ft (7) and L is the length in feet. Substitution and simplifi cation yield Wp = T2ALd{n-p0)* ft]b (g) For unit length W/ = Pu)~ft-lb/ft (8a) The total energy stored by compression of the liquid and expansion- of the pipe walls is Ws = W, + WP = 72AL(p, -p,,)2(j +6|)ft-lb * (9) For unit length: W = 72A(pt-p,,)2(-|+eJ) ft-lb/ft (9a) Nature and Velocity of the Pressure Wave The increment of volume, a thin cross-sectional slice of liquid in which, at any instant, the steady flow within the pipe is undergoing an abrupt change in velocity, is known as the front of the pressure wave. Like any fluid disturbance, this wave front travels with the speed of sound, reflects from branches, dead ends, and changes in section. It travels in either direction with undiminished in tensity. Two pressure waves, starting at the opposite ends of the pipe, will pass through each other with out mutually interfering, and progress until re flected. Pressures in their wakes will be the algebraic sum of the individual pressures. The velocity of propagation, a, of the pressure wave can be derived quite simply from logical rea soning. If liquid is entering a pipe of constant cross section A (square feet) at a constant velocity t>0 (feet per second) and there is no outlet, in t seconds the quantity Avnt (cubic feet) will have occupied the increment of volume created by compression of the fluid and expansion of the pipe walls throughout the length L of the pipe. The rate at which this vol ume is being occupied is obviously L/t, which ratio we shall define as a, the velocity of propagation of the pressure wave. Setting the added volume equal to the space provided by a pressure increase from p,,topt. Avat = AL(pl-p0)^j+ cuft (10) and letting a = T=(--~--1, d | ft/sec (11) * Kp'-pJ\k+eE/ variables can be eliminated by equating the total kinetic energy before valve closure: Wu = ~^- ft-lb (12) where to is the specific weight, lb/cu ft g is the acceleration of gravity: 32.2 ft/sec2 to the total strain energy stored after valve closure: WB=72AL(p,-p,,)2(j+ ft-lb (9) from which 144s (ir+s) (13) (Pi-Po)- w Substitution in (11) readily yields a = --;--------- -------- ft/sec (14) where d = inside diameter of pipe, inches e -- pipe wall thickness, inches Using this value of a. Formula (9) becomes 10,36_8AL(pj_-- p0 )2 a^w For convenience in determining the value of a the nomograph. Fig. 4, has been prepared. An example is provided to illustrate its use. Given data: pipe I.D., d -- 10.020 in. wall thickness, e -- 0.365 in. Young's modulus for pipe material, E = 30,000,000 psi Fluid contained: water, with bulk , modulus k = 294,000 psi specific weight of water, to = 62.4 lb/cu ft Find the ratio d/e ~ 10.020/0.365 = 27.5. Using a straightedge connect 30,000,000 on the E scale with 27.5 on the d/e scale. Mark the intersection on axis (1). Connect this intersection with point (2) and mark the intersection with curve (3). Extend a straight line from point (4) through the last inter cept on curve (3) to intersection with line (5). Con nect this point with 294,000 on the k scale and mark the intercept on line (6). Connect this intercept with point (4) and mark the intersection with curve (7). Extend a straight line from point (8) through the intercept on curve (7) until it intersects line (9). Connect this point with 62.4 on the to scale and read 4160 fps at the intersection with the a scale. An accuracy of zfc %% can be reasonably expected from careful use of this nomograph. The actual calculated value of a for the example just given is 4157 fps, or an error of 0.075%. [7] 18] Fig. 4. Nomograph for A Pressure-Velocity Relationship By combining Equations (13 and (14) and solv ing for the pressure rise, Pl ~Po> the celebrated Law of Joukowsky (Ref. 2) can be expressed in common engineering units: Pl_Po" 144? P$i (15) Derivation of Joukowsky's Law may also be made by applying the momentum relationship expressed in Newton's Second Law. Since impulse Ft equals momentum Mv0 the increased force F caused by fluid deceleration is equal to the time rate of change of momentum: F = d(Mv0)/dt. Because the change in momentum is equal to the rate at which the mass of the fluid is being brought to rest, F = va( dM/dt). The differential of mass, dM, may be thought of as a thin slice, dL feet thick and A square feet in cross section, having a volume AdL cubic feet and a mass of AdLic/g slugs. Since dh/dt = a, the expression may now be written .. (wAdL\ _ v0wAa ,, F-v\-w) ~ lb & Solving for the pressure rise, F* _ p _p _ v,,wa A -Pi-Po---- psf (15a) or, v0wa Pi~Po = 144g psi (15) A convenient nomograph is provided in Fig. 5 for the rapid solution of this formula. The scales to be used are a and v0, which give the pressure rise in feet of fluid on the hmaT scale. From the relation, wh . P=l44 PSJ (16) where h = pressure expressed in feet of fluid, conversion to (Pl -- P,,), shown on the nomograph as the pmaI scale, is accomplished by intersecting the proper value for w and the value of hmax already de termined and reading (Pi~Po) on the pmai scale. The dashed lines (Fig. 5) illustrate the proce dure. To determine the pressure rise resulting from sudden valve closure in a pipe carrying water (to = 62.4 Ib/cu ft) at an initial velocity v0 of 12.7 feet per second where the velocity of the pressure wave a is 4000 feet per second, place a straightedge from 4000 on n to 12.7 on o,,. Read 1570 on hmax. Intersect 1570 on hmaT and 62.4 on to. Read 680 psi on pmal (= Pi-Po)The maximum pressure experienced at the valve will be given by Pm=Pl +P//V2 psi (17) where pi is the pressure drop in the system (psi) during initial flowing conditions pn and vn. (Ref. 21) Pressure-Excess Volume Relationship From Equations (10) and (14) an expression for the pressure rise resulting from the presence of an excess volume of fluid, V, -- VQ, is obtained: (Vj-VoJfl*!*) . Pi P 144ALg psi (18) V, -V0 _. AL(i+i)or, P\ Pa- /J d \ PS1 (18a) If Equation (18a) is solved for k an unknown bulk modulus may be determined in a simple laboratory setup requiring only a pressure gauge and a hand pump of known displacement. Effective Velocity in Complex Conduits The initial flowing velocity o0 may be found from the relations, .. _ 0.4085Qo _ 0.002228Qo r_,, ^0 2 *P nm V/ where Q0 -- initial flow rate, gpm d = inside diameter of pipe, inches A = flow area of pipe, square feet Although pressure reflections occur at points where the pipe changes thickness or diameter, these reflections do not appreciably affect the pressure rise during the first water hammer cycle. For all practical purposes the effective flowing velocity of the fluid ve may be derived from energy and continuity con siderations and expressed: . ~f~ LbVb ~t~ Lyt/y La Lb + Lx v.i ' VB ` ' Y fps (20) where L = pipe length, feet v = flowing velocity of fluid, fps subscripts A, B, ... N refer to sections of the complex piping system. The Case of Slow Fluid Deceleration The Time Parameter, A In our preceding analysis we have been consider ing instantaneous closure of the valve. All the phe nomena described and mathematical relationships derived hold true if the valve is closed in less time than it takes the pressure wave to travel from the 19] O O O/^ A n A 0 O 2 S goo o o 2 -- 2 CD cd n co n llllllllllllllllllillllilLlJll 0o 2o _oin 50o(J| oCD o t"- o CD o m o o to Jllil|.t..l.ii.l.m It! I ilinilitnlmilniili II il II11 in A \\ S\ 8 2 in ^ to cm iilmliuli I llllllllllllilllilli 1 1 1 1 IlHll I llKllJlllllllll.lllllllll.1 o| > o o I O' CM \\........... /................... ................................... [iin|i 11111111 j 11 i 1 |i|i|i|i(|i|i"|r||l,l 1 j 1111111111 > 11 11 TTT a V) O 0 O O 0\ O 0 O O 0 0 \g hu. 0m in sr O in to 0 10 in CM \l O O O CM 0000 0 0 0 O 0000 0 O O 0 in to cm - 0 cn CD o o r- o O CD to I-- u. 0 in to O O to O in CM 0 0 cm I5C '1 O O 0 cn 0 a> O to N " CD O m O cr 0 in O to CM CM in cn as r- cd [10] Fig. 5. Nomograph for Pipe Line Parameter K valve to the reservoir and back to the valve, a time equal to 2L/a seconds, and designated as p, the period of the pipe. If, however ,the valve closes in T seconds, an in terval longer than p, the ratio of its closing time to the period of the pipe is expressed by the symbol N, the time parameter of the system. 2L M = -- sec (21) _T T aT . , N = -- = intervals (22) For rapid determination of N a nomograph is presented as Fig. 6. The dashed lines exemplify its use. In a system containing 1000 feet of pipe, where the velocity of the pressure wave is 4000 feet per second, find N for a valve closure time T of 1 second. Using a straightedge, intersect 4000 on a and 1000 on L. Read p = 0.5 sec. Now intersect 0.5 on p and 1 on T. Read 2 on N. Pressure-Velocity Relationship When the valve is only partially closed during the first interval p, only a portion of the original liquid velocity has been converted into strain energy. If v,, and Vj are the initial and reduced velocities and p0 and pi the corresponding pressures, the relationship may be derived from an extension of Joukowsky's Law, Formula (15): Pi-Po = 244^(u-Ci) psi (23) For a valve closure time T>p and therefore N> 1, at the beginning of the second interval two pres sure waves will be starting from the valve--a positive wave of magnitude proportional to the fluid velocity destroyed during the first interval, and a negative wave which, originating at the instant of valve movement, has already traveled as a positive wave to the reservoir and returned to the valve during the first interval p. Algebraic addition of these two pres sures gives the resultant pressure rise at the valve for the instant considered. Actual calculation of the pressure rise for any con dition of fluid velocity, pipe length, and time of valve closure (T>p) is a matter of considerable complexity. Several authors have presented a vari ety of solutions, chief among which should be men tioned the formulas and arithmetic integration method of N. R. Gibson (Ref. 5), the graphical solutions of M. L. Bergeron (Ref. 6), Dawson and Kalinske (Ref. 7), and Angus (Ref. 8). Allievi's Theory of Water Hammer For ease of application the theory and charts of Lorenzo Allievi (Ref. 3) have found wide accept ance. A considerable number of full scale tests has proven the validity and accuracy of Allievi's theory for simple conduits and uniform valve closure. By expressing the flowing conditions of head and ve locity within the pipe by the dimensionless para meter K, such that K is equal to one-half the square root of the ratio of the kinetic energy to the initial stored energy within the pipe, the conduit parameter K may be written: Substituting the values of W0 and Ws from Equa tions (12) and (9b), and using in place of the pres sure rise pi -- p0 the initial pressure pn K = aWV 28Sgp,, Since p0 = wH0/144 psi (25) (16a) where H0 = pressure in feet of fluid for initial con ditions, the conduit parameter can be reduced to Allievi's original form: K = avo 2gff0 (25a) The nomograph previously cited, Fig. 5, provides for rapid determination of K. As an extension of the example given to illustrate the solution for rapid fluid deceleration pressure rise, consider an initial pressure p0 of 173 psi at the valve. Find K. Using the relationships po -- wH0/144 and K = hmax/2H0 first solve for H0 by intersecting 62.4 on w and 173 on po- Read 400 on Ho- Now using the value of hmai previously found (1570 ft.) intersect 400 on H0 and 1570 on hmax- Read 2 on the K scale. Employing the parameters N and K as the axes of a Cartesian diagram, Allievi plotted the ratios Z- of the total surge pressures to the initial flowing pres sures as a series of diagonal lines. A reproduction of the Allievi chart is included as Fig. 7. An enlarged section showing small values of K and N is given in Fig. 8. Figures 7 and 8 are reprinted from the Sym posium on Water Hammer through the courtesy and with the permission of the American Society of Me chanical Engineers. For large values of K and N the chart, Fig. 9, reproduced by permission of McGraw-Hill Book Company from Rich's Hydraulic Transients, copyright 1951, is presented. The quantity Z is defined by the equation Z2-^Z-1 = 0 (26) Ul] oT N= 2L L SEC. FT. 10-3 25000--1 20000-i 15000-1 10000^ fl = 2L n=4- FT./ SEC. ^-5000 ^-4500 5000 2^1 4000 3000 2000 1500 1000- 5 * - 4 *500 - 400 .3 300: .2- 200: 100I-d .05 .04 .03- .02^ 50 40 30 20-1 !ri Ol-d .005 .004 .003 .002 --3 54^ 3 2- SEC. I0^ 5-i 4-1 3-J 2^ ^-4000 ^-3500 E- 3000 -2500 .511 .4 .3 -j .2-1 i .05-1 .04-1 .03-| .02-1 .01- - 2000 1500 - 1000 - 900 - 800 jr-700 Fig. 6. Nomograph for Time Parameter N [12] N |r60 j- 50 IP 40 30 i-20 - 15 W 10 9 jr 8 I* 5 E4 3 E-2 09008 ^ CM Sf CO 00 3 N AXIS OF PIPE . LINE CONSTANT 4.0 5.0 aVp K = 2g Hq 15.00 10.00 AXIS OF TIME CONSTANT 1.70 1.10 = Z 2 1.20 1.30 1.40 Fig. 7. Chart for the determination of pressure ratio Z1 for uniform conduits, from L. Allievi's Theory of Water Hammer. Repro duced from Symposium on Water Hammer by permission of The American Society of Mechanical Engineers. (Dotted lines indicate interval at which maximum pressure occurs.) [13] 0Vn AXIS OF PIPE LINE CONSTANT K= mj[gH0 0 0.5 1.0 .1.5 2.0 Fig. 8. AUievi chart--pressure rise for uniform gates and simple conduits--small K and N. Reproduced from Symposium on Water Hammer by permission of The American Society of Mechanical Engineers. 18 20 22 24 K (/>) AXIS 28 30 32 34 36 38 40 Fig. 9. Allievi chart--pressure rise for uniform gates and simple conduits. Large K and N. (ASME Paper No. 44-A-42.) Reproduced by permission of McGraw-Hill Book Company from Rich's Hydraulic Transients, copyright 1951. Further reproduction not authorized. [14] . To illustrate the use of these charts let us further extend the examples previously cited. Given data: Pipe length, L = 1000 ft velocity of pressure wave, a = 4000 fps valve closure time, T = 1 sec initial pressure, p0 = 173 psig specific weight of fluid, tv = 62.4 lb/cu ft flowing velocity, v() = 12.7 fps Find the total surge pressure, pi- Values for N ( = 2) and K ( = 2) have already been determined. Using the enlarged chart, Fig. 8, at the intersection of K = 2 (horizontal axis) and N = 2 (vertical axis) read Z2 = 2.8. 200 PSI-------------------------------------------------------N---------------- ------------ PRESSURE AT VALVE ^--------------- PRESSURE AT 1000' U.------ VALVE CLOSES' 200 PSI - 100---- o --: 0 - I 1-- I -I 1------------- 2 5 PRESSURE AT PUMP [2000') -I ( 4 SEC.----- S 4. 7 Since Zp. -- totol surge pressure _Pi_ initial pressure pn . i Da/ the maximum pressure pi for the example given will be 2.8 X 173 = 484 psig. Surge Wave Shape for T > ft Tracings of three simultaneously recorded pres sure-time measurements made at the valve, at the mid-point of the pipe, and at the centrifugal pump discharge in a fuel transferring system are shown in Fig. 10. The rounded wave shape is characteristic of valve closure times X> u. Test conditions were the following: Pipe length, L = 2066 ft Velocity of pressure wave, a = 2780 fps Specific weight of liquid, to = 50 Ib/cu ft Initial flowing velocity, v0 = 6.8 fps Valve closure time, T = 3.6 sec Initial pressure at valve, p0 = 20 psig Total surge pressure, p i = 130 psig Static no-delivery head of pump = 50 psig From these data K and N are determined to be 5.10 and 2.32 respectively. Application of the chart, Fig. 7, yields a theoretical value of 6.5 for Z-, which is in excellent agreement with the measured pressure ratio. Fig. 10. Simultaneous Pressure-Time Records for Slow Closure It is worthy of note that during the half cycle of reduced pressure the minimum pressure recorded at the valve was 12 psig. As the pressure reduction, 20-12 psi, is a measure of the reverse flow velocity, --D, of the liquid which is flowing toward the pump during the interval between L/a and 2L/a, it is obvious that -- v is considerably less than the initial velocity v0. The maximum pressure will therefore occur during the first cycle under these and similar conditions. Dampening of the pressure oscillations will be rapid, the asymptotic value being the static no-delivery head of the pump. Effective Velocity of Pressure Wave In a complex piping system the effective value of a will be that of the section of pipe nearest the valve when T<g. When T>/x, or in systems employing suppression equipment, the effective velocity of the pressure wave, n -- La + + .. Lx fps La + Lb+ Lx Qa an ax (27) where subscripts A,B .. .N refer to the individual section of pipe. [15] PART II--SURGE SUPPRESSING DEVICES Based on an understanding of the phenomena of water hammer and the.application of the principle that the pressure rise is proportional to the rate of deceleration of the fluid, a number of surge-control ling devices have been developed to bring the col umn of moving liquid to a more gradual stop. These devices may be divided into two basic types: those which by-pass some of the fluid around the shutoff valve and those which temporarily store some of the fluid in a tank or compression chamber. By-Pass Type Suppressors By-pass suppressors reduce surge pressures by effectively increasing the time of valve closure, T, with resultant proportional increase in the value of N. For any given value of K, the ratio, Z2, of the maximum pressure to the initial pressure will be reduced accordingly, as graphically illustrated on the Allievi charts, Figs. 7-9. Relief Valve The simplest form of a by-pass suppressor is the relief valve, which may discharge either to atmos phere or into the piping downstream from the shut off valve, according to the requirements of the sys tem. Two schematic diagrams showing possible - SUPPLY TANK pump, slamming the check valve closed, and, if re lief were not provided, producing severe water ham mer. A more detailed description and analysis of uphill pumping systems will be found in Part III. The chief advantages of a relief valve are its small size, ease of installation, and low first cost. Its limi tations often outweigh these considerations. It can not store the fluid in the system. It may require fre quent inspection and maintenance. The inertia of its moving parts may cause it to open and close in unison with the arrival and departure of the surge wave,thus magnifying the conditions it is intended to control. Automatic Surge Suppressor These objections have been overcome in the Au tomatic Surge Suppressor, shown in Fig. 13 and re- Fig.ll. Relief Valve at Shutoff Valve Fig. 12. Relief Valve in Pump Discharge Line arrangements of systems incorporating relief valves are presented in Figs. 11 and 12. In Fig. 12 an uphill pumping system is shown. With power failure, the column of liquid slows down and stops when its forward momentum is converted into friction losses and potential energy. It then surges back toward the [16] Fig. 13. Automatic Surge Suppressor (Courtesy Pelton Water Wheel Co.) produced through the courtesy of the Pelton Water Wheel Company. Power failure in an uphill pump ing system de-energizes the solenoid control, C-53, allowing system pressure in B chamber to open the main valve. When the valve is fully open, a revers ing mechanism admits system pressure to A cham ber and the valve slowly closes, its rate depending upon the adjustment of needle valve D-7 in the oil- filled dashpot. Automatic Surge Suppressors of this type have found their greatest acceptance in water supply and hydroelectric systems, where they are installed at the outlet of the check valve in uphill pumping systems, or on the upstream side of the turbine control valve in hydroelectric systems. Storage Type Suppressors Surge Tanks The oldest surge suppressor in use is the surge tank, shown schematically in Fig. 14. it is a large liquid, a significant reduction in the size of vessel required to limit the maximum developed pressures would be obtained. Pressure vessels designed for this function are referred to as air chambers, and are shown schematically in Fig. 15. The volume oc cupied by the entrapped air at the pressure existing standpipe open to the atmosphere and having a cross-sectional area several times that of the line it protects. With rapid closure of a downstream con trol valve, as in a hydroelectric system, the water flowing in the supply line is diverted into the surge tank until the kinetic energy of the moving water column has been converted into added potential en ergy in the standpipe. A summary of the methods of analysis developed by Gaden and Calame and trans lated by Eugene E. Halmos is given in Mr. Halmos' article, "The Effect of Surge Tanks on the Magni tude of Water Hammer in Pipe Lines," in Sympo sium on Water Hammer (Ref. 4). Improved performance at lower installation cost is obtained by the use of an internal riser pipe and a two-directional orifice control in the Johnson Differ ential Surge Tank. The analysis developed by R. D. Johnson will be found in References 9 and 10. The advantages of a surge tank are its over-all efficiency and negligible maintenance requirements. When a surge tank is planned and constructed dur ing the installation of the associated piping system, its first cost may be reasonable. Addition of surge tanks to existing systems, however, may involve con siderable modification and expense. The use of surge tanks is limited to water handling systems. Air Chambers If the top of the surge tank were closed, thus pre venting the escape of the air entrapped above the in the main flow line during steady state conditions is defined as the CAPACITY of the air chamber. As suming isothermal conditions, the air volume varies inversely as the absolute pressure. When flow in the main line is stopped, surge reduction is effected by conversion of the kinetic energy in the system into elastic energy stored in the compressed air as well as in the pipe and liquid. Air chambers possess the following advantages over open-top surge tanks: reduction in size, par ticularly in the required height, and a simpler and less costly installation. Opposed to these benefits, air chambers exhibit certain serious shortcomings. If the pressure in the main system is ever reduced be low the design pressure for steady flow conditions, the air chamber will lose some of its entrapped air and, as a result, its capacity will be reduced. The solubility of air in water and various other liquids makes recharging the air chamber imperative at fre quent intervals. In some systems a small air com pressor is installed to perform this service. The num ber of liquids which may be satisfactorily handled with an air chamber is limited. Gas-Liquid Separating Media . Correction of the deficiencies inherent in the air chamber could obviously be accomplished by sep arating the air or other gas from the liquid surface by a movable piston or by some flexible material capable of stretching like a sleeve or diaphragm, [17] collapsing like a bladder, or expanding like a bel lows. Once the type had been established, the ma terial must be chosen to meet the requirements of flexibility throughout the operating temperature range, fatigue strength for the expected life cycling of the device, and chemical inertness to the liquids handled by the associated system. Consideration should be given to the strength-to-weight ratio of the material, since its section modulus will govern its sensitivity to the differential pressures imposed. Insertion of any gas-liquid separating medium im mediately affects the rate of heat transfer during compression of the gas. It was assumed that iso thermal conditions prevailed in the true air chamber device. Test results have indicated the validity of this assumption. Thick diaphragms or gas-filled bladders of syn thetic rubber possess insulating properties which reduce the transfer of heat during the compression cycle and more nearly approach adiabatic condi tions. From the basic gas laws p0Con = PmCm" (28) where p and p,,, are the initial and final absolute gas pressures, C0 and C,,, are the corresponding gas volumes, and n is the polytropic exponent of gas ex pansion, for a required volume, Cm, the value of C0 depends upon the value of n. For the complete trans fer of generated heat, isothermal conditions prevail, n = 1, and Equation (28) reduces to Po*C0 = pmCm (28a) When no heat is transferred, n is equal to the ratio of specific heats (n = 1.4 for nitrogen gas). When some heat transfer occurs the value of n lies be tween 1 and 1.4. It is obvious from the foregoing discussion that for a specified volume at maximum pressure, C,,,, the smallest initial volume or capacity Co will be required when the value of n approaches 1. Suppressors having the lowest value of n will thus be most efficient. Actual values for n applicable to pneumatic sup pressor operation are not constant, but vary inversely as a function of the time interval during which the suppressor receives the volume of liquid C0--C,,, displaced from the associated piping system. In the following discussions the cited values for n apply to systems protected by adequately sized suppressors whose filling time--a function of line length, sup pressor capacity and proper orificing--is three sec onds or longer. For systems having line lengths less than 3000 feet or for a pressure ratio pm/po greater than 5 the suppressor will fill in less than three sec onds and n will approach the adiabatic value. [18] Piston-Type Suppressors A cross-sectional sketch of a floating piston-type suppressor is shown in Fig. 16. Close machining tol erances are required to allow easy movement of the plunger. Piston friction and inertia may result in delayed response to pressure differences with the result that the piston, acting like a dead end, may Fig. 16. Floating Piston Type Suppressor reflect the front of a surge wave instead of absorb ing it. The principal drawback to a piston suppres sor is the slow but constant leakage of the pressur izing gas past the O-rings. Frequent maintenance and inspection are necessary. The O-ring material is critical, since it must withstand abrasion, chemical attack, and remain dimensionally constant through out the temperature range imposed by the fluid han dled in the system. For piston-type suppressors, a value of n between 1.2 and 1.3 may be employed. Bladder-Type Suppressors The generic type referred to as a bladder-type suppressor is illustrated diagramatically in Fig. 17. Pressurizing gas--air or nitrogen--expands the blad der against the walls of the external housing. The volume of liquid entering from the associated sys tem collapses the bladder and compresses the gas. For suppressors of this type, the value of n de pends upon the material and thickness of the blad der. In most instances it will be between 1.15 and 1.25, as determined from reliable test data. Among the advantages claimed for the bladdertype suppressor are ease of installation and reason able first cost. The principal disadvantages stem from the blad der itself. When the device is not in active use--that is, when surge pressures are not being applied--the fibers of the bladder are under a constant strain from the internal gas pressure. Continued flexing and abrasion from the housing walls weaken these Values of n ranging between 1.15 and 1.2 are ap plicable to suppressors of this construction. Because its configuration permits the suppressor to be installed either in the main flow line or on a branch connection (with one end capped), a series of tests was conducted as one phase of the cited in- Fig. 17. Bladder Type Suppressor fibers and result in premature failure. The material itself--usually neoprene or Buna N--has a definitely limited field of applications, since it is attacked by many fuels and most chemicals in common use. Its usable temperature range is from about --20 to -F130 F. Because of the critical nature of the blad der, frequent inspection and replacement may be required. Diaphragm-Type Suppressors Figure 18 illustrates a suppressor of the diaphragm type. Its similarity to the bladder type is apparent. Since the diaphragm is usually made of neoprene or Buna-N, the evaluation of the bladder suppressor will apply as well to the diaphragm type. Fig. 18. Diaphragm Type Suppressor Sleeve-Type Suppressors An interesting variant of the bladder type sup pressor is shown in Fig. 19. Liquid in the system passes through the central pipe which is perforated with small holes along its entire length. A synthetic rubber sleeve, attached at both ends, encompasses the pipe. The outer housing contains the pressuriz ing nitrogen gas. Increased liquid pressure inside the central pipe causes the sleeve to swell, com pressing the gas in the housing. vestigation to determine the relative surge reducing characteristics of the alternate installations. Over a wide range of variables--flow rates, system pres sures, line lengths--no measurable difference could be determined. It was concluded that an "in-line" suppressor was equivalent to an "appendage" sup pressor and its position in the system should be gov erned by piping and space requirements. [19] The chief advantages of the sleeve-type suppres sor are its simplicity of construction', optional posi tioning for installation, low ratio of weight to ca pacity, and usually reasonable first cost. The disadvantages are mainly attributable to the synthetic rubber sleeve, which has a limited flexural lie, and which becomes brittle below -- 30F and tacky above +120 F. Even at moderate ambient temperatures, between + 50F and + 100F, the sleeve may allow the pressurizing gas to escape. Synthetic rubber is attacked by aromatic hydrocar bons, by most acids and bases, and by many salts. Pneumatic Bellows-Type Suppressor Suppressor construction which successfully over comes temperature limitations, chemical attack, loss of pressurizing gas and flexural fatigue is accom plished in the stainless steel bellows design, one gen-pressurized suppressor of the type shown in Fig. 21 was-developed by MagniLastic. Gas, charged into the domed housing to the pressure maintained in the system during initial steady flow conditions, compresses the bellows assembly. Liquid displaced Fig. 21. Pressurized Hydropad from the system during surge conditions enters the bellows, extending them and compressing the gas (Fig. 22). In the configuration shown in Figs. 21 and 22 the top plate terminating the bellows assem bly, the bellows diaphragms, and the lower attach- Fig. 20. Non-Pressurized Hydropad form of which is shown in Fig. 20. This unit, de signed and fabricated by the MagniLastic Division of the Cook Electric Company, and designated the "Hydropad," contains an inner collapsible chamber filled with air or nitrogen gas at atmospheric pres sure. Liquid from the system fills the outer housing and surrounds the bellows'assembly. Surge pressures originating in the system are transmitted to the liq uid in the housing and absorbed by compression of the gas within the bellows. Because of its low first cost and the simplicity of obtaining any required capacity by connecting several Hydropads in series, this unit is especially adaptable to low pressure sys tems (50 psi and below). For application at pressures above 50 psi, a nitro [20] Fig. 22. Pressurized Hydropad with Bellows Extended ing ring are all fabricated from Type 347 stainless steel. Where all suppressor parts in contact with the liquid must be corrosion- or temperature-resistant, the entrance connection and a lower ring liner are also made of stainless steel. Such a design is shown in Fig. 23. Suppressors of this construction have an mended. Such a unit would find application in liq uid nitrogen or -liquid oxygen transfer systems and high temperature chemical processes. Standard models are produced in capacities rang ing from 60 cubic inches to 50,000 cubic inches in 200-, 500-, 1000-, and 3000-psi pressure ranges. Other i Fig. 23. Stainless Steel--Trimmed MagniLastic Hydropad Fig. 24. 55,006 Cubic Inch Hydropad operating temperature range from -- 85 F to -f 750 F and have given years of trouble-free serv ice in'fuel, chemical, beverage and water handling systems. For greater temperature extremes (--325 to +1000 F) an all-stainless steel model is recom capacities and pressure ranges are available on spe cial order. Six units of the construction shown in Fig. 24 were installed at the terminus of a five-mile fuel transfer line to limit maximum surge pressures to 250 psi. This installation is shown in Plate V. Each i i f i [21} suppressor has a capacity of 55,006 cubic inches and is precharged with nitrogen gas to the line pressure of 100 psi. Welding of the lowest bellows diaphragm to the bottom plate provides an effective seal against loss of the pressurizing gas with resultant reduction of maintenance requirements and complete elimina tion of hazard to operating personnel. All welding is performed in MagniLastic shops by governmentcertified welders. Design, fabrication and testing are conducted in accordance with the applicable requirements of the API-ASME Code for Unfired Pressure Vessels. Tests made under laboratory controlled condi tions have demonstrated the life expectancy of stain less steel MagniLastic bellows assemblies to be in excess of 10,000,000 cycles of completely reversed stress at full travel produced by the alternate appli cation and release of fluid pressures. By extensive test a value of 1.015 for n has been determined for MagniLastic Hydropad construction. Close approach to isothermal conditions results in high over-all efficiency. Evaluation of Storage-Type Suppressors The following Code.is used in the table below: 1-- Excellent, 2--Very Good, 3--Good, 4-- Fair, 5--Poor, 6--Very Poor. TYPE Cost vs. capacity Weight vs. capacity Maintenance frequency Gas leakage or absorption Liquid leakage Life expectancy Operational safety Efficiency Operating temperature range Range of liquids handled Averages Air Chamber 1 1 6 6 1 1 2 1 6 6 3T Floating. Piston 3 3 5 5 5 4 2 5 5 5 il Bladder 3 2 4' 1 1 4 3 3 4 4 Diaphragm 3 2 4 3 2 4 3 4 4 4 3B Sleeve 2 2 3 3 2 3 2 3 4 4 Hi Bellows 3 3 1 1 1 1 1 1 1 1 L4 PART HI--SURGE CONTROL WITH PNEUMATIC SUPPRESSORS Effect of Suppressors When the velocity of a fluid flowing in a conduit is decelerated from vn to any new value, vt, with a PRESSURE AT VALVE PRESSURE AT 1500' 300PSL 200 -- 100 --- VALVE CLOSES --i------- 1------- 1------- H 2 3 A SEC 5 PRESSURE AT PUMP (3000') T6 7 Fig. 25. Simultaneous Pressure-Time Record for a System Incorporating Suppressors [22] resultant increase in pressure, an adequately sized pneumatic suppressor will displace a quantity of fluid over a sufficiently long period of time to es tablish a new value of N, the time parameter, such that N> 1 and the resultant pressure rise is corre spondingly reduced from the maximum value found by applying Equation (22). In this respect inclusion of a suppressor produces a smooth and gradual pres sure build-up similar to that of slow valve closure. A tracing of three simultaneous pressure-time rec ords sensed in different locations in a fuel transfer ring system will be found in Fig. 25. Similarity of these pressure records to those made during slow valve closure (Fig. 10) should be noted. With respect to Fig. 25, the following test condi tions were recorded: ' Pipe length, L -- 3078 ft Flow area of pipe, A = 0.192 sq ft Test fluid: JP-4; Specific weight, to = 50 lb/ft5* Velocity of pressure wave, a ~ 2930 fps Flowing velocity of fluid, v,, = 7.1 fps Total suppressor capacity, C0 -- 2.836 cu ft Effective value of polytropic exponent, n -- 1.125 Initial pressure at valve, p0 = 50 psig Maximum pressure at valve, pm -- 260 psig ' Suppressor precharge pressure, p = 50 psig It should be noted that at the instant of maximum surge pressure at the valve, pressures within the sys tem diminish toward the pump. The average pres sure rise, (pm -- p,>)/2 should be used in calculating the amount of pressure energy at that instant in the expanded pipe and compressed liquid. the suppressor is equivalent to the flow pressure, p,,. At the instant of maximum surge the suppressor will have stored a quantity of potential energy, a, such that <j=14^C.[(&l)V_1]ltJb (30) and simultaneously the expanded pipe and com pressed liquid will store, with an average pressure rise (p,,,-Po)/2, an amount of energy, 8: I = wa(feia)` ft-lb (31) The Energy Balance Assuming valve closure in less than 2L/a seconds, the method of balancing the energy present in the system before and during valve closure against the energy stored in the compressed gas within the suppressors and the elastic energy stored in the expanded pipe and compressed fluid at the instant of maximum pressure is the most satisfactory theo retical approach to the sizing of pneumatic suppres sors. Sufficient empirical data were recorded during controlled tests to prove the validity of the formulas and their applicability to all ranges of pipe diam eter, length, flow velocity, suppressor capacity, and any other variables. The following brief discussion presents a simpli fied form of the hydraulic energy balance. Its deri vation and a more detailed theoretical analysis will be found at the end of Part III. As corroborated by test data, the formulas given here will yield con servative results from zero to five percent. The energy present in the system before and dur ing valve closure is the sum of the kinetic energy W,, = wALv,,-/2g ft-lb (12) where w = Specific weight of fluid, Ib/cu ft A -- Cross-sectional area of pipe, sq ft L = Pipe length, ft v0 -- Initial fluid velocity, fps g = Acceleration of gravity=32.2 ft/sec- and the flow work y of the liquid entering the pneu matic suppressor: y = 144p,,*C,, [ 1 - " ] ft lb (29) where p0 = Initial flowing pressure, absolute, psia C(l = Capacity of suppressor, cu ft pm = Maximum pressure, absolute, psia n = Polytropic exponent of gas expansion It is assumed that the initial charging pressure of in which a = velocity of pressure wave, fps p,,, and p,, are gauge values corresponding to pm and pft The energy balance is thus given by: Wo + y = a+5 ft-lb (32) Solution for the required suppressor capacity, C,,, yields C,, = Wo-* ^(SF-1]-144^-^)-] cu ft (33) At maximum pressure, p,,,, the corresponding vol ume, C,,,, occupied by the gas is . Cm = C,,(Ssl)~ cuft (34) The volume of liquid, Vrf, entering the suppressor is Vtf = C,,-Cm = C0 1- J cuft (35) The volume, Cx, occupied by the gas at any pressure Px is C' = C(S)~ Cuft (36) For non-pressurized suppressors where px=14.7 psia and for suppressors charged to some pressure, px, other than line pressure, po, the required ca pacity, Cx, will be found from Equation (36), once the value of C0 is determined. To simplify the calculation of the pressure ratio factors, Figs. 26 and 27 have been prepared in which the value of n, determined from test data as applicable to suppressors of MagniLastic stainless steel bellows construction, is taken at 1.015. [23] [24] If Equation (33) is put into the form c -W0-S . ~~p?T cuft where Y = 144/ (33a) The value of a can be determined from the nomo graph, Fig. 4, as 4160 fps- Actual calculation yields 12 -M)SJ (37) a convenient graphical solution of Y vs the ratio Pm/po for n = 1.015 can be-used to expedite the computation of C,,. This graph appears as Fig. 28. By its use a close approximation of pm for a given suppressor capacity C0 may also be found. The error lies in the predetermination of 8, which may usually be estimated within a few percent once the constants in Equation (31) have been evaluated. Line friction drop is included in the term 7. Refer to Hydraulic Energy Balance, page 28. The maximum initial liquid velocity v0 permitted for a given suppressor capacity, C0, initially charged to line pressure, p0, and limiting the maximum surge pressure to pm is (&) ---ij--^c.| . The following example is given to illustrate the use of the formulas in a simple system. Given data: Pipe length, L = 10,000 ft Pipe size: 10-inch schedule 40 (See Table V) Pipe I.D., d = 10.020 in. Pipe wall thickness, e = 0.365 in. Flow area, A = 0.548 sq ft Pipe material, steel Modulus of elasticity (Young's), E = 30,000,000 psi Liquid handled: Water Specific weight of water, w = 62.4 lb/cu ft Bulk modulus, k = 294,000 psi Initial flow rate, <> = 1000 gpm Initial pressure at valve, p0 = 75 psig Atmospheric pressure, p,, = 14 psia Valve closure time, T = 2 sec Polytropic exponent of suppressor gas compres sion, n --1.015 Acceleration of gravity, g = 32.2 ft/sec2 Allowable maximum surge pressure, pm = 200 psig Solution: By (19) the flow velocity, 0.4085Oo 0.4085 X 1000 _ ,, ^ "=-----7$-- =---- IO0205----------4 ^ a = 10.020 [2 \ 294,000 0.365 X 30,000,000/ = 4157 fps Valve closure time resulting in N<1 may be regarded as "instantaneous." Solution for N may be made by means of the nomograph. Fig. 6: N <1. By calcula aT tion: N = 2L (22) N 4157 X 2 ~~ 2.X 10,000 = 0.4 AT< 1 The pressure rise, pi -- p0, resulting from instanta neous valve closure for a system without suppressors would be v0tea Pi~Po = 144g (15) 4.07 X 62.4 X 4157 Pi-P=- 144X32.2 228 psi Under these conditions, and neglecting line drop, the peak pressure, p% = 228+p0 = 228 + 75 = 303 psi. The suppressor must accordingly reduce the maxi mum pressure by . 303 - 200 = 103 psi The kinetic energy in the system is W0=wALvq2/2g ' (12) W0 = 62.4 X 0.548 X 10,000 X 4.072 2 X 32.2 = 87,956 ft-lb The strain energy stored in the pipe at the instant of maximum surge, by Equation (31) is ,, _ 10,368 X 0.548 X 10,000 X 32.2 /200 - 75 \ 2 S_ 41572 X 62.4 \ 2 / 8 = 6,627 ft-lb Since p = po + Pa = 75 + 14 = 89 psia and pm --pm + pa = 200 +14 = 214 psia and since n = 1.015, l/n = 0.985 and (n --1 )/n = 0.0148, the required MagniLastic suppressor capac ity can be found directly from Equation (33): 87,956 - 6,627 144 X 89T/214\ 0.0148 "1 1.015 -- lL\ 89/ -- 1 -144X89 C0 = 21.54 cuft [25] [26] Fig. 27. 21 vs. Pm \PmJ Fig. 28. 24 vs. Y Pu [27] This computation may be checked by using the sim plified method provided by Formula (33a) and Fig. 28: p,,,/pi,e = 2.41 read Y = 42.5 from Fig, 28. By (33a): Co- 87,956-6,627 89 X 42.5 = 21.5 cu ft By Equation (35) the volume of water entering the suppressor is Vd = 21.54 [ 1 - (J^j '985 ] = 12.47 cu ft At the instant of maximum surge the pressurizing gas will occupy a space Cm = Co - V,, = 21.54 -12.47 = 9.07 cu ft It will be interesting to examine the actual dis tribution of energy in the example just given. Solu tion for a, the energy stored in the gas of the sup pressor, by (30) yields: _ 144 X 89 X 21.54 T /214 \ 0 0148 1 " 1.015-1 [_(, 89 / = 241,156 ft-lb The potential energy or flow work y of the liquid entering the suppressor, which must ultimately be expelled by part of the energy a, is, from Equation (29): y = 159,827 ft-lb [i-(m) J/ oq \ 0.985 1 Summarizing, Wo + y = a + 8 87,956 +159,827 = 241,156 + 6,627 It is noteworthy that the energy stored in the sup pressor is 2.7 times the kinetic energy present in the system before valve closure and that the potential energy of the liquid entering the suppressor makes 66% of the stored energy unavailable for absorption of the kinetic energy. Complex Systems Changes in pipe diameter and wall thickness affect the values of W0 the kinetic energy and 8 the pres sure energy stored in the pipe. Where subscripts A, B .. .N refer to individual sections of pipe in a com plex system, the modified expression for the total kinetic energy present before valve closure is Wo = 2ioAL02/2g = (m/2g)2ALt>02 W0 = (w/2g) (AaLava2 + A,,IW + - A.vLvO,-2) ft-lb (39) [28] With the application of Equation (20) this formula can be simplified to the form: W0 = (w/2g) Vve2 ft-lb (12a) in which vr is the effective flow velocity and V the total volume. The pressure energy stored in the complex system at maximum surge is: <> where a,, the effective velocity of the pressure wave will be found from Equation (27). No changes are required in Formulas (29) or ( 30) for calculation of y and a respectively. The energy balance, W,,+y=a+S, and Formula(33)and(33a) for C,i are to be applied without revision except for the new values of W0 and 8j, as found from Equa tions (12a) and (31a) above. For example consider a complex piping system containing, as in the preceding problem, 10,000 feet of schedule 40 pipe, but of the following diameters eoofiAnal lpnffths: Section Nominal Diameter in. A (from pump) B c D E (to valve) 14 12 10 8 6 Length ft 5000 2000 1000 1500 500 Let the valve closure time be considered instantane ous, and let the other conditions stated in the former example apply. A table can be compiled presenting pipe details. Dia. "Wall in. " in. 14 0.438 12 0.406 10 0.365 8 0.322 6 0.280 I.D. in. 13.124 11.938 10.020 7.981 6.065 Flow Area Length sq ft ft 0.9396 5,000 0.7771 2,000 0.5479 1,000 0.3472 1,500 0.2007 500 Volume CU ft 4,698 1,554 548 521 100 Total volume, cu ft 7,421 Calculation of velocities of propagation of the pres sure wave gives, by (14): aA = 4109 fps aB = 4110 fps ac= 4157 fps aD = 4206 fps aE -- 4251 fps . If no suppressors were installed in this complex sys tem, the pressure rise experienced at the valve--at the end of the 6-inch line--would be the same as that for a simple system using 6-inch pipe throughout, since N< 1. With no suppressor capacity the rise, by (15) would be vEwaE . Pi p`l=-W psi in which vE and aE are the fluid velocity and pres sure wave velocity, respectively, in the 6-inch pipe. 11.101 X 62.4 X 4257 Pi - pn : 144 X 32.2 - = 636 psi The effective wave velocity ac is, by (27) _ 5,000 + 2,000 + 1,000+1,500 + 500 5,000 , 2,000 , 1,000 , 1,500 , 500 4,109 "**4,110 4,157 4,206 + 457 ac = 4,136 fps Flowing velocities t>0 and kinetic energies W,,, cal culated from Equations (19) and (12) respectively, are listed below. Orifice Filling Control If a flow-restricting orifice is interposed between the main flow line and the liquid chamber of the surge suppressor there results a net loss of kinetic energy from the acceleration and deceleration of the liquid as it passes through the orifice. Because conditions at the orifice are always transient it is not expedient to apply the standard relationships for energy losses across an orifice. Rather, let us exam ine a pressure-time record of surge pressures meas ured simultaneously on the inlet and outlet sides of an orifice plate employed in suppressor filling con trol. These tracings and a schematic diagram of the system will be found in Fig. 29. The valve begins Section A B C D E v0 Vo~ 2.371 5.62 2.867 8.22 4.066 16.53 6.417 41.18 11.101 123.23 w/2g V 0.969 4,698 0.969 1,554 0.969 548 0.969 521 0.969 100 w,, 25,592 12,377 8,779 20,789 11,941 Total kinetic energy, W,, = 79,478 ft-lb The equivalent effective fluid velocity for the sys tem, by (20): 5000 X 2.371 + 2000 X 2.867 4-1000 X4.066 + 1500 X 6.417 + 500X 11.101 V 5000 2000 1000 , 1500 , 500 2.371 2.867 4.066 6.417+11.101 ve = 3.3245 fps Using this effective value, the total kinetic energy can be checked by Equation (12a): W0 = 0.969 X 7421 Xfl.32452 = 79,477 ft-lb From Equation (31a) the energy stored in the pipe at maximum surge is s _ 10,368 X 7421X 32.2 /200 -75 \ 2 1 41362 X 62.4 V 2 ) S, = 9,066 ft-lb Since a and y have been affected only with respect to C,, by the change in pipe diameters, solution for Co can no.w-be made directly. Using Equation (33): ^_ 79,478 - 9,066 C,, = 18.65 cu ft FLOW METERING SECTION quick-cl'osing VALVE (C) SCHEMATIC DIAGRAM OF TEST SYSTEM Fig. 29. Pressure-Time Records for a System Incorporating Suppressors and Orifice Filling Control to close at time T0. At time T\ maximum flow is established through the orifice. The pressure in the system rises rapidly to p2. At this instant the pres sure drop across the orifice is p2 -- po. The sudden pressure rise from p0 to p2 has resulted from a re duction of the flow velocity in the system and through the orifice from t>0 to some new value vlt which may be found by a rearrangement of Equa tion (23): 144fi Vl =V~wa (P2-P) fPs (23a) At time Ti the kinetic energy in the system will ac cordingly be reduced to Wi =wALoi2/2g ft-lb (12b) Selection of the proper sized orifice for any par ticular application has long been based on conjec ture or trial and error methods. Too small an orifice produces the same water hammer conditions that would exist were no suppressors present. Too large [29] an orifice is little better than none at all. From ex tensive test data it has been determined that opti mum surge suppression results from the ratio: ---- = 0.68 Pm -- po ( 40) ' The orifice diameter do which will pass qi cubic feet per second of a liquid of specific weight w with a differential pressure of hw is found by applying Formula (98b) from the ASME Report on Fluid Meters (Ref. 11): ,, - 0.0997 (v^f) V/E" (41) m whVichL --==C=== = orifice coefficient of discharge v 1 P including velocity of approach factor, measured at 0.70 for a square-edged orifice under the cited test conditions do = orifice diameter, inches h,r = differential pressure across orifice, inches of water w = specific weight of fluid, lb/cu ft Using the value of 0.70 for the discharge coefficient, and converting the differential pressure into psi, the equation becomes: ql = 0.3674 do\/ Pz~Po cfs V ip Since qi = Aoj To illustrate the economies effected by the addi tion of orifice filling control, the suppressor-sizing examples previously presented will be recalculated to incorporate orifice control. Since the pressures p0 and p,,, are the same for both the simple and com plex systems, ratio (40) is applicable to both. p-i~p = 0.68 (p,n-po) p--pa = 0.68 ( 200 - 75) = 85 psi For the simple system, by (23a), the resultant new velocity is: Vi -- 4.07 -- 144 62.4 XX324.1257(85) t>t = 4.07 - 1.52 = 2.55 fps The orifice diameter, from Equation (42) is [30] 0.548 X 2.55 ( ------------- / \| | = 1.805 in. "ha ) The new value for the remaining kinetic energy in the system at time Ti is, by (12b): Wj = 0.969 X 0.548 X 10,000 X 2.552 = 34,529 ft-lb Except for C0, other factors in Equation (33) will remain unchanged. The new required capacity is thus: C,, = 34,529 - 6,627 C,, = 7.39cuft With the employment of the orifice the new sup pressor capacity is 7.39/21.54 or only 34.3% as large as the former requirement. For the complex system, considering conditions at the suppressor which is located near the end of sec tion E, the new velocity becomes Vi~Ve~ 144g, (Ps - \ Po) _ - 1iLi1m01i 144 X 32.2 /ogA 62.4 X 4257 ^ i = 11.101 - 1.484 = 9.617 fps The new effective velocity tVi for the entire system is thus el 9.617 X 3.3245 = 2.881 fps 11.101 The required orifice diameter, by (42) is: AeOi______\ o ("V ^ ] 0.2007 X 9.617 \ (WJj7 = 2.122 in. The residual kinetic energy Wi in the complex sys tem is - ` Wl = (w/2g)Vvel2 = 0.969 X 7,421 X 2.8812 Wt = 59,686 ft-lb The new required suppressor capacity is determined as before. r_ 59,686 - 9,066 Cq = 13.41 cu ft By the use of the orifice only 13.41/18.65, or 72% of the former capacity is now required. Series Systems A piping system composed of the components shown in Fig. 30a and consisting of a centrifugal pump, a length of pipe LA, a pressure regulating valve, a length of pipe L,,, and a quick-closing valve may be analyzed as two separate systems separated by the pressure regulating valve. Since the regulat ing valve will begin to close when the surge pressure has traveled from the quick-closing valve through section L,, the pressure waves will be reflected at the regulating valve and the downstream system Ltt may be considered separately. The sizing of a sup pressor located at the quick-closing valve is accom plished in the same manner as shown in the previ upstream from the valve. Where physical conditions do not permit such optimum placement, tests have shown that the suppressor may be located at any distance L, from 0 to 50 feet upstream from the valve without materially affecting the surge reduction. For distances greater than 50 feet, and for very short valve closure times, T, the maximum distance L, permitted for possible surge reduction cannot exceed aT/2. If iv, = intervals (22a) ew TEST SYSTEM EMPLOYING CHECK VALVE AT PUMP DISCHARGE (c) SUPERIMPOSED PRESSURE-TIME RECORDS FOR A SYSTEM EMPLOYING a CHECK VALVE Fig. 30. System Diagrams and Superimposed Pressure-Time Records ous examples, with only the energies present in sec tion Ltt to be accommodated. Similarly section LA may be considered as an individual system, in which the regulating valve functions like a quick-closing valve. A second suppressor, located at the regulat ing valve inlet, should be sized to accommodate the fluid energies present in section LA. Effect of Check Valves on Surge Characteristics The inclusion of a check valve at the discharge of the centrifugal pump in a piping system terminating in a quick-closing valve, as shown in Fig. 30b, does not affect the magnitude of the surge pressures pro duced by fluid deceleration but only their periodic ity. Superimposed tracings of pressure-time records for the same system and flow conditions with and without suppressors are presented in Fig. 30c. Com parison of these records with those of Figs. 3 and 25 will show the elimination of the reflected nega tive wave and the shortening of the basic cycle to 2L/a. Suppressor Placement In systems where fluid deceleration is produced by a quick-closing or pressure regulating valve the ideal location for a surge suppressor is immediately under conditions where Lj>aT/2, Ni <1, and the pressure rise at the instant of complete valve closure will be v,,wa/144g. For N, >1 the initial pressure rise at the valve may be determined by applying the parameters K and N, to the Allievi charts, Figs. 7. 8, or 9. The value of p\ thus found will establish the minimum value of p,,,. The rest of the system up stream from L, will be protected by the suppressor. When the suppressor has reached the maximum surge pressure pm the section of pipe L\ will expe rience the uniform pressure p,,,. Upstream the pres sure will diminish almost linearly to the pump or reservoir. In systems where Li is one-fourth to one-half the total length of pipe and where the period of the suppressor is nearly in phase with the period of the pipe pressure peaks may be produced on the third or fourth cycle considerably in excess of p,,,. The subject of resonance will be given further amplifi cation in a subsequent section. Uphill Pumping Systems , When the power is cut off from the pumps sup plying an elevated tank or rising section of pipe the column of liquid at first decelerates over a sensible period of time, during which its momentum is con verted into head and the rotary inertia of the pump is imparted to the fluid and lost in bearing friction. The flow then reverses, closing the check valve at the pump discharge and producing a pressure rise proportional to the velocity of reverse flow. Two studies of surge phenomena in pumping sys tems are worth examination. The first, an analysis of transient conditions in the Colorado River Aqueduct Pumping Plant, has been made by R. M. Peabody (Ref. 12). In the second, tests conducted on the Cro ton Lake Pumping Plant, New York, and reported by S. Logan Kerr in the Symposium on Water Ham mer (Ref. 4) present corroborating evidence. Gen eralized curves of flow, pressure, and pump rotation will be found in Figs. 31a and 31b. [31] From an examination of these data the following simplified analysis can be made. For systems in which the check valve is closed by the reverse flow, when the fluid velocity is zero the instantaneous pressure p;! at the pump is a minimum of 0.4p,,, where p, is the pressure equivalent of the static head. The maximum pressure pi recorded for a sys tem using a non-cushioned check valve is 2.1 p,,. The rise p, = (pi -- ps) is thus 1.7 p,,. By Joukowsky's Law, the maximum reverse flow rate ^_----1--4--4--g--(p-,---p--,-)--_---2--4-4_.8_g_p_,,_ fps (43) In systems containing a check valve which closes before flow reversal takes place, p:t becomes zero The parameter S, being independent of velocity and defined as z (P'D!IP) (45) Pi where p'= pressure gradient, lb/sq ft per ft -- 144(0.6 p,)/L D = pipe diameter, feet P = w/g = specific weight of liquid, slugs/cu ft Pi = dynamic viscosity, slugs/ft-sec may be determined directly. Lines of constant val ues of the S number will be developed by placing a straightedge between the scales at the top and bot tom of the chart. Fig. 32. Intersection of the straight edge with the applicable pipe friction curve will locate the values of N,, and f. The velocity - can be determined without the usual trial and error pro cedure, since the Reynolds number equation. Dvp NJl = pi may be solved for the velocity, (46) Fig. 31a. Flow, Pressure, and Pump Speed Curves for Power Failure in Uphill Pumping System Without Check Valve Fig. 31b. Flow, Pressure, and Pump Spe d Curves for Power Failure in Two Uphill Pumping Systems Incorporating Check Valves fps (46a) in which the units from Equation (45) should be employed. For a slow-closing check valve (T>g) the pres sure rise may be determined by application of the parameters K and N and the use of the Allievi charts. Figs. 7 through 9, wherein the fluid velocity v2 will have been previously determined from Equation (43) have been previously determined from Equa tion (43) or (46a). . In systems where the pipe friction loss pf is ap preciable the initial pumping pressure p0 will equal the sum of the static head p, and the friction and throttling losses pf. Since p/ vanishes at the instant of flow reversal the minimum pressure pa, as before, is 0.4 p,. The maximum pressure may be found by applying Joukowsky's Law: pi = 0.4p. + |g| psi (15b) and pi =2.1 p,,. The rise pr is thus 2.1 p,,. An alternate method of determining the velocity of maximum reverse flow has been provided in the study by S. P. Johnson (Ref. 13). Johnson postu lated a dimensionless parameter, S, related to the Reynolds' number N,, and the pipe friction factor f by the. expression S = Nr (44) [32] in which has been determined from Equation (46a). A conservative value of pi will result from the assumption that pi cannot exceed 2.1 p,. This as sumption allows the simpler solution provided by Equation (43). Limitation of the maximum surge pressure to p,,, may be effected by the installation of a pneumatic suppressor, precharged to the pressure p;i, and lo cated at the outlet of the check valve. If no orifice control is used the sizing of this suppressor is en- (Aj-kOi OiNQjtO Fig. 32. Relation between friction factor and Reynolds* number for flow in circular pipes, with added S Number coordinates. [33] tirely straightforward. The basic energy relationship, W., + y = a + Si, is employed. The slightly modified formulas are given below. Wo = (w/2g)Vvn- ft-lb (12c) !s = (rf ft-lb (31b) C,, = Wo -go______________________ cu ft (33b) vvhen an orifice filling control is included the ratio (P-2--p-.\) / (Pm--p.i) must be limited to a value such that pm--p 5 0.6pBsince the residual static head will inevitably be superimposed upon the orifice-induced system pressure p2. After setting pm--pz equal to 0.6p solve the ratio (p-i--p*)/(p,,,--Pa) If it ex ceeds 0.68 select a lower value of p-< to produce the optimum ratio of 0.68. Example: determine the suppressor capacity and orifice diameter required to limit the maximum surge pressure to 250 psig in the event of power failure in the following pumping system: Pipe length, L -- 11,500 ft Pipe size: 8-inch, schedule 40: d = 7.981 in. (0.665 ft) Pipe wall thickness, e -- 0.322 in. Flow area, A = 0.347 sq ft Young's modulus for pipe material, =30,000,000 psi Static head, H,, = 498 ft Pumping flow rate, (50 = 400 gpm Liquid pumped: aviation gasoline. Grade 115-145 Specific gravity of liquid: 0.690 at 60/60F (74 API) ' Specific weight, to = 0.69 X 62.4 = 43.1 lb/cu ft Kinematic viscosity, v = 0.640 centistokes at 60F Pressure equivalent of static head, p,, -- 43.1 X 498/144; p, = 149 psi Line friction drop at 400 gpm. p, = 11 psi Pump discharge pressure at 400 gpm, p,, = 149 + 11 = 160 psi Maximum allowable surge pressure, p,,, = 250 psig Solution: the bulk modulus of aviation gasoline at 60F will be found from Fig. 35 as 103.000 psi. The velocity of the pressure wave, V 32.2 \ 103S.000 a = 3189 fps 12 7.981 0.322 X 30.000,000; Assume that the check valve is closed by flow re versal. p:t = 0.4= 0.4 X 149 = 60 psi [34] The viscosity of the gasoline in slugs/ft-sec (from Tables II and III): . pi = v (centistokes) X (specific gravity) X 2.088 X 10-5 =0.640 X 0.690 X 2.088X10-=9.22X10-" slugs /ft-sec The pressure gradient, _ p' = 144(0.6p,)/L = -1--4-4---Xjjg0O.6OX-1--4--9--= 1.12 lb/sq ft per ft The S number, i ' ,, (p'D3p)" _ (1.12 X 0.665" X 43.1/32.2)" S~ ft, 9.22X10-" ' S = 72,000 From Fig. 32 an S number of 72,000 intersects curve 4 (for 8-inch pipe) at a Reynolds' number of 825, 000 and friction factor of 0.0153. By Equation (46a), 8.25 X 105 X 9.22 X 10-" = 8.546 fps 0.665 X 1.3385 without a suppressor the maximum pressure would be, by (15b): 8.546 X 43.1 X 3189 Pi = 0.4 X 149 + 144 X 32.2 Pi = 60 + 253 = 313 psi (Note that pi = 2.1ps) The suppressor must reduce this maximum pressure by pi -- pm = 313 -- 250 = 63 psi. Unless the resultant orifice ratio is greater than 0.68 the optimum orifice size will be such that p>n -- P`2-- 0.6 ps. or p-> = 250 -- 0.6 X 149; ps = 161 psi. , The orifice ratio. p-2 -- p:l _ 161 -- 60 _ Pm ~ Ps 250 - 60 Since 0.53 < 0.68 a value of 161 psi for is accept able. The reduced system velocity v, is, by Equation (23a) 144g Vi -- Vs -- wa (Ps -- Ps) Bi=8-546_^144rVfli0i(161"60) = 8.546 - 3.407 = 5.139 fps The orifice diameter can now be found from Equa tion (42). " The kinetic energy corresponding to the reduced velocity' u, is, by Equation (12b) W,= 43.1 X 0.347 X 11,500 2X32.2 X 5.1392 = 70,529 ft-lb The energy stored in the pipe at the instant of maxi mum surge, by Equation (31b), is _ _ 10,368 X 3990.5 X 32.2/250 - 60V __ 52 ---------- 3189^X43.1------- \~~2-) ~ 27,410 ft'lb Assuming atmospheric pressure of 14 psia and a value for n of 1.015, solution for the required MagniLastic suppressor capacity by Equation (33b) yields: LG?). .Co = 144X74 0.015 70,529 - 27,410 C,, = 7.335 cu ft The suppressor should be precharged to pressure p-.t: 60 psig. Pulsation Control in Reciprocating Pump Lines If it is assumed that the velocity and hence the instantaneous quantity of the fluid discharged by a simplex reciprocating pump varies almost sinusoid ally with respect to time or angle of crank rotation it is apparent that this instantaneous flow rate is alternately less and greater than the mean flow rate. The mean flow rate may be defined as the product of the total quantity of fluid discharged during a 360 rotation of the cranks and the number of revo lutions of the cranks per unit of time. Making the pump double-acting or increasing the number of cylinders results in a less widely fluctuating quan tity-time curve since the velocity of one piston will be increasing during the interval that the velocity of another is decreasing. Obviously the flow rate variations would approach zero as a limiting value as the number of equally spaced cranks was infi nitely increased. Since there are practical limits to the number of cylinders employed in reciprocating pumps, the variations from the mean flow rate must be removed by other means. An air chamber of ade quate capacity located at the discharge of the pump has been proven effective in eliminating volumetric --and hence pressure--fluctuations in countless in stallations. Diederichs and Pomeroy (Ref. 14) de termined from considerable investigation that, ". . . The intelligent application of air chambers at the pumps absolutely prevented the setting up of surges." They point out certain limitations inherent in the design and use of air chambers. Among these are the gradual loss of the pressurizing air which is ab sorbed by the liquid, loss of air in the chamber when the system pressure drops below the design operat ing pressure, and the formation of an explosive mix ture when the air unites with hydrocarbon vapors in a system handling petroleum derivatives. These shortcomings are completely overcome in the design of the MagniLastic Hydropad, since the diaphragm bellows keep the gas and liquid sepa rated at all times and prevent the loss of the gas when the system pressure is reduced below its nor mal operating level. Hydropads are precharged with inert nitrogen gas, which will not support combus tion. In order to determine the correct capacity of the suppressor to be used to accommodate the volume of liquid pumped in excess of that flowing through the associated piping system at the mean flow rate, it will first be necessary to examine the flow charac teristics of the system. If a constant back pressure p,, is maintained, the pump, equipped with a surge suppressor, and operating between the pressure limits pT and p,,,, where (px+pm)/2 = p0, will fur nish fluid at its rated mean flow Q,,. If the back pres sure effective at the pump is maintained by pipe friction with or without flow controlling devices, this pressure p0 will equal the mean discharge pressure at the pump at the mean flow rate Qn. Let pm be the maximum allowable surge pressure. When a portion of the liquid is at pressure pm its instantaneous flow rate becomes Qm > Q,,. Because over the period of one cycle the pump is delivering fluid at the mean rate Q0, during a portion of this cycle the instanta neous rate will be reduced to Qs, where Q,, ~Qx -- Qm -- Qo- If the reduced system pressure which im pels a flow of Qx is px, the approximate pressure relationship becomes p,,, -- p,, = p,, -- ps. Assuming, then, that p is known or can be calculated and the allowable pressure rise pm--p,, is specified, the ca pacity of the required suppressor can be determined from application of Formulas (35) and (36) and a knowledge of excess volume relationships for recip rocating pumps of various types. Since pressure fluctuations, created by every pis ton stroke, may occur rapidly--at frequencies of one or more cycles per second--the cushioning gas within the suppressor will be compressed and expanded nearly adiabatically. A value of 1.4 for n should thus be employed for nitrogen-charged suppressors. The pressure relationship is Ps = 2p0 - Pm psi (47) in which pr = minimum operating pressure, psig Ps = suppressor charging pressure [35] p0 = design operating pressure, psig pm = maximum allowable pressure, psig Using the starred symbols p,, Po, Pm for absolute values of the corresponding gauge pressures px, p0 and pm, the required capacity Cx is given by 0.7854F1b2s: Cx = - cu m. -<&r (48) where F3 = the conservative pump volumetric fac tor listed in the table below b = bore of one cylinder, inches Si = stroke of one piston, inches n = polytropic exponent of gas expansion n = 1.4 for nitrogen pressurized suppressors. Numerical values for i will be found in Fig. 27. Reciprocating Pump Volumetric Factor Table Pump Type Simplex single-acting Simplex double-acting Duplex single-acting Duplex double-acting Triplex single-acting Triplex double-acting Quadruplex single-acting Quadruplex double-acting Quintuplex single-acting Quintuplex double-acting Sextuplex Septuplex Factor F, 0.60 0.25 0.25 0.15 0.03 0.06 0.10 0.06 0.06 0.02. 0.06 0.02 The suppressor should be precharged to the pres sure px. Since the present application of suppressors is based on purely volumetric instead of energy con siderations, the use of orifices to limit the flow is not justified. A second suppressor should be installed in the pump suction line to serve as an accumulator in pre venting separation of the liquid column if the pump is operating with a static lift or if the volumetric variation factor F1 is 0.25 or greater. For static lift applications, Po = design operating suction pressure, psia po = (atmospheric pressure)-(vapor pressure)- (static lift)-(pump entrance losses)-(pipe friction losses) pxe = minimum allowable suction pressure, psia px = suppressor charging pressure pm = 2p0 --Px psia (47a) [36] Solution for the required capacity Cx can then be made by the use of Equation (48). Example: find the capacity of the MagniLastic suppressor required to limit the pressure rise p,,, p,, of a 6X24 duplex double-acting pump to 25 psi for a design operating pressure p of 700 psig. Solution: assume atmospheric pressure p,, -- 14.5 psia. The pressures are Po = 700 psig Po = 714.5 psia Pm = Po + Pr -- 700 + 25 = 725 psig Pm = 739.5 psia Px = 2po -- pm = 2 X 700 -- 725 = 675 psig Px9 = 689.5 psia From the volumetric factor table above, Fj for a duplex double-acting pump is 0.15 b = 6-inch bore S'i = 24-inch stroke n = 1.4 By Equation (48) the capacity, 0.714 0.7854 X 0.15 X 62 X 24 (--^ Cx = 1 \739.5/ Cx -- 4315 cu in. Resonance ' If a series of periodic pressure pulsations traveling the length of a pipe line at approximately the sonic velocity a is reflected from a "closed end" in such a way that the reflected waves are in phase with the incident waves, stationary or standing waves are formed, and the resulting constructive interference greatly increases the amplitude of particle displace ment. Pressure fluctuations are correspondingly magnified. Parts of the medium separated by onehalf a wave length experience opposing tendencies which cancel each other's effects, while at points midway between these regions the tendencies toward displacement are reinforced. The former re gions are designated nodes; the latter antinodes or loops. The characteristic of a "closed end" in a pipe line may be produced by a partially closed valve, an orifice, a reducer, or a dead-end branch. Reflections will also occur at an "open end," pro duced by an enlarged pipe section of at least twice the flow area or by the presence of a component in which the mean flow velocity is less than half that prevailing in the supply pipe. Reflections from an "open end" undergo a phase shift of 180. The inci dent wave is thus reflected with a change of sign. It was previously stated that the pressure wave traveled at approximately the sonic velocity a. For practical purposes in the frequency range generated by reciprocating pumps the use of a calculated value of a from Equation (14) will be sufficiendy accurate without further modification. For a further discus sion of wave velocity variation and energy distri bution the reader is referred to Thomson's paper (Reference 15). Fluid temperature is a highly important factor in determinations of the pressure wave velocity. A tem perature rise will decrease both the specific weight w and the bulk modulus k of some liquids. The re sultant change in a is about --0.088% per degree F, referred to a base temperature of 60 F, and applicable to all hydrocarbons. The negative sign indicates a decrease in the value of a with an in crease in temperature. The wave length A. of the fundamental standing wave produced in a pipe line by a reciprocating pump whose frequency is i pulsations per second and in which the flow velocity is negligible in com parison with the velocity a is, from wave mechanics: \ = -- ft i (49) From a consideration of resonance in closed and open pipes the conditions conducive to resonance may be stated. The length of a closed pipe--or sec tion of pipe line terminating in a "closed end" as defined above--which will resonate is Lr 2_--r ft (50) where Mi is any odd integer. Similarly the length of an open pipe--or section of pipe line terminating in an "open end"--which will resonate is where M is any integer, even or odd. It may be shown that the pump represents a par ticle displacement antinode in the analysis of reso nant conditions; a closed end can only permit the formation of a node; an open end will support an antinode. Calculations based on Formulas (50) or (50a) will disclose the tendency of the system to resonate. Maximum resonance and the formation of standing waves will occur if L = L2 or L3. Beats, or the alternate reinforcement and cancellation of pres sure waves may occur if L is from 90% to 110% of L2 or Ls- Various attempts to reduce the amplitude of standing waves in reciprocating pump systems have been made from time to time. The problem has been aggravated by the use of higher speed pumps arid drivers and the replacement of steam engines by diesel engines, since the advantages of a steamcushioned stroke are no longer provided. Following the analysis and admirable solution presented by J. W. Squire (Ref. 16) a basic study of pipe line pulsation was initiated at Oklahoma A & M College, Stillwater, Oklahoma. A report (Ref. 17) covering the first phase of the project and presenting a wellformulated electrical analogy for the manipulation of hydraulic parameters has been released by the sponsoring pipe line companies. R. C. Binder (Ref. 18) develops a method of analysis along similar lines. MagniLastic suppressors designed for pulsation control have proven effective in a wide variety of applications and over the complete frequency and pressure range required by all pumps in current use. Since each system is unique no further general an alysis would be pertinent here. Inquiries regarding suppressor applications for pulsation and resonance control should be addressed to MagniLastic Divi sion, Cook Electric Company, 2700 Southport Ave nue, Chicago 14, Illinois. Accumulators In hydraulic systems an accumulator converts ex cess fluid and compressed gas into stored energy, available upon demand. The basic criteria for de termining the needed capacity of an accumulator include: V/ the volume of fluid displaced, or usable volume, cu in. po the minimum allowable accumulator pres sure after the expulsion of the volume V/; also the accumulator precharging pressure, psia pm the maximum allowable accumulator pres sure, usually the system design operating pressure, psia The minimum required capacity c0 at pressure p0 can be found directly from a rearrangement of For mula (35): [37] If the accumulator is to be precharged to some absolute pressure px <P(i, the minimum required capacity cT of the accumulator supplying the volume V/ of liquid between the pressure limits pm and Po" is TM (i C.T -- ' cu m. (35b) will be distributed between the volume displaced in the suppressor (VL--VC) and the increment of volume stored in the pipe V,, and since the gas in the suppressor will be compressed adiabatically (n = 1.4) the required suppressor capacity C0 may be found by combining and rearranging Equations (18) and (35). C0 (Vl-Vc)-V, CU ft 0.714 (54) Numerical values for " and " will be found in Fig. 27. MagniLastic accumulators, employing superior stainless steel bellows construction, are designed in strict accordance with government specifications, and are available in all standard capacities. Thermal Expansion Compensation If both ends of a pipe line filled with liquid are closed and the line is-subjected to a temperature increase from f(, to fi F, both pipe and liquid will expand volumetrically. Since the coefficient of ex pansion for most liquids is much higher than that for most conduit materials, and since no liquid can escape from the system the additional volume re quired will produce a pressure increase pi -- po as given by Equation (18) where V0 and Vj are the initial and net expanded volumes, respectively, in cubic feet: pi-p,,=-(VrjW--V0g)a-w . psi (18) Designating by g the effective value of the cubi cal expansion of the liquid per F from the base temperature f(1. and by gc the effective coefficient of linear expansion of the conduit material per F from the base temperature f,,, the volumetric increases resulting from a temperature rise from ta to F, may now be written. For the liquid: Vr. -- V0 = Vog/.(ti--to) cu ft (51) For the conduit, since the coefficient of cubical ex pansion very nearly equals 3ge: V(. -- V0 = 3V,,gc(f1 --10) cu ft (52) The resulting net excess volume is Vi-Vc-V,,8i(f1-t,,) ~3V0ge(ti--10) Vl~ Vc = V0(ti--f0)(g.-- 3gc) cuft (53) Accommodation of this excess volume may be provided by the inclusion of a suppressor or accu mulator in the system. Since the net excess volume [38] where V,, = 144ALg(pi -- po)/a,2wt cu ft (55) Po and p,, are the initial gauge and absolute pres sures, respectively, psi, at temperature to; also suppressor charging pressure Pi and pi * are the gauge and absolute pressures, respectively, psi, to which the system is allowed to rise at temperature t\ at is the velocity of the pressure wave at tempera . ture fi, fps wt is the specific weight of the liquid at tempera ture fi, lb/cu ft w0 is the specific weight of the liquid at 60/60F. Numerical values of 1.4 will be found in Fig. 27. For low values of the pressure rise [ (pi --pn) <50 psi] the quantity Vp may be neglected. It is obvious that neither p0 nor pi" can be less than the vapor pres sure of the liquid at the corresponding temperatures to and t\* Example: determine the accumulator capacity re quired to limit the pressure increase from zero psig at 60F to 50 psig at 120F, in a closed system con sisting of 100 feet of 8-inch schedule 40 steel pipe and containing gasoline with a specific gravity at 60/60F of 0.75. ' Solution: V0 = AL = 0.347 X 100 = 34.7 cu ft eL (from Table III) = 0.0006 per F so (fromTable IV) = 0.00000583 per F fi --fo = 120 -60 = 60 VL - Vc = 34.7 X 60 (0.0006 - 3 X 0.00000583) Vi - Vc = 1.213 cu ft , _ Wo _ 0.75X62.4 ` 1--8i(ti--fo) 1-0.0006X60 wt = 45.2 Ib/cu ft kt (from Fig. 35) = 96,000 psi a, = V 32.2 12 7.981 96,000-4- 0.322 X 30,000,000; at = 3026 fps V,, = 144 X 34.7 X 32.2 X 50 30262 X 45.2 = 0.019 cu ft The required capacity C0 can now be found from Equation (54): Co 1.213-0.019 1.83 cu ft Hydraulic Energy Balance From a theoretical standpoint the energy balance related to hydraulic surge consists of equating the energies present in the system plus those added to the system during the time interval from the com pletion of valve closure until the instant of mavimnm surge to the energies stored elastically at the in stant of maximum surge and the energy dissipated through heat transfer. The energy balance can thus be written Wo + yT+ 144ppAV + E; = a + 8+ Heat (56) To the kinetic energy: Wo = wALvU'72g ft-lb (12) is added the flow work of the liquid entering the system between the time of complete valve closure and the instant of maximum surge. Part of this liquid enters the suppressor. The energy associated with this quantity is yT (theoretical): yr = 144Vdp0 ft-lb (57) From Equation (35) an expression for Vi is ob tained, and yr=144p0Co[l- (^1) ] ft-lb (58) This formula is identical to (29) except that p0 is used in lieu of po. The remainder of the liquid added to the system after valve closure enters the transfer pipe, keeping it full. Its volume is AV cubic feet, and its energy is 144ppAV ft-lb. The quantity AV can be calcu lated only if the time interval of fluid deceleration is known. Since this time interval depends upon line length, suppressor capacity and orificing it cannot be predetermined with any degree of accuracy. The fourth term on the left side of Equation (56) is the energy added from regained friction head. If the maximum recovered pressure is (pp--p0)/V2-- refer to Formula (17)--the average recovered pres sure along the pipe, assuming linear pressure dis tribution, will be (p,,--p0)/2V2l The energy re gained is E/, where V is the total volume of fluid in the pipe (cubic feet) E;= 144V(Pp~Po) ft.ib 2"\/ 2 (59) At the instant of maximum surge some of the en ergy will be stored in the compressed gas of the suppressor, some will be stored elastically in the compressed liquid and expanded pipe, and some will have been lost by heat transfer. From thermodynamics the energy a stored in a volume C0 of a gas between die pressure limits pn and pra is * = 14^iy.q. [(^4)"" l] ft-lb (30) If it is assumed that at the instant of maximum surge the pressure along the pipe varies linearly from pm at the valve to pp at the pump, the average pressure rise, Ap is given by the expression. Ap = (p,,,+pp)/2- (pp+p,,)/2 .'. Ap = (pra-po)/2 psi From Equation (9b) (60) (==!)= ft.it (31) The heat transferred through the conduit walls will vary with the fluid temperature, ambient tem perature, air circulation, surge cycle duration, sys tem friction characteristics and rate of energy con version. Though small in comparison with the other terms it cannot be neglected. The inference may be drawn that the terms "144ppAV" and "Heat" in Equation (56) cannot be predetermined with any degree of accuracy. A very close approximation to the true energy balance is obtained by rewriting Equation (56) in the form Wo + yT + (144ppAV + E,~ Heat) = + S (56a) The terms within the parenthesis are substantially accounted for by the use of p0 in the term y to replace p0 in yr y = 144poC0 [ 1 - (g-1)'] . ft-lb (29) This substitution yields results within five percent of measured values for all test runs when employed in the modified energy balance Wo + y = a + 8 ft-lb (32) [39] W0'. (I) FT-LB/FT. Qo 6 PM 200 -g 40,000 --g 100 10*000 g| 50 5,000 HE 20 -3 2,000 -i 1,000^- ' ~500 -- 2 --9 0.5 -- 0.2 -H 0.1 . 0.05 -3 200 --= 100^ 50 20 -j 10^ 5-- Wo 1 2 2 0.02 0.01 0.005 j0.6 - -- 0.002 04 0.001 w S.6. LB./CU.FT. 1.6- 100 vo FPS 1.5 1.5-S' -90 1.4-is 1.3-El 80 0.7-- - 40 0.6 --3EI 4-- 5--_ 6-- 0.5 30 15 H 04-X_ 25 20 -H 25 -1 Fig. 33. Nomograph for Kinetic Energy Per Unit Length Corresponding points on the v0, d (or A), Q0 and reference axis (1) will lie in a straight line. A sec ond straight line connects the reference intercept with w and the required solution W0'. In the exam ple provided (dashed lines) water is flowing at 1000 gpm through 13.124-inch I.D. pipe. Find W0' the kinetic energy per unit length. Solve by connecting 1000 on Qo with 13.124 on d. Extend this line to intersect with reference axis (1) and axis t>0- For reference read 2.37 fps (flowing velocity) on o0* Connect the intercept on reference axis (1) with 62.4 on tv and read 5.1 ft-lb/ft on the W0' axis. [40] cl ol ! 111ill dA IN. SQ. FT. 60- 20 (I) -->o 30 fc-5 220-i 10: 0.5 8* 6"lr0-2 Ji-- 0.1 :r 0.05 2 -r- 0.02 "Efc-o.oi 0.005 0.8 ' 0.6 -jb- 0.002 Q4 _E -- 0.001 Ws = 10,368 Ag a2w (P. "pof 10,368 Ag 8'= a2w (2) Ws or S FT-LB/FT 1000 !- 500 r 200 r-100 r 50 - 20 r 5* r 05 r0.2- r- 0.1 r 0.05 - 0.02 -- 0.01 =- 0.005 - 0.002 -- 0.001 (F'-P0)r(5l!^) w a PS I 500--a S.G. LB/CU.FT FPS 04 i 25 ' 2000' J 200- -30 0.5 -- 100-d 50 -9 2500H 0.6 -t jP-40 --0.7- if- 3000H 20--: 10-= 0.8 I-- 0.9 r 3500 -- 60 1.0 ] " o.oooi r- 0.00001 h 0.000001 r* -- t- 0.0000001 5-^j 2--= 1-- : 4000-- l.l -70 ~ 1.2 : 1 /80 _j jj 1.3 : 4500^ 1.4 1-90 ^ 15 i 5000 : 1.6 100 Fig. 34. Nomograph for Elastic Energy Per Unit Length The nomograph solves the relations for W8' or 5' depending upon the selection of the pressure factor (Pi--po) or (pm--p0)/2. An example is provided by the dashed lines. Given data: a = 3189 fps; w = 43.1 lb/cu ft; A = 0.347 sq ft; pm -- 250 psig; p0 = 60 psig. Find 8'. Solution: find the pressure factor, (pm--p0)/2 = (250-- 60)/2 = 95 psi. Now lay a straightedge from 0.347 on the A axis to 43.1 on w. Mark the inter section with reference axis (1). Connect this point with 3189 on a and mark a new intercept on refer ence axis (2). Connect the latter point with 95 on (p,,,--p0)/2 and read 2.4 ft-lb/ft on S'. [41] [42] Fig. 35. Bulk Modulus of Hydrocarbons 62.45 [43] TABLE I Conversion Factors and Formulas Psi 0.4331 X (head in feet of liquid) X (specific Gallons per minute = 0.029167 X (barrels per day) gravity) lb/sec = w X (CFS) Psi = 0.0361 X (head in inches of liquid) X (specific gravity) Psi = 0.491 X (head or vacuum inches of mercury) lb/sec=0.002228to X (GPM) 141.5 Degrees API= Sp Gr 60/60F " 181-5 Psi = 0.01934 X (head or vacuum, mm. of mercury) Jet velocity, v(FPS) = V2gh, where h = head in feet Psi = 14.7 X (atmospheres) Psi = 14.22X (Metric atmospheres: kg/sq cm) Gallons = 7.481 X (cubic feet) Cubic inches=1728 X (cubic feet) =231X (gallons) Cubic inches = 0.061024 X (cubic centimeters) Cubic feet = 0.13368 X (gallons) Velocity head, h(ft) =v2/2g Bernouilli's Theorem hi + Z] + Ui2/2g = ha + Zo + v2/2g where Zi and Z2 are elevations (ft) above datum Friction loss in pipes h, = fLv-/2Dg Barrels = 42X (gallons) in which hf = head loss in feet of liquid flowing Cubic feet per second = 0.002228 X (GPM) f = friction factor, from Fig. 32 Gallons per minute = 449 X (CFS) L = pipe length, ft Gallons per minute = 0.7 X (barrels per hour) D = inside diameter of pipe, ft [44] TABLE II Viscosity Conversion Factors A. CONVERSION FACTORS FOR DYNAMIC VISCOSITY Multiply POISE gm mass cm-sec or dyne-sec sq cm CENTIPOISE th />> REYNS gm mass cm-sec slugs ft-sec lb-mass ft-sec or or or dyne-sec sq cm lb force-sec lb force-sec pdl-sec sqft sq in sqft By To Obtain POISE i CENTIPOISE th /*! slugs ft-sec REYNS lb mass ft-sec 100 2.088 X10-* 1.45 X10-" 0.0672 0.01 1 2.088 x 10~s 1.45 x 10"7 6.72 X10-4 478.8 47,880 1 6.95 X10-1 32.17 6.895 xl0` 6.895 x 10* 144 14.88 1,488 0.03108 1 4,637 2.16 X10-4 1 B. RELATIONSHIP BETWEEN DYNAMIC AND KINEMATIC VISCOSITY Dynamic viscosity = Kinematic viscosity x specific gravity vw or* = 62A where th = dynamic viscosity, centipoise v = kinematic viscosity, centistokes w = specific weight, Ib/cu ft C. CONVERSION FACTORS FOR KINEMATIC VISCOSITY: FROM VARIOUS UNITS TO CENTISTOKES () y = sq ft/sec X 92,900 y = stokes x 0.01 For viscometer readings of ? seconds: v = 0.220t -- 135/? for Saybolt Universal when ? > 100 r=0.226? -- 195/f for Saybolt Universal when 32 < ? < 100 r-- 2.16?--60/i for Saybolt Fnrol when t > 40 v = 2.24? --184/? for Saybolt Furol when. 25 < f < 40 r=0.247?--50/? for Redwood No. 1 when ? > 100 r = 0.260? --179/? for Redwood No. 1 when 34 < ? < 100 >'=2.7?--2000/? for Redwood Admiralty =0.147? -- 374/? for Engler degrees [45] TABLE III Properties of Liquids (At Base Temperature 60F) to Specific Weight lb/cu ft k Bulk Modulus psi v or lh Viscosity centistokes or centipoise FL Coefficient of Volumetric Expansion per F Multiply by 10"J Ammonia (Saturated) (at--28F) Ethyl Alcohol (100%) Hydrazine (100%) Mercury Nitric Acid (Red or White Fuming) Nitrogen (Liquid) (at --321F) 42.3 49.4 63.2 849 96 50 392,000 131,000 3,900,000 0.24 cp 1.35 cp 1.02 cp 1.55 cp 414,000 1.13 cp 968,000 62 10 78 Oxygen (Liquid) (at--298F) 71.35 0.19 cp Petroleum Derivatives "'S. G. Range 60/60F 0.6112-0.6275 0.6276- 0.6417 0.6418 - 0.6722 0.6723 - 0.7238 `"0.7239 - 0.7753 0.7754 - 0.8498 0.8499 - 0.9659 0.9660-1.0760 Fresh Water Sea Water 38.1-39.2 39.2-40.0 40.0-41.9 41.9-45.2 45.2-48.4 48.4-53.0 53.0 - 60.3 ' 60.3 - 67.1 See Fig. 36 63.99 See Fig. 35 0.30 cs`" 0.64 cs"' 0.84 cs`" 2.6 cs"' 14.2 cs`" See Fig. 36 312,000 1.1 cp 1.2 cs 90 85 80 70 60 50 40 35 11.5 23 NOTES: men """ '' Wt- of 8iven volume of oil at 60F Wt. of equal volume of water at 60 F (Both weights corrected for buoyancy of air) All blends of gasoline and benzene are considered to fall in this group Value for 0.6 S.G. butane <*> Value for 0.69 S.G. gasoline, Grade 115-145 (5) Value for 0.76 S.G. gasoline , <> Value for 0.815 S.G. kerosene Value for 0.9 S.G. fuel oil [46] TABLE IV Properties of Conduit Materials (At Base Temperature 60F) Material E 8c Young's Modulus psi (Multiply Coefficient of Linear Expansion per F Density lb/cuin. by 10*) (Multiply by 10~*) Yield Stress psi (Multipl by 10f) Aluminum 2 S-O 3 S-O 61S-T6 63S-T6 Brass (Red) Copper (Deoxidized) Cast Iron Carbon Steel Stainless Steel 10 10 10 10 13 18 14 28-30 13.1 12.9 13.1 13.0 10.4 9.8 6 5.83 0.098 0.099 0.098 0.098 0.316 0.323 0.261 0.308 5 6 40 30 14-20 8-10 12-25 Type 304 28 9.6 0.29 30" Type 316 28 8.9 0.29 30" Type 321 28 9.3 0.29 30" Type 347 28 9.3 0.29 - 35" Refueling Hose" 0.125-0.225 "Annealed ""Collapsible and non-collapsible: 3 in. and 4 in. diameter; d/e 6--9 Nominal Pipe Size-In. H a % x % 1 in 18 2 28 3 38 4 5 6 8 10 [48] TABLE V Dimensions of Seamless and Welded Steel Pipe Outside Diam. In. 0.405 0.540 0.675 0.840 1.050 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500 5.563 6.625 8.625 10.750 Schedule No. 40 ST 80 XS 40 ST 80 XS 40 ST 80 XS 40 ST 80 XS 160 XX 40 ST 80 XS 160 XX 40 ST 80 XS 160 XX 40 ST 80 XS 160 XX 40 ST 80 XS 160 XX 40 ST 80 XS 160 XX 40 ST 80 XS 160 XX 40 ST 80 XS 160 XX 40 ST 80 XS XX 40 ST 80 XS 160 XX 40 ST 80 XS 160 XX 40 ST 80 XS 160 XX 20 40 ST 80 XS 120 XX 160 20 40 ST 60 XS 80 120 160 Wall Thickness In. 0.068 0.095 0.088 0.119 0.091 0.126 0.109 0.147 0.187 0.294 0.113 0.154 0.218 0.308 0.133 0.179 0.250 0.358 0.140 0.191 0.250 0.382 0.145 0.200 0.281 0.400 0.154 0.218 0.343 0.436 0.203 0.276 0.375 0.552 ' 0.216 0.300 0.438 0.600 0.226 0.318 0.636 0.237 0.337 0.531 0.674 0.258 0.375 0.625 0.750 0.280 0.432 0.718 0.864 0.250 0.322 0.500 0.718 0.875 0.906 0.250 0.365 0.500 0.593 0.843 1.125 Inside Diam. In. 0.269 0.215 0.364 0.302 0.493 0.423 0.622 0.546 0.466 0.252 0.824 0.742 0.614 0.434 1.049 0.957 0.815 0.599 1.380 1.278 1.160 0.896 1.610 1.500 1.337 1.100 2.067 1.939 1.689 1.503 2.469 2.323 2.125 1.771 3.068 2.900 2.624 2.300 3.548 3.364 2.728 4.026 3.826 3.438 3.152 5.047 4.813 4.313 4.063 6.065 5.761 5.189 4.897 8.125 7.981 7.625 7.189 6.875 6.813 10.250 10.020 9.750 9.564 9.064 8.500 Flow Area Sq Ft . 0.0004 0.0003 0.0007 0.0005 0.0013 0.0010 0.0021 0.0016 0.0012 0.0003 0.0037 0.0030 0.0020 0.0010 0.0060 0.0050 0.0036 0.0020 0.0104 0.0089 0.0073 0.0044 0.0141 0.0123 .0.0097 0.0066 0.0233 0.0205 0.0156 0.0123 0.033 0.029 0.025 0.017 0.051 0.046 0.038 0.029 0.069 0.062 . . 0.041 0.088 0.080 0.064 0.054 0.139 0.126 0.101 0.090 0.201 0.181 0.147 0.131 0.360 0.347 0.317 0.282 0.256 0.253 0.573 0.548 0.518 0.499 0.448 0.394 TABLE V (continued) Dimensions of Seamless and Welded Steel Pipe Nominal Pipe Size-ln. Outside Diam. In. Schedule No. Wall Thickness In. Inside Diam. In. Flow Area Sq Ft 12 12.750 20 0.250 12.250 0.819 ST 0.375 12.000 0.785 40 0.406 11.938 0.777 80 XS 0.500 11.750 0.753 120 1.000 10.750 0.631 160 1.312 10.126 0.559 14 14.000 10 0.250 13.500 0.994 20 0.312 13.375 0.976 30 ST 0.375 13.250 0.958 40 0.438 13.124 0.940 XS 0.500 13.000 0.921 80 0.750 12.500 0.852 100 0.937 12.125 0.802 160 1.406 11.188 0.683 10 0.250 15.500 1.310 20 30 ST 40 XS 0.312 0.375 0.500 15.375 15.250 15.000 1.290 1.269 1.227 60 0.656 14.688 1.176 80 0.843 14.314 1.117 120 1.218 13.564 1.003 160 1.593 12.814 0.896 18 18.000 10 0.250 17.500 1.670 20 0.312 17.375 1.646 ST 0.375 17.250 1.623 XS 0.500 17.000 1.576 40 0.562 16.876 1.553 60 0.750 16.500 1.485 100 1.156 15.688 1.342 160 1.781 14.438 1.137 20 20.000 10 0.250 19.500 2.073 - 20 ST 0.375 19.250 2.021 30 XS 0.500 19.000 1.969 40 0.593 18.814 1.930 80 1.031 17.938 1.755 -. 160 1.968 16.064 1.408 24 24.000 10 0.250 23.500 3.014 20 ST ' 0.375 23.250 2.951 XS 0.500 23.000 2.882 40 0.687 22.626 ' 2.791 80 1.218 21.564 2.535 160 2.343 19.314 2.035 30 -- 30.000 10 20 30 0.312 0.500 0.625 29.376 29.000 28.750 4.708 4.590 4.507 [49] N. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 N. [50] TABLE VI FOUR PLACE LOGARITHMS 0 1 .2 3 4 56789 0000 0414 0792 1139 1461 1761 2041 2304 2553 2788 3010 3222 3424 3617 3802 3979 4150 4314 4472 4624 4771 4914 5051 5185 5315 5441 5563 5682 5798 5911 6021 6128 6232 6335 6435 6532 6628 6721 6812 6902 6990 7076 7160 7243 7324 0 0043 0453 0828 1173 1492 1790 2068 2330 2577 2810 3032 3243 3444 3636 3820 3997 4166 4330 4487 4639 4786 4928 5065 5198 5328 5453 5575 5694 5809 5922 6031 6138 6243 6345 6444 6542 6637 6730 6821 6911 6998 7084 7168 7251 7332 1 0086 0492 0864 1206 1523 1818 2095 2355 2601 2833 3054 3263 3464 3655 3838 4014 4183 4346 4502 4654 4800 4942 5079 5211 5340 5465 5587 5705 5821 5933 6042 6149 6253 6355 6454 6551 6646 6739 6830 6920 7007 7093 7177 7259 7340 2 0128 0531 0899 1239 1553 1847 2122 2380 2625 2856 3075 3284 3483 3674 3856 4031 4200 4362 4518 4669 4814 4955 5092 5224 5353 5478 5599 5717 5832 5944 6053 6160 6263 6365 6464 6561 6656 6749 6839 6928 7016 7101 7185 7267 7348 3 0170 0569 0934 1271 1584 1875 2148 2405 2648 2878 3096 3304 3502 3692 3874 4048 4216 4378 4533 4683 4829 4969 5105 5237 5366 5490 5611 5729 5843 5955 6064 6170 6274 6375 6474 6571 6665 6758 6848 6937 7024 7110 7193 7275 7356 4 0212 0607 0969 1303 1614 1903 2175 2430 2672 2900 3118 3324 3522 3711 3892 4065 4232 4393 4548 4698 4843 4983 5119 5250 5378 . 5502 5623 5740 5855 5966 6075 6180 6284 6385 6484 6580 6675 6767 6857 6946 7033 7118 7202 7284 7364 0253 0645 1004 1335 1644 1931 2201 2455 2695 2923 3139 3345 3541 3729 3909 4082 4249 4409 4564 4713 4857 4997 5132 5263 5391 5514 5635 5752 5866 5977 6085 6191 6294 6395 6493 6590 6684 6776 6866 6955 7042 7126 7210 7292 7372 0294 0682 1038 1367 1673 1959 2227 2480 2718 2945 3160 3365 3560 3747 3927 4099 4265 4425 4579 4728 4871 5011 5145 6276 5403 5527 5647 5763 5877 5988 6096 6201 6304 6405 6503 6599 6693 6785 6875 6964 7050 7135 7218 7300 7380 0334 0719 1072 1399 1703 1987 2253 2504 2742 2967 3181 3385 3579 3766 3945 4116 4281 4440 4594 4742 4886 5024 5159 5289 5416 5539 5658 5775 5888 5999 6107 6212 6314 6415 6513 6609 6702 6794 6884 6972 7059 7143 7226 7308 7388 0374 0755 1106 1430 1732 2014 2279 2529 2765 2989 3201 3404 3598 3784 3962 4133 4298 4456 4609 4757 4900 5038 5172 5302 5428 5551 5670 5786 5899 6010 6117 6222 6325 6425 6522 6618 6712 6803 6893 6981 7067 7152 7235' 7316 7396 56789 Proportional Parts 1 2345 4 8 12 17 21 4 8 11 15 19 3 7 10 14 17 3 6 10 13 16 3 6 9 12 15 3 6 8 11 14 3 5 8 11 13 2 5 7 10 12 2 5 7 9 12 2 4 7 9 11 2 4 6 8 11 2 4 6 8 10 2 4 6 8 10 24579 24 5 7 9 23579 23578 23568 23568 1 3467 1 3467 1 3467 1 3457 1 34 5 6 1 34 5 6 1 2 4 5' 6 12456 12356 12356 1 2 3- 4 6 12345 1 2 34 5 12345 12345 1 2 345 1 2 34 5 1 2 345 12345 1 2344 1 2 344 1 2 3 34 1 2 3 34 1 2234 12234 12234 1 2 345 FOUR PLACE LOGARITHMS (continued) N. 0 1 2 3 4 56789 Proportional Parts 1 2 345 55 7404 7412 7419 7427 7435 7443 7451 7459 7466 7474 1 2 2 3 4 56 7482 7490 7497 7505 7513 7520 7528 7536 7543 7551 1 2 2 3 4 57 7559 7566 7574 7582 7589 7597 7604 7612 7619 7627 1 22 34 58 7634 7642 7649 7657 7664 7672 7679 7686 7694 7701 1 1 2 3 4 59 7709 7716 7723 7731 7738 7745 7752 7760 7767 7774 1 1234 60 7782 7789 7796 7803 7810 7818 7825 7832 7839 7846 1 1234 61 7853 7860 7868 7875 7882 7889 7896 7903 7910 7917 1 1 2 3 4 62 7924 7931 7938 7945 7952 7959 7966 7973 7980 7987 1 1 2 3 3 63 7993 8000 8007 8014 8021 8028 8035 8041 8048 8055 1 1 2 3 3 64 8062 8069 8075 8082 8089 8096 8102 8109 8116 8122 1 1 2 3 3 65 8129 8136 8142 8149 8156 8162 8169 8176 8182 8189 1 1233 66 8195 8202 8209 8215 8222 8228 8235 8241 8248 8254 1 1 2 3 3 67 8261 8267 8274 8280 8287 8293 8299 8306 8312 8319 1 1 2 3 3 68 8325 8331 8338 8344 8351 8357 8363 8370 8376 8382 1 1 2 3 3 69 8388 8395 8401 8407 8414 8420 8426 8432 8439 8445 1 1233 70 8451 8457 8463 8470 8476 8482 8488 8494 8500 8506 1 1 2 2 3 71 8513 8519 8525 8531 8537 8543 8549 8555 8561 8567 1 1223 72 8573 8579 8585 8591 8597 8603 8609 8615 8621 8627 1 1223 73 8633 8639 8645 8651 8657 8663 8669 8675 8681 8686 1 1223 74 8692 8698 8704 8710 8716 8722 8727 8733 8739 8745 1 1 2 2 3 75 8751 8756 8762 8768 8774 8779 8785 8791 8797 8802 1 1 2 2 3 76 8808 8814 8820 8825 8831 8837 8842 8848 8854 8859 1 1 2 2 3 77 8865 8871 8876 8882 8887 8893 8899 8904 8910 8915 1 1 2 2 3 78 8921 8927 8932 8938 8943 8949 8954 8960 8965 8971 1 1 2 2 3 79 8976 8982 8987 8993 8998 9004 9009 9015 9020 9025 1 1223 80 9031 9036 9042 9047 9053 9058 9063 9069 9074 9079 1 1 2 2 3 81 9085 9090 9096 9101 9106 9112 9117 9122 9128 9133 1 1223 82 9138 9143 9149 9154 9159 9165 9170 9175 9180 9186 1 1223 83 9191 9196 9201 9206 9212 9217 9222 9227 9232 9238 1 1 2 2 3 84 9243 9248 9253 9258 9263 9269 9274 9279 9284 9289 1 1 2 2 3 85 9294 9299 9304 9309 9315 9320 9325 9330 9335 9340 1 1 2 2 3 86 9345 9350 9355 9360 9365 9370 9375 9380 9385 9390 1 1 2 2 3 87 9395 9400 9405 9410 9415 9420 9425 9430 9435 9440 01 122 .88 9445 9450 9455 9460 9465 9469 9474 9479 9484 9489 01 122 89 9494 9499 9504 9509 9513 9518 9523 9528 9533 9538 01 1 22 90 9542 9547 9552 9557 9562 9566 9571 9576 9581 9586 01 1 22 91 9590 9595 9600 9605 9609 9614 9619 9624 9628 9633 01 122 92 9638 9643 9647 9652 9657 9661 9666 9671 9675 9680 01 122 93 9685 9689 9694 9699 9703 9708 9713 9717 9722 9727 01 122 94 9731 9736 9741 9745 9750 9754 9759 9763 9768 9773 0 1 1 2 2 95 9777 9782 9786 9791 9795 9800 9805 9809 9814 9818 01 122 96 9823 9827 9832 9836 9841 9845 9850 9854 9859 9863 0 1 1 2 2 97 9868 9872 9877 9881 9886 9890 9894 9899 9903 9908 01 122 98 9912 9917 9921 9926 9930 9934 9939 9943 9948 9952 0 1 1 2 2 99 9956 9961 9965 9969 9974 9978 9983 9987 9991 9996 01 122 N. 0 1 2 3 4 56789 1 2 345 [51] N. 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 1019 1020 102i 1022 1023 1024 1025 1026 1027 1028 1029 1030 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 N. [52] LOGARITHMS (continued) 01 234 000 0000 0434 0869 1303 1737 4341 4775 5208 5642 6076 8677 9111 9544 9977 *0411 001 3009 3442 3875 4308 4741 7337 7770 8202 8635 9067 002 1661 2093 2525 2957 3389 5980 6411- 6843 7275 7706 003 0295 0726 1157 1588 2019 4605 5036 5467 5898 6328 8912 9342 9772 *0203 *0633 004 3214 3644 4074 4504 4933 7512 7941 8371 8800 9229 005 1805 2234 2663 3092 3521 6094 6523 6952 7380 7809 006 0380 0808 1236 1664 2092 4660 5088 5516 5944 6372 8937 9365 9792 *0219 *0647 007 3210 3637 4064 4490 4917 7478 7904 8331 8757 9184 008 1742 2168 2594 3020 3446 6002 6427 6853 7279 7704 009 0257 0683 1108 1533 1959 4509 4934 5359 5784 6208 8756 9181 9605 *0030 *0454 010 3000 3424 3848 4272 4696 7239 7662 8086 8510 8933 Oil 1474 1897 2320 2743 3166 5704 6127 6550 6973 7396 9931 *0354 *0776 *1198 *1621 012 4154 4576 4998 5420 5842 8372 8794 9215 9637 *0059 013 2587 3008 3429 3850' 4271 6797 7218 7639 8059 8480 014 1003 1424 1844 2264 2685 5205 5625 6045 6465 6885 9403 9823 *0243 *0662 *1082 015 3598 4017 4436 4855 5274 7788 8206 8625 9044 9462 016 1974 2392 2810 3229 3647 6155 6573 6991 7409 7827 017 0333 0751 1168 1586 2003 4507 4924 5342 5759 6176 8677 9094 9511 9927 *0344 018 2843 3259 3676 4092 4508 7005 7421 7837 8253 8669 019 1163 1578 1994 2410 2825 5317 5732 6147 6562 6977 9467 9882 *0296 *0711 *1126 020 3613 4027 4442 4856 5270 7755 8169 8583 8997 9411 021 1893 2307 2720 3134 3547 56789 2171 65J0 *0844 5174 9499 3821 8138 2451 6759 *1063 2605 6943 *1277 5607 9932 4253 8569 2882 7190 *1493 3039 7377 *1710 6039 *0364 4685 9001 3313 7620 *1924 3473 7810 *2143 6472 *0796 5116 9432 3744 8051 *2354 3907 8244 *2576 6905 *1228 5548 9863 4174 8481 *2784 5363 9659 3950 8238 2521 6799 *1074 5344 9610 3872 5793 *0088 4379 8666 2949 7227 *1501 5771 *0037 4298 6223 *0517 4808 9094 3377 7655 *1928 6198 *0463 4724 6652 *0947 5237 9523 3805 8082 *2355 6624 *0889 5150 7082 *1376 5666 9951 4233 8510 *2782 7051 *1316 5576 8130 2384 6633 *0878 5120 9357 3590 7818 *2043 6264 8556 2809 7058 *1303 5544 9780 4013 8241 *2465 6685 8981 3234 7483 *1727 5967 *0204 4436 8664 *2887 7107 9407 3659 7907 *2151 6391 *0627 4859 9086 *3310 7529 9832 4084 8332 *2575 6815 *1050 5282 9509 *3732 7951 *0480 4692 8901 3105 7305 *1501 5693 9881 4065 8245 *0901 5113 9321 3525 7725 *1920 6112 *0300 4483 8663 *1323 5534 9742 3945 8144 *2340 6531 *0718 4901 9080 *1744 5955 *0162 4365 8564 *2759 6950 *1137 5319 9498 *2165 6376 *0583 4785 8984 *3178 7369 *1555 5737 9916 2421 6593 *0761 4925 9084 3240 7392 *1540 5684 9824 2838 7010 *1177 5341 9500 3656 7807 *1955 6099 *0238 3256 7427 *1594 5757 9916 4071 8222 *2369 6513 *0652 3673 7844 *2010 6173 *0332 4486 8637 *2784 6927 *1066 4090 8260 *2427 6589 *0747 4902 9052 *3198 7341 *1479 3961 4374 4787 5201 5614 d. 434 434 433 433 432 432 431 431 431 430 430 429 429 429 428 428 427 427 426 426 426 425 425 424 424 424 423 423 422 422 422 . 421 421 420 420 420 419 419 418 418 417 417 417 416 416 415 415 415 414 414 413 01 234 5 6789 d. N. 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 1096 1097 1098 1099 1100 N. LOGARITHMS (continued) 0 1234 021 1893 2307 2720 3134 3547 6027 6440 6854 7267 7680 022 0157 0570 0983 1396 1808 4284 4696 5109 5521 5933 8406 8818 9230 9642 *0054 023 2525 2936 3348 3759 4171 6639 7050 7462 7873 8284 024 0750 1161 1572 1982 2393 4857 5267 5678 6088 6498 8960 9370 9780 *0190 *0600 025 3059 3468 3878 4288 4697 7154 7563 7972 8382 8791 026 1245 1654 2063 2472 2881 5333 5741 6150 6558 6967 9416 9824 *0233 *0641 *1049 027 3496 3904 4312 4719 5127 7572 7979 8387 8794 9201 028 1644 2051 2458 2865 3272 5713 6119 6526 6932 7339 9777 *0183 *0590 *0996 *1402 029 3838 4244 4649 5055 5461 7895 8300 8706 9111 9516 030 1948 2353 2758 3163 3568 5997 6402 6807 7211 7616 031 0043 0447 0851 1256 1660 4085 4489 4893 5296 5700 8123 8526 8930 9333 9737 032 2157 2560 2963 3367 3770 6188 6590 6993 7396 7799 033 0214 0617 1019 1422 1824 4238 4640 5042 5444 5846 8257 8659 9060 9462 9864 034 2273 2674 3075 3477 3878 6285 6686 7087 7487 7888 035 0293 0693 1094 1495 1895 4297 4698 5098 5498 5898 8298 8698 9098 9498 9898 036 2295 2695 3094 3494 3893 6289 6688 7087 7486 7885 037 0279 0678 1076 1475 1874 4265 4663 5062 5460 5858 8248 8646 9044 9442 9839 038 2226 2624 3022 3419 3817 6202 6599 6996 7393 7791 039 0173 0570 0967 1364 1761 4141 4538 4934 5331 5727 8106 8502 8898 9294 9690 040 2066 2462 2858 3254 3650 6023 6419 6814 7210 7605 9977 *0372 *0767 *1162 *1557 041 3927 4322 4716 5111 5506 5 67 89 3961 8093 2221 6345 *0466 4582 8695 2804 6909 *1010 4374 8506 2634 6758 *0878 4994 9106 3214 7319 *1419 4787 8919 3046 7170 *1289 5405 9517 3625 7729 *1829 5201 9332 3459 7582 *1701 5817 9928 4036 8139 *2239 5614 9745 3871 7994 *2113 6228 *0339 4446 8549 *2649 5107 9200 3289 7375 *1457 5535 9609 3679 7745 *1808 5516 9609 3698 7783 *1865 5942 *0016 4086 8152 *2214 5926 *0018 4107 8192 *2273 6350 *0423 4492 8558 *2620 6335 *0427 4515 8600 *2680 6757 *0830 4899 8964 *3026 6744 *0836 4924 9008 *3088 7165 *1237 5306 9371 *3432 5867 9922 3973 8020 2064 6104 *0140 4173 8201 2226 6272 *0327 4378 8425 2468 6508 *0544 4576 8604 2629 6678 *0732 4783 8830 2872 6912 *0947 4979 9007 3031 7084 *1138 5188 9234 3277 7315 *1350 5382 9409 3433 7489 *1543 5592 9638 3681 7719 *1754 5785 9812 3835 ' 6248 *0265 4279 8289 2296 6298 *0297 4293 8284 2272 6650 *0667 4680 8690 2696 6698 *0697 4692 8683 2671 7052 *1068 5081 9091 3096 7098 *1097 5091 9082 3070 7453 *1470 5482 9491 3497 7498 *1496 5491 9481 3468 7855 *1871 5884 9892 3897 7898 *1896 5890 9880 3867 6257 *0237 4214 8188 2158 6124 *0086 4045 8001 *1952 6655 *0635 4612 8585 2554 6520 *0482 4441 8396 *2347 7053 *1033 5009 8982 2951 6917 *0878 4837 8791 *2742 7451 *1431 5407 9379 3348 7313 *1274 5232 9187 *3137 7849 *1829 5804 9776 3745 7709 *1670 5628 9582 *3532 5900 6295 6690 7084 7479 0 1 2 34 5 6789 d. 413 413 413 412 412 411 411 411 410 410 410 409 409 408 408 408 407 407 406 406 406 405 405 405 404 404 403 403 403 402 402 402 401 401 400 400 400 399 399 399 398 398 398 397 397 397 396 396 395 395 395 d. BIBLIOGRAPHY 1. "Water Hammer in Conduits; Study of the Means Used for Diminishing the Effects," by J. Michaud. Bulletin de la Societe Vaudoise des Ingenieurs et Architects; Lausanne 1878. ' 2. "Water Hammer," by Joukowsky, translated by Miss O. Simin. Proc. Am. Water Works Assoc., 341, 1904. 3. Theory of Water Hammer, by Lorenzo Allievi, translated by Eugene Halmos. Riccardo Garroni, Rome, Italy, 1925. 4. Symposium on Water Hammer, American Society of Me chanical Engineers, New York, June, 1933. 5. "Pressures in Penstocks Caused by the Gradual Closing of Turbine Gates," by N. R. Gibson. Trans. A.S.C.E., Vol. 83, 1920, p. 707. 6. "Variations of Flow in Water Conduits," by M. L. Bergeron. Comptes Rendus des Traoaux de la Societe Hydro technique de France, 1932. 7. "Methods of Calculating Water Hammer Pressures," by F. M. Dawson and A. A. Kalinske. }. Am. Water Works Assoc., Vol. 31, No. 11, Nov., 1939, p. 1835. 8. "Simple Graphical Solution for Pressure Rise in Pipes and Pump Discharge Lines," by R. W. Angus. Engineering Journal, v. 18, n. 2, February, 1935. 9. "The Differential Surge Tank," by R. D. Johnson. Trans. A.S.C.E., Vol. 78, 1915. 10. Hydraulic Transients, by G. R. Rich, McGraw-Hill, New York, 1951. 11. Fluid-Meters, American Society of Mechanical Engi neers, New York, 1937. 12 "Typical Analysis of Water Hammer in a Pumping Plant of the Colorado River Aqueduct," by R. M. Peabody. Trans. A.S.M.E., Vol. 61, 1939, p. 117. 13 "A Survey of Flow Calculation Methods," by S. P. Johnson. Preprinted Papers and Program-A.S.M.E. Summer Meeting, June, 1934, p. 98. 14. "The Occurrence and Elimination of Surge or Oscillat ing Pressures in Discharge Lines From Reciprocating Pumps, by H. Diederichs and W. D. Pomeroy. Trans. A.S.M.E., Vol. 51, Pet. 51-2-9, 1929. 15. "Transmission of Pressure Waves in Liquid Filled Tubes," by W. T. Thomson. Proc. of the First U.S. Natl Congress of Applied Mechanics, 1951, p. 927. 16. "Pressure Surges and Vibration in Reciprocating Pump Piping," by J. W. Squire. Trans. A.S.M.E., Vol. 71, May, 1949, p. 317. 17. Pressure Surge Research Project No. 1, Final Report, by R. L. Flanders, E. J. Waller, et al. Oklahoma A & M Col lege, Stillwater, Oklahoma, Feb., 1953. 18. Advanced Fluid Dynamics and Fluid Machinery, by R. C. Binder. Prentice-Hall, New York, 1951. 19. ASME-API Code for Installation, Proving and Opera tion of Positive Displacement Meters in Liquid Hydrocarbon Service, No. 1101, American Petroleum Institute, New York, 1952. 20. Handbook of Chemistry and Physics, Chemical Rubber Publishing Co., Cleveland. ' 21. Engineering Hydraulics, edited by Hunter Rouse. Wiley. New York, 1950. . [54] The Author Howard Moore received a degree o B.A. in Math ematics and Physics at the University of Colorado. He taught mathematics and physics in the Colorado public schools for a time. In the field of mechanical and hydraulic engineering he had experience as a research laboratory analyst, draftsman and designer for Douglas Aircraft Company at Long Beach, Cali fornia where he conducted tests on mechanical, pneumatic, and hydraulic aircraft components and systems; designed flight control and cargo loading mechanisms. He supervised mechanical design and design of fluid handling systems for Aerojet Engi neering Corporation, Azusa, California, for the F-84 and B-47 rocket test cell installations, the RocketEngine Test Stands at Edwards Air Force Base, Cali fornia, and the Turbopump Testing Facility', also at Edwards Air Force Base. He directed the design of the Air Transportable Hydrant Refueling System for Aircraft and conducted surge investigations for the American Pipe and Steel Corporation of Alhambra, California. Currently, as a project engineer in the MagniLastic Division of Cook Electric Company he is responsible for the analysis and control of surge in fluid handling systems and the application of surge and pulsation suppressing devices. He is a member of the Society of American Military Engineers.