Document 7OojB4YkLYNryKVzqo7vw6eR8
460.0902 -Asbestos
January 24, 1990 AREA MANAGER-ENVIRONMENTAL REGULATIONS: Attached are the results of the asbestos bulk'samples you requested from the 1010 Pine Frame room. The samples were taken from the scrap wire bag and the soldering iron holder pad. If you have any questions, please call me on 235-5592. Area Manager-Safety Human Resources Benefits & Mgmt. Admin Attachments
004816
INDUSTRIAL TESTING
Chemists Engineers
2350 Seventh Blvti. St. Louis, Missouri 63104 314/771*7111
Report No.. : 90-01-00460
Contract No. i C1401HD
Southwestern Bell Telephone Co 1010 Pine Street, Room 802 St. Louis, MO 63101
January 22, 1990 Attn: Mr. Charles Hill
Included in this report are test results obtained on two (2) bulk samples submitted on January 19, 1990.
The following information was provided by the client:
Project: S.W.B.T. Location: 1010 Pine Street, 2nd Floor, St. Louis, MO
The United States Environmental Protection Agency defines any sample containing greater than one (1) percent asbestos as an asbestos-containing material (ACM) (40 CFR Part 763). Samples determined to have asbestos concentrations greater than one (1) percent are identified in the test results as asbestos-containing materials.
Material content is determined using polarized light microscopy with dispersion staining in accordance with EPA-600/M4-82-Q20, "Interim Method for the Determination of Asbestos in Bulk Insulation Samples," and all current revisions.
All layers of heterogeneous samples are analyzed separately. Material concentrations are reported as a percentage of the entire sample: submitted.
004817
INDUSTRIAL TESTING
Chemists Engineers
2350 Smanih Biva. St. Louis, Missouri 63104 314/771-7111
Report No.: 90-01-00460
Industrial Testing Laboratories, Inc. is accredited by the United States Environmental Protection Agency for the analysis of asbestos in bulk samples (Laboratory ID Number 7355).
Analysis By: Sue Ferrario
: S(AJ. l3iAAAAsu&__________
Microanalyst
Analysis Completed: January 19, 1990
Respectfully submitted,
William J. Lowry, Manager Environmental Lab
Lab No.: 184777 - 184778 SF/nm
Invoice No.: 35814
004818
K INDUSTRIAL TESTING LABORATORIES inc.
Client: Southwestern Bell Telephone Co.
Report Number: 90-01-00460
ITL Number:
184777 :
TEST REPORT
ITL Number:
184777
Identification:
11790-1, Solder Iron Holder Pad
Dominant Color: Gross Sample Appearance:
White Heterogeneous, Fibrous
SECTION I_L INDIVIDUAL LAYER ANALYSIS _
=> Layer Number: 1
Percent of Total Sample: 100%
Material Content
> ASBESTOS CONTAINING MATERIAL <--
* Asbestos,Chrysotile
50-60%
Synthetic Fiber
30-40%
Binder
3-5%
Unspecified Non-Fibrous Material Trace (less than 1% present)
SECTION II: SUMMARY (100 % of Sample)
========>
ASBESTOS CONTAINING MATERIAL
<========
Material Content: Asbestos,Chrysotile Synthetic Fiber Binder Unspecified Non-Fibrous Material
50-60% 30-40% 3-5% Trace (less than 1% present)
00,4819
fc
INDUSTRIAL TESTING
LABORATORIES ino.
Client: Southwestern Bell Telephone Co.
Report Number: 90-01-00460
ITL Number:
184778
TEST REPORT
ITL Number:
184778
Identification:
11790-2, Scrap Wire Bag Material
Dominant Color: Gross Sample Appearance:
Grey Homogeneous, Fibrous
SECTION li INDIVIDUAL LAYER ANALYSIS _
==> Layer Number: 1
Percent of Total Sample: 100%
Material Content. No asbestos detected Cotton Binder
(less than 1% if present) 90-95% 5-10%
SECTION II: SUMMARY (100 % of Sample)
Material Content: No asbestos detected Cotton Binder
(less than 1% if present) 90-95% 5-10%
004820