Document 7OmpeGzOYpKmbDRE2BqGM3wGj

Air Conditioning andc^f HERmSR RELiOR Division of the American Air Filter Company, Inc. Louisville, Kentucky Moline, Illinois Branch Offices and Product-Application Engineers in the Following Cities: Atlanta, Ga. Baltimore, Md. Boston, Mass. Buffalo, N. Y. Cape Elizabeth.Me. Chicago, III. Cincinnati, O. Cleveland, O. Columbus, O. Dallas, Tex. Denver, Colo. Des Moines. Iowa Detroit, Mich. Duluth, Minn. Grand Raptor Mich. Greensboro, N. C. Houston, Tex. Indianapolis, Ind. Jackson, Miss. Kansas Citt, Mo. Los Angeles, Calif. Louisville. Ky. Memphis, Tenn. Miami, Fla. Milwaukee, Wis. Minneapolis, Minn. Missoula, Mont. Moline, III. Nashville, Tenn. New Orleans, La. New York, N. Y. Oklahoma City, Okla. Omaha, Neb. Philadelphia, Pa. Phoenix, Ariz. Pittsburgh, Pa. Portland, Ore. Richmond^ Va. Saginaw, Mich. St. Louis, Mo. Salt Lake City, Utah San Antonio, Tex. San Francisco, Calif. Seattle, Wash. Spokane, Wash. Springfield, Mass. Syracuse, N. Y. Washington, D. C. HERMAN NELSON HORIZONTAL SHAFT PROPELLER. FAN TYPE UNIT HEATERS. Designed for ceiling suspension, these unit heaters project warm air downward in an angular direction. Copper heating element for use with steam or .hot water, incorporates patented stay tube which maintains proper relationship between headers without increasing strain on loops thus prolonging life of unit. A wide variety of models, sizes and arrangements. HERMAN NELSON VERTICAL SHAFT PROPELLER-FAN TYPE UNIT HEATERS. For high ceiling installations. Dis charge air vertically downward, or at an angle to vertical in various directions. Long life copper heating element for use with steam or hot water incorporates patented stay tube. Units available with either high or low velocity discharge, each with a wide range of capacities. HERMAN NELSON DE LUXE UNIT HEATERS. Efficient economical, compact, quiet and attractive, these Unit Heaters provide the ideal method for heating offices, showrooms, corridors, markets, stores, etc. Copper heating element in corporates patented stay tube. Units may be placed on floor, wall or suspended from ceiling. Eighteen models, sizes and arrangements. '' HERMAN NELSON CENTRIFUGAL-FAN TYPE UNIT HEATERS. The Herman Nelson Centrifugal-Fan Type Unit Heater can be applied to solve a multitude of heating and ventilating problems. With 1,890 combinations of models, sizes and speeds available, there is a unit to fit the average requirements of commercial and industrial buildings of all types. HERMAN NELSON DRAFT/STOP UNIT VENTILATORS . . .The DRAFT/STOP Unit Ventilation System developed by Herman Nelson employs a new design principle. Drafts are trapped before they can reach classroom occupants. Cold drafts are prevented from circulating throughout the room to create constantly changing temperature levels.DRAFT/STOP produces abundant fresh air of even temperature ... a truly healthful atmosphere that minimizes the possibility of health hazards. The system is quiet, has a smart modem appearance and is economical, being almost en tirely free of maintenance problems. Herman Nelson Unit Heaters and Unit Ventilators are tested and rated in accord ance with the Standard Test Code adopted jointly by the Industrial Unit Heater Association and The American Society of Heating and Ventilating En gineers. 1200 Air Conditioning HERRHH1 REISQn Division of the American Air Filter Company, Inc. Louisville, Ky. Moline, 111. bSw Model BN HERMAN NELSON DIRECT DRIVE PROPELLER FANS. Provide economical and high quality ventilation for. indus trial buildings of all types. 11 standard sizes available with wheel diameters from 10 to 36 in. and capacities from 655 to 12,400 cfm. There are 7 high powered models to operate against static resistance of % in., with wheel diameters from 14 to 36 in., and capacities from 1,800 to 14,600 cfm. Also three models especially adapted to small store and office applica tions. Standard Models available with two speed motors. HERMAN NELSON BELT DRIVE PROPELLER FANS. For public and commercial building installations where slow speed, quiet operation are required. Twelve sizes of the stand ard model with wheel diameters from 24 in. to 54 in. Also six sizes of the High Powered model with the same wheel diam eters. Capacities: 5,650 to 36,150 cfm. Due to quiet operation of Herman Nelson Belt Drive Propeller Fans, use of two speed motor is unnecessary. HERMAN NELSON DIRECT DRIVE UNIT BLOWERS. De signed for many applications, such as fume hoods, toilet ventilation, chemical laboratories, industrial processing and drying problems. Compact, direct connected, motor driven units have universal discharge and mount on floor, wall or ceiling. Available in five sizes with 12 speed combinations. Wheel diameters from \Y> in. to 11 in. and capacities from 160 to 2,265 cfm. HERMAN NELSON BELT DRIVE UNIT BLOWERS. Fully self-contained unit including motor, drives and housing; slow speed or non-overloading type wheels available ; adjustable motor pedestal with vibration dampers; universal discharge; ten sizes with 92 drive combinations. Available with any rotation and discharge. Wheel diameters from 9J4 in. to 30 in. and capacities from 700 to 18,303 cfm. HERMAN NELSON CENTRIFUGAL FANS. Herman Nelson Centrifugal Fans are designed and constructed for smooth, efficient, long-life operation on any system requiring the use of a Class I or II centrifugal fan. These fans are available in either slow speed or non-over-loading type; 17 wheel diameters from 12% to 73 in.; single or double width; 8 arrangements for direct or belt drive; and any rotation or discharge. Herman Nelson Propeller and Centrifugal Fans are tested and rated in accordance with the Standard Test Code adopted jointly by the National Association of Fan Manufacturers and The American Society of Heating and Ventilating En gineers. 1201