Document 7OkM8py8oGqoXER475Nrx9JaV

Monsanto MONSANTO INDUSTRIAL CHEMICALS CO. 800 N. Lindbergh Boulevard St. Louis, Missouri 6318B Phone: (314) 694-1000 ' October 12, 1972 Mr. Robert C. Brandenburg Acting Deputy Associate Commissioner for Compliance (CC-2) Food and Drug Administration Room 9-57 5600 Fishers Lane Rockville, Maryland 20852 Re: Department of Health, Education and Welfare Food and Drug Administration 21 CFR Parts, 35 121; 122; 128 Polychlorinated Biphenyls, Notice of Proposed Rule Making Federal Register, Vol. 37, No. 54, pp. 5705-5707 Saturday, March 18, 1972 Dear Mr. Brandenburg: In our comments submitted on July 14, 1972 and relating to the proposed regulations pertaining to PCBs in food, animal feed, food and feed processing plants and packaging materials we referred to our experience with Monsanto Company heat transfer systems which had been converted to non-PCB fluids. Additionally we had offered to share with appropriate representatives in the Food and Drug Adminis tration the available information pertaining to these con versions. Attached is a summary of Monsanto's experience describing the system size, operating temperature, conversion pro cedure and the residual PCB in the system of typical units. All of these units are in chemical processing service and include heating coils, shell and tube heat exchangers. Jacketed tanks and Jacketed pipelines -- all of which are very common in the chemical industry. a unit of Monsanto Company <?39?5? ' ' ' T* PCB-ARCH0743997 ij Mr. Robert C. Brandenburg October 12, 1972 Page 2 In all cases the replacement fluid Is Monsanto's Therminol 66, a modified terphenyl containing no halogens. A copy of bulletin IC/FF-66 which describes this fluid is enclosed. We hope this information will be useful to the Administration In determining the acceptable residual level of PCBs which can be realistically achieved in well run, properly managed systems. Respectfully submitted. W. B. Papageorge Manager Environmental Protection WBP/bt _ Enclosure ccs Hearing Clerk Department of Health, Education and Welfare Room 6-88 5600 Fishers Lane Rockville, Maryland 28052 Mr. John R. Wessel Office of Associate Commissioner for Compliance Food and Drug -Administration Room 9-57 56OO Fishers Lane Rockville, Maryland 28052 bee 1 W. R, Corey K. V. Easley - 1920 JK F, 8tapleton 0239758 . . r_. PCB-ARCH0743998 System 1 2 3 4 5 6 7 8 9 Volume (Gallons) 880 400 2300 990 1300 250 1000 700 1200 Normal Operating Temperature (P) 360 440 480 580 500 520 500 650 650 Conversion Method Drained. Flushed with replacement fluid circulating for 20 hours at 300F. Filled. Drained. Flushed with replacement fluid circulating for 20 hours at 300F. Filled. Drained. Flushed with replacement fluid circulating for 10 hours at 400F. Repeated flushing. Filled. Drained. Flushed with replacement fluid circulating for 20 hours at 480P. Blown with nitrogen. Filled. Drained. Flushed with replacement fluid circulating for three hours at 80F. Flush repeated with replacement fluid circulating for 14 months at 500F. Filled. Drained. Flushed with acetone circulating for three hours .at 80F. Blown with nitrogen. Flushed with Okite solution for three hours at 80F. Filled. Drained. Replaced piping. Filled. Drained. Flushed with replacement fluid briefly. Flushed again with replacement fluid circulating for two days at 400F. Flushed with Dowell inhibited acid circulating for three hours. Filled. Drained. Flushed twice with Dowell inhibited acids circulating for three hours per flush followed by high pressure water flush. Filled. PCB Residual Wt # 1.0 1.5 1.5 1.7 0.7 0.1 0.5 2.7 0.7 0239759 PCB-ARCH0743999 System 10 11 12 13 14 15 16 17 18 Volume (Gallons) 300 300 4000 1650 250 3000 250 300 340 Normal Operating TemjDgrature 400 400 550 500 430 580 520 400 400 Conversion Method PCB Residual .. wt 4 Drained. Flushed with replacement fluid circulating for four hours at 80F. Filled. "?7&- lo-*f Drained. Flushed with replacement fluid circulating for four hours at 80F. Filled. ' Drained. Flushed with replacement fluid 3>.Kt**s 9.3 f ` circulating for 30 days at 550F. Filled. ardxs. Drained. Blown with nitrogen. Filled. 5.7 Drained. Flushed with replacement fluid 3.2 circulating for four hours at 80F. Filled. Drained. Flushed with chemical cleaning solu- 4.8 tlon consisting of 556 detergent, 20^6 phosphates and 6056 Cellosolve. Flushed with neutralizing solution of sodium tripolyphosphate. Filled. Drained, Flushed with replacement fluid circulating for four hours at 80F. Filled. 0.2 . Drained. Flushed with xylene circulating for four hours at 80F. Filled. 0.8 _ Drained. Flushed with xylene circulating for 5.3 four hours at 80F. Filled. ..... 0239760 Page 2 PCB-ARCH0744000