Document 7OdD739yBgNy7Vv3rEM4BnK96

OBJECTIVES 1. Progress report on laboratory biodegradation of PCBs. 2. Residue accumulation studies In fish, birds and mammals. 3. To show reduction in less biodegradable PCBs as a result of Monsanto actions on sales and products. MGNS 059751 MONSANTO PCB ACTIONS 1. Phase-out of PCB sales worldwide In all applications except Dielectrics. 2. Conversion of Dielectric Fluids to more bio degradable PCBs. MQNS 059752 DEGREE OP BIODEGRADATION OF PCBs Based on data presented: - Transition In biodegradation occurs around penta-/hexa-chloroblphenyl. - Disappearance of all homologs below hexachloroblphenyl observed. - Per.ta- and higher TCB determined by specific GLC/MS Test Method. HONS 059753 MONSANTO PCB SALES IN U.S.A (Million Pounds) 1969 1970 1972 (Eat.) Dielectrics 37-0 40.5 32.0 All Others 30.0 33-5 - Total 67.O 74.0 32.0 MONS 059254 EFFECT OF PHASE-OUT POLICY FCB sales reduced In U. S. A, by 30 to 33 million pounds, or ^5/i* HONS 059755 PCB PRODUCT CHANGES IN DIELECTRICS CAPACITORS 97; conversion to Aroclor 1016 TRANSFORMERS Elimination of Aroclor 1260 HONS 059756 PCBs USED IN CAPACITORS PCB Aroclor 1254 Aroclor 1242 Aroclor 1016 Major Use Period a PCB (Penta- % PCB (Hexa- chloro- and chloro- and Higher Higher 1930-1952 77.0 23.0 1952-Sept. 1971 9.0 1.0 Oct. 1971- 1.0 0.01 HONS 059757 Capacitor Fluids Why Convert to Aroclor 1016? 1. 9-fold reduction in PCBs of pentachloro- and higher. 2. 100-fold reduction In PCBs of hexachloro- and higher. 3. Minimum Industry testing required. MONS 059758 Capacitor Fluids What Is The Effect of Aroclor 1016? u.s. Capacitor Fluid Sales (1972):<v 20 R lbs. If Aroclor Was 125^ 12*12 1015 % Pentachloroand higher PCBs Would Be* 15,400,000 pounds 1,800,000 200,000* % Hexa chloroand Higher PCBs Would Be* 4,600,000 pounds 200,000 2,000 *Thls does not mean amounts of PCB entering the environment. MCNS 059759 WHAT IS CAPACITOR FAILURE RATE? Industry Sources Cite : 0.02-0.2# Fer Year MOMS 059760 IP CAPACITOR FAILURE RATE IS 0.2% PER YEAR ----------------------------------------------- TrorarnffSET PCB ESCAPE TO ENVIRONMENT* IS -- All PCB Homologs Penta Chloro- and higher Hexa Chloro- and higher Aroclor 1242 40,000 pounds 3,600 400 Aroclor 10l6 40,000 pounds 400 4 Assumes U.S. Fluid Sales of 20 M Lb./Year HONS 059761 PCBs PRESENT IN ASKARBL TRANSFORMER FLUIDS <f, PCBs Pentachloroand Higher % PCBs Hexachloroand Higher Major Use Period Aroclor 1260 100 70 1930-1972 Aroclor 1254 Aroclor 1242 77 9 23 19591 1968- HONS 059762 PCB CHANGES IN TRANSFORMER FLUID APPLICATIONS 1. Aroclor 1260 being phased out now. 2. Aroclor 1016 cannot be used. 3. Incineration of scrap PCBs - 1971Note^ Askarel (PCB) transformers are tightly sealed units. MCNS 059763 WHAT IS FAILURE RATE IN LIQUID TRANSFORMERS? Industry sources cite: Under 0.2# per year* * All liquid types - mineral oil and PCB. PCB failure could be less since they are Inherently safer. MOMS 059764 IP ASKAREL (PCB) TRANSFORMERS FAIL AT 0.2#/YEAR HOW MUCH PCB IS AFFECTED*? All PCB Homologs Penta Chloro-and Higher Hexa Chloro-and Higher Aroclor 1254 24,000 lbs. 18,480 5,520 Aroclor 1242 24,000 lbs. 2,160 240 (Estimated PCB transformer fluid sales In U.S. 12 M lb./year) * With Incineration facilities available, not all these amounts will enter environment. MCNS 059765 Monsanto's Present Program To Prevent Environmental Pollution By PCB3 1. No more sales world-wide except approved dielectric users. 2. Restrict over 9756 capacitor fluid sales to Aroclor 1016 only. 3. Restrict PCBs In transformer fluids to Aroclor 1254 and 1242. 4. Continue Incineration facilities for scrap PCBs. 5. Encourage dielectric Industry through ANSI C-107 to enforce strict environmental control over PCBs. MQNS 059766