OBJECTIVES 1. Progress report on laboratory biodegradation
of PCBs. 2. Residue accumulation studies In fish, birds
and mammals. 3. To show reduction in less biodegradable PCBs
as a result of Monsanto actions on sales and products.
MGNS 059751
MONSANTO PCB ACTIONS 1. Phase-out of PCB sales worldwide In all
applications except Dielectrics. 2. Conversion of Dielectric Fluids to more bio
degradable PCBs.
MQNS 059752
DEGREE OP BIODEGRADATION OF PCBs Based on data presented:
- Transition In biodegradation occurs around penta-/hexa-chloroblphenyl.
- Disappearance of all homologs below hexachloroblphenyl observed.
- Per.ta- and higher TCB determined by specific GLC/MS Test Method.
HONS 059753
MONSANTO PCB SALES IN U.S.A (Million Pounds)
1969 1970 1972 (Eat.)
Dielectrics 37-0 40.5 32.0
All Others 30.0 33-5 -
Total 67.O 74.0 32.0
MONS 059254
EFFECT OF PHASE-OUT POLICY FCB sales reduced In U. S. A, by
30 to 33 million pounds, or ^5/i*
HONS 059755
PCB PRODUCT CHANGES IN DIELECTRICS CAPACITORS
97; conversion to Aroclor 1016 TRANSFORMERS
Elimination of Aroclor 1260
HONS 059756
PCBs USED IN CAPACITORS
PCB Aroclor 1254 Aroclor 1242 Aroclor 1016
Major Use Period
a PCB (Penta- % PCB (Hexa-
chloro- and
chloro- and
Higher
Higher
1930-1952
77.0
23.0
1952-Sept. 1971
9.0
1.0
Oct. 1971-
1.0
0.01
HONS 059757
Capacitor Fluids Why Convert to Aroclor 1016? 1. 9-fold reduction in PCBs of pentachloro- and higher. 2. 100-fold reduction In PCBs of hexachloro- and higher. 3. Minimum Industry testing required.
MONS 059758
Capacitor Fluids What Is The Effect of Aroclor 1016?
u.s. Capacitor Fluid Sales (1972):<v 20 R lbs.
If Aroclor Was
125^
12*12
1015
% Pentachloroand higher PCBs
Would Be*
15,400,000 pounds
1,800,000
200,000*
% Hexa chloroand Higher PCBs
Would Be*
4,600,000 pounds
200,000
2,000
*Thls does not mean amounts of PCB entering the environment.
MCNS 059759
WHAT IS CAPACITOR FAILURE RATE? Industry Sources Cite : 0.02-0.2# Fer Year
MOMS 059760
IP CAPACITOR FAILURE RATE IS 0.2% PER YEAR
----------------------------------------------- TrorarnffSET
PCB ESCAPE TO ENVIRONMENT* IS --
All PCB Homologs Penta Chloro- and higher Hexa Chloro- and higher
Aroclor 1242
40,000 pounds
3,600
400
Aroclor 10l6
40,000 pounds 400 4
Assumes U.S. Fluid Sales of 20 M Lb./Year
HONS 059761
PCBs PRESENT IN ASKARBL TRANSFORMER FLUIDS
<f, PCBs Pentachloroand Higher
% PCBs Hexachloroand Higher
Major Use Period
Aroclor 1260
100
70 1930-1972
Aroclor 1254 Aroclor 1242
77 9
23 19591 1968-
HONS 059762
PCB CHANGES IN TRANSFORMER FLUID APPLICATIONS 1. Aroclor 1260 being phased out now. 2. Aroclor 1016 cannot be used. 3. Incineration of scrap PCBs - 1971Note^ Askarel (PCB) transformers are
tightly sealed units.
MCNS 059763
WHAT IS FAILURE RATE IN LIQUID TRANSFORMERS? Industry sources cite: Under 0.2# per year* * All liquid types - mineral oil and PCB.
PCB failure could be less since they are Inherently safer.
MOMS 059764
IP ASKAREL (PCB) TRANSFORMERS FAIL AT 0.2#/YEAR HOW MUCH PCB IS AFFECTED*?
All PCB Homologs Penta Chloro-and Higher Hexa Chloro-and Higher
Aroclor 1254 24,000 lbs. 18,480
5,520
Aroclor 1242 24,000 lbs.
2,160 240
(Estimated PCB transformer fluid sales In U.S. 12 M lb./year)
* With Incineration facilities available, not all these amounts will enter environment.
MCNS 059765
Monsanto's Present Program To Prevent Environmental Pollution By PCB3
1. No more sales world-wide except approved dielectric users.
2. Restrict over 9756 capacitor fluid sales to Aroclor 1016 only.
3. Restrict PCBs In transformer fluids to Aroclor 1254 and 1242.
4. Continue Incineration facilities for scrap PCBs. 5. Encourage dielectric Industry through ANSI
C-107 to enforce strict environmental control over PCBs.
MQNS 059766