Document 7OZq3XvzYNGX95DMXEJ2xBMej
AIRBORNE FIBER COUNTS for
Paco Textures Company Los Gatos, California
Date Sampled: June 12, 1975 Date Reported: June 30, 1975
Samples Collected By: H. B. Rhodes Union Carbide Corporation
Samples Analyzed By: B. L. Ingalls Union Carbide Corporation
Reported By:.
H. B. Rhodes Union Carbide Corporation
KM 01235
Union Carbide Corporation
Metals Division Niagara Falls, New York
KMX 00163
OBJECTIVES
3. To measure the airborne asbestos fiber counts during the mixing and spraying of ceiling texture spray.
' 2. To compare the asbestos fiber counts for products containing Canadian grade 7M05 asbestos and Canadian HPO.
DESCRIPTION OF OPERATION
'
The tests- were carried out at two locations in Los Gatos, CA. In
each case, ceiling texture formulations differing in the type of asbestos
used were sprayed by the same operator under very similar conditions. The
first series of tests was typical of the small, custom operation while the
second was more representative of large "mass-production" type procedures
and equipment.
'
In the first sequence.(Pyramid Painting and Drywall), the operator added four 3-pound bags of Decotex containing 5.2% of J/M 7MQ5 Canadian -asbestos-into the top of a small "Spray Force" mixer-sprayer with a capacity of^90 gallons. Approximately half of the ceilings in a large sTngle-story house were sprayed with this mixture. The tank was then washed out and 4 bags of Decotex containing 4.1% of "Calidria" HPO Were mixed and sprayed. The mixture ran out before the spraying was completed and two more bags were mixed.
Personal samples were taken on the operator during each main mixing and during each spraying sequence. The two bag supplementary mixing was not sampled. The wiper was sampled during each spraying. One area sample was taken in the opposite end of the house during the spraying of the Canadian .containing material.and the initial part of the Calidria containing operation.
The second sequence was run at another location in Los Gatos with
a large truck-mounted spray unit. Four bags of Decotex containing ^2% HPO
were added to the mixer which was already partially filled. The ceilings
in a complete house were sprayed. A 12-bag blend, of the same-Decotex blend
containing^2.5% Canadian 7M05 was then mixed and sprayed on the ceilings of
a second house. These blends contained an additional pound of styrofoam and
were thicker than that used in the first location. There was some problem
with the spraying of the Canadian containing material'and working pressure
was reduced from 120 to ^70 psjg. There was still more fine overspray than
with the Calidria based product.
-
Personal samples were collected on the spray operator during each
mix -and during each spraying sequence. Personal samples were collected on the "wiper during each spraying.
KMX 00164
SAMPLE EQUIPMENT AND TEST PROCEDURES
Sampling and dust counting were carried out in accordance with OSHA
Regulation 1910.1001, using the Bayer., Zummalde and Brown method for
counting asbestos fibers by phase contrast microscopy (Bureau of Occupational
Safety and Health, Feb. 1969).
'
Battery-powered air pumps (M.S.A. type), calibrated to 2 liters per
minute, were used to collect personal breathing zone and environmental samples on Miliipore membrane filters of 0.8 micron porosity.
t . Fiber counting was performed on a Nikon phase contrast microscope at 400X utilizing a Porton reticle for sizing and field definition.
Two results have been reported for each sample - they are:
1. Total Fiber - Any material longer than 5 microns, having an aspect ratio greater than 3:1. This number will include the asbestos fibers as well as other particles which meet the fore going criteria. If tremolitic talc is present in the sample, the tremolite "chips" and anthophyllite impurities (if present) would also be in this category.
2. Chrysotile. Asbestos Fiber - Any fiber longer than'5 microns, having an aspect ratio greater than 3:1 which, in the judgement of an experienced operator could be chrysotile asbestos.
COMMENTS
.. ` ^e OSHA regulations permit a maximum limit of 5 fibers greater than 5 microns in length per cubic centimeter of air.sampled on an 8-hour, timeweighted average -(TWA)v This .allowable*level-will be reduced to 2~fibers/cc on July 1, 1976. The formula C^-j + C2T2 + CnTn describes the'TWA where
C = fiber count in fibers/cc and T = time.
'
- The regulations also stipulate a ceiling concentration of 10 fibers/cc greater than 5 microns which is not to be exceeded at any time..
TEST RESULTS
. The details of sample collection and resultant fiber counts are listed
in the attached table. '
OO'i5
SUMMARY OF FIBER COUNTS
Sample No.
.'
Air Sample
.
Time
Minutes _______ Operation Description_________
Airborne Fiber Count
(fibers/cc >5u)
Chrysotile
Total
Asbestos
First Tests - Pyramid Paint
B-08
8:26-8:36am
10 Personal sample. Operator (Ray
3;7
Struve) mixing 4 bags of Decotex
ceiling spray. Contained^5.2% of
Canadian 7M05, limestone, California
talc, kaolin clay and polystyrene
aggregate. Actual handling of
asbestos took<^2 minutes. Remainder
of time used in wetting and mixing.
.
3.2
B-02
8:40-8:56am
16 Personal sample. Operator (Ray
1.8
Struve) during spraying Canadian
containing blend. Spray on for^12
minutes. (Canadian asbestos)
1.6
B-03
8:56-9:04am
8 Personal sample. Operator (Ray
3.4
Struve) mixing 4 bags of Decotex
ceiling spray. Contained^4.1% of
"Calidria" asbestos HPO. Other
ingredients same as for sample B-08.
2.7
B-05 9:04-9:19am
11 Personal sample. Operator (Ray
Struve) spraying texture containing
HPO.
.
0.9
--
9:15-9:16am
-- Operator mixed two bags of HPO based
material. This operation was not sampled.
No Sampled
B-07
8:4Q-9:00am
20 Personal sample. Helper (Bill Under 1.0 wood) wiping overspray on walls.
(Canadian asbestos containing spray.)
0.8
B-06
9:02-9:26am '
24 Same as B-07. During spray of material containing HPO.
0.7 0.5
B-04
8:50-9:07am
17 Area sample. In opposite end of
0.6
house during spraying of Canadian
containing material, between opera
tions, and the start of the "Calidria"
containing material.
0.4
KMX 00166
Nummary of Ftber Counts - Continued
2- -
Sample No.
Air Sample
Time
1Minutes,
Operation Description
Airborne Fiber Count
(fibers/cc >5u)
Chrysotile
Total
Asbestos
Second Tests
A-67
1:30--1:53pm
23 Personal sample. Spray operator
1.8
(Bill Lowe) mixing 4 bags of Decotex
containing 2.0% HP0. (More styrofoam
than AM samples.). Other ingredients
same as B-08. Actual dumping took
^3 minutes.
' 1.5 `
A-19
1:53-2:30pm
27 Personal sample. Operator spraying 1.2 one house (-*20 minutes spraying).
0.9
A-69
2:21-2:35pm
14 Personal sample. Spray operator
0.9
(Bill Lowe) mixing 12 bags of Decotex
containing <*'2.5% Canadian 7M05
asbestos. More styrofoam than AM
samples. Other ingredients the same.
Actual dumping took ^10 minutes.
0.8
A-89
2:36-3:12pm
36 Personal sample. Spray operator
1.6
(Bill Lowe) adjusting sprayer and
spraying second house with Decotex
containing Canadian asbestos. About
27 minutes actual spraying.
1.0
A-97 - 2:00-2:34pm
34 Personal sample. Wiper (Bill Brede- 1.1
hoft) during spraying of HP0 contain ing texture (1st house).
0.8
A-100 2:25-3:.16pm
51 Personal sample. Wiper (Bill Brede- 0.9 hoft) during spraying t)f-Canadian asbestos containing texture (2nd house).
0.7
KMX 00167