HEATING VENTILATING AIR CONDITIONING GUIDE 1945 flush with the surface of the walls or ceilings, or they may be secured to the face of the wall. They may be covered with wood veneers and decorated to harmonize with other parts of the room, or they may be cast into panels to imitate oak or other wood designs. With flat plate panels it is common practice to use a frame of plaster, wood, metal or composition to allow for expansion. These plates may be heated with either hot water or steam and connected as an ordinary radiator system. See Figs. 5 and 6. 5.- By electric heated metal plates or panels. These plates or panels are either placed in insulated recesses of walls or ceilings or fastened to the construction, as found desirable. -They should not have a surface temperature much above 200 F. Some have a much higher surface temperature but a lower temperature gives a more comfortable condition and is more efficient. 6. By electrically heated tapestry mounted on screens and on the wall. For this purpose Fig. 5. Pillar Type Radiant Heat . Panel 1 Fig. 6. Flat Type Panel Installed^in Wall Recess, the screen is woven with an electric continuous conductor. Such screens are useful to plug in at any position for emergency local heating without taking care of a large room, or office.' Note. If all of a heating panel is installed at one end of a large ropm there may be a marked difference between the BET on the two sides of the body. It is usually desir able, therefore, that the heat be distributed at different parts of the walls and ceilings so that ho uncomfortable effect will be felt from unequal heating. CALCULATION PRINCIPLES The calculations for radiant heating are entirely different from those for convective heating. The purpose of the latter is to determine and compensate for the rate of heat loss from the room,, when the air tempera- 808 CHAPTER 45. RADIANT HEATINC ture is maintained at the desired conditions. Radiant heating, however, involves the regulation of the rate of heat loss from the human body in its several forms. The first step in the calculations for radiant heating of a given room is to determine the desired mean radiant temperature, MRT; the second, to Table 1. Total Radiation to Surroundings at Absolute Zero3 Boot OB Mean Radiant TEMPER ATURE. Deg Fahr- Radiation in Btu per square foot per hour emitted to surroundings with a tempera ture of absolute sero by bodies'at various temperatures and with emiuivity factor e eeee LOO 0.95 0.90 0.80 Boot | OB I Mean. Radiant Temper ature Deg Fahr . Radiation in Bta per square foot per hour Amitixl to surroundings with a temperature-of absolute cero by bodies at 'various temperatures and with emisiyity factor e e0 LOO 0.95 0.90 0.80 30 35 40 45 46 47 . 48 49 50 51 52 53 54 55' 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 99.3 94.3 103.5 98.3 107.6 102.4 112.1 106.5 11219 107.3 113.9 108.2 114.8 109.1 115.6 109.9 116.5 110.6 117.5 111.6 118.4 112.5 119.4 113.4 120.2 114.2 121.1 115.1 122.1 116.0 123.1 117.0 124.0 117.8 124.9 118.6 125.8 119.5 126.6 120.3 127.7 121.4 128.6 122.2 129.6 123.1 130.5 124.0 131.6 125.0 132.5 . 125.9 133,5' 126.8 134.5 127.8 135.5 128.8 89.4 93.2 96.8 100.9 101.6 10215 103.4 104.1 104.9 -105.8 106.5 107.4 108.2 109.0 109.9 110.9 111.6 112.4 113.4 114.0 114.9 115.8 116.7 117.5 118.4 119.3 120.1 121.1 121.9 79.4 71 136.5 . 82.8; 72 137:4-- 86.1 73 138.4 89.7 74- 139.6 90.4 75 141.0 91.1 80 - 146.^6: . 91.9 85 152.3 92:4 90 157.9 93.2 100 "169.6 94.0 110 181.6 94.7 120 194.8 95.5 130 210.1 . 96.2 140 223.2 96.9 150 237.1 97.7 160 251.1 98.5 170 270.5 99.2 180 288.0 99.9 190 306.5 100.7 200 325.2 ' 101.4 210 348.0 102.2 220 : 371.5. 102.9 250 - 437.8 103*7 300 575-. 0 104.4 . -350 740.0 105.4 400 942.1 106.0 450 1176.0 106.8 500 1464.0 107.6 550' 1791.0 108.4 600 2405.0 129.6 130.5 131.5 132.6 133:9 139.4 144.6 149.9 161.1 172.5" 185.0 199.6 212.1 '225.2' 238.8 257.0 273.8 291.0 309.4) 330.6 353.0 415.9 546.1 703.0895.0 1117.0 1390.0 1701.0 2284.0 122.9 123.6 124.5 125.6 126.9 132.0 137.1 142.1 152.6 163.5 175.4 189.1 201.0 213.5 .226.0 243.5 259.1 275.8 292.8 313.1 334.4 394.0 517.5 666.0 847.5 1059.0 1318.0 1613.0 2165.0 109.3 109.9 110.6 111.7 112.8 117.4 121.9 126.4 135.7 145.4 155.9 168.1 178.5 189.7 201.0 216.4 230.4 245.1 260.3 278.4 297.1 350.2 460.0 592.0 753.5 941.0 1171.0 1434.0 1925.0 "These factor* are calculated from the formula where /-0.1723 X r \ 9 " ` V 100.000.000 ) g = total radiation, Btu per square foot per hour. e .= emissivity. T = absolute temperature, degrees Fahrenheit, decide on the location of the heated surfaces; the third, to establish the temperature at which the heating surface shall operate; the fourth, to compute the size of the heating surfaces required to produce this MRT; the fifth, to calculate the actual heat loss from the room and to provide,' if necessary, any additional convected heat beyond that given off by the radiant surfaces for the required number of air changes. If humidification 809