Document 7OE77eXbQnJGz5kN2QLbbdp2a

DownloadRandom document
DEPARTMENT OF THE NAVY NAVAL RESEARCH LABORATORY 4555 OVERLOOK AVE SW W ASHINGTO N DC 20375-5320 N TO: 3900 Ser 6180/0100 From: Commanding Officer, Naval Research Laboratory To: Commander, Naval Sea Systems Command (SEA 05P5 S. Fletcher) Subj: RESULTS OF MIL-F-24385F QUALIFICATION TESTING OF THE NATIONAL FOAM INCORPORATED AER-O-WATER 6EM-C6/TRIDOL-C6 M6 AFFF CONCENTRATE Enel: (1) One copy o f subj ect report 1. Enclosure (1) is forwarded for your information and retention. 2. This report provides results o f the qualification testing for the National Foam Inc. Aer-OWater 6EM-C6/Tridol-C6 M6 AFFF concentrate, which was evaluated against the MIL-F24385F, "Fire Extinguishing Agent, Aqueous Film Forming Foam (AFFF) Liquid Concentrate for Fresh and Seawater" qualification standard. The Aer-O-Water 6EM-C6/Tridol-C6 M6 AFFF product met all o f the fire extinguishment and bum back protection requirements o f the MIL-F-24385F test standard. Based on these test results it is recommended that the Aer-OWater 6EM-C6/Tridol-C6 M6 AFFF product be listed on the AFFF Qualified Products List (QPL). 3. The Naval Research Laboratory's point o f contact is John P. Farley Code 6186, (202) 404 8459, e-mail: iohn.farlev@nrl.navv.mil. By direction Copy to: COMNAVSEASYSCOM (SEA 05P5 Hunstad) US00000937 6180/0100A:JPF 02 May 2016 Results of M11-F-24385F Qualification Testing of the National Foam Inc. Aer-O-W ater 6EMC6/Tridol-C6 M6 AFFF Concentrate John P. Farley Clarence Whitehurst Katherine M. Hinnant Naval Research Laboratory Chemistry Division Washington, DC Ralph Ouellette Stanley KarwosM Jr. Jensen Hughes Baltimore, MD Enel (1) to NRL Ltr 3900 Ser 6180/0100 US00000938 Test results--Paragraphs denoted below refer to the applicable section of MIL-F-24385F P arag rap h 3.3 Chem ical and Physical Requirements for C oncentrates Type 6 Type 6 Pass/ Property: C riteria Value Fail Viscosity @25 C cSt > 2 4.30 Pass Viscosity @5 C cSt <10 8.92 Pass Hydrogen Ion (pH) 7-8.5 8.22 Pass Spreading Coefficient on >3.0 6.27 Pass cyclohexane (dynes/cm) Index of refraction >1.3580 1.3587 Pass Foamability (average of two measurements for eac 1 condition): Fresh Water Expansion Ratio >5.0 8.2 Pass (minutes) Fresh Water Drain Time >2:30 5:46 Pass (minutes) Salt Water Expansion Ratio >5.0 7.6 Pass Salt Water Drain Time >2:30 5:45 Pass (minutes) Film Formation: Full Strength Fresh No No Pass Ignition Ignition Full Strength Salt No No Pass Ignition Ignition Corrosion Rate: steel (10'j inches/yr) <1.5 0.76 Pass Cu-Ni (KT3inches/yr) <1.0 N.O.* Pass Ni-Cu (KT3inches/yr) <1.0 N.O.* Pass Bronze (mg) <100 N.O.* Pass Localized pitting (Corrosion- No Pits No Pits Pass resistant steel) Total Halides (ppm) <250 <50 Pass Dry Chemical Compatibility: Bum Back time (s) >360 625 Pass Environmental Impact: Toxicity (LC50) mg/L >1000 <2000* Pass COD (g O 2/L) <500 334 Pass BOD20/COD >0.65 0.88 Pass N.O.* = None Observed NOTE* - No fish (killifish (Fundulus Heteroclitus) mortality observed at concentrations < 2000 mg/L for the Type 6 AFFF concentrate. 1 US00000939 P arag rap h 3.3.2 Stability Property Type 6 Type 6 Pass/ Criteria Value Fail Spreading Coefficient on cyclohexane (dynes/cm): using aged concentrate mixed >3.0 4.64 Pass with fresh water using aged premix with fresh >3.0 5.39 Pass water using aged premix with salt water >3.0 5.70 Pass Foamability using aged concentrate(average of two measurements): Fresh Water Expansion Ratio >5.0 7.8 Pass Fresh Water Drain Time >2:30 5:51 Pass (minutes) Salt Water Expansion Ratio >5.0 7.6 Pass Salt Water Drain Time (minutes) >2:30 5:30 Pass Foamability using aged premix (average of two measurements): Fresh Water Expansion Ratio >5.0 8.3 Pass Fresh Water Drain Time >2:30 5:10 Pass (minutes) Salt Water Expansion Ratio >5.0 7.8 Pass Salt Water Drain Time (minutes) >2:30 5:37 Pass Film Formation: from aged concentrate, full no no Pass strength, fresh water ignition ignition from aged concentrate, full no no Pass strength, salt water ignition ignition from aged premix, full strength, no no Pass fresh water ignition ignition from aged premix, full strength, no no Pass salt water ignition ignition Fire Performance: Aged Concentrate, 'A strength, Fresh Extinguishment time (s) <45 43 Pass Bum back time (s) >300 538 Pass Aged Concentrate, 'A strength, Salt Extinguishment time (s) <45 38 Pass Bum back time (s) >300 420 Pass Aged Concentrate, full strength, Fresh Extinguishment time (s) <30 29 Pass Bum back time (s) >360 606 Pass Aged Concentrate, full strength, Salt Extinguishment time (s) <30 28 Pass Bum back time (s) >360 636 Pass Aged Premix, lA strength, Fresh Extinguishment time (s) <45 45 Pass Bum back time (s) >360 417 Pass Aged Premix, 'A strength Salt Extinguishment time (s) <45 45 Pass Bum back time (s) >360 485 Pass Aged Premix, full strength, Fresh Extinguishment time (s) <30 29 Pass Bum back time (s) >360 685 Pass Aged Premix, full strength, Salt 2 US00000940 Extinguishment time (s) Bum back time (s) <30 >360 26 Pass 560 Pass Property S tr a tific a tio n : using aged concentrate mixed with fresh water using aged premix with fresh water using aged premix with salt water P recip ita tio n (vol%): using aged concentrate mixed with fresh water using aged premix with fresh water using aged premix with salt water N.O.* = None Observed, Type 6 C riteria N.O.* N.O.* N.O.* <0.05 mL <0.05 mL <0.05 mL Type 6 V alue N.O.* N.O.* N.O.* N.O.* N.O.* N.O.* Pass/ F a il Pass Pass Pass Pass Pass Pass P arag rap h 3.3.3 Compatibility1 Mixture: Aer-O-Water 6EM-C6 / National1(Type 6) R equirem ent C riteria Stratification: using aged concentrate N.O.* P recip ita tio n (vo!%): using aged concentrate <0.05 F o a m a b ility u sin g a g ed c o n ce n tr a te (a v e ra g e o f two m ea su rem en ts): Fresh Water Expansion Ratio >5.0 Fresh Water Drain Time (minutes) >2:30 Salt Water Expansion Ratio >5.0 Salt Water Drain Time (minutes) >2:30 Film Form ation: from aged concentrate, 'A strength, fresh water no ignition from aged concentrate, Vi strength, salt water No ignition Fire Perform ance: Aged Concentrate, fresh water Extinguishment time (s) <30 Bum back time (s) >360 Aged Concentrate, salt water Extinguishment time (s) Bum back time (s) <30 >360 V a lu e Pass/ F a il N.O.* Pass N.O.* Pass 8.8 Pass 4:42 Pass 7.55 Pass 5:22 Pass no ignition no ignition Pass Pass 29 Pass 610 Pass 28 Pass 603 Pass 1National 6%-6EM Lot L12345, 2/13 3 US00000941 Mixture: Aer-O-Water 6EM-C6 / Ansai2 (50/50) (Type 6) R equirem ent C riteria S tr a tific a tio n : using aged concentrate N.O.* Precipitation (v o !% ): using aged concentrate <0.05 Foam ability using aged concentrate(average o f two m easurem ents): Fresh Water Expansion Ratio >5.0 Fresh Water Drain Time (minutes) >2:30 Salt Water Expansion Ratio >5.0 Salt Water Drain Time (minutes) >2:30 Film Form ation: fro m aged concentrate, 'A strength, fresh water no ignition from aged concentrate, 'A strength, salt water no ignition Fire Perform ance: Aged Concentrate, fresh water Extinguishment time (s) Bum back time (s) <30 >360 Aged Concentrate, salt water Extinguishment time (s) Bum back time (s) <30 >360 *N.O. = None Observed. Mixture: Aer-O-Water 6EM-C6 / Chemguard3(50/50) (Type 6) R equirem ent C riteria Stratification: using aged concentrate N.O.* Precipitation (vol% ): using aged concentrate <0.05 Foam ability using aged concentrate(average o f two m easurem ents): Fresh Water Expansion Ratio >5.0 Fresh Water Drain Time (minutes) >2:30 Salt Water Expansion Ratio >5.0 Salt Water Drain Time (minutes) >2:30 Film Form ation: from aged concentrate, A strength, fresh water from aged concentrate, 'A strength, salt water no ignition no ignition Fire Perform ance: Aged Concentrate, fresh water Extinguishment time (s) Bum back time (s) Aged Concentrate, salt water <30 >360 Extinguishment time (s) Bum back time (s) <30 >360 V alu e Pass/ Fail I N.O* Pass N.O* Pass 7.8 Pass 6:15 Pass 7.5 Pass 5:21 Pass no ignition no Ignition Pass Pass 28 Pass 495 Pass 26 Pass 515 Pass V a lu e Pass/ F a il N.O.* Pass N.O.* Pass 8.15 Pass 4:56 Pass 7.5 Pass 5:03 Pass no ignition no ignition Pass Pass 26 Pass 515 Pass 26 Pass 579 Pass 2Ansul 6% AFC5, Lot 1404, 4/14 3Chemguard 6%-C601 MS, Lot 0249113, 4/29/13 4 US00000942 Mixture: % er-O-Water 6EM-C6 / National / Ansul / Chemguard (Type 6) R equirem ent Criteria Value Stratification: using aged concentrate N.O.* Precipitation (vol%): using aged concentrate <0.05 Foamability using aged concentrate(average of two measurements): Fresh Water Expansion Ratio >5.0 Fresh Water Drain Time (minutes) >2:30 Salt Water Expansion Ratio >5.0 Salt Water Drain Time (minutes) >2:30 Film Formation: from aged concentrate, 'A strength, fresh water no ignition from aged concentrate, 'A strength, salt water no ignition Fire Performance: Aged Concentrate, fresh water Extinguishment time (s) <30 Bum back time (s) >360 Aged Concentrate, salt water Extinguishment time (s) <30 Bum back time (s) >360 N.O.* N.O.* 7.9 5:51 7.5 5:40 no ignition no ignition 28 589 29 524 P aragraph 3.4 Fire Perform ance 28 ft1Extinguishment Time (s) Fresh Water 'A strength Fresh Water full strength Salt Water 'A strength Salt Water full strength Salt Water Quintuple Strength Burn Back Time (s) Fresh Water Vi strength Fresh Water full strength Salt Water lA strength Salt Water full strength Salt Water Quintuple Strength SO ft2Fire Test (Salt Water) Extinguishment time (s) Bum back time (s) 40 second summation Type 6 requirement <45 <30 <45 <30 <55 >300 >360 >300 >360 >200 <50 >360 >320 Type 6 Value 39 25 36 29 31 410 605 487 560 429 38 504 380 Pass/ Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass/ Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass 5 US00000943 Additional Measurements: (1) - Container cap torque test results: Type 6 container 31 in/lbs. (2) - Total Fluorine: Aer-O-Water C6 6EM; 0.4485% (GLI Procedure E9-3) National Aero-O-Water Type 6 Container 6 US00000944