Document 7ODxQzKZdrOg1b764XN1K4EkE
90
CHAPTER 6
1965 Guide And Data Book
fluid Flow vr `
91
Deceleration*
suits. With flow in circular pipes, it appears that the transi tion from laminar to turbulent flow starts at a Reynolds number of about 2000 with the transition being complete at about '3000. A more detailed discussion of the' critical Reynolds number can be found in Reference 2.
The velocity profile in a closed conduit is a function of the Reynolds number as shown in Fig. 1.
Tn laminar flow,.the velocity profile is parabolic, and there fore the average velocity is one half the centerline velocity. In'turbulent flow, the velocity profile'is a function of Reyn olds number and the ratio of average to centerline velocity varies.*
fig. 4 .... Vortex Trail in the Wake of a Moving Cylinder1
A fluid flowing past' a boundary which curves in such a way as to produce a deceleration of the fluid results in an expan sion of the boundary layer with distance in the direction of flow. Since' the velocity at the boundary is already zero, further deceleration is physically impossible; the flow as a whole can continue beyond this tone only if a discontinuity at the boundary is produced. As shown in Fig. 2, such dis continuity involves separation of the flow from the boundary. Reverse flow then occurs in the region between the boundary and the fluid stream downstream of the point of separation. For the case of flow around a circular cylinder the reverse flow results in the formation of eddies as shown in Fig. 3, part A. As Reynolds number is increased the eddies break oS alternately on either side in a periodic fashion (Fig. 3, parts B and C) and this is the so-called von Kdrmdn vortex trail shown in Fig. 4.
With the flow of liquids, if at some point in the system the existing fluid pressure is reduced to the vapor pressure at the particular temperature, the liquid will vaporize forming a cavity or void. This phenomenon .is called cavitation. If the fluid pressure fluctuates above and below the vapor pressure, there will be an alternate formation and collapse of the vapor bubbles. This causes surface pitting on materials exposed to .the fluid and usually results in a noticeable noise. -
Frictional Pressure Drop for Incompressible Flow in Uniform Ducts
For incompressible flow in uniform ducts, the continuity Equation 2 shows.that the velocity is constant, since:
^ - 0.
dXL
(20)
Then, Equation 1 reduces to (for horizontal ducts):
~ -5 + n'f-
dxt D 2
<*
Since V and D and, hence, /d are constant, Equation 21 can
be integrated to give:
. _ _* foL i>V*
(22)
fig. 3 .... Wake Behind a Stationary Cylinder, Showing Successive Stages of Eddy Formation After the Commence
ment of Row*
where Ap is thestatic pressure drop in duct-length L. As mentioned previously, the friction factor /o is in general
a function of Reynolds number Ns*,- and relative roughness
e/D. For Ns, < 2000, the flow is laminar and
f-~ Nr.
<">
Note that for laminar flow, the friction factor /o and hence
Ap is independent of surface roughness. For Reynolds numbers greater- than about 3000, the flow
can be considered turbulent and the -friction factor can be evaluated from Fig. o.Upon referring to Fig. 5,.it is seen that
a curve of fo versus Ns* exists for each relative, roughness. The lowest curve represents a limiting envelope for vanishing roughness. It is the so-called smooth pipe resistance law. For Reynolds numbers up to 10s, the smooth pipe friction factor is given by the Blasius relation
/a - 0.316(Aa.)-1'4
(24)
Table 4 lists the absolute roughness e for various commercial
surfaces (new). .
,V
As mentioned previously, the parameter, D of Equation 22
is the duct equivalent' diameter defined by
D~p-m
(25)
Although the above value of D can be used in computing Reynolds number, a slightly better procedure for rectangular ducts is to replace D by the shortest dimension plus one fourth of D. That is
VQ> + 0.25P) Nr.
(26)
kre b is the shortest dimension of the rectangular cross section.
Two-Phase Row
In addition to examining single phase flow phenomena, it is aian of interest to consider the situation where both liquid and vapor phases exist simultaneously. This situation is encount ered in evaporators, condensers,- capillary tubes and other components used:in refrigeration and air-conditioning equip ment. Although both heat transfer, and hydrauiic data are, in. general, of interest for .these two phase flows, the discussion here will be limited to hydraulics and particularly to pressure drop computations for tubes in which the flow pattern is such that the tube walls are wetted.primarily with liquid. It will
Table 4 ..... Absolute Roughness Values
type of Sorfoco
Glass, drawn metallic tubing Wrought iron, steel - <
Galvanized iron Cast steel.
Riveted steel
AbtaiuH Soughoma, o, ft
Smooth
0.00015 0.0004
0.0005
0.00085 0.001 to 0.01 0.003 to 0.03
: ,
,